MEMBER SIZES SPECIES COMB. SYMBOL USES <br />Beams All DF/DF 24F-V4 Simple Spans <br />Beams All DF/DF 24F-V4 Continuous or with Cantilever Spans <br />Columns All DF L2 Post, Truss Member <br />DATE:11/14/2024 <br />JOB NO: MLB24-1210 <br />DESIGNED BY: HK <br />CHECKED BY: GB <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br />RE <br />V <br />BY <br />1 3 4 5 <br />- <br />2 <br />- <br />- <br />MLB CONSULTING AND <br />ENGINEERING, INC <br />7918 FOOTHILL BLVD <br />SUNLAND, CA 91040 <br />(818) 521-6342 <br />INFO@MLBENGINEERING.ORG <br />4703 W McFadden <br />Ave Santa Ana, CA <br />92704 <br />DATE:11/14/2024 <br />JOB NO: MLB24-1210 <br />DESIGNED BY: HK <br />CHECKED BY: GB <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br />RE <br />V <br />BY <br />1 3 4 5 <br />- <br />2 <br />- <br />- <br />MLB CONSULTING AND <br />ENGINEERING, INC <br />7918 FOOTHILL BLVD <br />SUNLAND, CA 91040 <br />(818) 521-6342 <br />INFO@MLBENGINEERING.ORG <br />4703 W McFadden <br />Ave Santa Ana, CA <br />92704 <br />WOOD FRAMING <br />REFERENCE STANDARDS: CONFORM TO: <br />1. CBC CHAPTER 23 "WOOD" <br />2. NDS - "2018 NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION <br />3. ANSI/AWS - SDPWS-2015: SPECIAL DESIGN PROVISIONS FOR WIND & SEISMIC WITH <br />COMMENTARY <br />4. APA PDS-04 PLYWOOD DESIGN SPECIFICATIONS <br />5. ANSI/TPI 1-2007 "NATIONAL DESIGN STANDARD FOR METAL-PLATE-CONNECTED WOOD TRUSS <br />CONSTRUCTION" <br />6. BCSI "GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING & BRACING OF METAL PLATED <br />CONNECTED WOOD TRUSSES. <br />7. TPI DSB "RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING OF METAL PLATE <br />CONNECTED WOOD TRUSSES" <br />8. APA REPORT TT-045B "MINIMUM NAIL PENETRATION FOR WOOD STRUCTURAL PANEL <br />CONNECTIONS SUBJECT <br />9. TO LATERAL LOADS" <br />SUBMITTALS: SUBMIT SHOP DRAWINGS TO ARCHITECT/ENGINEER FOR REVIEW. SHOP DRAWINGS <br />SHALL INCLUDE MEMBER SIZE, SPACING, CAMBER, MATERIAL TYPE, GRADE, SHOP AND FIELD <br />ASSEMBLY DETAILS AND CONNECTIONS, TYPES AND LOCATION OF BOLTS AND OTHER FASTENERS. <br />SUPPLY SHOP DRAWINGS FOR THE FOLLOWING: <br />1. GLUED LAMINATED MEMBERS <br />2. PSL MEMBERS <br />3. LVL MEMBERS <br />4. LSL MEMBERS <br />5. TAPERED & PARALLEL WOOD I JOISTS (SOLID WEB-WOOD JOISTS) <br />6. PANELIZED WOOD WALLS & CONNECTION DETAILS <br />7. WOOD TIE-DOWN SYSTEMS <br />DEFERRED SUBMITTALS: SUBMIT PRODUCT DATA AND PROOF OF ICC APPROVAL FOR FRAMING <br />MEMBERS AND FASTENERS THAT HAVE BEEN DESIGNED BY OTHERS. SUBMIT CALCULATIONS <br />PREPARED BY THE EOR IN THE STATE OF CALIFORNIA FOR ALL MEMBERS AND CONNECTIONS DESIGN <br />BY OTHERS ALONG WITH SHOP DRAWINGS. ALL NECESSARY BRIDGING, BLOCKING, BLOCKING PANELS <br />AND WEB STIFFENERS SHALL BE DETAILED AND FURNISHED BY THE SUPPLIER. TEMPORARY AND <br />PERMANENT BRIDGING SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S <br />SPECIFICATIONS. DEFLECTION LIMITS SHALL BE NOTED UNDER "DEFERRED SUBMITTALS" SECTION <br />SPECIFIC DETAILS. PRODUCTS INCLUDED ARE: <br />1.SOLID WEB WOOD JOISTS (I-JOISTS) <br />2.WOOD TIE DOWN SYSTEMS: CONTINUOUS ROD HOLD-DOWN SYSTEMS, WITH TAKE-UP DEVICES, <br />SHALL BE SPECIFIED. TAKE-UP DEVICES ARE REQUIRED AT EACH FRAMING LEVEL. ADDITIONAL <br />FRAMING MEMBERS SHALL BE PROVIDED PER THE SYSTEM REQUIREMENTS REFER TO DETAILS <br />AND LOADING ON THE STRUCTURAL DRAWINGS. <br />IDENTIFICATIONS: ALL SAWN LUMBER AND PRE-MANUFACTURED WOOD PRODUCTS SHALL BE <br />IDENTIFIED BY THE GRADE MARK OR A CERTIFICATE OF INSPECTION ISSUED BY THE CERTIFYING <br />AGENCY. <br />MATERIALS: <br />1.SAWN LUMBER: CONFORM TO GRADING RULES OF WWPA, WCLIB OR NLGA AND "TABLE OF <br />SAWN LUMBER" FOUND ON THIS SHEET. FINGER JOINTED STUDS ACCEPTABLE AT INTERIOR <br />WALLS ONLY. <br />2.WOOD STRUCTURAL SHEATHING (PLYWOOD): WOOD APA-RATED STRUCTURAL SHEATHING <br />INCLUDES: ALL VENEER PLYWOOD, ORIENTED STRAND BOARD, WAFERBOARD, <br />PARTICLEBOARD, T1-11 SLIDING, AND COMPOSITES OF VENEER AND WOOD BASED MATERIAL <br />WITH T&G JOINT. ARCHITECT MAY DISALLOW OSB. CONFIRM WITH ARCHITECT. CONFORM TO <br />"CONSTRUCTION AND INDUSTRIAL PLYWOOD" BASED ON PRODUCT STANDARD PS 1-07 BY THE <br />U.S. DEPT OF COMMERCE, AND "PERFORMANCE STANDARD FOR WOOD-BASED <br />STRUCTURAL-USE PANELS" BASED ON PRODUCT PS 2-04 BY THE U.S. DEPT. IF CINNERCE AND <br />"PLYWOOD DESIGN SPECIFICATION" BASED ON APA PDS-04 BY THE AMERICAN PLYWOOD <br />ASSOCIATION. UNLESS NOTED OTHERWISE, SHEATHING SHALL COMPLY WITH THE "TABLE OF <br />SHEATHING" FOUND ON THIS SHEET. <br />3.GLUED LAMINATED TIMBER: CONFORM TO AITC 117-2004 "STANDARD SPECIFICATIONS FOR <br />STRUCTURAL GLUE-LAMINATED TIMBER OF SOFTWOOD SPECIES, MANUFACTURING AND <br />DESIGN" AND ANSI/AITC A190.1 "STRUCTURAL GLUED LAMINATED TIMBER." CAMBER ALL GLUED <br />LAMINATED BEAMS, EXCEPT CANTILEVERED AND CONTINUOUS BEAMS, TO 3000' RADIUS, <br />UNLESS SHOWN OTHERWISE ON PLANS. <br />4.ENGINEERED WOOD PRODUCTS (TrusJoist): THE FOLLOWING MATERIALS ARE BASED ON <br />LUMBER MANUFACTURED BY TrusJoist AND WERE USED FOR THE DESIGN AS SHOWN ON PLANS. <br />ALTERNATE PRODUCTS BY OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THEY <br />HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER LOAD AND STIFFNESS <br />PROPERTIES AND ARE REVIEWED AND APPROVED BY THE EOR. A HUD MATERIAL RELEASE <br />FORM IS REQUIRED FORE ALL MANUFACTURED WOOD PRODUCTS LISTED BELOW: <br />a.LAMINATED VENEER LUMBER (LVL): CONFORM TO ICC-ES REPORT NO. ESR-1387 OR CCMC <br />REPORT NO. 08675-R. <br />b.PARALLEL STRAND LUMBER (PSL): CONFORM TO ICC-ES REPORT NO. ESR-1387 OR CCMC <br />REPORT NO. 11161-R <br />c.LAMINATED STRAND LUMBER (LSL): CONFORM TO ICC REPORT NO. ESR-1387 OR CCMC <br />REPORT NO. <br />12627-R. <br />d.PARALLEL CHORD I-JOISTS (DEFERRED SUBMITTAL): CONFORM