Laserfiche WebLink
DATE:11/14/2024 <br />JOB NO: MLB24-1210 <br />DESIGNED BY: HK <br />CHECKED BY: GB <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br />RE <br />V <br />BY <br />1 3 4 5 <br />- <br />2 <br />- <br />- <br />MLB CONSULTING AND <br />ENGINEERING, INC <br />7918 FOOTHILL BLVD <br />SUNLAND, CA 91040 <br />(818) 521-6342 <br />INFO@MLBENGINEERING.ORG <br />4703 W McFadden <br />Ave Santa Ana, CA <br />92704 <br />DATE:11/14/2024 <br />JOB NO: MLB24-1210 <br />DESIGNED BY: HK <br />CHECKED BY: GB <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br />RE <br />V <br />BY <br />1 3 4 5 <br />- <br />2 <br />- <br />- <br />MLB CONSULTING AND <br />ENGINEERING, INC <br />7918 FOOTHILL BLVD <br />SUNLAND, CA 91040 <br />(818) 521-6342 <br />INFO@MLBENGINEERING.ORG <br />4703 W McFadden <br />Ave Santa Ana, CA <br />92704 <br />SOILS AND FOUNDATIONS <br />REFERENCE STANDARDS: CBC CHAPTER 18 "SOILS AND FOUNDATIONS." <br />GEOTECHNICAL REPORT: PREPARED BY: NONE <br />CONTRACTOR'S RESPONSIBILITIES: CONTRACTOR SHALL BE RESPONSIBLE TO REVIEW THE GEOTECHNICAL <br />REPORT AND SHALL FOLLOW THE RECOMMENDATIONS SPECIFIIED THEREIN INCLUDING, BUT NOT LIMITED TO, <br />SUBGRADE PREPARATIONS, PILE INSTALLATION PROCEDURES, GROUND WATER MANAGEMENT AND STEEP <br />SLOPE BEST MANAGEMENT PRACTICES. <br />GEOTECHNICAL SUBGRADE INSPECTION: THE GEOTECHNICAL ENGINEER SHALL INSPECT ALL SUB-GRADES ND <br />PREPARE SOIL BEARING SURFACES, PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL AND <br />CONCRETE. GEOTECHNIAL ENGINEERS SHALL PROVIDE A LETTER TO THE OWNER STATING THAT SOULS ARE <br />ADEQUATE TO SUPPORT THE "ALLOWABLE FOUNDATION BEARING PRESSURE(S)" SHOWN BELOW. ASSUMED <br />VALUES SHALL BE FIELD VERIFIED BY THE BUILDING OFFICIAL OR THE GEOTECHNICAL ENGINEER PRIOR TO <br />PLACING CONCRETE. <br />ADVERSE SOILS: IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESITGATION REPORT MAY BE <br />REQUIRED UNLESS ALREADY PROVIDED FOR THIS PROJECT. <br />DESIGN SOIL VALUES: <br />ALLOWABLE FOUNDATION BEARING PRESSURE* <br />Continuous Footing <br />Isolated Pad Footing <br />D+L Short Term Allowable Bearing Surface <br />NATURAL GRADE1,500 <br />1,500 <br />2,660 <br />2,660 <br />* The above bearing value(s) may be increased by 150 psf for each additional foot of footing depth to a <br />maximum of 4,000 psf . The bearing capacity can be increased by one-third when considering short <br />duration wind or seismic loads. <br />LATERAL EARTH PRESSURE* <br />Active EFP (pcf) <br />30 65 <br />At-Rest EFP (pcf) <br />LEVEL BACKFILL <br />2:1 BACKFILL <br />1.5:1 BACKFILL <br />43 <br />55 <br />65 <br />65 <br />FOOTINGS: <br />FOOTING REQUIREMENTS <br />Min. Width <br />Cont. Ext. Ftg. <br />Int. Ext. Ftg. <br />Isolated Pad Footing <br />12" <br />12" <br />Min. Depth1 <br />24" <br />24" <br />Min. Embed. Into Approved <br />Weathered Bedrock <br />Min. Embed. Into Approved <br />Certified Fill <br />12" <br />12" <br />24" <br />24" <br />12"24"12"24" <br />PASSIVE LATERAL PRESSURE (LBS. PER CUBIC FT.) <br />- WITHIN WEATHERED BEDROCK OR FILL............................. 150 PCF <br />- MAX. ALLOW. FOR WEATHERED BEDROCK......................... 