EX. WALL TO REMAIN <br />EX. WALL TO BE REMOVED <br />AREA NOT IN <br />CONTRACT (N.I.C.) <br />EX. DOOR TO REMAIN <br />1 <br />2 <br />3 <br />INTERIOR WALL <br />1 HOUR FIRE <br />RATED WALL <br />EXTERIOR WALL <br />FLOOR <br />CEILING <br />ROOF <br />2 <br />B <br />3 <br />C <br />1 <br />A <br />TYPICAL, FIRE RATED WALL <br />2X4 WOOD STUDS @ 16" O.C. w/ 5/8" <br />TYPE 'X' GYP. ONE. SIDE W/ SOUND <br />INSULATION <br />INTERIOR WALL <br />2X4 WOOD STUDS @ 16" O.C. w/ 1/2" <br />BD. EA. SIDE w/ SOUND INSULATION <br />EXTERIOR WALL <br />1/2" GYP. BD. 2X4 WOOD STUDS @ 16" <br />O.C. INSULATION R -15 w/ 5/8" <br />PLYWOOD, 1" RIGID INSULATION, <br />BUILDING 2 LAYERS PAPER, AIR SPACE, <br />WOOD SIDING <br />(E) <br />ELECTRICAL <br />PANEL <br />100 AMP <br />(E) WOOD <br />FENCE, 6' H. <br />(E) WOOD <br />FENCE, 6' H. <br />(E) BLOCK <br />FENCE, 6' H. <br />(E) BLOCK <br />FENCE, 6' H. <br />(E) COVERED STORAGE <br />P. <br />L <br />. <br /> <br />5 <br />6 <br />. <br />3 <br />' <br />(E) AVOCADO TREE <br />(E) TREE <br />(E) TREE <br />8' <br />- <br />6 <br />" <br />17 <br />' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />WALL SEPARATION <br />5'-0" <br />WA <br />L <br />L <br /> <br />S <br />E <br />P <br />A <br />R <br />A <br />T <br />I <br />O <br />N <br />15 <br />' <br />- <br />0 <br />" <br />SETBACK <br />5'-0"22'-9 1/2" <br />WALL SEPARATION <br />15'-0" <br />SE <br />T <br />B <br />A <br />C <br />K <br />25 <br />' <br />- <br />3 <br />" <br />11 <br />' <br />- <br />0 <br />" <br />11 <br />' <br />- <br />0 <br />" <br />11'-5" <br />5'-0" <br />3'-4 1/2" <br />9'-2" <br />3'-4 1/2" <br />8'-9" <br />7'-10" <br />3' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />TEMP. GLASS <br />2' <br />- <br />0 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />6' <br />- <br />9 <br />" <br />4' <br />- <br />3 <br />" <br />KITCHEN <br />LIVING ROOM <br />MASTER BEDROOMBATH <br />WALK IN CLOSET <br />DINING ROOM <br />MASTER BATH <br />STACK. <br />LAUNDRY <br />REF. <br />SINK <br />DW <br />7' <br />- <br />8 <br />" <br />9'-5" <br />8'-2 1/2"3'-0"2'-6"5"2'-6"1'-0"4'-0"1'-6 1/2"3'-0"4"3'-0"1'-6 1/2" <br />3' <br />- <br />1 <br />1 <br />" <br />3' <br />- <br />0 <br />" <br />1' <br />- <br />7 <br />" <br />25 <br />' <br />- <br />9 <br /> <br />1 <br />/ <br />2 <br />" <br />SE <br />T <br />B <br />A <br />C <br />K <br />5' <br />- <br />0 <br />" <br />31'-0" <br />SETBACK <br />5'-0" <br />1'-8 1/2"3'-0"4"3'-0"5'-8 1/2"2'-0"7'-0 1/2"3'-0"4"3'-0"1'-10 1/2" <br />TV <br />LANDING <br />3' <br />- <br />0 <br />" <br />BEDROOM #2 <br />A3 <br />. <br />1 <br />1 <br />A3 <br />. <br />1 <br />2 <br />A3 <br />. <br />0 <br />1 <br />A3 <br />. <br />0 <br />2 <br />2'-0"2'-10"3'-0" <br />5' <br />- <br />0 <br />" <br />1'-7 1/2" <br />CLOSET <br />3'-10"2'-0"2'-4" <br />TEMP. <br />GLASS <br />DS DS <br />DS <br />DS <br />DS <br />(N) WALKWAY <br />ALL NONABSORBENT SURFACE MATERIAL <br />SHALL EXTEND TO A HEIGHT OF NOT <br />LESS THAN 6 FT ABOVE THE FLOOR <br />1/2" <br />THRESHOLD <br />SAFETY <br />GLAZING <br />NOTE: <br />IF SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, <br />THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR <br />OTHER SHOWER OUTLETS CONTROL BY A SINGLE VALVE <br />SHALL NOT EXCEED 1.8 GPM AT 80 PSI. OR THE SHOWER <br />SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET <br />TO BE IN OPERATION AT A TIME. <br />SINK CENTERED TO <br />KITCHEN WINDOW, <br />CONTRACTOR TO VERIFY <br />03 <br />02 <br />03 <br />03 <br />02 <br />02 <br />02 <br />01 <br />05 <br />04 <br />06 <br />03 <br />05 <br />02 <br />07 <br />01 01 03 03 <br />01 <br />02 <br />0101020101 <br />DROPPED <br />CEILLING 8'-0" <br />EGRESS EGRESS <br />SAFETY GLAZINGSAFETY GLAZING <br />SAFETY <br />GLAZING <br />SAFETY <br />GLAZING <br />SAFETY <br />GLAZING <br />TANKLESS <br />WATER <br />HEATER <br />199,000BTU <br />ALL NONABSORBENT SURFACE <br />MATERIAL SHALL EXTEND TO A <br />HEIGHT OF NOT LESS THAN 6 FT <br />ABOVE THE FLOOR <br />THE INTERIOR FINISHED FLOOR SHALL BE NOT <br />MORE THAN 1/2" LOWER THAN THE TOP OF THE <br />DOOR THRESHOLD. EXTERIOR DOOR LANDING <br />SHALL BE NOT MORE THAN 73/4IN BELOW THE <br />TOP OF THE DOOR THRESHOLD PER 2022 CRC, <br />SECTION R311.3.1 <br />2.462.46 <br />2.17 <br />2.18 <br />2.182.93 <br />2.14 <br />2.15 <br />LOUVER <br />DOOR <br />2.51 <br />2.50 <br />03 <br />3' <br />- <br />0 <br />" <br />8' <br />- <br />0 <br />" <br />(N) CANOPY <br />TREES <br />4'-0" <br />(N) CONCRETE PAD <br />MINI SPLIT <br />1 <br />A3.2 <br />ENTRY <br />SD <br />S/CSD <br />NATURAL LIGHT 8% REQUIRED <br />100 SQ. FT. X 8%= 8 SQ. FT. <br />WINDOW 01 X 2 = 24 SQ. FT. PROVIDED <br />NATURAL VENTILATION 4% REQUIRED <br />100 SQ. FT. X 4%= 4 SQ. FT. <br />WINDOW 01 X 2 = 24 SQ. FT. PROVIDED <br />24 SQ. FT. X 50%= 12 SQ. FT. PROVIDED <br />NATURAL LIGHT 8% REQUIRED <br />110 SQ. FT. X 8%= 8.8 SQ. FT. <br />WINDOW 01 X 2 = 24 SQ. FT. PROVIDED <br />NATURAL VENTILATION 4% REQUIRED <br />115 SQ. FT. X 4%= 4.4 SQ. FT. <br />WINDOW 01 X 2 = 24 SQ. FT. PROVIDED <br />24 SQ. FT. X 50%= 12 SQ. FT. PROVIDED <br />(N) CANOPY <br />TREES <br />2'-6" <br />2' <br />- <br />6 <br />" <br />ENCLOSURE OF <br />WATER HEATER <br />ELECTRICAL <br />SUB PANEL <br />100A <br />3' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />9'-4 1/2"6'-8" <br />13 <br />' <br />- <br />6 <br />" <br />21'-10 1/2" <br />3' <br />- <br />0 <br />" <br />4" SLAB UNDER MINI SPLIT UNIT <br />03 <br />2 <br />A3.2 <br />2'-6"1' <br />- <br />1 <br />0 <br />" <br />ATTIC <br />ACCESS <br />MINI SPLIT <br />BLOWER <br />MINI SPLIT <br />BLOWER <br />MINI SPLIT <br />BLOWER <br />MINI SPLIT <br />BLOWER <br />COMMON AREA = 400 SQ.FT <br />PRIVATE AREA = 330 SQ.FT TOTAL AREA = 730 SQ.FT <br />DATE: <br />P.M.: <br />DRAWN BY: <br />JOB NO.: <br />26081 Merit Cir, STE 111 <br />Laguna Hills, CA 92653 <br />909-257-7040 WWW.BNDESIGNBUILDINC.COM <br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN <br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK <br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. <br />D ES I GNBUILDCNI <br />7/ <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />1 <br />0 <br />: <br />2 <br />9 <br />: <br />1 <br />9 <br /> <br />A <br />M <br />A2.2 <br />B.N. <br />F.M. <br />ADU FLOOR PLAN <br />07.11.24 <br />2024001108 <br />UNIT 2, 606 S VAN <br />NESS