My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HISTORIC-606 S Van Ness Ave Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Van Ness Ave
>
606 S Van Ness Ave Unit# 2
>
HISTORIC-606 S Van Ness Ave Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:00:55 AM
Creation date
2/24/2026 5:00:15 AM
Metadata
Fields
Template:
Plan
Permit Number
101123709
Full Address
606 S Van Ness Ave Unit# 2
Street Number
606
Street Direction
S
Street Name
Van Ness
Street Suffix
Ave
Unit Number
2
Jump to thumbnail
< previous set
next set >
Stamp
ID:
1
Creator:
Import Agent
Created:
2/24/2026 5:00 AM
Modified:
2/23/2026 1:13 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
256
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SERVICE LOAD CALCULATION <br />TOTAL GENERAL LOAD :10,454VA <br />DWELLNG INFORMATION: <br />FLOOR AREA : <br />HEATER TYPE : <br />DRYER : <br />OVEN: <br />COOKTOP : <br />730 SQFT <br />GAS <br />GAS <br />N/A <br />GAS <br />GENERAL LOAD : <br />GENERAL LIGHTING(FLOOR AREA X 3VA/SFT) : <br />SMALL APPLIANCE(2-20ACK BY CEC210.11): <br />LAUNDRY(1-20ACKT BY CEC210.11) : <br />BATHROOM(1-20ACKT BY CEC210.11) : <br />DISHWASHER : <br />MICROWAVE OVEN : <br />GRABAGE DISPOSAL : <br />BATHROOM FANS : <br />GARAGE DOOR OPENER : <br />DRYER : <br />OVEN : <br />REFRIGERATOR : <br />COOKTOP : <br />2190VA <br />3000VA <br />1500VA <br />0VA <br />1500VA <br />0VA <br />864VA <br />400VA <br />0VA <br />0VA <br />0VA <br />1000VA <br />0VA <br />FIRST 10 KVA AT 100% : <br />REMAINDER AT 40% (454VA X O.4) : <br />SUBTOTAL GENERAL LOAD : <br />10000VA <br />182 VA <br />10,182 VA <br />AIR CONDITIONING KVA CALCULATION : <br />OUTDOOR CONDENSING UNIT : <br />INDOOR FANCOIL UNIT : <br />TOTAL AC LOAD : <br />4152VA <br />0VA <br />WATER HEATER : <br />CAR CHARGER : <br />0VA <br />0VA <br /> PROVIDED SERVICE RATING :100 AMPS <br />CALCULATED LOAD FOR SERVICE : <br />(10,182 VA+4,152 VA+0VA)/240V= 60 A(SERVICE RATING) <br />4152VA <br />GROUNDING <br />ELECTRODE <br />CONDUCTOR <br />GROUNDING <br />ELECTRODE <br />BOLTED-TYPE CONNECTION <br />DEVICE OR EXOTHERMIC WELD <br />NONMETALLIC PROTECTIVE <br />SLEEVE <br />NO. 4 AWG OR LARGER BARE <br />COPPER CONDUCTOR OR STEEL <br />REINFORCING BAR OR ROD NOT <br />LESS THAN 1/2" IN. DIAMETER <br />2 IN. <br />MINIMUM <br />CONCRETE FOUNDATION <br />20 FT <br />MINIMUM <br />1' <br />- <br />6 <br />" <br />3' <br />- <br />8 <br />" <br />4' <br />- <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />6' <br />- <br />6 <br />" <br />MI <br />N <br />. <br /> <br />7 <br />' <br /> <br />- <br />6 <br />" <br />FINISHED FLOOR <br />OUTLETS ABOVE THE FLOOR <br />LIGHT SWITCHES <br />OUTLETS ABOVE THE <br />COUNTERTOP <br />THERMOSTAT <br />ELECTRICAL PANEL <br />TO BE MOUNTED AT <br />HIGHEST