4,000 PCF <br />COEFFICIENT OF SLIDING FRICTION................................................. NONE <br />FOOTING DEPTH:TOPS OF FOOTINGS SHALL BE AS SHOWN ON PLANS WITH VERTICAL CHANGES AS INDICATED WITH <br />STEPS IN FOOTINGS; LOCATIONS OF STEPS SHOWN AND APPROXIMATE AND SHALL BE COORDINATED WITH THE CIVIL <br />GRADING PLANS. FOUNDATIONS SHALL BE EMBEDDED PER SCHEDULE ABOVE OR AS OTHERWISE INDICATED BY THE <br />GEOTECHNICAL ENGINEER OR BUILDING OFFICIAL. <br />CAST-IN PLACE CONCRETE <br />REFERENCE STANDARDS: CONFORM TO: <br />(1) ACI-301-10 "SPECIFICATIONS FOR STRUCTURAL CONCRETE" <br />(2) CBC CHAPTER 19 "CONCRETE" <br />(3) ACI 318-11/318R-11 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" <br />(4) ACI 117-10 "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS <br />FIELD REFERENCE: THE CONTRACTOR SHALL KEEP A COPY OF ACI FIELD REFERENCE MANUAL, SP-15, <br />"STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301) WITH SELECTED ACI AND ASTM <br />REFERENCES." <br />CONCRETE MIXTURES: CONFORM TO ACI 301 SECTION 4 "CONCRETE MIXTURES" AND CBC SECTION 1904.3 <br />MATERIALS: CONFORM TO ACI 301 SECTION 4.2.1 "MATERIALS FOR REQUIREMTNS FOR CEMENTITIOUS <br />MATERIALS, AGGREGATES, MIXING WATER AND ADMIXTURES. <br />SUBMITTALS: PROVIDE ALL SUBMITTALS REQUIRED BY ACI 301 SECTION 4.1.2. SUBMIT MIX DESIGNS FOR EACH <br />MIX IN THE TABLE BELOW. SUBSTANTIATING STRENGTH RESULTS FROM PAST TEST SHALL NOT BE OLDER <br />THAN 24 MONTHS PER ACI 318 SECTION 5.3. <br />TABLE OF MIX DESIGN REQUIREMENTS <br />MEMBER TYPE/ <br />LOCATION <br />STRENGTH <br />f'c (psi) <br />TEST AGE <br />(DAYS) <br />MAX. <br />AGGREGATE <br />EXPOSURE <br />CLASS <br />MAX. W/C <br />RATIO <br />AIR <br />CONTENT <br />NOTES (1-8 <br />TYP. UNO) <br />SLAB ON GRADE <br />FOOTINGS <br />ELEVATED SLABS <br />AND BEAMS <br />CONCRETE <br />COLUMNS <br />GRADE BEAMS <br />SITE RETAINING <br />WALLS <br />PILES <br />SHEAR WALLS <br />28 <br />28 <br />1" <br />SHOTCRETE WALLS <br />2500 <br />4000 <br />BASEMENT WALLS <br />2500 <br />4000 <br />3000 <br />4000 3/4" <br />4000 <br />4000 <br />3000 <br />3000 <br />TABLE OF MIX DESIGN REQUIREMENTS NOTES: <br />1. W/C RATIO : WATER-CEMENTATION MATERIAL RATIOS SHALL BE BE BASED ON THE TOTAL WEIGHT OF <br />CEMENTATION MATERIALS. MAXIMUM RATIOS ARE CONTROLLED BY STRENGTH NOTED IN THE MIX DESIGN <br />REQUIREMENTS AND DURABILITY REQUIREMENTS GIVEN IN ACI 318 SECTION 4.3. <br />2. CEMENTATION MATERIALS: <br />2.a. CEMENTATION MATERIAL TYPES SHALL CONFORM TO ACI 318 TABLE 4.3.1, BASED ON THE EXPOSURE <br />CLASSES INDICATED. <br />2.b. THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL CONFORM TO ACI 318 SECTIONS <br />4.4.2. MAXIMUM AMOUNT OF FLY ASH SHALL BE 25% OF TOTAL CEMENTATION CONTENT UNLESS <br />REVIEWED AND APPROVED OTHERWISE BY EOR. <br />2.c. FOR CONCRETE USED IN ELEVATED FLOORS, MINIMUM CEMENTATION-MATERIALS CONTENT SHALL <br />CONFORM TO ACI 301 TABLE 4.2.2.1. ACCEPTANCE OF LOWER CEMENT IS CONTINGENT ON PROVIDING <br />SUPPORTING DATA TO THE SER FOR REVIEW AND ACCEPTANCE. <br />2.d. CEMENTATION MATERIALS SHALL CONFORM TO THE RELEVANT ASTM STANDARDS LISTED IN ACI 318 <br />SECTION 3.2.1 <br />3. AIR CONTENT: CONFORM TO ACI 318 SECTION 4.4.1. MINIMUM STANDARDS FOR EXPOSURE CLASS ARE NOTED <br />IN THE TABLE. IF FREEZING AND THAWING CLASS IS NOT NOTED. AIR CONTENT GIVEN IS THAT REQUIRED BY <br />THE SER. TOLERANCE IS ±1-1/2%. AIR CONTENT SHALL BE MEASURED AT POINT OF PLACEMENT. <br />4. AGGREGATES SHALL CONFORM TO ASTM C33. <br />5. SLUMP: CONFORM TO ACI 301 SECTION 4.2.2.2. SLUMP SHALL BE DETERMINED AT POINT OF PLACEMENT. <br />6. CHLORIDE CONTENT: CONFORM TO ACI 318 SECTION 4.3.1. <br />7. NON-CHLORIDE ACCELERATOR: NON-CHLORIDE ACCELERATING ADMIXTURE MAY BE USED IN CONCRETE <br />PLACED AT THE AMBIENT TEMPERATURES BELOW 50°F AT THE CONTRACTOR'S OPTION. <br />8. ACI 318, SECTION 4.2.1 EXPOSURE CLASSES SHALL BE ASSUMED TO BE F0, S0, P0, AND