Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />EL <br />V <br />I <br />S <br /> <br />M <br />A <br />R <br />T <br />I <br />N <br />E <br />Z <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />14 <br />2 <br />9 <br /> S <br />G <br />A <br />R <br />N <br />S <br />E <br />Y <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />ANSI B <br />11" X 17" <br />DATEDESCRIPTION <br />REVISIONS <br />PROJECT NAME & ADDRESS <br />DATE:05/05/2025 <br />DRAWN BY <br />ESR <br />MONA LEE SOLAR <br />WIRING <br />CALCULATIONS <br />PV-7 <br />PERCENT OF <br />VALUES <br />NUMBER OF CURRENT <br />CARRYING CONDUCTORS IN EMT <br />.80 4-6 <br />.70 7-9 <br />.50 10-20 <br />SOLAR MODULE SPECIFICATIONS <br /> MANUFACTURER / MODEL #JA SOLAR: JAM54S31 405/MR 405W PV <br />MODULES <br /> VMP 31.45V <br /> IMP 12.98A <br /> VOC 37.23V <br /> ISC 13.87A <br /> TEMP. COEFF. VOC -0.275%/°C <br /> MODULE DIMENSION 67.79"L x 44.64"W x 1.18"D (In Inch) <br />AMBIENT TEMPERATURE SPECS <br />RECORD LOW TEMP 2° <br />AMBIENT TEMP (HIGH TEMP 2%)39° <br />MODULE TEMPERATURE COEFFICIENT OF Voc -0.265%/°C <br />ELECTRICAL NOTES <br />1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. <br />3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE <br />TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. <br />5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, <br />FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. <br />6.WHERE SIZES OF JUNCTION BOX, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP <br />MANUFACTURER'S INSTRUCTION. <br />9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV <br />SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. <br />INVERTER SPECIFICATIONS <br /> MANUFACTURER / MODEL #SOLAREDGE TECHNOLOGIES LTD. <br />SE5700H-USMNBL75 (240V) INVERTER <br /> NOMINAL AC POWER 5.700 kW <br /> NOMINAL OUTPUT VOLTAGE 240 VAC <br /> NOMINAL OUTPUT CURRENT 24A