CITY OF SANTA ANA <br />gency I <br />18'-0" <br />n <br />OExisting Floor plan <br />1 /4" = 1'-0" <br />ARCHITECTURAL NOTES <br />1. PROVIDE 72" HIGH NON ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED <br />SHATTER RESISTANT MATERIALS FOR SHOWER ENCLOSURE. MATERIALS OTHER THAN <br />STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT. <br />2. SIZE OF SHOWER STALL TO COMPLY WITH CPC 412.7, 1024 SQ. IN. MINIMUM INTERIOR <br />AND ENCOMPASSING 30" CIRCLE. DOOR SHALL SWING TO THE OUTSIDE. <br />3. LOW FLOW TOILETS (1.28 GALLON/FLUSH) - SHOWERHEADS (2.0 GPM @ 80 PSI) <br />- FAUCETS (2.0 GPM @ 60 PSI) <br />4. PROVIDE INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE <br />THERMOSTATIC MIXING VALVE TYPE FOR SHOWERS AND TUB SHOWERS. <br />5. PROVIDE WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM OF <br />4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS. <br />6. DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE. <br />7. CLOTHES DRYER MOISTURE EXHAUST DUCT IS LIMITED TO 14 FEET WITH 2 ELBOWS <br />FROM THE CLOTHES DRYER TO POINT OF TERMINATION REDUCE THIS LENGTH BY 2 FEET <br />FOR EVERY ELBOW IN EXCESS OF 2. <br />8. UNIT SKYLIGHTS SHALL BE LABELED BY L.A CITY APPROVED LABELING AGENCY.SUCH <br />LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND <br />PERFORMANCE GRADE RATING. <br />10. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING <br />SHOWER HEADS AND TOILETS MUST BE UPDATED FOR LOW WATER CONSUMPTION. <br />11. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND UNOBSTRUCTED <br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, <br />TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE <br />LOCATION OF THE HOOK UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY <br />POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO <br />COMPLY MAY CAUSE CONSTRUCTION DELAYS AND OR ADDITIONAL EXPENSES. <br />12. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE <br />ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE <br />EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. <br />13. NEW OR REPLACEMENT WATER HEATERS SHALL BE STRAPPED TO THE WALL IN TWO <br />PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND ONE IN THE LOWER 1/3 OF THE TANK. THE <br />LOWER POINT SHALL BE A MINIMUM OF 4" ABOVE THE CONTROLS. (P.C.510.5) LOW IN EXCESS <br />OF 2. <br />14. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR <br />TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3). <br />15. KITCHEN SINK LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND <br />WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND <br />CONNECTED TO AN APPROVED WATER SUPPLY (R306.4). <br />16. BATHTUB AND SHOWER FLOORS, WALL ABOVE BATHTUBS WITH A SHOWERHEAD, AND <br />SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH <br />WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6' ABOVE THE FLOOR <br />(R307.2). <br />17. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH <br />NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION <br />R303.1 OR SHALL BR PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN <br />AVERAGE ILLUMINATION OF 6' CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" <br />ABOVE THE FLOOR LEVEL. (R303.1) <br />18. A COPY OF THE EVALUATION REPORT AND/ OR CONDITIONS OF LISTING SHALL BE <br />MADE AVAILABLE AT THE JOB SITE. <br />19. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMP' OF 68°F AT A <br />POINT T ABOVE THE FLOOR AND 2' FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE <br />DESIGN TEMPERATURE. <br />20. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE <br />PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY <br />DURABLE WOOD OR WOOD THAT IS PRESERVATIVE TREATED IN ACCORDANCE WITH AWPA <br />U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE.PRESERVATIVES SHALL BE <br />LISTED IN SECTION 4 OF AWPA U1. <br />21. PROVIDE ANTI -GRAFFITI FINISH WITHIN THE FIRST 9 FEET,MEASURED FROM GRADE,AT <br />EXTERIOR WALLS AND DOORS EXCEPTION: MAINTENANCE OF BUILDING AFFIDAVIT IS <br />RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF LOS ANGELES TO <br />REMOVE ANY GRAFFITI WITHIN 7 DAYS OF THE GRAFFITI BEING APPLIED.(6306) <br />ADDITIONAL NOTES: <br />1. CONSTRUCTION SHALL NOT RESTRICT A FIVE- FOOT CLEAR AND UNOBSTRUCTED ACCESS TO <br />ANY WATER OR POWER DISTRIBUTION FACILITIES OR TO THE LOCATION OF THE HOOK-UP. <br />THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES -WHETHER OR <br />NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE <br />CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. <br />2. HABITABLE SPACES SHALL HAVE CEILING HEIGHT OF NO LESS THAN T-6". KITCHENS, LAUNDRY <br />ROOM, CORRIDORS AND BATHROOMS SHALL HAVE CEILING HEIGHT NOT LESS THAN 7'. <br />3. PROVIDE 1 ESCAPE WINDOW IN EACH BEDROOM MEETING ALL OF THE FOLLOWING: AN <br />OPENABLE AREA NOT LESS THAN 5.7 SQ.FT. MIN. CLEAR 24" HEIGHT AND 20" WIDTH AND SILL <br />NOT OVER 44" ABOVE FLOOR <br />4. SHOWER WALLS MUST BE FINISHED TO A HEIGHT OF 72" ABOVE DRAIN W/ MOISTURE <br />RESISTIVE TILE OR APPROVED EQUAL <br />5. MAX. FLOW RATE STANDARDS SET BY THE CALIFORNIA ENERGY COMMISION: WATER CLOSETS <br />1.28 GPF, SHOWERHEADS 2.0 GPM, LAUNDRY FAUCETS 1.5 GPM, SINK FAUCETS 1.5 GPM, AND <br />KITCHEN FAUCETS 1.8 GPM <br />6. EXTERIOR WALLS WITHIN 3 FEET OF PROPERTY LINE (SPRINKLERS) OR 5 FEET OF PROPERTY <br />LINE (WITHOUT SPRINKLERS) REQUIRE 1-HOUR FIRE RATING FOR EXPOSURE TO BOTH SIDES <br />7. PROJECTIONS: - PROHIBITED WITHIN 2 FEET OF PROPERTY LINE - 1-HOUR FIRE RATING ON <br />THE UNDERSIDE WITHIN 3FT OF PROPERTY LINE (SPRINKLERS) - 1-HOUR FIRE RATING ON THE <br />UNDERSIDE WITHIN 5FT OF PROPERTY LINE (WITHOUT SPRINKLERS) <br />S. OPENINGS: - PROHIBITED WITHIN 3FT OF PROPERTY LINE - MAXIMUM 25% OF WALL AREA <br />WITHIN 5 FEET OF PROPERTY LINE (WITHOUT SPRINKLERS) <br />9. PENETRATIONS: - 1-HOUR FIRE -RATED PENETRATIONS OF WALLS WITHIN 3FT OF PROPERTY <br />LINE (SPRINKLERS) - 1-HOUR FIRE -RATED PENETRATIONS OF WALLS WITHIN 5FT OF <br />PROPERTY LINE (WITHOUT SPRINKLERS) <br />iIIQ1]Y <br />20'- 0" <br />OExisting Roof Plan <br />1 /4" = 1 '-0" <br />MIN 2X4 STUDS AT I B' O C., <br />SEE STRUCTURAL DRAWINGS <br />OPTIONAL GLASS FIBER BATT <br />INSULATION PER THERMAL <br />REQUIREMENTS <br />U. <br />718" EXTERIOR CEMENT PLASTER <br />METAL LATH OVER 1 LAYER OF <br />WEATHER RESISTIVE BARRIER <br />WOOD STRUCTURAL SHEAR <br />PANEL WHERE OCCURS, SEE <br />STRUCTURAL DRAWINGS <br />INTERIOR SURFACE