CITY OF SANTA ANA <br />EXHAUST <br />FAN <br />EXHAUST <br />FAN <br />D <br />O <br />-n <br />0 <br />LED <br />Laundry <br />EXHAUST <br />FANS <br />n <br />n <br />Pc <br />LED <br />Bedroom <br />SD ' <br />M <br />LED LED <br />OUtility Plan (For reference only) <br />1 /4" = 1 '-0" <br />UTILITY LEGEND <br />Y D <br />SWITCH ON DIMMER <br />vs <br />SWITCH ON VACANCY SENSOR <br />LED <br />RECESSED LED LIGHT <br />w <br />WET LOCATION APPROVED <br />LED <br />RECESSED LED <br />WALL MOUNTED LED LIGHT FIXTURE <br />I NT/EXT <br />o <br />DUPLEX OUTLET (AFCI) <br />o <br />GFIC DUPLEX OUTLET (GFCI & AFCI <br />DUPLEX @ KIT & LAU) <br />°- <br />EXTERIOR WATER PROOF GFIC <br />DUPLEX OUTLET <br />MINI SPLIT <br />NEW ELECTRICAL TANKLESS <br />WATER HEATER (16,000 BTU) <br />EXHAUST INTAKE FAN. 50 CFM MIN. <br />❑ <br />WITH HUMIDSTAT CONTROLS AT <br />RESTROOMS, LAU AND UTILITY. 100 <br />CFM MIN AT KITCHEN <br />ELECTRICAL PANEL 200 A. <br />WATER FIXTURE <br />Water Closets <br />1.28 gallons/flush <br />Urinals <br />0.5 gallons/flush <br />Single Showerheads <br />2 gpm @ 80 psi <br />Multiple Showerheads / <br />combinated showerheads <br />2 gpm @ 80 psi <br />for all <br />Lavatory faucets, residential <br />1.2 gpm @ 60 psi <br />Lavatory faucets, noresidential <br />0.5 gpm @ 60 psi <br />Metering faucets <br />0.25 gallons per cycle <br />Kitchen faucets <br />1.8 gallons/flush at 60 psi <br />UTILITY NOTES <br />1 ALL BRANCH CIRCUTS SUPPLYING RECEPTACLES SHALL BE PROTECTED BY <br />LISTED ARC -FAULT CIRCUIT INTERRUPTER (AFCI) <br />2. ALL 120-VOLT, SINGLE PAHSE 15 AND 20 AMP BRANCH CIRCUIT SUPPLYING <br />OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, <br />PARLORS, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, <br />LAUNDRY ROOMS OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY OF <br />THE MEANS DESCRIBED IN 210.12 (A)(1). AT KITCHEN COUNTER SPACE, RECEPTACLES <br />SHALL BE INDICATED AS COMBINATION AFCDI/GFCI. <br />3. TAMPER RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED IN SECTION 210.52 <br />ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT <br />RECEPTACLES <br />4. NEW BOXES USED AT LUMINAIRES OR LAMPHOLDER OUTLETS IN A CEILING SHALL <br />BE REQUIRED TO SUPPORT A LUMINAIRIE WEIGHING A MINIMUM OF 50 LB. BOXES USED AT <br />LUMINARIE OUTLETS IN WALL SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE <br />MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF LUMINAIRE PERMITTED, <br />IF OTHER THAN 50 LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF <br />CEILING FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURE AS SUITABLE FOR <br />THIS PURPOSE. (314.27 CEC) <br />5. ALL LEAD LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY NATIONAL <br />ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS <br />THEY ARE CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE <br />COMBINED USE OF NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN <br />ENSURE FLICKER FREE OPERATION WHEN THE LUMINAIRE IS DIMMED. (2019 RESIDENTIAL <br />COMPLIANCE MANUAL 6.3.1(G) <br />6. IN BATHROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THIS SPACES MUST BE <br />CONTROLLED BY AN OCCUPANT SENSOR OR A VACANCY SENSOR PROVIDING <br />AUTOMATIC -OFF FUNCTIONALITY. IF A OCCUPANT SENSOR IS INSTALLED, IT MUST BE <br />INITIALLY CONFIGURED TO MANUAL -ON OPERATION USING THE MANUAL CONTROL <br />REQUIRED UNDER SECTION 150.0(k)2C. <br />7. SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING <br />WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. (907.2.11.5, R314.4) <br />8. IN EXISTING SFD, SMOKE DETECTORS MAY BE BATTERY OPERATED. (907.2.11.9, <br />R314.4) <br />ADDITIONAL NOTES <br />1. PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN <br />COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE <br />BALANCED. CEC 210-52(B) (2) <br />2. PROVIDE A MINIMUM OF (1) 20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT <br />SHALL HAVE NO OTCOHER OUTLETS. CEC 210-23(A). <br />3. A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT <br />SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM <br />CEC 210-23 <br />4. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE <br />LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY A VACANCY SENSOR. <br />5. OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING, OR <br />TO OTHER BUILDING ON THE SAME LOT, MUST MEET THE REQUIREMENT IN ITEM <br />150.0(K)3AI (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(K)3AI1 <br />(PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(K)3AIII (PHOTO CONTROL AND <br />AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS <br />6. ALL LIMINAIRES SHALL BE HIGH EFFICACY - PER SECTION 150.0(K)1A. <br />7. CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-23(A). <br />Utilities Site Plan <br />'�tJ 1 /8" = V-0" <br />PROPERTY LINE 65' <br />PROPERTY LINE 65' <br />S PACIFIC AVE <br />I <br />I <br />I EX. LANDSCAPE <br />I <br />I <br />I <br />I <br />Ex. Condenser <br />T <br />W <br />z <br />W <br />n- <br />o <br />Of <br />a - <br />Ex. W H <br />r � <br />co <br />v_o <br />JILDERS INC <br />me- rcial* multifamily R residetnt D! <br />gency I <br />A CE <br />I V I %�% -0 %. N.- 0 0 0_� . <br />THI DESIGN AND DRAWINGS, ARE <br />HT PROTECTED AND ARE <br />dw- <br />TH EXCLUSIVE PROPERTY OF J&C BUILDERS INC, <br />THEY SHALL BE <br />NO USED, MODIFIED DUPLICATED IN <br />ASSIGNED TO A THIRD PARTY WITHOUT <br />THE WRITTEN AUTHORIZATION <br />OF J&C BUILDERS INC. <br />CONSULTANTS <br />OWNER <br />Juan Silva <br />949-232-3265 <br />CONTACT PERSON <br />Jose Zambrano <br />1117 SANTA FE AVE. #100 <br />LONG BEACH CA 90813 <br />MOBILE: 562 522 3549 <br />EMAIL: info@jchomebuilders.net <br />DESIGNER <br />J&C BUILDERS INC <br />1117 SANTA FE AVE. #100 <br />LONG BEACH CA 90813 <br />MOBILE: 562 522 3549 <br />EMAIL: info@jchomebuilders.net <br />T-24 <br />No. Description Date <br />1 Revision 1 Fecha 1 <br />APPROVAL STAMP <br />Convert 360 ft2 garage <br />+ 150 ft2 Add for a total <br />of 510 ft2 A D U <br />909 S Pacific Ave, <br />Santa Ana, CA 92703 <br />PROPOSED UTILITY PLANS <br />& UTILITY NOTES <br />Pr ' tuber 0001 <br />Date 02-13-2025 <br />Drawn by AC Builders <br />Checked by <br />01-A- 0 3 <br />