D
<br />II
<br />1.32900
<br />0.47400
<br />1.06300
<br />0.53700
<br />DATE:11/14/2024
<br />JOB NO: MLB24-1210
<br />DESIGNED BY: HK
<br />CHECKED BY: GB
<br />DE
<br />S
<br />C
<br />R
<br />I
<br />P
<br />T
<br />I
<br />O
<br />N
<br />DA
<br />T
<br />E
<br />RE
<br />V
<br />BY
<br />1 3 4 5
<br />-
<br />2
<br />-
<br />-
<br />MLB CONSULTING AND
<br />ENGINEERING, INC
<br />7918 FOOTHILL BLVD
<br />SUNLAND, CA 91040
<br />(818) 521-6342
<br />INFO@MLBENGINEERING.ORG
<br />4703 W McFadden
<br />Ave Santa Ana, CA
<br />92704
<br />DATE:11/14/2024
<br />JOB NO: MLB24-1210
<br />DESIGNED BY: HK
<br />CHECKED BY: GB
<br />DE
<br />S
<br />C
<br />R
<br />I
<br />P
<br />T
<br />I
<br />O
<br />N
<br />DA
<br />T
<br />E
<br />RE
<br />V
<br />BY
<br />1 3 4 5
<br />-
<br />2
<br />-
<br />-
<br />MLB CONSULTING AND
<br />ENGINEERING, INC
<br />7918 FOOTHILL BLVD
<br />SUNLAND, CA 91040
<br />(818) 521-6342
<br />INFO@MLBENGINEERING.ORG
<br />4703 W McFadden
<br />Ave Santa Ana, CA
<br />92704
<br />STRUCTURAL - GENERAL NOTES
<br />GENERAL REQUIREMENTS
<br />GOVERNING CODE: THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE “CALIFORNIA
<br />BUILDING CODE (CBC)”, 2022 EDITION, HEREAFTER REFERRED TO AS THE CBC, AS ADOPTED AND MODIFIED BY
<br />THE COUNTY OF LOS ANGELES, UNDERSTOOD TO BE THE AUTHORITY HAVING JURISDICTION (AHJ).
<br />REFERENCE STANDARDS: REFER TO CHAPTER 35 OF 2022 CBC. WHERE OTHER STANDINGS ARE NOTED IN THE
<br />DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A SPECIFIC DATE IS INDICATED.
<br />REFERENCE TO A SPECIFIC SECTION IN CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE
<br />WITH THE ENTIRE STANDARD.
<br />DEFINITIONS: THE FOLLOWING DEFINITIONS COVER THE MEANINGS OF CERTAIN TERMS USED IN THESE
<br />NOTES:
<br />·“ARCHITECT/ENGINEER” - THE ARCHITECT OF RECORD AND THE STRUCTURAL/CIVIL ENGINEER OF
<br />RECORD.
<br />·“STRUCTURAL/CIVIL ENGINEER OF RECORD” (SER) OR (EOR) - THE STRUCTURAL/CIVIL ENGINEER WHO IS
<br />LICENSED TO STAMP & SIGN THE STRUCTURAL DOCUMENTS FOR THE PROJECT. THE SER IS
<br />RESPONSIBLE FOR THE DESIGN OF THE PRIMARY STRUCTURAL SYSTEM.
<br />·“SUBMIT FOR REVIEW” - SUBMIT TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FABRICATION OR
<br />CONSTRUCTION.
<br />·“PER PLAN” - INDICATED REFERENCES TO THE STRUCTURAL PLANS, ELEVATIONS AND STRUCTURAL
<br />GENERAL NOTES.
<br />·“ENGINEER OF RECORD”(EOR) - A PROFESSIONAL ENGINEER (PE OR SE), LICENSED IN THE STATE WHERE
<br />THE PROJECT IS LOCATED, (TYPICALLY THE SER). DOCUMENTS STAMPED AND SIGNED BY THE EOR
<br />SHALL BE COMPLETED BY OR UNDER THE DIRECT SUPERVISION OF THE EOR.
<br />·“BIDDER-DESIGNED” - COMPONENTS OF THE STRUCTURE THAT REQUIRE THE GENERA; CONTRACTOR,
<br />SUBCONTRACTOR, OR SUPPLIER WHO IS RESPONSIBLE FOR THE DESIGN, FABRICATION AND
<br />INSTALLATION OF SPECIALTY-ENGINEERED ELEMENTS IDENTIFIED IN THE CONTRACT DOCUMENTS TO
<br />RETAIN THE SERVICES OF AN SSE. SUBMITTALS OF “BIDDER-DESIGNED” ELEMENTS SHALL BE STAMPED
<br />AND SIGNED BY THE SSE.