TREATMENT J <br />AS REQUIRED PER IBC 2012 <br />TABLE 721 1 (2) ITEM 12 OR 14 <br />1 HOUR RATED PER IBC 2012 TABLE 721.1. Qj ITEM 15-1 3 <br />IL See footnote m for reducton of allowatie F'c <br />1 HOUR EXTERIOR STUCCO WALL <br />3" = V-0" <br />DOOR SCHEDULE <br />QTY. <br />MARK <br />OPENING SIZE <br />TICK <br />DOOR TYPE <br />SCREEN <br />FRAME <br />1 <br />AO <br />3'-0" W X 6'-8" H <br />1 3/8" <br />EXT. SOLID CORE DOOR <br />WOOD WOOD <br />2 <br />O <br />2'-8" W X 6'-8" H <br />1 3/8" <br />INT. HOLLOW CORE DOOR <br />WOOD WOOD <br />1 <br />© <br />T-0" W X 6'-8" H <br />1 3/8" <br />SLIDING CLOSET DOOR <br />WOOD WOOD <br />2 _g <br />O <br />00 <br />Q0 <br />F.F. <br />E:1 <br />E:1 <br />3'-0" <br />0 <br />T-0" <br />O <br />WINDOW SCHEDULE <br />QTY. <br />MARK <br />SIZE <br />TYPE <br />FRAME <br />SCREEN <br />U-Factor <br />SHGC <br />1 <br />O <br />2'-0"W x 2'-0"H <br />SLIDING WINDOW <br />VINY. <br />YES <br />0.3 <br />0.23 <br />1 <br />O <br />2'-8"W x T-0"H <br />SLIDING WINDOW <br />VINY. <br />YES <br />0.3 <br />0.23 <br />1 <br />O <br />4'-0"W x 4'-0"H <br />SLIDING WINDOW <br />VINY. <br />YES <br />0.3 <br />0.23 <br />EGRESS <br />o _ <br />' <br />o <br />co �► <br />ao <br />4'-0" <br />zo <br />EGRESS WINDOW <br />F.F. <br />O O O <br />NOTES: <br />1. BEDROOM EGRESS WINDOWS HAVE A MINIMUM CLEAR OPENING AREA OF 5.7 sf. <br />ABOVE THE GRADE FLOOR AND 5 SQ.FT. ON THE GRADE FLOOR, A MIN. NET HEIGHT OF 24" <br />AND MIN. NET WIDTH OF 20", AND SILL HEIGHT NOT MORE THAN 44" MAX. ABOVE FINISH <br />FLOOR. <br />2. THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS AND SKYLIGHTS (INCL. <br />TUBULAR) MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED. <br />3. SHOWER AND TUB ENCLOSURES SHALL BE TEMPERED (CBC 2406.4) WINDOWS AT <br />SHOWERS AND TUBS SHALL BE TEMPERED. <br />Provide <br />Reinforcement <br />for Grab Bar <br />2 <br />OProposed Floor Plan <br />1 /4" = 1'-0" <br />ATTIC VENT CALCULATION ZONE 1 <br />PROVIDE 1 SQ. IN. OF VENTILATION PER 150 SQ. IN. OF ATTIC SPACE. <br />PROVIDE THAT 50% OF THE REQ. VENTILATION AREA IS PROVIDED BY <br />VENTILATORS IN THE UPPER PORTION OF THE ATTIC, (HIGH VENTING) AT 3'-0" <br />ABOVE EAVE VENT WITH THE BALANCE BEING PROVIDED BY EAVE VENTS, <br />(LOW VENTING) PER I.R.C. R806, (U.B.C. 1505.3). <br />VENTILATION REQUIRED: <br />ATTIC AREA <br />VENTILATION PROVIDED: <br />TOTAL VENTS REQUIRED: 8 <br />510 SQ. FT. / 150 = 3.40 SQ. FT. <br />X 144 = 489.6 SQ. IN. <br />/ 2 = 244.8 SQ. IN. <br />4 14 x 6 Eave Intake Vents 65 SQ. IN. = 260 SQ. IN. <br />4 High / Exhaust O'Hagin Vents 72 SQ. IN. = 288 SQ. IN. <br />TOTAL VENTILATION PROVIDED: <br />548 SQ. IN. <br />01-A-04 <br />18'-0" 3 <br />0 <br />T <br />E <br />�,,� Proposed Roof Plan <br />1 /4" = 1'-0" <br />2 1601-A-04 <br />AGING -IN -PLACE DESIGN AND FALL PREVENTION NOTES <br />R327.1.1 Reinforcement for Grab Bars <br />At least one bathroom on the entry level shall be provided with <br />reinforcement installed in accordance with this section. Where <br />there is no bathroom on the entry level, at least one bathroom on <br />the second or third floor of the dwelling shall comply with this <br />section. <br />R327.1.2 Electrical Receptacle Outlet, Switch and