POINT IN ROOMSD <br />NOTE : <br />COMBINATION SMOKE & CO <br />ALARMS <br />SMOKE ALARM SHALL BE <br />INTERCONNECTED HARDWIRED <br />WITH BATTERY BACKUP AND <br />SHALL BE INSTALLED IN <br />ACCORDANCE WITH NFPA 72. <br />CARBON MONOXIDE ALARM BE <br />INTERCONNECTED HARWARD <br />WITH BATTERY BACKUP <br />NOTE : <br />-SMOKE ALARM SHALL BE INSTALLED NOT LESS <br />THAN 3FT HORIZONTALLY FROM THE DOOR OF THE <br />BATHROOM PER 2022 CRC, SECTION R314.3. <br />-SMOKE ALARMS SHALL BE INSTALLED A MINIMUM <br />OF 20FT HORIZONTAL DISTANCE FROM A <br />PERMANENTLY INSTALLED COOKING APPLIANCE OR <br />PLEASE SHOW THAT IONIZATION OR <br />PHOTOELECTRIC SMOKE ALARMS SHALL BE <br />PROVIDED IN ACCORDANCE WITH 2022 CRC, <br />SECTION R314.3.3 ITEM 4 EXCEPTION. <br />NOTE : <br /> SCREENS OR OTHER DEVICES THAT <br />OBSTRUCT THE FLOW OF THE EXHAUST <br />DUCT SHALL NOT BE USED AT CLOTHES <br />DRYER EXHAUST DUCTS IN ACCORDANCE <br />WITH 2022 CMC, SECTION 504.4 <br />NOTE : <br />CLOTHES DRYER MOISTURE <br />EXHAUST DUCT MUST BE IN 4-IN. <br />IN DIAMETER AND LENGTH IN <br />LIMITED TO 14-FT. WITH 2 ELBOWS. <br />THE DUCT LENGTH SHALL BE <br />REDUCED BY 2-FT. FOR EVERY <br />ELBOW IN EXCESS OF TWO. <br />NOTE : <br />1. A RESERVED SINGLE POLE <br />CIRCUIT BREAKER SPACE SHALL <br />BE PROVIDED IN THE ELECTRICAL <br />PANEL ADJACENT TO THE CIRCUIT <br />BREAKER FOR THE BRANCH <br />CIRCUIT AND LABELED WITH THE <br />WORDS "FUTURE 240V USE." PER <br />2022 CALIFORNIA ENERGY CODE, <br />SECTION 150.0(N)1.A <br />NOTE : <br />GROUNDING ELECTRODE <br />SYSTEM FOR THE NEW <br />SUBPANEL SHALL BE PROVIDED <br />IN ACCORDANCE WITH 2022 CEC, <br />ARTICLE 250.32. <br />NOTE: <br />ADD DOUBLE PROTECTION <br />OUTLET AFCI AND GFCI PER <br />SECTION 210.8A 910 AND <br />210.12 OF CEC 2022 FOR <br />LAUNDRY AND KITCHEN AREA. <br />NOTE : <br />PANEL LOAD SCHEDULES <br />AND SINGLE LINE DIAGRAMS <br />TO BE PROVIDED DURING <br />INSPECTION. <br />NOTE : <br />PLUMBING INSPECTOR TO VERIFY IF GRIT TRAP FROM <br />PERFORATED PIPE REQUIRED PRIOR TO SS TIE IN. <br />LICENSE PLUMBER TO INCREASE GAS LINE IF REQUIRE <br />VERIFIED FIELD CONDITIONS, BENDS, LENGTH... IN FIELD <br />SD <br />REF. <br />SINK <br />DW <br />TANKLESS <br />WATER <br />HEATER <br />199,000BTU <br />MINI SPLIT <br />UNIT <br />LIGHT <br />LIGHT <br />3' <br />- <br />0 <br />" <br />3'-0" <br />3' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />EQEQ <br />3'-0" <br />3' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />3'-0" <br />EQ <br />EQ <br />GFCI GFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GFCI <br />GFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />FAN <br />VACANCY <br />SENSOR <br />FAN <br />15" <br />SMALL APPLIANCE <br />20 AMP <br />G.D <br />20A <br />42" <br />KITCHEN <br />HOOD <br />15" <br />42" <br />42" <br />220 <br />WP <br />WPWP <br />20A <br />42" <br />VACANCY <br />SENSOR <br />S/CSD <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />TV <br />/ <br />D <br />A <br />T <br />A <br />DELTA BREEZSLIM <br />70 CFM WITH HUMIDITY SENSOR <br />CFM EXHAUST BATH FAN, WHITE <br />NOTE : <br />EVERY KITCHEN SHALL HAVE HOOD TO THE <br />OUTSIDE OF THE BUILDING W/ MIN. LESS <br />THAN 750 SF REQUIRES 85% CE OR 280 CFM . <br />6” DIAM. EQUIPPED WITH BACKDRAFT <br />DAMPER, THAT HAS A MAXIMUM SOUND <br />RATING OF 3-SONES AND THE REQUIREMENT <br />FOR HERS VERIFICATION. <br />P. <br />L <br />. <br /> <br />5 <br />6 <br />. <br />3 <br />' <br />NOTE : <br />LUMINAIRES TO BE CONTROLLED <br />BY EITHER DIMMERS OR <br />VACANCY SENSORS IN DINING <br />ROOM AND LIVING ROOM. <br />NOTE : <br />WATER PIPING SHALL MEET THE INSULATION REQUIREMENTS OF 2022 CALIFORNIA <br />ENERGY CODE, SECTION 150.0(J)2.A. <br />ALL DOMESTIC HOT WATER PIPING SHALL BE INSULATED AS SPECIFIED IN SECTION 609.11 <br />OF THE CALIFORNIA PLUMBING CODE. IN ADDITION, THE FOLLOWING PIPING CONDITIONS <br />SHALL HAVE A MINIMUM INSULATION WALL THICKNESS OF 1 INCH OR A MINIMUM <br />INSULATION R-VALUE OF 7.7: <br />I. THE FIRST 5 FEET (1.5 METERS) OF COLD WATER PIPES FROM THE STORAGE TANK. <br />II. ALL HOT WATER PIPING WITH A NOMINAL DIAMETER EQUAL TO OR GREATER THAN 3/4 <br />INCH (19 MILLIMETER) AND LESS THAN 1 INCH. <br />III. ALL HOT WATER PIPING WITH A NOMINAL DIAMETER LESS THAN 3/4 INCH THAT IS: <br />A. ASSOCIATED WITH A DOMESTIC HOT WATER RECIRCULATION SYSTEM; <br />B. FROM THE HEATING SOURCE TO THE KITCHEN FIXTURES; <br />C. FROM THE HEATING SOURCE TO A STORAGE TANK OR BETWEEN STORAGE TANKS; <br />OR <br />D. BURIED BELOW GRADE. <br />GF <br />C <br />I <br />WP3D <br />AFCIAFCI <br />P-SWP <br />WP WP <br />CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT <br />DOES NOT OVERRIDE TO ON THE AUTOMATIC ACTIONS OF <br />ITEMS B) OR C) BELOW; AND <br />B) CONTROLLED BY PHOTOCELL AND MOTION SENSOR. <br />CONTROLS THAT OVERRIDE TO ON SHALL NOT BE ALLOWED <br />UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE <br />MOTION SENSOR WITHIN 6 HOURS; OR CONTROLLED BY <br />ONE OF THE FOLLOWING METHODS: <br />I) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL. <br />II) ASTRONOMICAL TIME CLOCK. <br />III) ENERGY MANAGEMENT CONTROL SYSTEM. <br />KITCHEN <br />LIVING ROOM <br />MASTER BEDROOM <br />BATH <br />WALK IN CLOSET <br />DINING ROOM <br />MASTER BATH <br />STACK. <br />LAUNDRY <br />BEDROOM #2 <br />CLOSET <br />ENTRY <br />3' <br />- <br />0 <br />" <br />EQ <br />EQ <br />3'-0" <br />72" <br />GFCIWP <br />(E) AVOCADO TREE <br />(N) WALKWAY <br />(N) CONCRETE PAD <br />3D <br />20A <br />MINI SPLIT <br />BLOWER MINI SPLIT <br />BLOWER <br />MINI SPLIT <br />BLOWER MINI SPLIT <br />BLOWER <br />SYMBOLS <br /> <br /> <br />SINGLE POLE SWITCH SCONCE FIXTURE: UP LIT - LED <br />D= DIMMER <br />V = MANUAL ON, AUTO OFF SCONCE: UP AND DOWN LIT - LED <br />WP = WATER PROOF <br />T = TIMER SWITCH <br />THREE-WAY DIMMER SWITCH FLUORESCENT FIXTURE <br /> <br />SINGLE OUTLET EXHAUST FAN w/100 CFM MIN. <br /> FAN w/100 CFM MIN. <br />EXTERIOR LIGHT V = W/ MANUAL ON, AUTO OFF <br /> H = W/ AUTO ON HUMIDISTAT SENSOR <br />DUPLEX OUTLET EXHAUST FAN w/50 CFM MIN. <br />WP = WATER PROOF V = MANUAL ON, AUTO OFF <br />GFCI = GROUND FAULT CIRCUIT INTER. H = W/ AUTO ON HUMIDISTAT SENSOR <br />AFCI = ARC FAULT CIRCUIT INTER. <br />USB <br />QUADROPOLE OUTLET SURFACE MOUNTED FIXTURES <br /> M = MOTION SENSOR <br /> P = MOTION SENSOR W/ PHOTO SENSE <br /> E = HIGH EFFICIENCY <br />WALL MOUNTED LAMP LV = LOW VOLTAGE <br />MOTION SENSOR/PHOTOCELL. <br /> SPEAKER <br />220V OUTLET RECESSED FIXTURE-LED <br />R = RANGE OUTLET <br />D = CLOTHES DRYER OUTLET <br />H = RADIANT HEATER H3 WALL MOUNTED FIXTURE - LED <br /> <br />SPECIAL-PURPOSE OUTLET HOME SECURITY PANEL <br />DW = DISHWASHER OUTLET <br />GD = GARBAGE DISPOSAL <br />S = STEAM SHOWER SMOKE DETECTOR <br /> CARBON MONOXIDE DETECTOR <br /> <br />CLOCK OUTLET SMOKE & CARBON MONOXIDE DETECTOR <br /> <br />EXIT LIGHT OUTLET HOSE BIB <br />DATA OUTLET 1.SWITCHES TO BE 42" ABV. FF UON <br />T = TELEPHONE 2. OUTLETS TO BE 15" ABV. FF UON <br />TV = TELEVISION 3. OUTLETS ABV. COUNTER TOPS TO BE <br />EN = ETHERNET 42" ADV. FF UON <br />M = MULTI (TELE./TV/EN) <br />J BOX COVE LIGHTING <br />CAMERA DIFFUSER <br />RECESSED LINEAR LIGHT VACANCY SENSOR <br />CL <br />. <br />C <br />SD <br />S <br />HB <br />3D <br />W <br />PP <br />- <br />S <br />S/C <br />R <br />0 1'-4"2'-8"5'-4" <br />SCALE: 3/8" = 1'-0" <br />DATE: <br />P.M.: <br />DRAWN BY: <br />JOB NO.: <br />26081 Merit Cir, STE 111 <br />Laguna Hills, CA 92653 <br />909-257-7040 WWW.BNDESIGNBUILDINC.COM <br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN <br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK <br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. <br />D ES I GNBUILDCNI <br />7/ <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />1 <br />0 <br />: <br />2 <br />9 <br />: <br />2 <br />2 <br /> <br />A <br />M <br />A2.3 <br />B.N. <br />F.M. <br />ELECTRICAL <br />PLAN <br />07.11.24 <br />2024001108 <br />UNIT 2, 606 S VAN <br />NESS AVE, <br />SANTA ANA, CA <br />92701 <br />ACCESSORY <br />DWELLING <br />UNIT <br /> 3" = 1'-0"2 GROUNDING ELECTRODE <br /> 3/8" = 1'-0"1 ELECTRICAL PLAN <br />1. FRIDGE (20 AMP) <br />2. COOKTOP/RANGE (20 AMP, 120/240V) <br />3. RANGE HOOD (15-20 AMP) <br />4. COUNTERTOP RECEPTACLES (2 CIRCUITS, 20 