C0 UNLESS DIFFERENT <br />EXPOSURE CLASSES ARE LISTED IN THE TABLE OF MIX DESIGN REQUIREMENTS THAT MODIFY THESE BASE <br />REQUIREMENTS. <br />9. SHRINKAGE LIMIT: CONCRETE USED IN ELEVATED SLABS AND BEAMS SHALL HAVE A SHRINKAGE LIMIT OF <br />0.045% AT 28 DAYS MEASURED IN ACCORDANCE WITH ASTM C157. SUBMIT LABORATORY TEST RESULTS TO <br />SER FOR APPROVAL PRIOR TO CONSTRUCTION. <br />FORMWORK & RESHORING: CONFORM TO ACI 301 SECTION 2 "FORMWORK AND FORM ACCESSORIES." <br />REMOVAL OF FORMS SHALL CONFORM TO SECTION 2.3.2 EXCEPT STRENGTH INDICATED IN SECTION <br />2.3.2.5 SHALL BE 0.75 f 'c. RESHORING SHALL CONFORM TO SECTION 2.3.3. IN ADDITION, MILD <br />REINFORCEMENT (NON POST-TENSIONED) SLABS SHALL BE CONTINUOUSLY RESHORED FOR A <br />MINIMUM OF 14 DAYS FOLLOWING PLACEMENT OF CONCRETE OR 7 DAYS AFTER CONCRETE HAS <br />REACHED 0.75 f 'c, WHICHEVER IS LONGER. CONTRACTOR SHALL SUBMIT FORMWORK REMOVAL AND <br />RESHORE INSTALLATION PROCEDURE AND DRAWINGS AS APPLICABLE SEALED BY A PROFESSIONAL <br />ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED FOR THE SER'S INFORMATION. <br />MEASURING, MIXING AND DELIVERY: CONFORM TO ACI 301 SECTION 4.3. <br />HANDLING, PLACING, CONSTRUCTING AND CURING: CONFORM TO ACI 301 SECTION 5. IN ADDITION, HOT WEATHER <br />CONCRETING SHALL CONFORM TO ACI 305.1-06 AND COLD WEATHER CONCRETING SHALL CONFORM TO ACI <br />306.1-90. <br />CONCRETE CURING: PROVIDE CURING COMPOUNDS FOR CONCRETE AS FOLLOWS. <br />1. USE MEMBRANE CURING COMPOUNDS THAT ARE COMPATIBLE WITH AND WILL NOT AFFECT SURFACES TO BE <br />COVERED WITH FINISH MATERIALS APPLIED DIRECTLY TO CONCRETE. <br />2. APPLY CURING COMPOUNDS AT A RATE EQUIVALENT TO THE RATE OF APPLICATION AT WHICH CURING <br />COMPOUND WAS ORIGINALLY TESTED FOR IN CONFORMANCE TO THE REQUIREMENTS OF ASTM C 309-07 <br />AND THE MANUFACTURER'S RECOMMENDATIONS. <br />3. SLUMP: CONFORM TO ACI 301 SECTION 4.2.2.2. SLUMP SHALL BE DETERMINED AT POINT OF PLACEMENT. <br />4. USE CURING COMPOUND COMPATIBLE WITH AND APPLIED UNDER DIRECTION OF SYSTEM MANUFACTURER <br />OF PROTECTIVE SEALER. <br />5. APPLY TWO SEPARATE COATS WITH FIRST ALLOWED TO BECOME TACKY BEFORE APPLYING SECOND. <br />DIRECTION OF SECOND APPLICATION SHALL BE AT RIGHT ANGLES TO THE DIRECTION OF FIRST. <br />CONCRETE REINFORCEMENT <br />REFERENCE STANDARDS: CONFORM TO: <br />1. ACI 301-10 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE", SECTON 3 "REINFORCEMENT <br />AND REINFORCEMENT SUPPORTS." <br />2. ACI SP-66-04 "ACI DETAILING MANUAL" INCLUDING ACI 315-99 "DETAILS AND DETAILING OF CONCRETE <br />REINFORCEMENT." <br />3. CRSI MSP-09, 28TH EDITION, "MANUAL OF STANDARD PRACTICE." <br />4. ANSI/AWS D1.4 "STRUCTURAL WELDING CODE - REINFORCING STEEL." <br />5. CBC CHAPTER 19-CONCRETE <br />6. ACI 318-19 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE." <br />7. ACI 117-10 "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS." <br />SUBMITTALS: CONFORM TO ACI 301 SECTION 3.1.1 "SUBMITTALS, DATA, AND DRAWINGS." SUBMIT PLACING <br />DRAWINGS SHOWING FABRICATION DIMENSIONS AND LOCATIONS FOR PLACEMENT OF REINFORCEMENT <br />AND REINFORCEMENT SUPPORTS. <br />MATERIALS: <br />REINFORCING BARS...................................................ASTM A615, GRADE 60, DEFORMED BARS. <br />WELDABLE REINFORCING BARS..............................ASTM A706, GRADE 60, DEFORMED BARS. <br />SMOOTH WELDED WIRE FABRIC..............................ASTM A185 <br />DEFORMED WELDED WIRE FABRIC..........................ASTM A497 <br />BAR SUPPORTS............................................................CRSI