<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org)
<br />BCSI Building Component Safety Information
<br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
<br />and available from the Structural Building Component Association (www.sbcscomponents.com)
<br />412
<br />3612
<br />=4x5 =2x4
<br />=3x5
<br />=3x5
<br />=3x5
<br />=4x5
<br />=6x8
<br />=6x10
<br />=3x5 =5x8
<br />=3x4
<br />=6x6
<br />=5x5
<br />=3x5
<br />=3x5
<br />=2x4 =4x6
<br />12
<br />3919 18 17 16
<br />15
<br />14 13
<br />1113826
<br />27 3736282
<br />1029
<br />3 353094
<br />34313385
<br />32
<br />6 7
<br />0-1-2
<br />32-4-8
<br />0-1-14
<br />13-5-4
<br />1-0-0
<br />46-1-0
<br />0-11-6
<br />27-2-14
<br />4-0-10
<br />13-3-6
<br />4-2-8
<br />9-2-12
<br />5-0-4
<br />5-0-4
<br />5-10-13
<br />38-3-5
<br />6-6-15
<br />26-3-8
<br />6-3-5
<br />19-8-9
<br />6-9-11
<br />45-1-0
<br />5-0-9
<br />32-3-7
<br />4-2-8
<br />9-2-12
<br />4-2-8
<br />13-5-4
<br />5-0-4
<br />5-0-4
<br />5-11-15
<br />38-3-5
<br />6-1-11
<br />32-3-7
<br />6-3-5
<br />19-8-9
<br />6-5-3
<br />26-1-12
<br />6-9-11
<br />45-1-0
<br />9-
<br />8
<br />-
<br />1
<br />0
<br />0-
<br />3
<br />-
<br />1
<br />5
<br />2-
<br />9
<br />-
<br />1
<br />3
<br />6-
<br />7
<br />-
<br />2
<br />6-
<br />7
<br />-
<br />2
<br />2-
<br />9
<br />-
<br />1
<br />3
<br />9-
<br />4
<br />-
<br />1
<br />4
<br />Scale = 1:80.3
<br />Plate Offsets (X, Y):[4:0-2-12,0-3-0], [8:0-6-4,0-3-8], [9:0-1-12,0-3-0], [15:0-3-0,Edge]
<br />Loading (psf)Spacing 2-3-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
<br />TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) -0.19 15-16 >999 240 MT20 220/195
<br />TCDL 16.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.61 15-16 >623 180
<br />BCLL 0.0*Rep Stress Incr NO WB 0.99 Horz(CT) 0.10 11 n/a n/a
<br />BCDL 10.0 Code IBC2021/TPI2014 Matrix-MS Weight: 229 lb FT = 20%
<br />LUMBER
<br />TOP CHORD 2X4 DF No.1&Btr G
<br />BOT CHORD 2X4 DF No.2 G *Except* 15-11:2X4 DF
<br />No.1&Btr G
<br />WEBS 2X4 DF Std G *Except* 4-16:2X4 DF No.2 G
<br />BRACING
<br />TOP CHORD Structural wood sheathing directly applied or
<br />2-11-1 oc purlins, except end verticals.
<br />Except:
<br />6-0-0 oc bracing: 6-8
<br />BOT CHORD Rigid ceiling directly applied or 4-3-13 oc
<br />bracing.
<br />WEBS 1 Row at midpt 9-15, 8-16
<br />REACTIONS (size) 1=0-3-8, 11=0-3-8, 17=0-3-8
<br />Max Horiz 1=321 (LC 12)
<br />Max Uplift 1=-26 (LC 8), 11=-262 (LC 9),
<br />17=-357 (LC 8)
<br />Max Grav 1=340 (LC 42), 11=1594 (LC 2),
<br />17=3315 (LC 2)
<br />FORCES (lb) - Maximum Compression/Maximum
<br />Tension
<br />TOP CHORD 1-2=-243/460, 2-3=-274/1178,
<br />3-5=-678/1966, 5-6=-154/84, 6-7=-29/0,
<br />8-10=-2991/550, 10-11=-4205/662,
<br />11-12=0/27, 8-15=-33/1048, 6-8=-391/248
<br />BOT CHORD 1-19=-405/219, 18-19=-405/219,
<br />17-18=-1089/192, 14-17=-1942/2725,
<br />13-14=-557/3938, 11-13=-557/3938
<br />WEBS 9-15=-1383/192, 9-14=0/733,
<br />10-14=-1311/239, 10-13=0/290,
<br />4-17=-2826/484, 5-16=-465/189,
<br />8-16=-1514/304, 5-8=-605/310,
<br />4-16=-427/2961, 2-19=0/246, 3-18=-5/460,
<br />2-18=-953/152, 3-17=-974/183
<br />NOTES
<br />1) Unbalanced roof live loads have been considered for
<br />this design.
<br />2) Wind: ASCE 7-16; Vult=110mph (3-second gust)
<br />Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat.
<br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone
<br />and C-C Exterior(2E) 0-0-0 to 4-6-2, Interior (1) 4-6-2 to
<br />46-1-9 zone; cantilever left and right exposed ; end
<br />vertical left and right exposed;C-C for members and
<br />forces & MWFRS for reactions shown; Lumber
<br />DOL=1.60 plate grip DOL=1.60
<br />3) This truss has been designed for a 10.0 psf bottom
<br />chord live load nonconcurrent with any other live loads.
<br />4) * This truss has been designed for a live load of 20.0psf
<br />on the bottom chord in all areas where a rectangle
<br />3-06-00 tall by 2-00-00 wide will fit between the bottom
<br />chord and any other members, with BCDL = 10.0psf.
<br />5) A plate rating reduction of 20% has been applied for the
<br />green lumber members.
<br />6) WARNING: Required bearing size at joint(s) 17 greater
<br />than input bearing size.
<br />7) Bearings are assumed to be: Joint 1 DF No.2 , Joint 17
<br />DF No.2 , Joint 11 DF No.1&Btr .
<br />8) Provide mechanical connection (by others) of truss to
<br />bearing plate capable of withstanding 262 lb uplift at joint
<br />11, 357 lb uplift at joint 17 and 26 lb uplift at joint 1.
<br />9) This truss has been designed for a moving concentrated
<br />load of 250.0lb live located at all mid panels and at all
<br />panel points along the Top Chord, nonconcurrent with
<br />any other live loads.
<br />LOAD CASE(S) Standard
<br />Job Truss Truss Type Qty Ply 601 -603 W 10th St
<br />R91123159
<br />B03 Roof Special 2 1250894-Duplex Job Reference (optional)
<br />Stone Truss, Inc., Oceanside, CA - 92054,Run: 8.73 S Aug 13 2025 Print: 8.730 S Aug 13 2025 MiTek Industries, Inc. Wed Nov 05 18:57:45 Page: 1
<br />ID:QQszJfIoUWLk4AyrCyKaxGyMb97-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f
<br />November 6,2025
|