TO ICC REPORT NO. ESR-1153. <br />THE <br />MANUFACTURER SHALL DESIGN THE JOISTS FOR THE SPANS AND CONDITIONS SHOWN ON <br />THE PLANS. JOISTS SHALL HAVE WOOD CHORDS AND SOLID WOOD WEBS. JOISTS SHALL BE <br />TAPERED OR PARALLELL AS SHOWN ON THE PLANS. <br />5.TIMBER CONNECTORS: SHALL BE "STRONG TIE" BY SIMPSON COMPANY AS SPECIFIED IN THEIR <br />LATEST CATALOG. ALTERNATE CONNECTORS BY OTHER MANUFACTURERS MAY BE <br />SUBSTITUTED PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER <br />LOAD CAPACITIES AND ARE REVIEWED AND APPROVED BY THE SER. PRIOR TO ORDERING. <br />CONNECTORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. WHERE <br />CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN <br />EACH MEMBER. WHERE STRAPS ARE USED AS HOLD-DOWNS, NAIL STRAPS TO WOOD FRAMING <br />JUST PRIOR TO DRYWALL APPLICATION, AS LATE AS POSSIBLE IN THE FRAMING PROCESS TO <br />ALLOW WOOD TO SHRINK AND THE BUILDING TO SETTLE. PREMATURE NAILING OF THE STRAP <br />MAY LEAD TO STRAP BUCKLING AND POTENTIAL FINISH DAMAGE. <br />6. WHERE CONNECTORS ARE IN EXPOSED EXTERIOR APPLICATIONS IN CONTACT WITH <br />PRESERVATIVE TREATED WOOD (PT) OTHER THAN CCA, CONNECTORS SHALL BE EITHER BATCH <br />HOT-DIPPED GALVANIZED (HDG), MECHANICALLY GALVANIZED (ASTM B695, CLASS 55 MINIMUM) <br />STAINLESS STEEL, OR PROVIDED WITH 1.85 OZ/SF OF ZINC GALVANIZING EQUAL TO OR BETTER <br />THAN SIMPSON ZMAX FINISH. <br />7.FASTENERS: (NAILS, BOLTS, SCREWS, ETC) ATTACHING TIMBER CONNECTORS (JOIST HANGERS, <br />POST CAPS, AND BASSES, ETC) TO PT WOOD SHALL HAVE SIMILAR CORROSION RESISTANT <br />PROPERTIES (MATCHING PROTECTIVE TREATMENTS) AS THE PROTECTED CONNECTOR. <br />FASTENERS (NAILS, BOLTS, SCREWS, ETC.) ATTACHING SAWN TIMBER MEMBERS OR <br />SHEATHING (SHEAR WALLS) TO PT WOOD SHALL BE CORROSION RESISTANT; NAILS AND LAG <br />BOLTS SHALL BE EITHER HDG (ASTM A153) OR STAINLESS STEEL. VERIFY THE SUITABILITY OF <br />THE FASTENER PROTECTION/COATING WITH THE WOOD TREATMENT CHEMICAL <br />MANUFACTURER/SUPPLIER. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS <br />AND LAG SCREWS BEARING ON WOOD. <br />8.LAG BOLTS/BOLTS: CONFORM TO ASTM A307 AND CBC SECTION 2304.9 <br />ROOF AND FLOOR PANELS: UNLESS NOTED OTHERWISE ON DRAWINGS, INSTALL ROOF AND FLOOR <br />PANELS WITH LONG DIMENSIONS ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR <br />MORE SPANS. END JOINTS SHALL OCCUR OVER SUPPORTS. HUD MATERIALS BULLETIN 40C GRADE <br />MARKING OF SHEATHING CERTIFICATION IS REQUIRED. <br />NAILING REQUIREMENTS: CONFORM TO CBC SECTION 2304.9 "CONNECTIONS AND FASTENERS." UNLESS <br />NOTED ON PLANS, NAIL PER TABLE 2304.9.1. NAILING FOR ROOF/FLOOR DIAPHRAGMS/SHEARWALLS <br />SHALL BE PER DRAWINGS. NAILS SHALL BE DRIVEN FLUSH AND SHALL NOT FRACTURE THE SURFACE <br />OF SHEATHING. ALTERNATE NAILS MAY BE USED BUT ARE SUBJECT TO REVIEW AND APPROVAL BY THE <br />EOR. SUBSTITUTION OF STAPLES FOR THE