AMP) <br />5. KITCHEN LIGHTING (15-20 AMP) <br />6. EACH ROOM/HALLWAY SHALL HAVE SEPARATE CIRCUITS FOR LIGHTS AND <br />RECEPTACLES (20 AMP) <br />7. WALL MOUNTED AIR CONDITIONERS (20 AMP EACH) <br />8. BATHROOM RECEPTACLES AND LIGHTS (20 AMP) <br />9. BATHROOM FAN (20 AMP) <br />10. DINING ROOM: SEPARATE (20 AMP) CIRCUIT FOR ENTERTAINMENT CENTER <br />11. WASHER AND DRYER (GAS: 20 AMP OR ELECTRIC: 30 AMP) <br />FIXTURE MOUNTING HEIGHTS <br />1. WHOLE BUILDING VENTILATION PER ASHRAE STANDARD 62.2, SOLUTION: EXHAUST VENTILATION THROUGH BATHROOM FAN(S). <br />2. THE BATH FAN(S) RUNS INTERMITTENTLY ON A TIMER (100 CFM EVERY 4 HOURS FOR 1 HOUR, WITH MANUAL OVERRIDE) AND WHILE IT IS RUNNING, <br />FRESH AIR SHALL BE PULLED FROM THE OUTSIDE. <br />HEATING AND COOLING: <br />1. INSTALL MINI SPLIT OUTDOOR COMPRESSOR AND INDOOR WALL UNITS. <br />2. UNITS LOCATION PER ELECTRICAL PLAN. <br />3. INSTALLATION, PIPING AND CLEARANCES ACCORDING TO MANUFACTURER'S RECOMMENDATIONS <br />ELECTRICAL SYSTEM TO BEELECTRICAL SYSTEM TO BE <br />INSTALLED WITH SEPARATECIRCUITS FOR:INSTALLED WITH SEPARATECIRCUITS FOR: <br />METHOD OF VENTILATION:METHOD OF VENTILATION: <br />NOTE : <br />WATER PIPING SHALL MEET THE INSULATION <br />REQUIREMENTS OF 2022 CALIFORNIA ENERGY CODE, <br />SECTION 150.0(J)2.A. <br />ALL DOMESTIC HOT WATER PIPING SHALL BE <br />INSULATED AS SPECIFIED IN SECTION 609.11 OF THE <br />CALIFORNIA PLUMBING CODE. IN ADDITION, THE <br />FOLLOWING PIPING CONDITIONS SHALL HAVE A <br />MINIMUM INSULATION WALL THICKNESS OF 1 INCH <br />OR A MINIMUM INSULATION R-VALUE OF 7.7: <br />I. THE FIRST 5 FEET (1.5 METERS) OF COLD WATER <br />PIPES FROM THE STORAGE TANK. <br />II. ALL HOT WATER PIPING WITH A NOMINAL <br />DIAMETER EQUAL TO OR GREATER THAN 3/4 INCH (19 <br />MILLIMETER) AND LESS THAN 1 INCH. <br />III. ALL HOT WATER PIPING WITH A NOMINAL <br />DIAMETER LESS THAN 3/4 INCH THAT IS: <br />A. ASSOCIATED WITH A DOMESTIC HOT WATER <br />RECIRCULATION SYSTEM; <br />B. FROM THE HEATING SOURCE TO THE KITCHEN <br />FIXTURES; <br />C. FROM THE HEATING SOURCE TO A STORAGE <br />TANK OR BETWEEN STORAGE TANKS; OR <br />D. BURIED BELOW GRADE. <br />NOTE : <br />PLUMBING INSPECTOR TO VERIFY IF GRIT TRAP <br />FROM <br />PERFORATED PIPE REQUIRED PRIOR TO SS TIE IN. <br />LICENSE PLUMBER TO INCREASE GAS LINE IF <br />REQUIRE VERIFIED FIELD CONDITIONS, BENDS, <br />LENGTH... IN FIELD <br />GENERAL ELECTRICAL NOTES FOR <br />NEW DETACHED RESIDENTIAL <br />1. WATER HEATING SYSTEM (WATER HEATER) – (SECTION 150.0(N)) <br />A. SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE <br />INDIVIDUAL DWELLING UNITS SHALL DESIGNATE A SPACE AT LEAST 2.5 <br />FEET BY 2.5 FEET WIDE AND 7 FEET TALL SUITABLE FOR THE FUTURE <br />INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH) BY