MSP-09, CHAPTER 3 "BAR SUPPORTS." <br />TIE WIRE.......................................................................16 GAGE OR HEAVIER, BLACK ANNEALED. <br />STUD RAILS...................................................................ASTM A1044 <br />HEADED DEFORMED BARS.........................................ASTM A970 <br />EARTHQUAKE REQUIREMENTS: LONGITUDINAL BARS IN SHEAR WALLS SHALL CONFORM TO ASTM A706, <br />GRADE 60 OR SHALL CONFORM TO THE FOLLOWING: <br />1.WELDING: WELDING IS NOT PERMITTE EXCEPT AS SPECIFIED IN THE DRAWINGS. WELD IN <br />ACCORDANCE WITH AWS D1.4 <br />2.MILL TESTS: SUBMIT MILL CERTIFICATES INDICATING PHYSICAL AND CHEMICAL PROPERTIES. <br />3.YIELD STRENGTH: ACTUAL YIELD STRENGTH, BASED ON MILL TESTS, DOES NOT EXCEED THE <br />SPECIFIED YIELD STRENGTH BY MORE THAN 18,000 PSI. (RETESTS SHALL NOT EXCEED THIS <br />4. VALUE BY MORE THAN AN ADDITIONAL 3000 PSI.) <br />FABRICATION: CONFORM TO ACI 301, SECTION 3.2.2. "FABRICATION", AND ACI SP66 "ACI DETAILING MANUAL. <br />CONCRETE COVER: CONFORM TO THE FOLLOWING REQUIREMENTS UNLESS NOTED OTHERWISE IN THE <br />DRAWINGS. <br />CONCRETE CAST AGAINST EARTH……………………….....3” <br />CONCRETE EXPOSED TO EARTH OR WEATHER………….2” <br />TIES IN COLUMNS AND BEAMS……………………………….1-1/2 “ <br />BARS IN SLABS……………………………………………….......1” <br />BARS IN WALLS……………………………………….................3/4” <br />SPLICES: CONFIRM TO ACI 301, SECTION 3.3.2.7, “SPLICES”. REFER TO “TYPICAL LAP SPLICE AND <br />DEVELOPMENT LENGTH SCHEDULE” FOR TYPICAL REINFORCEMENTS SPLICES. REFER TO “COLUMN <br />VERTICAL REINFORCING SPLICE SCHEDULE” FOR THOSE SPECIFIC ELEMENTS. SPLICES INDICATED ON <br />INDIVIDUAL SHEETS SHALL CONTROL OVER THE SCHEDULE. MECHANICAL CONNECTIONS MAY BE USED <br />WHEN APPROVED BY THE SER. FOR REINFORCING WITHIN THE LATERAL SYSTEM (SHEAR WALLS) AND <br />REINFORCING CONNECTING DIAPHRAGM SLAB TO THE LATERAL SYSTEM, MECHANICAL SPLICE STRENGTH <br />IS INCREASED TO DEVELOP 100 PERCENT OF THE SPECIFIED TENSILE STRENGTH OF THE SPLICES BAR. <br />STUDRAILS: WHERE STUDRAILS ARE INDICATED ON THE DRAWINGS THE FOLLOWING SYSTEMS ARE <br />ACCEPTABLE. STUDRAILS (ALSO REFERRED TO AS PUNCHING SHEAR RESISTOR RAILS) SHALL CONFORM <br />TO ASTM A1044 AND BE FABRICATED AND INSTALLED IN STRICT ACCORDANCE WITH THE APPLICABLE <br />ICC-ESR REPORT AND MANUFACTURER'S INSTRUCTIONS, USING CHAIR PROVIDED BY THE MANUFACTURER <br />TO POSITION RAILS AT THE PROPER HEIGHT. SUBMIT CURRENT MANUFACTURER'S DATA AND ICC ESR <br />REPORT OF ALTERNATE SYSTEMS TO SER FOR APPROVAL. <br />1. DECON “STUDRAILS” - ICC ESR-2494 <br />2. SIMPSON STRONG-TIE “PUNCHING SHEAR RESISTOR RAILS (PSRR) - ICC ESR-2992] <br />FIELD BENDING: CONFORM TO ACI 301 SECTION 3.3.2.8 “FIELD BENDING OR STRAIGHTENING.” BAR SIZES #3 <br />THROUGH #5 MAY BE FIELD BENT COLD FOR THE FIRST TIME. OTHER BARS REQUIRE PREHEATING. DO NOT <br />TWIST BARS. BARS SHALL NOT BE BENT PAST 45 DEGREES. <br />SHOTCRETE <br />REFERENCE STANDARDS: CONFORM TO: <br />1. CBC SECTION 1910 “SHOTCRETE”, <br />2. ACI 506.2-95 “SPECIFICATION FOR SHOTCRETE”' <br />3. ACI 506R-05 “GUIDE TO SHOTCRETE”, <br />4. ACI 301-10 “SPECIFICATIONS FOR STRUCTURAL CONCRETE.” <br />SUBMITTALS: SUBMIT SHOP DRAWINGS FOR REVIEW INCLUDING: <br />1. PROPOSED MIX DESIGN SHOWN BELOW. INCLUDE DATA REQUIRED BY ACI 506.2 SEC. 1.5 “SUBMITTALS” <br />2. PRECONSTRUCTION TEST PANEL RESULTS. AFTER SHOOTING, THE SPECIAL INSPECTOR SHALL SUBMIT CORE <br />EVALUATION REPORTS TO INSURE THAT PROPER REBAR ENCASEMENT AND NUZZLING TECHNIQUES HAVE <br />BEEN ACHIEVED. <br />3. CONSTRUCTION TEST SPECIMEN