NAILING OF RATED SHEATHING IS SUBJECT TO REVIEW BY <br />THE EOR PRIOR TO CONSTRUCTION. <br />STANDARD LIGHT-FRAME CONSTRUCTION: UNLESS NOTED ON THE PLANS, CONSTRUCTION SHALL <br />CONFORM TO CBC SECTION 2308 "CONVENTIONAL LIGHT-FRAME CONSTRUCTION." <br />NAILERS ON STEEL COLUMNS AND BEAMS: WOOD 3X NAILERS ARE GENERALLY REQUIRED ON ALL HSS <br />COLUMNS AND STEEL BEAMS ABUTTING OR EMBEDDED WITHIN WOOD FRAMING. UNLESS NOTED <br />OTHERWISE, ATTACH WITH 5/8" DIAMETER BOLTS OR WELDED STUDS @ 16" ON CENTERS. WOOD <br />NAILERS ON BEAMS SUPPORTING JOIST HANGER SHALL BE FLUSH WITH BEAM FLANGE. <br />MOISTURE CONTENT: WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE <br />CONTENT OF 19% EXCEPT FOR THE PRESSURE-TREATED WOOD SILL PLATE. REFER TO "TESTING & <br />INSPECTIONS" FOR THE VERIFICATION OF THESE LIMITS. THE MAXIMUM MOISTURE CONTENT REQUIRED <br />MAY BE LESS THAN 19% WHEN BASED ON A PARTICULAR CLADDING/INSULATION SYSYTEM. REFER TO <br />THE ARCHITECTURAL DRAWINGS, AND PROJECT SPECIFICATIONS, OR WITH CLADDING INSTALLER FOR <br />MAXIMUM RECOMMENDED MOISTURE CONTENT. <br />SHRINKAGE COMPENSATION FOR MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS: MEP SYSTEMS, <br />INCLUDING DUCTWORK, PIPES, AND OTHER ELEMENTS THAT RUN CONTINUOUSLY BETWEEN LEVELS <br />SHALL BE INSTALLED/DESIGNED IN SUCH A MANNER TO ACCOMMODATE SHRINKAGE IN THE WOOD <br />FRAMING. WOOD SHRINKAGE AMOUNTS WILL VARY DEPENDING ON THE CONSTRUCTION PROCESS AND <br />MATERIALS USED. THE ANTICIPATED SHRINKAGE UNDER TYPICAL CONDITIONS IS EXPECTED TO RANGE <br />BETWEEN 1/8" TO 1/4" PER FLOOR. <br />CLADDING COMPATIBILITY: THE ARCHITECT/OWNER SHALL REVIEW THE CLADDING AND INSULATION <br />SYSTEMS PROPOSED FOR THE PROJECT WITH RESPECT TO THEIR PERFORMANCE OVER WOOD STUDS <br />WITH MOISTER CONTENTS GREATER THAN 19%. EIFS SYSTEMS SHOULD BE AVOIDED ON <br />WOOD-FRAMED PROJECTS DUE TO PROBLEMS WITH MOISTURE PROOFING. <br />PRESERVATIVE TREATMENT (PT): WOOD MATERIALS ARE REQUIRED TO BE "TREATED WOOD" IN <br />ACCORDANCE WITH CBC SECTION 2304.11 "DECAY AND TERMITE PROTECTION" SHALL CONFORM TO <br />THE APPROPRIATE STANDARDS OF THE AMERICAN WOOD PRESERVERS ASSOCIATION (AWPA) FOR <br />SAWN LUMBER, GLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES AND MARINE PILES. FOLLOW <br />AMERICAN LUMBER STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS <br />SHALL BEAR THE APPROPRIATE MARK. FASTENERS OR ANCHORS IN TREATED WOOD SHALL BE OF <br />STAINLESS STEEL OR HOT-DIPPED GALVANIZED OR AS PER CBC 2304.9.5. HUD UM48a <br />PRESSURE-TREATED LUMBER AND PLYWOOD CERTIFICATION IS REQUIRED. <br />MEMBER USE SIZE SPECIES GRADE <br />Stud 2x4, 3x4, 2x6, 3x6 Doug Fir Larch No.2 <br />Sill Plate 2x4, 3x4, 2x6, 3x6 PT Doug Fir Larch No.2 <br />Post 4x4, 4x6, 4x8 Doug Fir Larch No.2 <br />Floor or Roof Joist 2x6 through 2x12 Doug Fir Larch No.2 <br />Beam 4x8 through 4x12 Doug Fir Larch No.2 <br />Beam 