SOLAREDGE BACKUP
<br />INTERFACE BI-NUSGN-01
<br />200A RATED, 240V
<br />NEMA 3R, UL LISTED
<br />CONTROLLER
<br />G
<br />N
<br />(E) BACKUP LOAD PANEL GE,
<br />125A RATED, 120/240V
<br />30A/2P
<br />N
<br />G
<br />AUTO TRANSFORMER AUTO TRANSFER RELAY
<br />L1
<br />L2
<br />N
<br />G
<br />3
<br />(N) SOLAR BREAKER
<br />L1 L2 N G
<br />(N) BACKUP BREAKER
<br />240V, 100A/2P
<br />1 2
<br />G
<br />L1
<br />L2
<br />(14) JA SOLAR:JAM54S31 405/MR
<br />405W MODULES
<br />-+
<br />-++
<br />-+
<br />+++---
<br />2
<br />-+
<br />-
<br />1 3
<br />=
<br />=
<br />=
<br />=
<br />=
<br />=
<br />=
<br />=
<br />=
<br />=
<br />STRING #1
<br />13 14
<br />SOLAREDGE POWER OPTIMIZERS S440 RATED
<br />DC INPUT POWER - 440WATTS
<br />MAXIMUM INPUT VOLTAGE - 60 VDC
<br />MPPT RANGE - 8 TO 60 VDC
<br />MAXIMUM SHORT CIRCUIT CURRENT - 14.5 ADC
<br />MAXIMUM OUTPUT CURRENT - 15 ADC
<br />STRING LIMITATIONS - 8 TO 25 OPTIMIZERS,
<br />5700 WATTS STC PER STRING MAXIMUM
<br />JUNCTION BOX,
<br />600V, NEMA 3R,
<br />UL LISTED LOAD GN
<br />PV DISCONNECT(2 OF 2)
<br />240V, 1ɸ, 3W
<br />30A RATED
<br />NEMA 3R (EATON DG221URB)
<br />VISIBLE, LOCKABLE,
<br />LABELED AC DISCONNECT
<br />LOCATED WITHIN 10' OF
<br />UTILITY METER
<br />LINE
<br />4
<br />SOLAREDGE: SE5700H-US
<br />HOME HUB INVERTER
<br />OUTPUT: 240 VAC, 24A
<br />99% CEC WEIGHTED EFFICIENCY
<br />NEMA 3R, UL LISTED, INTERNAL GFDI
<br />WITH INTEGRATED DC DISCONNECT
<br />3A
<br />L1
<br />L2
<br />G
<br />10 kWh
<br />SOLAREDGE
<br />ENERGY BANK
<br />NOTE: ANY MULTIWIRE BRANCH
<br />CIRCUITS RELOCATED ARE TO
<br />BE IDENTIFIED, GROUPED, AND
<br />EQUIPPED WITH A 2-
<br />POLE OCPD BREAKER PER CEC
<br />210.4(B,D).
<br />"NOTE: ALL LOADS ARE
<br />EXISTING AND MOVED
<br />FROM MAIN PANEL"
<br />NOTE: IF THE RELOCATED
<br />LOADS EXTEND
<br />MORE THAN 6 FEET, AFCI
<br />PROTECTION
<br />APPLIES PER 2019 CEC 210.12
<br />LOAD SIDE
<br />INTERCONCECTION
<br />AT MAIN PANEL PER
<br />ART. 705.12
<br />L1
<br />L2
<br />G
<br />N
<br />(N) MAIN BREAKER TO
<br />HOUSE 240 V, 200A/2P
<br />(1 OF 2)
<br />N
<br />G
<br />NL2L1
<br />TO UTILITY GRID
<br />M BI-DIRECTIONAL
<br />UTILITY METER
<br />120/240V, 1ɸ, 3-W
<br />(N) MAIN SERVICE
<br />PANEL,
<br />200A RATED, 240V
<br />L1
<br />L2
<br />G
<br />10 kWh
<br />SOLAREDGE
<br />ENERGY BANK
<br />4
<br />INTERCONNECTION REF
<br />705.12 BACKFEED
<br />100A/2P
<br />(E) BONDING JUMPER
<br />PER NEC 250.92(A)(2)
<br />NEW GROUNDING ELECRODES &
<br />NEW AUXILLARY GROUNDING
<br />ELECTRODE (6 FEET APART). REQ.
<br />5/8" DIA. GROUNDING ROD WITH 8'
<br />MIN. EMBEDMENT
<br />MIN 6" BETWEEN
<br />ELECTRODES
<br />BOND COLD WATER
<br />& GAS LINE
<br />CEC 250.104 (A) & (B)
<br />NOTE:
<br />1. UPGRADE METER MAIN COMBO TO 200A RATED BUS
<br />WITH 200A MAIN BREAKER.
<br />2. NEW MSP WILL INSTALLATED IN THE SAME LOCATION
<br />AS THAT OF EXISTING MSP.