<br />SPECIFICATIONS: REFER TO THE PROJECT SPECIFICATIONS ISSUED AS PART OF THE CONTRACT DOCUMENTS
<br />FOR INFORMATION SUPPLEMENTAL TO THESE DRAWINGS
<br />OTHER DRAWINGS: REFER TO THE ARCHITECTURAL, MECHANICAL. ELECTRICAL, CIVIL, AND PLUMBING
<br />DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING BUT NOT LIMITED TO: DIMENSIONS, ELEVATIONS,
<br />SLOPES, DOOR AND WINDOW OPENINGS, NON-BEARING WALLS, STAIRS, FINISHES, DRAINS, WATERPROOFING,
<br />RAILINGS, ELEVATORS, CURBS, DEPRESSIONS, MECHANICAL UNIT LOCATIONS, AND OTHER NON-STRUCTURAL
<br />ITEMS.
<br />STRUCTURAL DETAILS: THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND
<br />EXTENT OF THE PROJECT AND ARE NOT INTENDED TO SHOW ALL DETAILS OF THE WORK. USE ENTIRE DETAIL
<br />SHEETS AND SPECIFIC DETAILS REFERENCED IN THE PLANS AS “TYPICAL” WHEREVER THEY APPLY.
<br />SIMILARLY, USE DETAILS ON ENTIRE SHEETS WITH “TYPICAL' IN THE SAME NAME WHEREVER THEY APPLY.
<br />STRUCTURAL RESPONSIBILITIES: THE STRUCTURAL/CIVIL ENGINEER IS RESPONSIBLE FOR THEIR STRENGTH
<br />AND STABILITY OF THE PRIMARY STRUCTURE IN ITS COMPLETED FORM.
<br />COORDINATION: THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND ACCURACY OF THE
<br />WORK; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING
<br />FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY; AND FOR PERFORMING WORK IN A SAFE AND
<br />SECURE MANNER.
<br />PRE-CONSTRUCTION MEETINGS: THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING PRE-CONSTRUCTION
<br />MEETINGS PRIOR TO COMMENCING WORK. PRE-CON MEETINGS, SCHEDULED APPROXIMATELY TWO WEEKS
<br />PRIOR FROM THE START OF THE RELEVANT WORK, ARE REQUIRED FOR THE FOLLOWING PHASES OF
<br />CONSTRUCTION: POST-TENSIONED SLABS, STRUCTURAL STEEL AND CONCRETE. ATTENDEES FOR
<br />PRE-CONSTRUCTION MEETING ARE TO INCLUDE CONTRACTOR, RELEVANT SUBCONTRACTORS,
<br />FABRICATORS, INSPECTORS, ARCHITECT/ENGINEER, AND REPRESENTATIVE OF THE AUTHORITY HAVING
<br />JURISDICTION WHERE REQUIRED. MEETING AGENDAS ARE TO INCLUDE REVIEW OF THE WORK SCOPE,
<br />PROJECT SCHEDULE RELEVANT TO THE WORK, CONTACT INFORMATION OF RESPONSIBLE PARTIES,
<br />INSPECTION POINTS, REVIEW OF MATERIALS AD ANY SPECIAL CASES OR ISSUES, PROCEDURES FOR
<br />CLARIFICATIONS IF REQUIRED, TESTING AND ACCEPTANCE, ETC.
<br />MEANS, METHODS AND SAFETY REQUIREMENTS: THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND
<br />METHODS OF CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND DOSH
<br />(DEPARTMENT OF OCCUPATIONAL SAFETY AND HEALTH). CONTRACTOR IS RESPONSIBLE TO ADHERE TO
<br />OSHA REGULATIONS. BOLTING AND FIELD WELDING AT ALL MEMBER CONNECTIONS IS TO BE COMPLETED
<br />PRIOR TO THE RELEASE OF THE MEMBER FROM THE HOISTING MECHANISM UNLESS REVIEWED AND
<br />APPROVED BY THE GENERAL CONTRACTOR'S TEMPORARY BRACING AND SHORING DESIGN ENGINEER.
<br />BRACING/SHORING DESIGN ENGINEER: THE CONTRACTOR SHALL AT HIS DISCRETION EMPLOY AN SSE, A
<br />REGISTERED PROFESSIONAL ENGINEER FOR THE DESIGN OF ANY TEMPORARY BRACING AND SHORING.
<br />TEMPORARY SHORING, BRACING: THE CONTRACTOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF
<br />THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE SHORING, BRACING AND OTHER ELEMENTS
<br />REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE IS COMPLETE. IT IS THE CONTRACTOR'S
<br />RESPONSIBILITY TO BE FAMILIAR WITH THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE
<br />REQUIREMENTS FOR EXECUTING IT PROPERLY.