6x8 through 6x12 Doug Fir Larch No.1 <br />Post or Timber 6x6, 8x8 Doug Fir Larch No.1 <br />TABLE OF SAWN LUMBER <br />LOCATION THICKNESS SPAN RATING PLYWOOD GRADE EXPOSURE <br />Roof 15/32"32/16 C-D 1 <br />Floor 23/32" T&G 24 OC STUD-I-FLOOR 1 <br />Walls 15/32"32/16 C-D 1 <br />TABLE OF SHEATHING - USE, MINIMUM THICKNESS AND MINIMUM APA RATING <br />TYPE USE WIDTHS E (106) (psi)Fb <br />(psi)Fv (psi) Fc// (psi) <br />LSL Rimboard Rimboard or Stair Stringer 1 1/2"1.3E 1700 400 1835 <br />Timberstrand LSL Header, Beam or Column < 9" <br />depth 3 1/2"1.3E 1700 400 1835 <br />Timberstrand LSL Rimboard, Header or Beam ≥ <br />9" depth 1 3/4" , 3 1/2"1.55E 2325 310 2170 <br />Timberstrand LSL Wall Stud 2x4 & 2x6 1 1/2"1.3E 1700 400 1300 <br />Wall Stud > 2x6 1 1/2"1.5E 2250 400 1950 <br />Microllam LVL Header, Beam 1 3/4"2.0E 2600 285 2510 <br />Parallam PSL Header, Beam 3 1/2" , 5 1/4", 7"2.0E 2900 290 2900 <br />Parallam PSL Column 3 1/2" , 5 1/4", 7"1.8E 2400 190 2500 <br />TABLE OF ENGINEERED WOOD REQUIREMENTS <br />TABLE OF GLULAM AND GRADE <br />S-0.13 <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br />Wood structural panels, combination subfloor underlayment to framing <br />35. 3/4" and less 8d common (2 1/2" x 0.131"); or <br />6d deformed (2" x 0.113")6 12 <br />36. 7/8" - 1"8d common (2 1/2" x 0.131"); or <br />8d deformed (2 1/2" x 0.131")6 12 <br />37. 1 1/8" - 1 1/4"10d common (3" x 0.148"); or <br />8d deformed (2 1/2" x 0.131")6 12 <br />ROOF <br />1. Blocking between ceiling joists rafters or trusses <br />to top plate or framing below <br />3-8d common (2 1/2" X 0.131"); or <br />3-10d box (3" X 0.128"); or <br />3-3" 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown <br />Each end, toenail <br />Blocking between rafters or truss not at the wall top <br />plate, to rafter or truss <br />2-8d common (2 1/2" X 0.131") <br />2-3" x 0.131" nails <br />2-3" 14 gage staples <br />Each end, toenail <br />2-16d common (3 1/2" x 0.162" <br />3-3" x 0.131" nails <br />3-3" 14 gage staples <br />End nail <br />Flat blocking to truss and web filler <br />16d common (3 1/2" x 0.162") @ 6" <br />o.c. <br />3" x 0.131" nails @ 6" o.c. <br />3" x 14 gage staples @ 6" o.c. <br />Face nail <br />2. Ceiling joists to top plate <br />3-8d common (2 1/2" x 0.131"); or <br />3-10d box (3" x 0.128"); or <br />3-3" x 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown <br />Each joist, toenail <br />3. Ceiling joist not attached to parallel rafter, laps <br />over partitions (no thrust) (see Section 2308.7.3.1, <br />Table 2308.7.3.1) <br />3-16d common (3 1/2" x 0.162"); or <br />4-10d box (3" X 0.128"); or <br />4-3" x 0.131" nails; or <br />4-3" 14 gage staples, 7/16" crown <br />Face nail <br />4. Ceiling joist attached to parallel rafter (heel joint) <br />(see Section 2308.7.3.1, Table 2308.7.3.1)Per Table 2308.7.3.1 Face nail <br />5. Collar