RESULTS. SPECIAL INSPECTOR SHALL SUBMIT CORE STRENGTH REPORTS. <br />MATERIALS: CONFORM ACI 506.2 SEC. 2 “MATERIALS” FOR CEMENTS, AGGREGATE, REINFORCEMENT , WATER, <br />ADMIXTURES AND CURING MATERIALS <br />REINFORCEMENT: CONFORM TO CBC SEC. 1910.4 “REINFORCEMENT” AND CONCRETE REINFORCEMENT SECTION <br />THIS SHEET. <br />SPLICES: CONFORM TO CBC SEC. 1910.4.3, “SPLICES”, FOR NON-CONTANT LAP SPLICES <br />PRECONSTRUCTION TESTS: PREPARE PRECONSTRUCTION TEST PANELS, AS DEFINED BY THE SER, FOR EACH <br />PROPOSED MIX DESIGN AND NOZZELMAN IN ACCORDANCE WITH CBC SEC 1910.5 “PRECONSTRUCTION TESTS” AND <br />ACI 506.3 SEC 2.6.2 “PRECONSTRUCTION TESTING”. TEST PANELS WILL BE CORED ARE MOST CONGESTED <br />REINFORCING AND EVALUATED BY THE TESTING LABORATORY. EACH NOZZELMAN MUST PASS THE EVALUATION <br />BEFORE PROCEEDING WITH THE WORK. <br />CONSTRUCTION TESTS: CONFORM TO CBC SEC 1910.10 “STRENGTH TESTS” AND ACI 506.2 SEC 1.6.2 <br />“CONSTRUCTION TESTING”. TAKE CORE SPECIMENS FOR EACH 50 CU YDS PLACED BUT NOT LESS THAN ONCE EACH <br />SHIFT. THE CORES MAY BE TAKEN FROM THE ACTUAL CONSTRUCTION WORK OR SAMPLE PANELS SHOT DURING THE <br />COURSE OF WORK. LOCATION OF CORES TAKEN FROM ACTUAL CONSTRUCTION WORK MUST BE APPROVED BY THE <br />SER PRIOR TO COMMENCING WORK. SAMPLE PANELS SHALL BE AT LEAST 12”X12”X7-1/4”. THREE CORES SHALL BE <br />TAKEN FROM EACH SAMPLE PANEL AND THE CORES MAY EITHER FIELD CURED OR LABORATORY CURED. <br />LABORATORY CURED SAMPLES HAVE AN AVERAGE STRENGTH EQUAL TO OR GREATER THAN F'C WITH NO <br />INDIVIDUAL SAMPLE BREAKING AT LESS THAN 0.75 F'C. FIELD SURED SAMPLES SHOULD HAVE AN AVERAGE <br />STRENGTH OF AT LEAST 85 F'C WITH NO INDIVIDUAL SAMPLES BREAKING AT LESS THAN 0.75 F'C. <br />CONSTRUCTION: CONFORMS TO CBC SEC 1910 AND ACI 506.2 SEC 3 “EXECUTION” FOR EXAMINATION, BATCHING <br />AND MIXING, SURFACE PREPARATION, JOINTS, ALIGNMENT CONTROL, APPLICATION, FINISHING, HOT WEATHER, <br />COLD WEATHER, PROTECTION, CURING, AND TOLERANCES. THE CONTRACTOR SHALL ADHERE TO THE FOLLOWING <br />WEATHER RELATED PRECAUTIONS. <br />REINFORCED UNIT MASONRY <br />REFERENCE STANDARDS: CONFORM TO: <br />1. CBC CHAPTER 21 “MASONRY.” <br />2.ACI 530-11/ASCE 5-11/TMS 402-11 “BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES.” HEREIN <br />REFERENCED AS MSJC. <br />3. ACI 530.1-11/ASCE 6-11/TMS 602-11 “SPECIFICATION FOR MASONRY STRUCTURES.” HEREIN REFERENCED AS <br />MSJC.1. <br />4. ACI SP-66 “ACI DETAILING MANUAL” INCLUDING ACI 315 “DETAILS AND DETAILING OF CONCRETE <br />REINFORCEMENT.” <br />5. ANSI/AWS D1.4 “STRUCTURAL WELDING CODE- REINFORCING STEEL.” <br />SUBMITTALS: CONFORM TO MSJC.1 SECTION 1.2. SUBMIT SHOP DRAWINGS FOR REVIEW INCLUDING: <br />1. MASONRY REINFORCEMENT, SIZE, LAYOUT, AND GRADE IN ACCORDANCE WITH PLANS. <br />2. MATERIAL CERTIFICATES FOR ALL STEEL REINFORCING, ANCHORS, TIES AND METAL ACCESSORIES <br />CERTIFYING COMPLIANCE WITH REQUIRED STRENGTH, GRADE AND ASTM STANDARDS. <br />3. CERTIFICATION LETTERS FOR MASONRY BLOCK AND GROUT MIX DESIGNS CERTIFYING COMPLIANCE WITH <br />REQUIRED STRENGTH AND RESPECTIVE ASTM STANDARDS \ <br />4. MIX DESIGNS FOR EACH GROUT MIX INDICATING TYPE AND PROPORTIONS OF INGREDIENTS IN COMPLIANCE <br />PROPORTION SPECIFICATION. <br />5. LOCATION OF EXPANSION AND CONTROL JOINTS. <br />6. PRODUCT INFORMATION, ICC ESR REPORTS AND MATERIAL CERTIFICATIONS CERTIFYING COMPLIANCE FOR <br />ALL NON-PRE-APPROVED POST-INSTALLED ANCHORS. <br />7. HOT AND/OR COLD WEATHER CONDUCTION PROCEDURES. <br />8. HIGH GROUT LIFT PROCEDURES. <br />STRENGTH: THE ASSUMED COMPRESSIVE STRENGTH OF MASONRY ASSEMBLAGE, F'M, IS 1500 PSI BASED ON CBC <br />SECTION 2015.2.2.1.2 FOR CONCRETE MASONRY. <br />MATERIALS: <br />1.CONCRETE MASONRY UNITS: CONFORM TO ASTM C 90, TYPE-I (MOISTURE CONTROLLED), MEDIUM WEIGHT <br />(APPROX. 