<br />CONSTRUCTION LOADS: LOADS ON THE STRUCTURE DURING CONSTRUCTION SHALL NOT EXCEED THE DESIGN
<br />LOADS AS NOTED IN THE DESIGN CRITERIA & LOADS BELOW OR THE CAPACITY OF PARTIALLY COMPLETED
<br />CONSTRUCTION AS DETERMINED BY THE CONTRACTOR'S SSE FOR BRACING/SHORING.
<br />CHANGES IN LOADING: THE CONTRACTOR HAS THE RESPONSIBILITY TO NOTIFY THE SER OF ANY
<br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, OR PLUMBING LOAD IMPOSED ONTO THE STRUCTURE THAT
<br />DIFFERS FROM, OR THAT IS NOT DOCUMENTED ON THE ORIGINAL CONTRACT DOCUMENTS
<br />(ARCHITECTURAL/STRUCTURAL/MECHANICAL/ELECTRICAL OR PLUMBING DRAWINGS). PROVIDE
<br />DOCUMENTATION OF LOCATION, LOAD, SIZE AND ANCHORAGE OF ALL UNDOCUMENTED LEADS IN EXCESS OF
<br />400 POUNDS. PROVIDE MARKED-UP STRUCTURAL PLAN INDICATING LOCATIONS OF ANY NEW EQUIPMENT OR
<br />LOADS. SUBMIT PLANS TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO INSTALLATION.
<br />NOTE PRIORITIES: PLAN AND DETAIL NOTES AND SPECIFIC LOADING DATA PROVIDED ON INDIVIDUAL PLANS
<br />AND DETAIL DRAWINGS SUPPLEMENTS INFORMATION IN THE STRUCTURAL GENERAL NOTES.
<br />DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN THE GENERAL NOTES, SPECIFICATIONS,
<br />PLANS/DETAILS OR REFERENCE STANDARDS, THE ARCHITECT/ENGINEER SHALL DETERMINE WHICH SHALL
<br />GOVERN. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE
<br />PROCEEDING WITH THE WORK. SHOULD ANY DISCREPANCY BE FOUND IN THE CONTRACT DOCUMENTS, THE
<br />CONTRACTOR WILL BE DEEMED TO HAVE INCLUDED IN THE PRICE THE MOST EXPENSIVE WAY OF
<br />COMPLETING WORK, UNLESS PRIOR TO THE SUBMISSION OF THE PRICE, THE CONTRACTOR ASKS FOR A
<br />DECISION FROM THE ARCHITECT AS TO WHICH SHALL GOVERN. ACCORDINGLY, ANY CONFLICT BETWEEN THE
<br />CONTRACT DOCUMENTS SHALL NOT BE A BASIS FOR ADJUSTMENT IN THE CONTRACT PRICE.
<br />SITE VERIFICATION: THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE.
<br />CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION
<br />OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK.
<br />ADJACENT UTILITIES: THE CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL ADJACENT UNDERGROUND
<br />UTILITIES PRIOR TO EARTHWORK FOUNDATIONS, SHORING, AND EXCAVATION. ANY UTILITY INFORMATION
<br />SHOWN ON THE DRAWINGS AND DETAILS IS APPROXIMATE AND NOT NECESSARILY COMPLETE.
<br />ALTERNATES: ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE AND FORM FOR SPECIFIED ITEMS MAY
<br />BE SUBMITTED WITH ADEQUATE TECHNICAL DOCUMENTATION (PROPER TEST REPORT, ETC.) TO THE
<br />ARCHITECT/ENGINEER FOR REVIEW. ALTERNATE MATERIALS THAT ARE SUBMITTED WITHOUT ADEQUATE
<br />TECHNICAL DOCUMENTATION OR THAT SIGNIFICANTLY DEVIATE FROM THE DESIGN INTENTS OF MATERIALS
<br />SPECIFIED MAY BE RETURNED WITHOUT REVIEW. ALTERNATES THAT REQUIRE SUBSTANTIAL EFFORT TO
<br />REVIEW WILL NOT BE REVIEWED UNLESS AUTHORIZED BY THE OWNER.