tie to rafter <br />3-10d common (3 1/2" x 0.148"); or <br />4-10d box (3" X 0.128"); or <br />4-3" x 0.131" nails; or <br />4-3" 14 gage staples, 7/16" crown <br />Face nail <br />6. Rafter or roof truss to itop plate (See Section <br />2308.7.5, Table 2308.7.5) <br />3-10d common (3 1/2" x 0.148"); or <br />3-16d box (3 1/2" x 0.135"); or <br />4-10d box (3" x 0.128"); or <br />4-3" x 0.131" nails; or <br />4-3" 14 gage staples, 7/16" crown <br />Toenailc <br />7. Roof rafters to ridge valley or hip rafters; or roof <br />rafter to 2-inch ridge beam <br />2-16d common (3 1/2" x 0.162"); or <br />3-10d box (3 1/2" x 0.128"); or <br />3-3" x 0.131 nails; or <br />3-3" 14 gage staples, 7/16" crown; <br />or <br />End nail <br />3-10d common (3 1/2" x 0.148"); or <br />4-16d box (3 1/2" x 0.135"); or <br />4-10d box (3" x 0.128"); or <br />4-3" x 0.131" nails; or <br />4-3" 14 gage staples, 7/16" crown <br />Toenail <br />WALL <br />8. Stud to stud (not at braced wall panels) <br />16d common (3 1/2" x 0.162");24" o.c. face nail <br />10d box (3" x 0.128"); or <br />3" x 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown <br />16" o.c. face nail <br />9. Stud to stud and abutting studs at intersecting <br />wall corners (at braced wall panels) <br />16d common (3 1/2" x 0.162"); or 16" o.c. face nail <br />16d box (3 1/2" x 0.135"); or 12" o.c. face nail <br />3" x 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown 12" o.c. face nail <br />10. Built-up header (2" to 2" header) <br />16d common (3 1/2" x 0.162"); or 16" o.c. each <br />edge, face nail <br />16d box (3 1/2" x 0.135")12" o.c. each <br />edge, face nail <br />11. Continuous header to stud 4-8d common (2 1/2" x 0.131"); or <br />4-10d box (3" x 0.128")Toenail <br />12. Top plate to top plate <br />16d common (3 1/2" x 0.162"); or 16" o.c. face nail <br />10d box (3" x 0.128"); or <br />3" x 0.131" nails; or <br />3" 14 gage staples, 7/16" crown <br />12" o.c. face nail <br />13. Top plate to top plate, at end joints <br />8-16d common (3 1/2" x 0.162"); or <br />12-10d box (3 1/2" x 0.128"); or <br />12-3" x 0.131" nails; or <br />12-3" 14 gage staples, 7/16" crown <br />Each side of end <br />joint, face nail <br />(minimum 24" lap <br />splice length each <br />side of end joint) <br />14. Bottom plate to joist, rim joist, band joist or <br />blocking (not at braced wall panels) <br />16d common (3 1/2" x 0.162"); or 16" o.c. face nail <br />16d box (3 1/2" x 0.135"); or <br />3" x 0.131" nails; or <br />3" 14 gage staples, 7/16" crown <br />12" o.c. face nail <br />15. Bottom plate to joist, rim joist, band joist or <br />blocking at braced wall panels <br />2-16d common (3 1/2" x 0.162"); or <br />3-16d box (3 1/2" x 0.135"); or <br />4-3" x 0.131" nails; or <br />4-3" 14 gage staples, 7/16" crown <br />16" o.c. face nail <br />16. Stud to top or bottom plate <br />4-8d common (2 