Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />412 <br />3612 <br />=3x5 =1.5x4 <br />=3x4 <br />=4x5 <br />=6x6 <br />=6x8 <br />=5x5 <br />=1.5x4 <br />=8x8 <br />=4x6 <br />=4x6 <br />=5x8 <br />=1.5x4 <br />=4x6 <br />=5x8 <br />=3x4 <br />=5x8 <br />=4x4 <br />=5x5 <br />=3x8 <br />=3x4 <br />=1.5x4 =4x5 <br />13 <br />20 19 18 17 15 14 <br />12 <br />43 44 <br />1 16 42 <br />41403031 <br />112 <br />3932 <br />103 <br />23 <br />22 <br />21 <br />33 38437934 <br />5 35 6 36 7 8 <br />5-0-0 <br />0-0-10 <br />17-0-4 <br />0-0-10 <br />31-11-15 <br />1-0-0 <br />45-9-8 <br />0-3-8 <br />26-0-0 <br />2-7-12 <br />23-2-8 <br />0-11-6 <br />26-11-6 <br />3-6-8 <br />20-6-12 <br />2-6-0 <br />25-8-8 <br />3-9-14 <br />16-11-10 <br />5-10-12 <br />13-1-12 <br />5-11-15 <br />37-11-13 <br />4-11-14 <br />31-11-4 <br />6-9-11 <br />44-9-8 <br />7-3-0 <br />7-3-0 <br />0-1-12 <br />13-1-12 <br />3-7-3 <br />20-6-12 <br />3-9-13 <br />16-11-9 <br />5-3-8 <br />25-10-4 <br />5-9-0 <br />13-0-0 <br />5-11-15 <br />37-11-13 <br />6-1-11 <br />31-11-15 <br />6-9-11 <br />44-9-8 <br />7-3-0 <br />7-3-0 <br />9- <br />8 <br />- <br />1 <br />0 <br />0- <br />5 <br />- <br />2 <br />0- <br />3 <br />- <br />1 <br />5 <br />4- <br />0 <br />- <br />1 <br />2 <br />2- <br />9 <br />- <br />1 <br />3 <br />0- <br />3 <br />- <br />8 <br />6- <br />7 <br />- <br />2 <br />6- <br />7 <br />- <br />2 <br />2- <br />9 <br />- <br />1 <br />3 <br />9- <br />4 <br />- <br />1 <br />4 <br />Scale = 1:83.3 <br />Plate Offsets (X, Y):[4:0-2-8,0-3-0], [10:0-2-4,0-3-0], [18:0-3-12,0-3-0], [21:0-2-0,0-3-8] <br />Loading (psf)Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP <br />TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.89 Vert(LL) -0.16 15-16 >999 240 MT20 220/195 <br />TCDL 16.0 Lumber DOL 1.25 BC 0.77 Vert(CT) -0.76 15-16 >499 180 <br />BCLL 0.0*Rep Stress Incr YES WB 0.96 Horz(CT) 0.12 12 n/a n/a <br />BCDL 10.0 Code IBC2021/TPI2014 Matrix-MS Attic -0.05 16-17 >999 360 Weight: 255 lb FT = 20% <br />LUMBER <br />TOP CHORD 2X4 DF No.2 G *Except* 9-10,10-13:2X4 DF <br />No.1&Btr G <br />BOT CHORD 2X4 DF No.2 G <br />WEBS 2X4 DF Std G *Except* 7-16,18-3:2X4 DF <br />No.2 G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />3-2-11 oc purlins, except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 4-11-6 oc <br />bracing. <br />WEBS 1 Row at midpt 18-21, 10-22 <br />JOINTS 1 Brace at Jt(s): 21, <br />23 <br />REACTIONS (size) 1= Mechanical, 12=0-3-8, 19=0-3-8 <br />Max Horiz 1=195 (LC 12) <br />Max Uplift 1=-101 (LC 29), 12=-157 (LC 9), <br />19=-83 (LC 8) <br />Max Grav 1=261 (LC 32), 12=1442 (LC 1), <br />19=3086 (LC 1) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-2=-79/787, 2-3=-176/1746, 3-5=-435/2012, <br />5-6=-393/1986, 6-7=-238/0, 7-8=-26/0, <br />9-11=-2699/286, 11-12=-3634/391, <br />12-13=0/24, 16-22=0/410, 9-22=-285/264, <br />7-9=-331/199 <br />BOT CHORD 1-20=-705/93, 19-20=-705/76, <br />17-19=-1619/2041, 15-17=-81/2055, <br />14-15=-308/3405, 12-14=-308/3405 <br />WEBS 2-20=0/312, 17-21=0/388, 5-21=-394/112, <br />21-23=-2485/383, 22-23=-2481/382, <br />3-19=-2745/212, 4-18=-168/940, <br />18-21=-3495/315, 3-18=-76/2429, <br />4-21=-1906/407, 10-15=-46/201, <br />15-22=-177/665, 11-14=0/254, <br />2-19=-1073/193, 11-15=-1016/221, <br />10-22=-1911/286, 6-23=-24/314, <br />6-21=-2311/322, 6-22=-129/913 <br />NOTES <br />1) Unbalanced roof live loads have been considered for <br />this design. <br />2) Wind: ASCE 7-16; Vult=110mph (3-second gust) <br />Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Exterior(2E) 0-0-0 to 4-5-12, Interior (1) 4-5-12 <br />to 45-10-1 zone; cantilever left and right exposed ; end <br />vertical left and right exposed;C-C for members and <br />forces & MWFRS for reactions shown; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />3) 100.0lb AC unit load placed on the bottom chord, 23-6-0 <br />from left end, supported at two points, 3-0-0 apart. <br />4) This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />5) * This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />6) Ceiling dead load (5.0 psf) on member(s). 21-23, 22-23 <br />7) Bottom chord live load (20.0 psf) and additional bottom <br />chord dead load (20.0 psf) applied only to room. 16-17 <br />8) A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />9) Bearings are assumed to be: , Joint 19 DF No.2 , Joint <br />12 DF No.2 . <br />10) Refer to girder(s) for truss to truss connections. <br />11) Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 83 lb uplift at joint <br />19, 157 lb uplift at joint 12 and 101 lb uplift at joint 1. <br />12) This truss has been designed for a moving concentrated <br />load of 250.0lb live located at all mid panels and at all <br />panel points along the Top Chord, nonconcurrent with <br />any other live loads. <br />13) Attic room checked for L/360 deflection. <br />LOAD CASE(S) Standard <br />Job Truss Truss Type Qty Ply 601 -603 W 10th St <br />R91123161 <br />B05 Attic 6 1250894-Duplex Job Reference (optional) <br />Stone Truss, Inc., Oceanside, CA - 92054,Run: 8.73 S Aug 13 2025 Print: 8.730 S Aug 13 2025 MiTek Industries, Inc. Wed Nov 05 18:57:45 Page: 1 <br />ID:EdXzLlsu?u2egL0oL764Y2yMosL-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />November 6,2025