400 Sunrise Ave., Suite 270
<br />Roseville, CA 95661
<br />916.755.3571 / MiTek-US.com
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org)
<br />BCSI Building Component Safety Information
<br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
<br />and available from the Structural Building Component Association (www.sbcscomponents.com)
<br />412
<br />3612
<br />=3x5 =1.5x4
<br />=3x4
<br />=4x5
<br />=6x6
<br />=7x8
<br />=5x5
<br />=1.5x4
<br />=8x10
<br />=5x5
<br />=4x6
<br />=1.5x4
<br />=5x8
<br />=4x6
<br />=2x4
<br />=5x8
<br />=5x8
<br />=2x4
<br />=5x6
<br />=3x8
<br />=3x4
<br />=1.5x4 =4x6
<br />13
<br />20 19 18 17 15 14
<br />12
<br />43 44
<br />1 16 42
<br />41403031
<br />112
<br />3932
<br />103
<br />23
<br />22
<br />21
<br />33 38437934
<br />5 35 6 36 7 8
<br />5-0-0
<br />0-0-10
<br />17-0-4
<br />0-0-10
<br />31-11-15
<br />1-0-0
<br />45-9-8
<br />0-3-8
<br />26-0-0
<br />2-7-12
<br />23-2-8
<br />0-11-6
<br />26-11-6
<br />3-6-8
<br />20-6-12
<br />2-6-0
<br />25-8-8
<br />3-9-14
<br />16-11-10
<br />5-10-12
<br />13-1-12
<br />5-11-15
<br />37-11-13
<br />4-11-14
<br />31-11-4
<br />6-9-11
<br />44-9-8
<br />7-3-0
<br />7-3-0
<br />0-1-12
<br />13-1-12
<br />3-7-3
<br />20-6-12
<br />3-9-13
<br />16-11-9
<br />5-3-8
<br />25-10-4
<br />5-9-0
<br />13-0-0
<br />5-11-15
<br />37-11-13
<br />6-1-11
<br />31-11-15
<br />6-9-11
<br />44-9-8
<br />7-3-0
<br />7-3-0
<br />9-
<br />8
<br />-
<br />1
<br />0
<br />0-
<br />5
<br />-
<br />2
<br />0-
<br />3
<br />-
<br />1
<br />5
<br />4-
<br />0
<br />-
<br />1
<br />2
<br />2-
<br />9
<br />-
<br />1
<br />3
<br />0-
<br />3
<br />-
<br />8
<br />6-
<br />7
<br />-
<br />2
<br />6-
<br />7
<br />-
<br />2
<br />2-
<br />9
<br />-
<br />1
<br />3
<br />9-
<br />4
<br />-
<br />1
<br />4
<br />Scale = 1:83.3
<br />Plate Offsets (X, Y):[4:0-2-8,0-3-0], [10:0-2-8,0-3-0], [21:0-2-12,0-3-4]
<br />Loading (psf)Spacing 2-3-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
<br />TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) -0.17 15-16 >999 240 MT20 220/195
<br />TCDL 16.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -0.83 15-16 >458 180
<br />BCLL 0.0*Rep Stress Incr NO WB 0.85 Horz(CT) 0.12 12 n/a n/a
<br />BCDL 10.0 Code IBC2021/TPI2014 Matrix-MP Attic -0.05 16-17 >999 360 Weight: 255 lb FT = 20%
<br />LUMBER
<br />TOP CHORD 2X4 DF No.1&Btr G *Except* 4-8:2X4 DF
<br />No.2 G
<br />BOT CHORD 2X4 DF No.2 G *Except* 16-12:2X4 DF
<br />No.1&Btr G
<br />WEBS 2X4 DF Std G *Except* 7-16,18-3:2X4 DF
<br />No.2 G
<br />BRACING
<br />TOP CHORD Structural wood sheathing directly applied or
<br />2-11-10 oc purlins, except end verticals.
<br />BOT CHORD Rigid ceiling directly applied or 4-7-14 oc
<br />bracing.