<br />MAIN WIND FORCE RESISTING SYSTEM
<br />Ultimate Design Wind Speed, VULT (MPH)
<br />Exposure Category
<br />Internal Pressure Coefficient
<br />Topographic Factor
<br />Wind Analysis Procedure Used:
<br />COMPONENT & CLADDING PRESSURES FOR DESIGN
<br />Wall Cladding, Typical Zone
<br />Wall Cladding, Edge Zone within 20 ft. of corners
<br />Roof Cladding, Middle Zone
<br />Roof Cladding, Edge Zone within 20 ft. of edge
<br />Roof Cladding, Corner Zone within 20 ft. of corners
<br />Cpi =
<br />Kzt =
<br />DESIGN CRITERIA
<br />Risk Category of Building per 2022 CBC Table 1604.5 =
<br />Site Classification per CBC 1613.3.2 & ASCE 7-16, CH. 20
<br />Site Class =
<br />Seismic Design Category:
<br />Seismic Importance Factor per ASCE 7-16 Table 1.5-2
<br />Spectral Response Acceleration (Short Period)
<br />Spectral Response Acceleration (1-Second Period)
<br />Spectral Design Response Coefficient (Short Period)
<br />Spectral Design Response Coefficient (1-Second Period)
<br />SDC =
<br />IE =
<br />SS =
<br />S1 =
<br />SDS =
<br />SD1 =
<br />SEISMIC FORCE RESISTING SYSTEMS:
<br />Light-frame (wood) sheathed with wood structural panels
<br />rated for shear resistance (Wood Shearwalls)
<br />Response Modification Factor
<br />System Overstrength Factor
<br />Deflection Amplification Factor
<br />Seismic Response Coefficient
<br />Redundancy Factor
<br />R =
<br />Ω =
<br />Cd =
<br />Cs =
<br />ρ =
<br />Special Reinforced Concrete Shearwalls
<br />R =
<br />Ω =
<br />Cd =
<br />Cs =
<br />ρ =
<br />Response Modification Factor
<br />System Overstrength Factor
<br />Deflection Amplification Factor
<br />Seismic Response Coefficient
<br />Redundancy Factor
<br />6.5
<br />2.5
<br />4
<br />1.3
<br />5
<br />2.5
<br />5
<br />1.3
<br />SEIMIC DESIGN:
<br />DL (PSF)
<br />DESIGN DEAD & LIVE LOADS
<br />INSPECTIONS, QUALITY ASSURANCE, VERIFICATIONS AND TEST REQ's
<br />INSPECTIONS: FOUNDATIONS, FOOTINGS, UNDER SLAB SYSTEMS AND FRAMING ARE SUBJECT TO INSPECTION
<br />BY THE BUILDING OFFICIAL IN ACCORDANCE WITH CBC 110.3. CONTRACTOR SHALL COORDINATE ALL
<br />REQUIRED INSPECTIONS WITH THE BUILDING OFFICIAL.
<br />SPECIAL INSPECTIONS, VERIFICATIONS AND TESTS: SPECIAL INSPECTION, VERIFICATIONS AND TESTING SHALL
<br />BE DONE IN ACCORDANCE WITH CBC CHAPTER 17 AND THE STATEMENT OF SPECIAL INSPECTIONS HEREIN
<br />PER CBC SECTIONS 1704 AND 1705, INCLUDING 1705.11 FOR SEISMIC RESISTANCE FOR PROJECTS IN
<br />SEISMIC DESIGN CATEGORIES C , D, E AND F AS APPLICABLE.
<br />SPECIAL INSPECTION AGENCY AND SPECIAL INSPECTORS: OWNER SHALL RETAIN AN “APPROVED AGENCY” PER
<br />CBC 1703 TO PROVIDE SPECIAL INSPECTIONS FOR THE PROJECT, SPECIAL INSPECTORS SHALL BE
<br />QUALIFIED PERSONS PER CBC 1704.2.1.
<br />STATEMENT OF SPECIAL INSPECTIONS: SPECIAL INSPECTIONS AND TESTING PER CBC SECTIONS 1704 AND 1705
<br />ARE REQUIRED FOR THE FOLLOWING:
<br />FABRICATION SHOP INSPECTION: WHERE OFF-SITE FABRICATION OF GRAVITY LOAD BEARING MEMBERS
<br />& ASSEMBLIES IS PERFORMED, SPECIAL INSPECTOR SHALL VERIFY THAT THE FABRICATOR COMPLIES
<br />WITH CBC 1704.2.
<br />SOILS & FOUNDATION CONSTRUCTION PER CBC SECTION 1705.6
<br />·PERIODIC INSPECTION OF SOILS EARTHWORK PER TABLE 1705.6 IS REQUIRED FOR:
<br />o FOOTING SOIL BEARING SURFACED PRIOR TO PLACING ANY REINFORCING STEEL
<br />o EXCAVATION DEPTH AND BEARING LAYER PRIOR TO PLACING ANY REINFORCING
<br />STEEL.