AVE, <br />SANTA ANA, CA <br />92701 <br />ACCESSORY <br />DWELLING <br />UNIT <br />0 1'-4"2'-8"5'-4" <br />SCALE: 3/8" = 1'-0" <br />2.14 36" GAS RANGE / OVEN AND OVERHEAD EXHAUST HOOD VENTED TO EXTERIOR <br />SEE MECHANICAL NOTES ON SHEET A0.2 FOR ADDITIONAL VENTING <br />REQUIREMENTS <br />2.15 36" KITCHEN SINK WITH GARBAGE DISPOSAL - VERIFY DIMENSIONS WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />2.17 LAUNDRY-APPLIANCES, CABINETS AND FIXTURES AS SELECTED BY OWNERS, <br />INSTALL ENERGY STAR WASHERS DRYERS AS SELECTED BY OWNERS. <br />WASHING MACHINE SHALL MEET CEE TIER 2 REQUIREMENTS (MODIFIED <br />ENERGY FACTOR 20, WATER FACTOR 60).SEE INTERIOR DESIGN/CABINET <br />CONSUL TANT DRAWINGS FOR ADDITIONAL INFORMATION. INSTALL UTILITIES <br />FOR LAUNDRY APPLIANCES. SEE UTILITY PLANS FOR ADDITIONAL <br />INFORMATION. PROVIDE ELEVATED COUNTER OVER TOP OF FRONT LOADING <br />WASHER/DRYER AS REQUIRED COORDINATE WITH CABINET SUB <br />2.18 BATHROOMS: ALL FIXTURES AND FINISHES AS SELECTED. TANK TYPE <br />PORCELAIN WATER CLOSET . ENAMEL LAVS. PROVIDE PLUMBING PER CODE <br />FOR ALL FIXTURES AND SEPARATE SHOWER. MIRROR OVER LAVS AS <br />SELECTED BY INTRIOR DESIGN CONSULTANT OR CONTRACTOR. <br />2.46 DOWNSPOUT <br />2.50 PROPOSED NEW CLOSET DOOR <br />2.51 PROPOSED NEW POCKET DOOR <br />2.93 30" BUILT- IN ENERGY STAR REFRIGERATOR W/ WATER LINES FOR ICEMAKERS <br />GENERAL NOTES <br />1- CONTRACTOR SHALL NOT SCALE , DRIVER OR REQUEST DIMENSIONS FROM THE STRUCTURAL <br />ENGINEER, <br />PLUMBING ENGINEER,CIVIL ENGINEER OR ELECTRICAL ENGINEER... FOR ANY ITEMS ON THE <br />DOCUMENTS. <br />ALL DIMENSIONS NEEDED WILLBE REQUESTED OF THE DESIGNER IN WRITING IN THE FORM OF AN <br />RFI.(FAILURE TO <br />ADHERE TO THIS PROCESS WILLRESULT IN DENIAL OF CHANGE ORDERS ) <br />2- GENERAL CONTRACTOR SHALL NOT EXCLUDE (ANY) PORTION OF WORK, OR RELATED WORK FOR <br />(ANY)PORTION OF THE WORK SHOWN OR REFERENCED ON THE DOCUMENTS. <br />A. ALL DIMENSIONS FOR THE PROJECT SHALL BE OBTAINED FROM THE DESIGNERURAL DRAWING,IN THE <br />EVENT THAT THEY ARE NOT PROVIDED THE GC SHALL ASK THE DESIGNER IN WRITING IN THE FORM OF <br />AN RFI. <br />B. IN THE EVENT OF ANITEM BEING UNCLEAR ON THE DRAWINGS DURING BIDDING,THE GC SHALL ASK(IN <br />A BID RFI)TO THE DESIGNER FOR THE INFO, THE GC SHALL ASK THIS INFO IN A TIMLY MANNER SO AS TO <br />GIVE THE DESIGNER TIME TO ANSWER AND DISTRIBUTETO ALL PARTIES. IN TEH EVENT THAT THE GC <br />FAILS TO CLARIFY THIS INFO DUE TO OVERLOOKING IT OR NOT RECEIVING AN ANSWER FORM <br />THEDESIGNER, GC SHALL IDENTIFY THE ITEM/S IN QUETION IN THEIR BID CLARIFICATIONS. <br />C. GC SHALL REVIEW ALL SUBCONTRACTOR SCOPE TO THE FULL-SET OF DOCUMENTS,IT IS GC <br />RESPONSIBILITY TO UNDERSTAND AND DISCUSS SUB-CONTRACTOR SCOPE ATTHE TIME OF BID TO THE <br />POINT THAT THEY FEEL COMFOR TABLE THAT THE DRAWING INTENT HAS BEEN SATISFIED. ANY <br />UNCLEAR ITEMS SHALL BE DISCUSSED WITH THE SUBCONTRACTOR TO CLARIFY THE NEED FOR A BID <br />RFI <br />3- ALL DIMENSIONS ARE TO STRUCTURE-FACE OF STUD OR STRUCTURE CONCRETE WALL. <br />4- GENERAL CONTRACTOR TO VERIFY ALL DOOR FRAME WIDTHS,COORDINATE WITH WALL TYPE <br />SCHEDULE FOR WALL THICKNESS REFER TO DOOR SCHEDULE. <br />5-PROVIDE OPENING FOR DOOR SIZE SCHEDULE, JAMBS ARE FLUSH AS SHOWN OR AS DIMENSIONED <br />GREEN CODE BUILDING <br />1. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE <br />MINIMUM FLOW RATES IN TABLE 4.303.2/TABLE 9.403.2. (4.303.1 <br />PLUMBING NOTES <br />1. PROVIDE A NON-REMOVABLE BACKFLOW PREVENTION DEVICE ON <br />ALL EXTERIOR HOSE BIBS, AND LAWN SPRINKLER / IRRIGATION <br />SYSTEMS. <br />WALL LEGEND <br />FLOOR PLAN GENERAL NOTES:FLOOR PLAN GENERAL NOTES: <br />1. SEE SHEET A4.0 FOR ASSEMBLIES AND ROOM FINISH, WINDOWS, DOORS SCHEDULE. <br />2. SEE SHEET A2.2 FOR ELECTRICAL APPLIANCE SCHEDULE. <br />3. SMOKE ALARM SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP AND SHALL BE <br />INSTALLED IN ACCORDANCE WITH NFPA 72. <br />4. CARBON MONOXIDE ALARM SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP. <br />ATTIC ACCESS: <br />1. 22"X30" MIN. W/ WEATHER-STRIP OR SEAL TO PREVENT DRAFTS. DOUBLE FRAMING <br />PERPENDICULAR TO ROOF RAFTER TIES'/CEILING JOISTS' SPAN. <br />ROOF PLAN GENERAL NOTES: <br />1. NOT IN USED. <br />2. FOR PLUMBING AND/OR DUCTING VENTS, IF APPLICABLE, INSTALL GALVANIZED IRON ROOF <br />JACKS, AS REQUIRED. <br />PROPOSED KEYNOTES <br /> N <br />O <br />R <br />T <br />H <br /> 3/8" = 1'-0"1 ADU FLOOR PLAN <br />AGING-IN-PLACE REQUIREMENTS <br />A. REINFORCEMENT FOR GRAB BAR INSTALLATION FOR BATHROOMS SHALL BE PROVIDED. (R327.1.1) <br />I. AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH <br />REINFORCEMENT INSTALLED. IF THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE ON THE SECOND OR <br />THIRD FLOOR OF THE DWELLING SHALL COMPLY. <br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING <br />AGENCY. <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER OR OTHER CONSTRUCTION MATERIAL <br />PROVIDING EQUAL HEIGHT AND LOAD <br />CAPACITY. <br />3. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39¼ INCHES ABOVE FINISHED FLOOR FLUSH WITH THE <br />WALL FRAMING. <br />4. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL <br />AND THE BACK WALL. <br />5. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />6. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE <br />BATHTUB AND THE BACK WALL. <br />ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE <br />LOCATED NO MORE THAN 6 INCHES <br />ABOVE THE BATHTUB RIM. <br />B. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE USED BY OCCUPANTS SHALL BE <br />LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES <br />MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR UNLESS EXCEPTION MET. (R327.1.2) <br />C. INTERIOR DOOR WIDTH (AT LEAST ONE BEDROOM DOOR AND ONE BATHROOM DOOR WITH 32 ” CLEAR OPENING), <br />EFFECTIVE JULY 1, 2024 (R327.1.3) <br />D. DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES ABOVE EXTERIOR FLOOR OR <br />LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL HEIGHT REQUIREMENT <br />CANNOT BE MET FOR INTEGRATED DOORBELL FEATURES, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO <br />BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE <br />TOP OF THE DOORBELL BUTTON OR CONTROL. <br />REV DATE REMARKS <br />1 10.03.2024 City Correction <br />2 06.25.2025 City Correction <br />2 <br />2 <br />2 <br />2 <br />2 <br />22 <br />2 <br />2