115 PCF) UNITS. PROVIDE 1900 PSI COMPRESSIVE STRENGTH TO ACHIEVE MASONRY ASSEMBLY <br />STRENGTH INDICATED ABOVE UNDER STRENGTH <br />2.MORTAR: CONFORM TO ASTM C270, TYPE S, AND CBC SECTION 2103.9 “MORTAR.” <br />3.GROUT: CONFORM TO ASTM C476 AND CBC SECTION 2103.13 PROPORTION SPECIFICATION. <br />4.REINFORCING BARS: CONFORM TO ASTM A615, GRADE 60 DEFORMED BARS AND CBC SECTION 2103.14 UNLESS <br />NOTED OTHERWISE. LAP SPLICES SHALL BE AS NOTED ON PLANS. FABRICATION SHALL BE IN ACCORDANCE <br />WITH MSJC.1 SECTION 2.7. <br />5.JOINT REINFORCEMENT: CONFORM TO ASTM A951 AND CBC SECTION 2103.14. <br />6.ANCHORS, TIES AND ACCESSORIES: CONFORM TO CBC SECTION 2103.14 AND MSJC.1 SECTION 2.4D. <br />7.WATER: SHALL BE CLEAN AND POTABLE <br />8.ADMIXTURES: ADMIXTURES SHALL NOT BE USED UNLESS APPROVED BY SER. <br />9.POST-INSTALLED ANCHORS IN MASONRY: REFERENCE THE POST-INNSTALLED ANCHORS SECTION FOR <br />APPLICABLE POST-INSTALLED ANCHORS IN MASONRY. <br />10.SECOND-HAND UNITS: SHALL NOT BE USED UNLESS APPROVED BY EOR <br />QUALITY ASSURANCE: CONFORM TO CBC SECTION 2105 “QUALITY ASSURANCE” <br />1.MASONRY UNITS: A LETTER OF CERTIFICATION FROM THE MANUFACTURER OF THE UNITS SHALL BE PROVIDED <br />TO THE SER PRIOR TO THE DELIVERY OF THE UNITS TO THE JOBSITE TO ENSURE THE UNITS COMPLY WITH THE <br />COMPRESSIVE STRENGTH SPECIFIED ABOVE AND ASTM C 90. <br />2.MORTAR: NO MORTAR TESTING IS REQUIRED. <br />3.GROUT: A LETTER OF CERTIFICATION FROM THE SUPPLIER OF THE GROUT SHALL BE PROVIDED TO THE EOR <br />PRIOR TO DELIVERY OF THE GROUT TO THE JOBSITE TO ENSURE THAT THE GROUT COMPLIES WITH ASTM C <br />476. <br />DELIVERY, STORAGE AND HANDLING: DELIVERY, STORAGE AND HANDLING OF MATERIALS USED FOR MASONRY <br />CONSTRUCTION SHALL BE PER MSJC.1, SECTION 1.7. <br />SPECIAL INSPECTION: SPECIAL INSPECTIONS SHALL BE PERFORMED PER THE “TESTS AND INSPECTIONS” SECTION <br />OF THE STRUCTURAL GENERAL NOTES <br />ANCHORS, TIES AND CONNECTORS: MASONRY ANCHORS, TIES AND CONNECTORS SHALL BE A SPECIFIED ON <br />STRUCTURAL DRAWINGS. CONSULT ARCHITECTURAL DRAWINGS FOR MASONRY ANCHOR TIES NOT INCLUDED ON <br />THE STRUCTURAL DRAWINGS. <br />EMBEDDED ITEMS: EMBEDDED ITEMS AND ACCESSORIES SHALL BE IN ACCORDANCE WITH MSJC SECTION 1.15 AND <br />INSTALLED IN ACCORDANCE WITH MSJC.1 SECTION 3.3D. POSITION AND SECURE IN PLACE EXPANSION JOINT <br />MATERIAL, ANCHORS AND OTHER STRUCTURAL AND NON-STRUCTURAL EMBEDDED ITEMS BEFORE PLACING GROUT. <br />CONTRACTOR SHALL REFER TO STRUCTURAL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, ETC. AND <br />COORDINATE ALL EMBEDDED ITEMS. <br />POST-INSTALLED ANCHORS TO MASONRY: ANCHOR LOCATIONS, TYPE, DIAMETER AND EMBEDMENT SHALL BE AS <br />INDICATED ON DRAWINGS. REFERENCE THE POST INSTALLED ANCHORS SECTION FOR APPLICABLE POST-INSTALLED <br />ANCHOR ADHESIVES. ANCHORS SHALL BE INSTALLED AND INSPECTED IN STRICT ACCORDANCE WITH THE <br />APPLICABLE ICC-EVALUATION SERVICE REPORT (ESR). SPECIAL INSPECTION SHALL BE PER THE TEST AND <br />INSPECTIONS SECTION. <br />MASONRY REINFORCING STEEL: MASONRY REINFORCING SHALL BE AS NOTED ON PLANS AND SHALL BE SECURELY <br />PLACED IN ACCORDANCE WITH CBC SECTIONS 2104.1.1, 2106, AND 2108 AND MSJC SECTION 1.16. UNLESS OTHERWISE <br />NOTED ON THE PLANS, THE MINIMUM WALL REINFORCEMENT SHALL BE AS FOLLOWS: <br />BOND BEAMS WITH HORIZONTAL BAR OR BARS SHALL BE