<br />o COMPACTED FILL MATERIAL CLASSIFICATION
<br />o SUBGRADE PREPARATION PRIOR TO FILLING
<br />·CONTINUOUS INSPECTION PER TABLE 1705.6 IS REQUIRED FOR:
<br />o FILLING OPERATIONS TO SATISFY REQUIREMENTS OF CBC TABLE 1705.6 AND THE
<br />GEOTECHNICAL REPORT LISTED UNDER SOILS AND FOUNDATIONS SECTION
<br />o COMPACTED FILL DENSITY TESTING OF EACH LIFT THICKNESS AND MATERIAL
<br />CLASSIFICATION
<br />CONCRETE CONSTRUCTION PER CBC SECTION 1705.3 AND TABLE 1705.3 INCLUDING:
<br />·PERIODIC INSPECTION REQUIRED FOR:
<br />o SIZE AND PLACEMENT OF ALL REINFORCING STEEL AND PT TENDONS PRIOR TO THE
<br />POUR
<br />o PLACEMENT CLEARANCES AROUND REINFORCING STEEL AND PT TENDONS AT
<br />EMBEDDED CONDUIT
<br />o PLACING AND SIZE OF CAST-IN-PLACE BOLTS AND EMBEDDED FABRICATIONS PRIOR
<br />TO THE POUR
<br />o SHAPE, LOCATION AND DIMENSIONS OD MEMBERS FORMED
<br />o USE OF THE REQUIRED DESIGN CONCRETE MIX
<br />o MAINTENANCE OF SPECIFIC CURING TEMPERATURE AND TECHNIQUES
<br />o VERIFICATION OF IN-SITU CONCRETE STRENGTH PRIOR TO REMOVAL OF SHORES AND
<br /> FORMS FROM BEAMS AND STRUCTURAL SLABS
<br />o VERIFICATION OF IN-SITU CONCRETE STRENGTH TO STRESSING OF PT TENDONS
<br />·CONTINUOUS INSPECTION REQUIRED DURING THE
<br />o PLACING OF REINFORCED CONCRETE FOR PROPER APPLICATION TECHNIQUES
<br />o PLACING CONCRETE AROUND CAST-IN-PLACE BOLTS AND EMBEDS
<br />o SAMPLING OF FRESH CONCRETE
<br />o DETERMINATIONS OF SLUMP, AIR CONTENT AND TEMPERATURE
<br />o GROUTING OPERATION OF POST-INSTALLED BOLTS AND EMBEDS
<br />o PT TENDON STRESSING
<br />SHOTCRETE CONSTRUCTION: PER CBC 1910 INCLUDING:
<br />·CONTINUOUS INSPECTION REQUIRED DURING THE:
<br />o SHOTCRETE PLACEMENT FOR THE PRECONSTRUCTION TEST PANEL (IF REQUIRED BY
<br />THE AHJ OR THE EOR)
<br />o TAKING OF CORE SPECIMENS FOR CONSTRUCTION SPECIMENS
<br />o PLACING OF ALL PRODUCTION SHOTCRETE
<br />STRUCTURAL MASONRY PER CBC SECTION 1705.4 AND 1705.12
<br />LEVEL A - MASONRY CONSTRUCTION PER TMS 402-11/ACI 530-11/ASCE 6-11 SECTION 1.19.1:
<br />·PERIODIC INSPECTION REQUIRED FOR:
<br />o SIZE, GRADE, PLACEMENT AND TYPE OF REINFORCING STEEL AND CONNECTORS
<br />o PROPORTIONS OF SITE-PREPARED MORTAR
<br />o PROTECTION OF MASONRY DURING COLD WEATHER (TEMP. BELOW 40 DEGREES F)
<br />o PROTECTION OF MASONRY DURING HOT WEATHER (TEMP ABOVE 90 DEGREES F)
<br />o COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF THE CONSTRUCTION
<br />DOCUMENTS AND THE APPROVED SUBMITTALS
<br />STRUCTURAL STEEL PER CBC 1704.2.5.1
<br />A QUALIFIED SPECIAL INSPECTOR OF AN “APPROVED AGENCY” PROVIDING QUALITY
<br />ASSURANCE (QA) SPECIAL INSPECTIONS FOR THE PROJECT SHALL REVIEW AND CONFIRM THE
<br />FABRICATOR AND ERECTOR'S QUALITY CONTROL (QC) PROCEDURES FOR
<br />COMPLETENESS AND ADEQUACY RELATIVE TO AISC 360-10 CHAPTER N, THE AISC 303 CODE OF
<br />STANDARD PRACTICE, AWS D1.1-2010 STRUCTURAL WELDING CODE AND CURRENT CBC CODE
<br />REQUIREMENTS FOR THE FABRICATOR'S SCOPE WORK
<br />o QA AGENCY PROVIDING SPECIAL INSPECTION AND NONDESTRUCTIVE TESTING NDT PER
<br />AISC 360-10 SECTION N4
<br />o VERIFY FABRICATOR AND ERECTOR QUALITY CONTROL PROGRAM PER AISC 360-10
<br />SECTION N2
<br />o VISUAL WELDING INSPECTION OF WELDS BY BOTH QC AND QA PERSONNEL SHALL BE PER