1/2" x 0.131"); or <br />4-10d box (3" x 0.128"); or <br />4-3" x 0.131" nails; or <br />4-3" 14 gage staples, 7/16" crown <br />or <br />Toenail <br />2-16d common (3 1/2" x 0.162"); or <br />3-10d box (3 1/2" x 0.128"); or <br />3-3" x 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown <br />End nail <br />17. Top plates, laps at corners and intersections <br />2-16d common (3 1/2" x 0.131"); or <br />3-10d box (3 1/2" x 0.128"); or <br />3-3" x 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown <br />Face nail <br />18. 1" brace to each stud and plate <br />2-8d common (2 1/2" x 0.131"); or <br />2-10d box (3 1/2" x 0.128"); or <br />2-3" x 0.131" nails; or <br />2-3" 14 gage staples, 7/16" crown <br />Face nail <br />19. 1" x 6" sheathing to each bearing 2-8d common (2 1/2" x 0.131"); or <br />2-10d box (3 1/2" x 0.128"); or Face nail <br />20. 1" x 8" and wider sheathing to each bearing 3-8d common (2 1/2" x 0.131"); or <br />3-10d box (3 1/2" x 0.128"); or Face nail <br />FLOOR <br />21. Joist to sill, top plate, or girder <br />3-8d common (2 1/2" x 0.131"); or <br />3-10d box (3 1/2" x 0.128"); or <br />3-3" x 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown <br />Toenail <br />22. Rim joist, band joist, or blocking to top <br />plate, sill or other framing below <br />8d common (2 1/2" x 0.131"); or <br />10d box (3" x 0.128"); or <br />3-3" x 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown <br />6" o.c., toenail <br />23. 1" x 6" subfloor or less to each joist 2-8d common (2 1/2" x 0.131"); or <br />2-10d box (3" x 0.128")Face nail <br />24. 2" subfloor to joist or girder 2-16d common (3 1/2" x 0.162")Face nail <br />25. 2" planks (plank & beam - floor & roof)2-16d common (3 1/2" x 0.162")Each bearing, face nail <br />26. Built-up girders and beams, 2" lumber <br />layers <br />20d common (4" x 0.192") <br />32" o.c., face nail at top and <br />bottom staggered on opposite <br />sides <br />10d box (3" x 0.128"); or <br />3" x 0.131" nails; or <br />3" 14 gage staples, 7/16" crown <br />24" o.c., face nail at top and <br />bottom staggered on opposite <br />sides <br />And: <br />2-20d common (4" x 0.192); or <br />3-10d box (3" x 0.128"); or <br />3-3" x 0.131" nails; or <br />3-3" 14 gage staples, 7/16" crown <br />Ends and at each splice, face <br />nail <br />27. Ledger strip supporting joists or rafters <br />3-16d common (3 1/2" x 0.162"); or <br />4-10d box (3" x 0.128"); or <br />4-3" x 0.131" nails; or <br />4-3" 14 gage staples, 7/16" crown <br />Each joist or rafter, face nail <br />28. Joist to band joist or rim joist <br />3-16d common (3 1/2" x 0.162"); or <br />4-10d box (3" x 0.128"); or <br />4-3" x 0.131" nails; or <br />4-3" 14 gage staples, 7/16" crown <br />End nail <br />29. Bridging or blocking to joist, rafter or <br />truss <br />2-8d common (2 1/2" x 0.131"); or <br />2-10d box (3" x 0.128"); or <br />2-3" x 0.131" nails; or <br />2-3" 14 gage staples, 7/16" crown <br />Each end, toenail <br />Wood structural panels (WSP), subfloor, roof and interior wall sheathing to framing and particle wall sheathing to <br />framinga <br />Edges <br />(inches) <br />Intermediate <br />supports <br />(inches) <br />30. 