PROVIDED AT 48 INCHES ON CENTER MINIMUM AND AT ALL <br />FLOOR AND ROOF LINES AND AT THE TOP OF THE WALL. PROVIDE A BOND BEAM WITH HORIZONTAL BAR OR BARS <br />OVER ALL OPENINGS, AND EXTEND THESE BARS 2'-0” PAST THE OPENING AT EACH SIDE. PROVIDE A BAR OR BARS <br />VERTICALLY FOR THE FULL HEIGHT OF THE WALL AT EACH SIDE OF OPENINGS, WALL ENDS AND INTERSECTIONS. <br />DOWELS TO MASONRY WALLS SHALL BE EMBEDDED A MINIMUM OF 1'-6” OR HOOKED INTO SUPPORTING STRUCTURE <br />AND BE OF THE SAME SIZE AND SPACING AS WALL REINFORCING. REINFORCING STEEL SHALL BE AS SPECIFIED <br />UNDER “MATERIALS” SECTION. PROVIDE CORNER BARS TO MATCH THE HORIZONTAL WALL REINFORCING AT ALL <br />WALL INTERSECTIONS. ALL BARS SHALL BE LAPPED A MINIMUM 48 DIAMETERS OR 1'-6” MINIMUM UNLESS NOTED ON <br />THE PLANS. <br />LINTELS: REINFORCED MASONRY LINTELS TO BE INSTALLED OVER ALL OPENINGS UNLESS OTHERWISE INDICATED ON <br />DRAWINGS. DO NOT SPLICE REINFORCING BARS WITHIN LINTELS AND MAINTAIN 8 INCH BEARING MINIMUM ON EACH <br />SIDE. UNLESS OTHERWISE NOTED ON THE PLANS, THE MINIMUM REINFORCEMENT FOR LINTELS IN 8” MASONRY <br />SHALL BE AS FOLLOWS: <br />1.OPENINGS UP TO 42 INCHES WIDE: (2) #4 AT THE BOTTOM WEB OF 8 INCH DEEP LINTEL <br />2.OPENINGS 42 TO 78 INCHES WIDE: (2) #4 AT BOTTOM WEB OF 16 INCH DEEP LINTEL <br />3.OPENINGS OVER 78 INCHES WIDE: REINFORCE PER DRAWINGS <br />CONSTRUCTION: MASONRY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CBC SECTION 2104 “CONSTRUCTION”, <br />AND MSJC.1 PART 3 “EXECUTION.” <br />COLD AND HOT WEATHER CONSTRUCTION: COLD AND HOT WEATHER CONSTRUCTION SHALL BE IN ACCORDANCE <br />WITH SECTION 2104.3 AND 2104.4. <br />BLOCK PATTERN: USE RUNNING BOND UNLESS NOTED. FOR STACK BOND, FOLLOW CRITERIA IN MSJC SECTION 1.11. <br />GROUTED CELLS: FILL ALL CELLS WITH GROUT UNLESS NOTED OTHERWISE N PLANS. MINIMUM GROUTING SPACES <br />AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH MSJC SECTION 1.16 AND MSJC SECTION 3.5. <br />GROUT POUR HEIGHT; GROUT POUR HEIGHT SHALL NOT EXCEED HEIGHT SPECIFIED IN MSJC.1 SECTION 3.5C. <br />·MASONRY BOCKS SHALL BE ADEQUATELY BRACED TO WITHSTAND FLUID PRESSURES OR GROUT POUR, <br />SEE TEMPORARY BRACING. <br />GROUT LIFTS: UNLESS OTHERWISE NOTES, GROUT LIFTS AND POUR HEIGHT SHALL NOT EXCEED 5FT 4IN. GROUT <br />LIFTS SHALL NOT EXCEED SPACING OF INTERMEDIATE REINFORCED BOND BEAMS. GROUT LIFTS EXCEEDING 5FT 4IN <br />SHALL BE APPROVED BY SER. <br />REINFORCING COVER AND CLEARANCE REQUIREMENTS: UNLESS OTHERWISE NOTED: <br />CLEAR DISTANCE BETWEEN PARALLEL BARS (AND BETWEEN ADJACENT PAIRS OF LAP SPLICED BARS) SHALL BE <br />EQUAL TO THE BAR ADJACENT BAR DIAMETER (FOR BARS GREATER THAN #8), AND NOT LESS THAN: <br />1. 1” AT 8” AND SMALLER BLOCK, <br />2. 2” AT 10” BLOCK <br />3. 3” AT 12” BLOCK <br />CLEARANCE (CLEAR SPACE) BETWEEN THE BLOCK AND REINFORCING SHALL BE: <br />1. ¼” AT FINE GROUT <br />2. ½” AT COURSE GROUT <br />MASONRY COVER (INCLUDING GROUT AND BLOCK WALL) AT MASONRY FACE EXPOSED TO EARTH OR WEATHER <br />SHALL BE: <br />1. 1 ½” MINIMUM <br />2. 