<br />L1
<br />L2
<br />N
<br />G
<br />3
<br />REV
<br />SHEET NAME
<br />SHEET SIZE
<br />SHEET NUMBER
<br />EL
<br />V
<br />I
<br />S
<br />
<br />M
<br />A
<br />R
<br />T
<br />I
<br />N
<br />E
<br />Z
<br />RE
<br />S
<br />I
<br />D
<br />E
<br />N
<br />C
<br />E
<br />14
<br />2
<br />9
<br /> S
<br />G
<br />A
<br />R
<br />N
<br />S
<br />E
<br />Y
<br />
<br />S
<br />T
<br />,
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />CA
<br />
<br />9
<br />2
<br />7
<br />0
<br />7
<br />ANSI B
<br />11" X 17"
<br />DATEDESCRIPTION
<br />REVISIONS
<br />PROJECT NAME & ADDRESS
<br />DATE:05/05/2025
<br />DRAWN BY
<br />ESR
<br />MONA LEE SOLAR
<br />D08/05/2025AHJ COMMENT
<br />ELECTRICAL LINE
<br />DIAGRAM
<br />1 ELECTRICAL LINE DIAGRAM
<br />PV-6 SCALE: NTS PV-6
<br />INSTALLER / ELECTRICIAN NOTE:
<br />EC IS TO MEASURE VOLTAGE BEFORE STARTING WORK.
<br />IF RESULT IS ANY OTHER VOLTAGE MEASURED THAN
<br />120/240V IS OBSERVED, DO NOT PROCEED. CONTACT
<br />ENGINEER.
<br />GROUNDING & GENERAL NOTES:
<br />1. A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [CEC
<br />690.47(C)(3)]
<br />2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE.
<br />3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING
<br />ELECTRODE
<br />4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS
<br />FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL
<br />INSPECTION.
<br />5. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE
<br />FIELD - JUNCTION BOX DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE
<br />TYPE TRANSITIONS.
<br />6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER
<br />AC DISCONNECTING MEANS IS LOCATED WITHIN 5' OF SERVICE DISCONNECT.
<br />7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE
<br />INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS.
<br />8. ALL NEW SERVICE INSTALLATIONS AND REPLACEMENTS REQUIRE A
<br />SURGE-PROTECTIVE DEVICE (SPD) IN ACCORDANCE WITH [CEC 230.67]. THE
<br />SPD SHALL BE TYPE 1 OR TYPE 2 AND IS REQUIRED TO BE AN INTEGRAL PART OF
<br />THE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO.
<br />INTERCONNECTION NOTES:
<br />1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE
<br />DETERMINED IN ACCORDANCE WITH [CEC 705.12], AND [CEC 690.64].
<br />2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [CEC 215.9],
<br />[CEC 230.95] AND [CEC 690.5]
<br />3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.
<br />4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE
<br />BUSBAR RELATIVE TO THE MAIN BREAKER.
<br />DISCONNECT NOTES:
<br />1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN
<br />THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE
<br />CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY
<br />THE UPPER TERMINALS)
<br />2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY
<br />PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH
<br />RACKING NOTES:
<br />1. BOND EVERY OTHER RAIL WITH #6 BARE COPPER
<br />QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT
<br />SIZE
<br />(2)
<br />N/A N/A
<br />(1)1 BARE COPPER IN FREE AIR
<br />PV WIRE/USE-2
<br />#6AWG -
<br />#10AWG -
<br />(2)#10AWG -CU,THWN-2
<br />EMT OR LFMC 3/4"(1)#8AWG -CU,THWN-2 GND2
<br />#10AWG -
<br />#10AWG -
<br />#10AWG -
<br />(2)CU,THWN-2
<br />(1)CU,THWN-2 N
<br />(1)CU,THWN-2 GND
<br />EMT,LFMC OR PVC3 3/4"
<br />#3AWG -
<br />#3AWG -
<br />#8AWG -
<br />(2)CU,THWN-2
<br />(1)CU,THWN-2 N
<br />(1)CU,THWN-2 GND
<br />EMT,LFMC OR PVC 1''4
<br />DC SYSTEM SIZE: 5.670 KW DC
<br />AC SYSTEM SIZE: 5.700 KW AC & 5.150 KW CEC AC
<br />14 JA SOLAR: JAM54S31 405/MR 405W MONO MODULES WITH
<br />14 SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS WITH
<br />01 SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER
<br />02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH
<br />BATTERY BAT-10K1P
<br />(01) STRING OF 14 MODULES ARE CONNECTED IN SERIES
<br />NOTE- RELOCATE ALL LOADS FROM
<br />MAIN PANEL TO BACKUP LOAD PANEL
<br /> ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE
<br />ENERGY SOURCE
<br />UTILITY SERVICE
<br />PV SYSTEM
<br />DISCONNECT # OF
<br />1 OF 2
<br />2 OF 2
<br />DISCONNECTION
<br />OPERATION/EQUIPMENT/DEVICE
<br />UTILITY - 200A MAIN BREAKER
<br />30A UTILITY NON-FUSED AC DISCONNECT
<br />D
<br />E
<br />#8AWG -
<br />#10AWG -
<br />(2)CU,THWN-2
<br />(1)CU,THWN-2 GND EMT,LFMC OR PVC 3/4''3A
<br />Green
<br />Building
<br />Engineer
<br />#832
|