<br /> TABLED LISTED IN AISC 360 SECTION N5
<br />o INSPECTION TASKS FOR WELDING
<br />§PRIOR TO WELDING PER AISC 360-10 TABLE N5.4-1
<br />§DURING WELDING PER AISC 360-10 TABLE N5.4-2
<br />§AFTER WELDING PER AISC 360-10 TABLE N5.4-3
<br />o NONDESTRUCTIVE TESTING (NDT) OF WELDS:
<br />§NON-DESTRUCTIVE WELDING (NDT) OF WELDED JOINTS PER AISC 360-10 N.5
<br />§RISK CATEGORY FOR DETERMINATION OF EXTENT OF NDT PER AISC 360 N5.5B IS NOTED IN
<br />THE DESIGN CRITERIA AND LOADS SECTION OF THESE GENERAL REQUIREMENTS
<br />§NDT PERFORMED SHALL BE DOCUMENTED AND REPORTS SHALL} IDENTIFY THE TESTED
<br />WELD PIECE MARK AND LOCATION IN THE PIECE
<br />§FOR FIELD WORK, THE NDT REPORT SHALL IDENTIFY THE TESTED WELD BY LOCATION IN
<br />THE STRUCTURE, PIECE MARK AND LOCATION IN THE PIECE
<br />§FOR FIELD WORK, THE NDT REPORT SHALL IDENTIFY THE TESTED WELD BY LOCATION IN
<br />THE STRUCTURE, PIECE MARK AND LOCATION IN THE PIECE
<br />o INSPECTION TASKS FOR BOLTING PER AISC 360-10 SECTION N5.6
<br />§PRIOR TO BOLTING PER AISC 360-10 TABLE N5.6-1 (NOT REQUIRED FOR SNUG-TIGHT
<br />JOINTS)
<br />§DURING BOLTING PER AISC 360-10 TABLE N5.6-2 (NOT REQUIRED FOR SNUG-TIGHT JOINTS)
<br />§AFTER BOLTING PER AISC 360-10 TABLE N5.6-3
<br />o ADDITIONAL INSPECTION TASKS PER AISC 360-10 SECTION N5.7
<br />o INSPECTION FOR COMPOSITE CONSTRUCTION SHALL BE DONE PER AISC 360-10 SECTION N6
<br />LL (PSF)AREAOCCUPANCY OR USE
<br />Residential
<br />Uninhabitable attics without storage
<br />Uninhabitable attics with storage
<br />Private Rooms and Corridors serving them
<br />Balcony and Decks
<br />Roofs
<br />Ordinary flat, pitched, and curved roofs
<br />Stair and exitway ways
<br />One- and two-family dwellings only
<br />Misc.
<br />Handrails and guardrails
<br />25 60
<br />15 20
<br />15
<br />15
<br />20 40
<br />10
<br />20
<br />20 40
<br />50 plf /
<br />200 lbs30
<br />Exterior walls
<br />Interior walls
<br />WOOD-FRAMED WALLS 19
<br />14
<br />(1)Top rail shall be designed to resist 50 PLF line load or 200 ib point load applied in any direction at any point.
<br />Intermediate rails (all those except the handrail), balusters and panel fillers shall be designed to withstand a
<br />horizontally applied normal load of 50 LB on an area not to exceed 1 ft square. These three loads are to be
<br />considered separately with worst case used for design.
<br />(2) Place 300lb concentrated load over 2”x2” area at any point to produce maximum stress. Area load and concentrated
<br />load are to be considered separately with worst case used for design
<br />(3) Need not apply concurrently with other handrail and guardrail loads; applied over not more than 1 square foot
<br />(4) Apply concentrated wheel load over 4.5”x4.5” square area
<br />WIND DESIGN:
<br />OCCUPANCY
<br />WOOD CONSTRUCTION PER CBC SECTION 1705.5 & 1705.11.2:
<br />·PERIODIC INSPECTION REQUIRED FOR VERIFICATION OF:
<br />O SHEAR WALLS: ANCHOR BOLTS, HOLD DOWNS (HD) AND CONTINUOUS ROD TIE-DOWN SYSTEMS (TDS)
<br />INCLUDING SQUASH BLOCKS, LPT SHEAR CONNECTORS, STRAP CONNECTORS, BOUNDARY EDGE NAILING,
<br />PLATE NAILING, AND PANEL EDGE SHEAR NAILING FOR SIZE & SPACING WHERE FASTENER SPACING OF THE
<br />SHEATHING IS 4 INCHES OR LESS.