3/8" - 1/2" <br />6d common or deformed (2" x 0.113") <br />(subfloor and wall)6 12 <br />8d common or deformed (2 1/2" x 0.131") <br />(roof) or RSRS-01 (2 3/8" x 0.113") nail <br />(roof)d <br />6 12 <br />2 3/8" x 0.113" nail (subfloor and wall)6 12 <br />1 3/4" 16 gage staple, 7/16" crown (subfloor <br />and wall)4 8 <br />2 3/8" x 0.113" nail (roof)4 8 <br />1 3/4" 16 gage staple, 7/16" crown (roof)3 6 <br />31. 19/32" - 3/4" <br />8d common (2 1/2" x 0.131"); or <br />6d deformed (2" x 0.113") (subfloor and <br />wall) <br />6 12 <br />8d common or deformed (2 1/2" x 0.131") <br />(roof) or RSRS-01 (2 3/8" x 0.113") nail <br />(roof)d <br />6 12 <br />2 3/8" x 0.113" nail; or <br />2" 16 gage staple, 7/16" crown 4 8 <br />32. 7/8" - 1/4"10d common (3" x 0.148"); or <br />8d deformed (2 1/2" x 0.131")6 12 <br />Other Exterior Wall Sheathing <br />33. 1/2" fiberboard sheathingb <br />1 1/2" galvanized roofing nail <br />(7/16" head diameter); or <br />1 1/4" 16 gage staple with 7/16" or <br />1" crown <br />3 6 <br />34. 19/32" - 3/4" <br />1 3/4" galvanized roofing nail <br />(7/16" head diameter); or <br />1 1/2" 16 gage staple with 7/16" or <br />1" crown <br />3 6 <br />Interior paneling <br />40. 1/4"4d casing (1 1/2" x 0.080"; or <br />4d finish (1 1/2" x 0.072")6 12 <br />41. 3/8"6d casing (2" x 0.099"; or <br />6d finish (Panel supports at 24 inches)6 12 <br />Panel siding to framing <br />38. 1/2" or less <br />6d corrosion-resistant siding <br />(1 7/8" x 0.106"); or <br />6d corrosion-resistant casing (2" x 0.099") <br />6 12 <br />39. 5/8" <br />8d corrosion-resistant siding <br />(2 3/8" x 0.128"); or <br />8d corrosion-resistant casing <br />(2 1/2" x 0.113") <br />6 12 <br />FOR SI: 1 INCH = 25.4 mm. <br />a. NAILS SPACED AT 6 INCHES AT INTERMEDIATE SUPPORTS WHERE SPANS ARE48 INCHES OR MORE. FOR <br />NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO <br />SECTION 2305. NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX OR CASING. <br />b. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE <br />SUPPORTS FOR NONSTRUCTURAL APPLICATIONS. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH <br />AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED). <br />c. WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS <br />SCHEDULE AND THE CEILING JOIST IS FASTENED TO THE TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE, <br />THE NUMBER OF TOENAILS IN THE RAFTER SHALL BE PERMITTED TO BE REDUCED TO ONE NAIL. <br />d. RSRS-01 IS A ROOF SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667 <br />NAILING SCHEDULE