DATE:11/14/2024
<br />JOB NO: MLB24-1210
<br />DESIGNED BY: HK
<br />CHECKED BY: GB
<br />DE
<br />S
<br />C
<br />R
<br />I
<br />P
<br />T
<br />I
<br />O
<br />N
<br />DA
<br />T
<br />E
<br />RE
<br />V
<br />BY
<br />1 3 4 5
<br />-
<br />2
<br />-
<br />-
<br />MLB CONSULTING AND
<br />ENGINEERING, INC
<br />7918 FOOTHILL BLVD
<br />SUNLAND, CA 91040
<br />(818) 521-6342
<br />INFO@MLBENGINEERING.ORG
<br />4703 W McFadden
<br />Ave Santa Ana, CA
<br />92704
<br />DATE:11/14/2024
<br />JOB NO: MLB24-1210
<br />DESIGNED BY: HK
<br />CHECKED BY: GB
<br />DE
<br />S
<br />C
<br />R
<br />I
<br />P
<br />T
<br />I
<br />O
<br />N
<br />DA
<br />T
<br />E
<br />RE
<br />V
<br />BY
<br />1 3 4 5
<br />-
<br />2
<br />-
<br />-
<br />MLB CONSULTING AND
<br />ENGINEERING, INC
<br />7918 FOOTHILL BLVD
<br />SUNLAND, CA 91040
<br />(818) 521-6342
<br />INFO@MLBENGINEERING.ORG
<br />4703 W McFadden
<br />Ave Santa Ana, CA
<br />92704
<br />P/BC 2017-024
<br />GENERAL NOTES FOR STRUCTURAL OBSERVATION
<br />(1) Structural Observation is required for the structural system in accordance with the Information Bulletin
<br />No. P/BC 2017-024. Structural Observation is the visual observation at the construction site of the
<br />elements and connections of the structural system at significant construction stages, and the
<br />complete structure for general conformance to the approved plans and specifications. Structural
<br />Observation does not waive the responsibility for the inspections required of the building inspector
<br />or the deputy inspector.
<br />(2) The owner shall employ a State of California registered civil or structural engineer or licensed architect
<br />to perform the Structural Observation. The Los Angeles Department of Building and Safety (LADBS)
<br />requires the use of the engineer or architect, or his/her designee responsible for the structural design
<br />who are independent of the contractor.
<br />(3) The Structural Observer shall provide evidence of employment by the owner or the owner’s
<br />representative. A letter from the owner, the owner’s representative, or a copy of the agreement for
<br />services shall be sent to the building inspector before the first site visit.
<br />(4) The owner or owner's representative shall coordinate and call for a meeting between the engineer or
<br />architect responsible for the structural design, Structural Observer, contractor, affected subcontractors
<br />and deputy inspectors. The purpose of the meeting shall be to identify the major structural elements
<br />and connections that affect the vertical and lateral load systems of the structure and to review
<br />scheduling of the required observations. A record of the meeting shall be included in the first
<br />observation report submitted to the building inspector.
<br />(5) The Structural Observer shall perform site visits at those steps in the progress of the work that allow
<br />for correction of deficiencies without substantial effort or uncovering of the work involved. At a
<br />minimum, the listed significant construction stages on either the “Structural Observation/Significant
<br />Construction Stages” form or the “Structural Observation Program and Designation of the Structural
<br />Observer” form IN/Form.08 (Part 2) require a site visit and an observation report from the Structural
<br />Observer.
<br />(6) The Structural Observer shall prepare a report of the “Structural Observation Report Form”
<br />IN/Form.08 (Part 1) for each significant stage of construction observed. The original of the Structural
<br />Observation report shall be sent to the building inspector's office and shall be signed and sealed (wet
<br />stamp) by the responsible Structural Observer. One copy of the observation report shall be attached
<br />to the approved plans. The copy attached to the plans shall be signed and sealed (wet stamp) by the
<br />responsible Structural Observer or their designee. Copies of the report shall also be given to the
<br />owner, contractor, and deputy inspector. Any deficiency noted on the observation report will become
<br />the responsibility of the structural engineer or architect of record to verify its completion by the
<br />Structural Observer.
<br />(7) A final observation report must be submitted which shows that all observed deficiencies were resolved
<br />and structural system generally conforms with the approved plans and specifications. The Los
<br />Angeles Department of Building and Safety (LADBS) will not accept the structural work without the
<br />final observation report and the correction of specific deficiencies noted during normal building
<br />inspection.
<br />(8) The Structural Observer shall provide the original stamped and signed “Structural Observation Report
<br />Form” to the City of Los Angeles Department of Building and Safety Building Inspector.
<br />(9) When there is a need to replace the Structural Observer of record, the owner shall:
<br />a) Notify the building inspector in writing before the next inspection by submitting completed
<br />“Structural Observation Program and Designation of the Structural Observer” form IN/Form.08
<br />(Part 2).
<br />b) Call an additional preconstruction meeting, and
<br />c) Furnish the replacement Structural Observer with a copy of all previous observation reports.
<br />d) The new Structural Observer must be designated by the engineer or architect of record.
<br />The replacement Structural Observer shall approve the correction of the original observed deficiencies
<br />unless otherwise approved by plan check supervision. The policy of the Department shall be to correct
<br />any properly noted deficiencies without consideration of their source.
<br />(10) The engineer or architect of record shall develop all changes relating to the structural systems. The
<br />building department shall review and approve all changes to the approved plans and specifications.
<br />FOUNDATION
<br />(required if the Structural Observer is
<br />Signature License No. Date
<br />_________________________________________________________
<br />individual is designated by me to be responsible for the Structural Observation.