<br />O DIAPHRAGMS: BLOCKING, STRAP CONNECTIONS, BOUNDARY EDGE AND PANEL SHEAR NAILING SIZE &
<br /> SPACING WHERE FASTENER SPACING OF THE SHEATHING IS 4 INCHES OR LESS
<br />O MOISTURE CONTENT OF WOOD STUDS, PLATES, BEAMS AND JOISTS
<br />O PROPER BOTTOM PLATES SIZES (2X AND 3X) AND PLATE WASHERS
<br />O ROOF TRUSS 'HURRICANE' CLIPS.
<br />POST-INSTALLED ANCHORS TO CONCRETE AND MASONRY: SHALL COMPLY WITH CBC SECTION 1703. INSPECTIONS
<br />SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH IN THE APPROVED ICC EVALUATION REPORT AND AS
<br />INDICATED BY THE DESIGN REQUIREMENTS SPECIFIED ON THE DRAWINGS. REFER TO THE POST INSTALLED ANCHORS
<br />SECTION OF THESE NOTES FOR ANCHORS THAT ARE THE BASIS OF THE DESIGN. SPECIAL INSPECTOR SHALL VERIFY
<br />ANCHORS ARE AS SPECIFIED IN THE POST INSTALLED ANCHORS SECTION OF THESE NOTES OR AS OTHERWISE SPECIFIED
<br />ON THE DRAWINGS. SUBSTITUTIONS REQUIRE APPROVAL BY THE SER AND REQUIRE SUBSTANTIATING CALCULATIONS
<br />AND CURRENT 2012 IBC RECOGNIZED ICC EVALUATION SERVICES (ES) REPORT. SPECIAL INSPECTOR SHALL DOCUMENT IN
<br />THEIR SPECIAL INSPECTION REPORT COMPLIANCE WITH EACH OF THE ELEMENTS REQUIRED WITHIN THE APPLICABLE ICC
<br />EVALUATION SERVICES (ES) REPORT
<br />INSPECTION SUBMITTALS: SPECIAL INSPECTION REPORTS SHALL BE PROVIDED ON A WEEKLY BASIS. FINAL SPECIAL
<br />INSPECTION REPORTS WILL BE REQUIRED BY EACH SPECIAL INSPECTION FIRM PER CBC 1704.2.4. SUBMIT COPIES OF ALL
<br />INSPECTION REPORTS TO THE ARCHITECT/ENGINEER AND THE AUTHORITY HAVING JURISDICTION FOR REVIEW
<br />STRUCTURAL OBSERVATION: STRUCTURAL OBSERVATION SHALL BE PROVIDED FOR STRUCTURES CLASSIFIED AS SEISMIC
<br />DESIGN CATEGORY D, E AND F IN ACCORDANCE WITH CBC SECTION 1704.5 AND SECTION 107.3.4. STRUCTURAL
<br />OBSERVATION SITE VISITS WILL BE AS FOLLOWS: PRIOR TO FIRST FOUNDATION POUR, DURING SHEAR WALL
<br />CONSTRUCTION, PRIOR TO EACH UNIQUE ELEVATED SLAB POUR , PRIOR TO THE FIRST MILD REINFORCED SLAB, PRIOR
<br />RO THE FIRST POST-TENSIONED SLAB AND SEVERAL PERIODIC VISITS THEREAFTER, PERIODICALLY DURING FLOOR AND
<br />ROOF FRAMING AND AFTER ROOF DIAPHRAGM IS COMPLETE PRIOR TO ROOFING
<br />CONTRACTOR RESPONSIBILITY: PRIOR TO ISSUANCE OF THE BUILDING PERMIT, THE CONTRACTOR IS REQUIRED
<br />TO PROVIDE THE AUTHORITY HAVING JURISDICTION A SIGNED, WRITTEN ACKNOWLEDGEMENT OF THE
<br />CONTRACTOR'S RESPONSIBILITIES ASSOCIATED WITH THE ABOVE SATEMENT OF SPECIAL INSPECTIONS
<br />ADDRESSING THE REQUIREMENTS IN CBC SECTION 1704.4 CONTRACTOR IS REFERRED TO CBC SECTIONS
<br />1705.11.5 AND 1705.11.6 FOR ARCHITECTURAL AND MEP BUILDING SYSTEMS THAT MAY BE SUBJECT TO
<br />ADDITIONAL INSPECTIONS (BASED ON THE BUILDING'S DESIGNATED SEISMIC DESIGN CATEGORY LISTED IN THE
<br />CRITERIA), INCLUDING ANCHORAGE OF HVAC DUCTWORK CONTAINING HAZARDOUS MATERIALS, PIPING
<br />SYSTEMS AND MECHANICAL UNITS CONTAINING FLAMMABLE, COMBUSTIBLE OR HIGHLY TOXIC MATERIALS,
<br />ELECTRICAL EQUIPMENT USED FOR EMERGENCY OR STANDBY POWER, EXTERIOR WALL PANELS AND
<br />SUSPENDED CEILING SYSTEMS.
