Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />412 <br />3612 <br />=3x5 =1.5x4 <br />=3x4 <br />=4x5 <br />=6x6 <br />=7x8 <br />=5x5 <br />=1.5x4 <br />=8x10 <br />=5x5 <br />=4x6 <br />=1.5x4 <br />=5x8 <br />=4x6 <br />=2x4 <br />=5x8 <br />=5x8 <br />=2x4 <br />=5x6 <br />=3x8 <br />=3x4 <br />=1.5x4 =4x6 <br />13 <br />20 19 18 17 15 14 <br />12 <br />43 44 <br />1 16 42 <br />41403031 <br />112 <br />3932 <br />103 <br />23 <br />22 <br />21 <br />33 38437934 <br />5 35 6 36 7 8 <br />5-0-0 <br />0-0-10 <br />17-0-4 <br />0-0-10 <br />31-11-15 <br />1-0-0 <br />45-9-8 <br />0-3-8 <br />26-0-0 <br />2-7-12 <br />23-2-8 <br />0-11-6 <br />26-11-6 <br />3-6-8 <br />20-6-12 <br />2-6-0 <br />25-8-8 <br />3-9-14 <br />16-11-10 <br />5-10-12 <br />13-1-12 <br />5-11-15 <br />37-11-13 <br />4-11-14 <br />31-11-4 <br />6-9-11 <br />44-9-8 <br />7-3-0 <br />7-3-0 <br />0-1-12 <br />13-1-12 <br />3-7-3 <br />20-6-12 <br />3-9-13 <br />16-11-9 <br />5-3-8 <br />25-10-4 <br />5-9-0 <br />13-0-0 <br />5-11-15 <br />37-11-13 <br />6-1-11 <br />31-11-15 <br />6-9-11 <br />44-9-8 <br />7-3-0 <br />7-3-0 <br />9- <br />8 <br />- <br />1 <br />0 <br />0- <br />5 <br />- <br />2 <br />0- <br />3 <br />- <br />1 <br />5 <br />4- <br />0 <br />- <br />1 <br />2 <br />2- <br />9 <br />- <br />1 <br />3 <br />0- <br />3 <br />- <br />8 <br />6- <br />7 <br />- <br />2 <br />6- <br />7 <br />- <br />2 <br />2- <br />9 <br />- <br />1 <br />3 <br />9- <br />4 <br />- <br />1 <br />4 <br />Scale = 1:83.3 <br />Plate Offsets (X, Y):[4:0-2-8,0-3-0], [10:0-2-8,0-3-0], [21:0-2-12,0-3-4] <br />Loading (psf)Spacing 2-3-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP <br />TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) -0.17 15-16 >999 240 MT20 220/195 <br />TCDL 16.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -0.83 15-16 >458 180 <br />BCLL 0.0*Rep Stress Incr NO WB 0.85 Horz(CT) 0.12 12 n/a n/a <br />BCDL 10.0 Code IBC2021/TPI2014 Matrix-MP Attic -0.05 16-17 >999 360 Weight: 255 lb FT = 20% <br />LUMBER <br />TOP CHORD 2X4 DF No.1&Btr G *Except* 4-8:2X4 DF <br />No.2 G <br />BOT CHORD 2X4 DF No.2 G *Except* 16-12:2X4 DF <br />No.1&Btr G <br />WEBS 2X4 DF Std G *Except* 7-16,18-3:2X4 DF <br />No.2 G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />2-11-10 oc purlins, except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 4-7-14 oc <br />bracing. <br />WEBS 1 Row at midpt 3-19, 18-21, 10-22 <br />JOINTS 1 Brace at Jt(s): 21, <br />23 <br />REACTIONS (size) 1= Mechanical, 12=0-3-8, <br />19=0-3-8, (req. 0-3-11) <br />Max Horiz 1=219 (LC 12) <br />Max Uplift 1=-113 (LC 29), 12=-180 (LC 9), <br />19=-106 (LC 8) <br />Max Grav 1=263 (LC 32), 12=1617 (LC 1), <br />19=3464 (LC 1) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-2=-97/883, 2-3=-206/1964, 3-5=-486/2297, <br />5-6=-439/2280, 6-7=-223/0, 7-8=-29/0, <br />16-22=0/450, 9-22=-278/288, 7-9=-299/222, <br />9-11=-3020/334, 11-12=-4074/452, <br />12-13=0/27 <br />BOT CHORD 1-20=-789/90, 19-20=-789/90, <br />17-19=-1821/2298, 15-17=-96/2313, <br />14-15=-358/3817, 12-14=-358/3817 <br />WEBS 17-21=0/436, 5-21=-398/127, <br />21-23=-2808/427, 22-23=-2804/427, <br />2-20=0/347, 2-19=-1207/217, <br />3-19=-3079/250, 4-18=-187/1072, <br />18-21=-3942/363, 3-18=-97/2724, <br />4-21=-2172/455, 10-15=-17/240, <br />15-22=-207/734, 11-15=-1144/249, <br />10-22=-2294/347, 11-14=0/287, <br />6-21=-2632/371, 6-23=-27/355, <br />6-22=-154/938 <br />NOTES <br />1) Unbalanced roof live loads have been considered for <br />this design. <br />2) Wind: ASCE 7-16; Vult=110mph (3-second gust) <br />Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Exterior(2E) 0-0-0 to 4-5-12, Interior (1) 4-5-12 <br />to 45-10-1 zone; cantilever left and right exposed ; end <br />vertical left and right exposed;C-C for members and <br />forces & MWFRS for reactions shown; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />3) 100.0lb AC unit load placed on the bottom chord, 23-2-8 <br />from left end, supported at two points, 3-0-0 apart. <br />4) This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />5) * This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />6) Ceiling dead load (5.0 psf) on member(s). 21-23, 22-23 <br />7) Bottom chord live load (20.0 psf) and additional bottom <br />chord dead load (20.0 psf) applied only to room. 16-17 <br />8) A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />9) WARNING: Required bearing size at joint(s) 19 greater <br />than input bearing size. <br />10) Bearings are assumed to be: , Joint 19 DF No.2 , Joint <br />12 DF No.1&Btr . <br />11) Refer to girder(s) for truss to truss connections. <br />12) Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 113 lb uplift at joint <br />1, 106 lb uplift at joint 19 and 180 lb uplift at joint 12. <br />13) This truss has been designed for a moving concentrated <br />load of 250.0lb live located at all mid panels and at all <br />panel points along the Top Chord, nonconcurrent with <br />any other live loads. <br />14) Attic room checked for L/360 deflection. <br />LOAD CASE(S) Standard <br />Job Truss Truss Type Qty Ply 601 -603 W 10th St <br />R91123160 <br />B04 Attic 2 1250894-Duplex Job Reference (optional) <br />Stone Truss, Inc., Oceanside, CA - 92054,Run: 8.73 S Aug 13 2025 Print: 8.730 S Aug 13 2025 MiTek Industries, Inc. Wed Nov 05 18:57:45 Page: 1 <br />ID:KAuAPzcbVCPeVW2YuZFNBYyMb68-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />November 6,2025