<br />I, the Architect or Engineer of record for the project, declare that the above listed firm or
<br />DECLARATION BY ARCHITECT OR ENGINEER OF RECORD
<br />different from the Architect or Engineer of Record)
<br />Signature Date
<br />________________________________________
<br />DECLARATION BY OWNER
<br />I, the Owner of the project, declare that the above listed firm or individual is hired
<br />Structural Observer.
<br />STRUCTURAL OBSERVATION PROGRAM
<br />AND DESIGNATION OF THE
<br />STRUCTURAL OBSERVER
<br />Owner:__________________ Architect:____________________ Engineer:_____________________
<br />Description of Work:
<br />PROJECT ADDRESS: 4703 W MCFADDEN AVE PERMIT APPL. NO.:___________________
<br />(only checked items are required)
<br />STRUCTURAL OBSERVATION
<br />Firm or Individual to be responsible for the Structural Observation:
<br />Name: Phone: (818) 521-6342 Calif. Registration: C76761
<br />DIAPHRAGMFRAMEWALL
<br />Others:
<br />Others:
<br />Wood
<br />Steel Deck
<br />ConcreteSteel Moment Frame
<br />Steel Braced Frame
<br />Concrete Moment Frame
<br />Masonry Wall Frame
<br />Concrete
<br />Masonry
<br />Wood
<br />Others:
<br />Others:
<br />Hillside Special Anchors
<br />Stepp' g/Retain' g Foundation,
<br />Caisson, Piles, Grade Beams
<br />Mat Foundation
<br />Footing, Stem Walls, Piers
<br />by me to be the
<br /> REQUIRED NOTES ON PLANS
<br />MATERIAL SPECIFICATION & INSPECTIONS
<br />1.CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC
<br />FORCE RESISTING SYSTEM/COMPONENT LISTED IN
<br />THE STATEMENT OF SPECIAL INSPECTION SHALL SUBMIT A WRITTEN
<br />STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER
<br />PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR
<br />COMPONENT. (1704.4)
<br />2.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS
<br />REQUIRED FOR FIELD WELDING, POST-INSTALLED ADHESIVE ANCHORS
<br />INSTALLED HORIZONTALLY OR UPWARDLY INCLINED TO RESIST TENSION
<br />LOADS, SHOTCRETE PLACEMENT, CONCRETE STRENGTH f 'c > 2500 PSI,
<br />SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, , HIGH
<br />LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES, AND
<br />HELICAL PILE FOUNDATIONS. (1705 & CHAPTERS 19, 21, AND 22)
<br />3. FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED
<br />WOOD. (2304.12.1.4)
<br />4.FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE LADBS FOR
<br />(STRUCTURAL STEEL)(REINFORCING STEEL)(LIGHT GAUGE STEEL). CONTINUOUS
<br />INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED.
<br />5. SHOP WELDS MUST BE PERFORMED IN A LADBS LICENSED FABRICATOR'S SHOP.
<br />6. LADBS LICENSED FABRICATOR IS REQUIRED FOR (TRUSSES), (STRUCTURAL STEEL).
<br />7. GLUED-LAMINATED TIMBERS MUST BE FABRICATED IN A LADBS LICENSED SHOP.
<br />IDENTITY GRADE SYMBOL AND LAMINATION SPECIES PER 2018 NDS SUPPLEMENT
<br />TABLE 5A.
<br />8.PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL
<br />DIAMETER FOR SMOOTH SHANK PORTION.\
<br />9.PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR
<br />PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND
<br />OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM.
<br />SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED WHERE THE
<br />FASTENER SPACING OF THE SHEATHING IS 4 INCHES ON CENTER OR LESS.
<br />(1707.5.12.2)
<br />10.SPECIAL ACTIVITY INSPECTION IS REQUIRED FOR (BUILDINGS OVER 5 STORIES OR
<br />60' IN HEIGHT) (BUILDINGS OVER 50,000 SQ. FT. OF GROUND FLOOR AREA)
<br />(BUILDING OVER 200,000 SQ. FT. OF TOTAL FLOOR AREA.) (1705.1.6)
<br />11.A COPY OF THE LOS ANGELES RESEARCH REPORT AND/OR CONDITIONS OF
<br />LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE.
<br />FOUNDATIONS AND GRADING
<br />1.IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION
<br />REPORT MAY BE REQUIRED.
<br />SHEAR WALLS
<br />1. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE
<br />WASHERS; AND HOLD-DOWNS SHALL BE FINGER TIGHT AND ½ WRENCH TURN
<br />JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD
<br />FRAMING REQUIRE STEEL PLATE WASHERS ON THE POST ON THE OPPOSITE
<br />SIDE OF THE ANCHORAGE DEVICE. PLATE SIZE SHALL BE A MINIMUM OF 0.299
<br />INCH BY 3 INCHES BY 3 INCHES. (2305.5)
<br />2. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING". FACE GRAIN OF
<br />PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE
<br />AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM
<br />WITH TABLE 2304.8(1).
<br />3.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR
<br />GALVANIZED BOX.
<br />4. ALL BOLT HOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED. (NDS 12.1.3.2)
<br />5.HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION
<br />INSPECTION.
<br />S-0.14
<br />ST
<br />R
<br />U
<br />C
<br />T
<br />U
<br />R
<br />A
<br />L
<br />
<br />N
<br />O
<br />T
<br />E
<br />S
<br />GEGAM BURNAZYAN
<br />MLB CONSULTING AND ENGINEERING
<br />SHALL BE ENGINEER OF RECORD
<br />ADU
|