<br />WEBS 1 Row at midpt 3-19, 18-21, 10-22
<br />JOINTS 1 Brace at Jt(s): 21,
<br />23
<br />REACTIONS (size) 1= Mechanical, 12=0-3-8,
<br />19=0-3-8, (req. 0-3-11)
<br />Max Horiz 1=219 (LC 12)
<br />Max Uplift 1=-113 (LC 29), 12=-180 (LC 9),
<br />19=-106 (LC 8)
<br />Max Grav 1=263 (LC 32), 12=1617 (LC 1),
<br />19=3464 (LC 1)
<br />FORCES (lb) - Maximum Compression/Maximum
<br />Tension
<br />TOP CHORD 1-2=-97/883, 2-3=-206/1964, 3-5=-486/2297,
<br />5-6=-439/2280, 6-7=-223/0, 7-8=-29/0,
<br />16-22=0/450, 9-22=-278/288, 7-9=-299/222,
<br />9-11=-3020/334, 11-12=-4074/452,
<br />12-13=0/27
<br />BOT CHORD 1-20=-789/90, 19-20=-789/90,
<br />17-19=-1821/2298, 15-17=-96/2313,
<br />14-15=-358/3817, 12-14=-358/3817
<br />WEBS 17-21=0/436, 5-21=-398/127,
<br />21-23=-2808/427, 22-23=-2804/427,
<br />2-20=0/347, 2-19=-1207/217,
<br />3-19=-3079/250, 4-18=-187/1072,
<br />18-21=-3942/363, 3-18=-97/2724,
<br />4-21=-2172/455, 10-15=-17/240,
<br />15-22=-207/734, 11-15=-1144/249,
<br />10-22=-2294/347, 11-14=0/287,
<br />6-21=-2632/371, 6-23=-27/355,
<br />6-22=-154/938
<br />NOTES
<br />1) Unbalanced roof live loads have been considered for
<br />this design.
<br />2) Wind: ASCE 7-16; Vult=110mph (3-second gust)
<br />Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat.
<br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone
<br />and C-C Exterior(2E) 0-0-0 to 4-5-12, Interior (1) 4-5-12
<br />to 45-10-1 zone; cantilever left and right exposed ; end
<br />vertical left and right exposed;C-C for members and
<br />forces & MWFRS for reactions shown; Lumber
<br />DOL=1.60 plate grip DOL=1.60
<br />3) 100.0lb AC unit load placed on the bottom chord, 23-2-8
<br />from left end, supported at two points, 3-0-0 apart.
<br />4) This truss has been designed for a 10.0 psf bottom
<br />chord live load nonconcurrent with any other live loads.
<br />5) * This truss has been designed for a live load of 20.0psf
<br />on the bottom chord in all areas where a rectangle
<br />3-06-00 tall by 2-00-00 wide will fit between the bottom
<br />chord and any other members.
<br />6) Ceiling dead load (5.0 psf) on member(s). 21-23, 22-23
<br />7) Bottom chord live load (20.0 psf) and additional bottom
<br />chord dead load (20.0 psf) applied only to room. 16-17
<br />8) A plate rating reduction of 20% has been applied for the
<br />green lumber members.
<br />9) WARNING: Required bearing size at joint(s) 19 greater
<br />than input bearing size.
<br />10) Bearings are assumed to be: , Joint 19 DF No.2 , Joint
<br />12 DF No.1&Btr .
<br />11) Refer to girder(s) for truss to truss connections.
<br />12) Provide mechanical connection (by others) of truss to
<br />bearing plate capable of withstanding 113 lb uplift at joint
<br />1, 106 lb uplift at joint 19 and 180 lb uplift at joint 12.
<br />13) This truss has been designed for a moving concentrated
<br />load of 250.0lb live located at all mid panels and at all
<br />panel points along the Top Chord, nonconcurrent with
<br />any other live loads.
<br />14) Attic room checked for L/360 deflection.
<br />LOAD CASE(S) Standard
<br />Job Truss Truss Type Qty Ply 601 -603 W 10th St
<br />R91123160
<br />B04 Attic 2 1250894-Duplex Job Reference (optional)
<br />Stone Truss, Inc., Oceanside, CA - 92054,Run: 8.73 S Aug 13 2025 Print: 8.730 S Aug 13 2025 MiTek Industries, Inc. Wed Nov 05 18:57:45 Page: 1
<br />ID:KAuAPzcbVCPeVW2YuZFNBYyMb68-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f
<br />November 6,2025
|