2” FOR BARS #6 AND LARGER <br />CONTROL AND EXPANSION JOINTS: REFERENCE DRAWINGS FOR TYPICAL DETAILS OF MASONRY CONTROL AND <br />EXPANSION JOINTS. LOCATION OF CONTROL AND EXPANSIONS JOINTS SHALL BE APPROVED BY SER. UNLESS <br />OTHERWISE INDICATED ON DRAWINGS, INSTALL CONTROL AND EXPANSION JOINTS AT THE FOLLOWING: <br />1.CONTINUOUS WALLS: VERTICAL JOINTS AT THE LESSER OF 1.5 TIMES THE WALL HEIGHT OR 25 FEET ON <br />CENTER MAXIMUM. <br />2.CORNERS AND INTERSECTING WALLS: FIRST VERTICAL JOINT FROM THE CORNER AT LESSER OF 1.2 TIMES THE <br />WALL HEIGHT OR 16 FEET. <br />3.ABRUPT CHANGES IN WALL HEIGHT AND WALL THICKNESS, SUCH AS ADJACENT TO COLUMNS OR PILASTERS. <br />TEMPORARY BRACING: CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING OF MASONRY DURING <br />CONSTRUCTION. REFERENCE “CONTRACTOR RESPONSIBILITIES” SECTION FOR FURTHER INFORMATION AND <br />REQUIREMENTS. <br />POST-INSTALLED ANCHORS (INTO CONCRETE AND MASONRY) <br />REFERENCE STANDARDS: CONFORM TO: <br />1. CBC CHAPTER 19 “CONCRETE” <br />2. ACI 318-11 “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE” <br />3. CBC CHAPTER 21 “MASONRY” <br />4. ACI 530-11/ASCE 5-11/TMS402-11 “BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES” <br />POST-INSTALLED ANCHORS: INSTALL ONLY WHERE SPECIFICALLY SHOWN IN DETAILS AND PLANS OR ALLOWED BY <br />EOR. ALL POST-INSTALLED ANCHORS TYPES AND LOCATIONS SHALL BE APPROVED BY THE EOR AND SHALL HAVE A <br />CURRENT ICC-EVALUATIONS SERVICE REPORT THAT PROVIDES RELEVANT DESIGNS VALUES NECESSARY TO <br />VALIDATE THE AVAILABLE STRENGTH EXCEEDS THE REQUIRED STRENGTH. ANCHORS SHALL BE INSTALLED IN <br />STRICT ACCORDANCE TO ICC-ESR AND MANUFACTURER'S INSTRUCTIONS. NO REINFORCING BARS SHALL BE <br />DAMAGED DURING INSTALLATION OF POST-INSTALLED ANCHORS. SPECIAL INSPECTION SHALL BE PER THE TESTS <br />AND INSPECTIONS SECTION. ANCHOR TYPE, DIAMETER AND EMBEDMENT SHALL BE AS INDICATED ON DRAWINGS. <br />1.ADHESIVE ANCHORS: THE FOLLOWING ADHESIVE-TYPE ANCHORING SYSTEMS HAVE BEEN USED IN THE DESIGN <br />AND SHALL BE USED FOR ANCHORAGE TO CONCRETE AND MASONRY, AS APPLICABLE AND IN ACCORDANCE <br />WITH CORRESPONDING CURRENT ICC ESR REPORT. DRILLED-IN ANCHOR EMBEDMENT LENGTHS SHALL BE AS <br />SHOWN ON DRAWINGS, OR NOT LESS THAN 7 TIMES THE ANCHOR NOMINAL DIAMETER (7D). <br />a. HILTI “HIT-HY 200” - ICC ESR- 3187 FOR ANCHORAGE TO CONCRETE WITH MIN EMBEDMENT DEPTH OF 20 BAR <br />DIAMETERS <br />b. HILTI “HIT-HY 500 SD”- ICC ESR 2322 FOR CONCRETE ONLY <br />c. SIMPSON “SET-XP”- ICC ESR 2508 FOR ANCHORAGE TO CONCRETE IAPMO 265 FOR ANCHORAGE TO MASONRY <br />d. POWERS “PE1000”-ICC ESR 2583 FOR ANCHORAGE TO CONCRETE <br />e. HILTI “HY-150 MAX”-ICC ESR-1967- FOR ANCHORAGE TO MASONRY ONLY <br />2.EXPANSION ANCHORS: THE FOLLOWING EXPANSION TYPE ANCHORS ARE PRE-APPROVED FOR ANCHORAGE TO <br />CONCRETE OR MASONRY IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT: <br />a. HILTI “KWIK BOLT TZ”- ICC ESR-1917 FOR CONCRETE ONLY <br />b. SIMPSON “STORNG-BOLT 2” - ICC ESR-3037 FOR CONCRETE ONLY <br />c. POWERS “POWER-STUD+SD1”- ICC ESR-28181 FOR CONCRETE ONLY AND ICC ESR-2966 FOR MASONRY ONLY <br />d. HILTI “KWIK BOLT 3- ICC ESR-1385 FOR ANCHORAGE TO MASONRY ONLY <br />e. SIMPSON “WEDGE-ALL” ICC ESR-1396 FOR ANCHORAGE TO MASONRY ONLY <br />3.SCREW ANCHORS: THE FOLLOWING SCREW TYPE ANCHOR IS PRE-APPROVED FOR ANCHORAGE TO CONCRETE <br />OR MASONRY IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT: <br />a. SIMPSON “TITAN HD”-ICC ESR-2713 FOR CONCRETE ONLY AND ICC ESR-1056 FOR MASONRY ONLY <br />b. POWERS “WEDGE-BOLT +” - ICC ESR 2526 FOR CONCRETE ONLY AND ICC ESR 1678 FOR MASONRY ONLY <br />c. POWERS “SNAKE”-ICC ESR 2272 FOR ANCHORAGE TO CONCRETE ONLY <br />d. HILTI “HUS-EZ” - ICC ESR 3027 FOR ANCHORAGE TO CONCRETE ONLY AND ICC ESR-3056 FOR MASONRY ONLY28 <br />28 <br />28 <br />28 <br />28 <br />28 <br />28 <br />28 <br />3/4" <br />1" <br />3/4" <br />1" <br />1" <br />1" <br />0.40 <br />0.50 <br />0.50 <br />0.50 <br />0.50 <br />0.50 <br />0.50 <br />0.50 <br />0.50 <br />0.45 <br />S-0.11 <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S