Control <br />Heights <br />Electrical receptacle outlets, switches and controls (including <br />controls for heating, ventilation and air conditioning) intended to <br />be used by occupants shall be located no more than 48 inches <br />(1219.2 mm) measured from the top of the outlet box and not <br />less than 15 inches (381 mm) measured from the bottom of the <br />outlet box above the finish floor. <br />R327.1.3 Interior Doors <br />Effective July 1, 2024, at least one bathroom and one bedroom <br />on the entry level shall provide a doorway with a net clear <br />opening of not less than 32 inches (812.8 mm), measured with <br />the door positioned at an angle of 90 degrees from the closed <br />position; or, in the case of a two- or three-story single family <br />dwelling, on the second or third floor of the dwelling if a bathroom <br />or bedroom is not located on the entry level. <br />R327.1.4 Doorbell Buttons <br />Doorbell buttons or controls, when installed, shall not exceed 48 <br />inches (1219.2 mm) above exterior floor or landing, measured <br />from the top of the doorbell button assembly. Where doorbell <br />buttons integrated with other features are required to be installed <br />above 48 inches (1219.2 mm) measured from the exterior floor <br />or landing, a standard doorbell button or control shall also be <br />provided at a height not exceeding 48 inches (1219.2 mm) above <br />exterior floor or landing, measured from the top of the doorbell <br />button or control. <br />Guidelines require - <br />only 15" on <br />nongrab bar side of <br />toilet; 18" also <br />preferred this side <br />of centerline if <br />planned for two <br />bars (18" shown) <br />possible location for <br />resident installation <br />of fold -up grab bars <br />bar- may be on either <br />side of the toilet, but <br />must be hinged so it <br />folds against the wall <br />behind the toilet and <br />does not interfere with <br />access to the tub and <br />the controls <br />18" <br />Toilet Between Tub and Lavatory <br />Solar Ready <br />Zone To Meet <br />VE <br />Iff B`UILDERS INC <br />con mercial* muttifamity R r-esidentiat <br />ANCE <br />a V 1 %.2 -0 %. 1.- 0 0 0_� . <br />r-.,THIS DESIGN AND DRAWINGS, ARE <br />HT PROTECTED AND ARE <br />dw- <br />TH EXCLUSIVE PROPERTY OF J&C BUILDERS INC, <br />THEY SHALL BE <br />NO USED, MODIFIED DUPLICATED IN <br />ASSIGNED TO A THIRD PARTY WITHOUT <br />THE WRITTEN AUTHORIZATION <br />OF J&C BUILDERS INC. <br />CONSULTANTS <br />OWNER <br />Juan Silva <br />949-232-3265 <br />CONTACT PERSON <br />Jose Zambrano <br />1117 SANTA FE AVE. #100 <br />LONG BEACH CA 90813 <br />MOBILE: 562 522 3549 <br />EMAIL: info@jchomebuilders.net <br />DESIGNER <br />J&C BUILDERS INC <br />1117 SANTA FE AVE. #100 <br />LONG BEACH CA 90813 <br />MOBILE: 562 522 3549 <br />EMAIL: info@jchomebuilders.net <br />T-24 <br />No. Description Date <br />1 Revision 1 Fecha 1 <br />APPROVAL STAMP <br />Convert 360 ft2 garage <br />+ 150 ft2 Add for a total <br />of 510 ft2 A D U <br />909 S Pacific Ave, <br />Santa Ana, CA 92703 <br />EXISTING & PROPOSED <br />LOOR/ROOF PLANS <br />Pro ec number 0001 <br />Date 02-13-2025 <br />Drawn by AC Builders <br />Checked by <br />01-A- 0 2 <br />