<br />PREFABRICATED CONSTRUCTION: ALL PREFABRICATED CONSTRUCTION SHALL CONFORM TO CBC SECTION 1703.
<br />SPECIAL INSPECTIONS (CBC 1705):
<br />SPECIAL INSPECTION SHALL BE COMPLETED BY A DEPUTY INSPECTOR
<br />LICENSED AND REGISTERED WITH THE GOVERNING BUILDING DEPT.
<br />CONCRETE OVER 2500 PSI
<br />ANCHORS INSTALLED IN CONCRETE
<br />DRIVEN DEEP FOUNDATIONS
<br />SMOKE CONTROL SYSTEM
<br />OTHER
<br />SHOTCRETE
<br />P
<br />P
<br />P
<br />C
<br />C
<br />C
<br />C
<br />P
<br />P/C
<br />C
<br />C
<br />C
<br />P/C
<br />* C: CONTINUOUS P: PERIODIC
<br />CBC 1705.3
<br />POST INSTALLED ANCHORS / EPOXY
<br />CBC TABLE 1705.3
<br />CBC TABLE 1705.3
<br />CBC TABLE 1705.3
<br />REINFORCING STEEL AND STEEL TENDONS CBC TABLE 1705.3
<br />STRUCTURAL STEEL
<br />STRUCTURAL STEEL WELDING
<br />CBC 1705.2 , 1705.12.1
<br />CBC 1705.2
<br />HIGH STRENGTH BOLTING CBC 1705.2
<br />MASONRY CONSTRUCTION CBC 1705.4
<br />HIGH-LOAD DIAPHRAGMS CBC 1705.5.1
<br />WOOD CONSTRUCTION CBC 1705.5, 1705.11.1
<br />COLD-FORMED STEEL CBC 1705.11.2
<br />CBC TABLE 1705.7
<br />SPRAY-APPLIED FIRE RESISTIVE MATERIALS
<br />SOILS CBC TABLE 1705.6
<br />CBC TABLE 1705.14
<br />CBC TABLE 1705.18
<br />REMARKSITEMSCODE REFERENCE TYPE
<br />SPECIAL INSPECTIONS
<br />SEE ALSO ICC APPROVAL
<br />SEE SOILS REPORT
<br />P/C
<br />P/C
<br />P
<br />SCOPE OF WORK
<br />PROJECT TEAM
<br />OWNER
<br />ARCHITECT
<br />CIVIL
<br />ENGINEER
<br />GEO
<br />ENGINEER
<br />ADU
<br />MLB CONSULTING AND ENGINEERING
<br />7918 FOOTHILL BLVD.
<br />SUNLAND, CA 91040
<br />Phone: (818) 521-6342
<br />Phone:
<br />SURVEYOR
<br />Phone:
<br />APPLICABLE BUILDING CODES
<br />2022 CALIFORNIA BUILDING CODE
<br />2022 CALIFORNIA RESIDENTIAL CODE
<br />2022 CALIFORNIA ELECTRIC CODE
<br />2022 CALIFORNIA PLUMBING CODE
<br />2022 CALIFORNIA MECHANICAL CODE
<br />2022 CALIFORNIA FIRE CODE
<br />2022 CALIFORNIA GREEN BUILDING STANDARDS
<br />AMENDMENTS PER LOCAL CITY ORDINANCE
<br />AMERICAN INSITUTE OF STEEL CONSTRUCTION, LATEST ADOPTED EDITION
<br />NDS WOOD DESIGN MANUAL, LATEST ADOPTED EDITION
<br />ASCE-7, LATEST ADOPTED EDITION
<br />AISC SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS
<br />ACI: BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND
<br />COMMENTARY
<br />2022 CBC
<br />2022 CRC
<br />2022 CEC
<br />2022 CPC
<br />2022 CMC
<br />2022 CFC
<br />CALGreen
<br />AISC
<br />NDS, NDS SUPPLEMENT,
<br />SDPWS
<br />ASCE7-16
<br />ACI 318-19
<br />AISC 341-16 S-0.10
<br />ST
<br />R
<br />U
<br />C
<br />T
<br />U
<br />R
<br />A
<br />L
<br />
<br />N
<br />O
<br />T
<br />E
<br />S
|