MEETING <br />EITHER A OR B LISTED UNDER SECTION 150.0(N). <br />I. IF THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER: <br />A. A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE THAT IS <br />CONNECTED TO THE ELECTRIC PANEL WITH A 120/240 VOLT 3 CONDUCTOR, <br />10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER <br />HEATER. <br />II. ISOLATE BOTH ENDS OF THE UNUSED CONDUCTOR. <br />B. A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL <br />PANEL ADJACENT TO THE CIRCUIT BREAKER <br />C. A CONDENSATE DRAIN THAT ALLOWS NATURAL DRAINING OF THE <br />WATER HEATER. <br />D. . IF THE DESIGNATED SPACE IS MORE THAN 3 FEET FROM THE WATER <br />HEATER: SEE ADDITIONAL CODE REQUIREMENTS. <br />B. WHEN A SECOND WATER HEATER IS INSTALLED AS PART OF THE <br />ADDITION SHALL COMPLY WITH SECTION (150.2(A)(D). ENERGY STORAGE <br />SYSTEM (ESS) READY: ALL SINGLE-FAMILY RESIDENCES THAT INCLUDE <br />ONE OR TWO DWELLING UNITS, AND ADU SHALL MEET THE FOLLOWING: <br />A. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br />I. ESS READY INTERCONNECTION EQUIPMENT [AUTO TRANSFER SWITCH <br />AND PANEL] WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A <br />MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, OR <br />II. A DEDICATED, MINIMUM 1” RACEWAY FROM THE MAIN SERVICE TO A <br />SUBPANEL THAT SUPPLIES THE BRANCH CIRCUITS IN SECTION 150.0(S)(2). <br />B. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE SUPPLIED BY THE ESS: <br />THE REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE <br />PRIMARY EGRESS, AND AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING <br />ROOM RECEPTACLE OUTLET. <br />C. THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 <br />AMPERES WITH SPACE TO INSTALL FUTURE ISOLATION <br />EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET. HEAT PUMP SPACE <br />HEATER (FURNACE) READY: SYSTEM USING GAS FURNACE TO SERVE <br />INDIVIDUAL DWELLING UNITS SHALL INCLUDE A DEDICATED 240 VOLT, <br />MINIMUM 30 AMPS BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3- <br />FT FROM THE FURNACE FOR A FUTURE HEAT PUMP SPACE HEATER <br />INSTALLATION. ELECTRIC COOKTOP READY: SYSTEM USING GAS TO SERVE <br />INDIVIDUAL DWELLING UNITS SHALL INCLUDE A DEDICATED 240 VOLT, <br />MINIMUM 50 AMPS CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3-FT FROM <br />THE COOKTOP FOR A FUTURE ELECTRIC COOKTOP INSTALLATION. <br />ELECTRIC CLOTHES DRYER READY: CLOTHES DRYER USING GAS TO SERVE <br />INDIVIDUAL DWELLING UNITS SHALL INCLUDE A DEDICATED 240 VOLT, <br />MINIMUM 30 AMPS BRANCH CIRCUIT WIRING SHALL BE INSTALLED 3-FT <br />FROM THE CLOTHES DRYER LOCATION FOR A FUTURE ELECTRIC CLOTHES <br />DRYER INSTALLATION. <br />REV DATE REMARKS <br />2 06.25.2025 City Correction <br />2 2 <br />22