My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6 E Hutton Center Dr #A-REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Hutton Center Dr
>
6 E Hutton Center Dr Unit# A
>
6 E Hutton Center Dr #A-REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:22 AM
Creation date
2/24/2026 5:00:36 AM
Metadata
Fields
Template:
Plan
Permit Number
20184271
101121211
Full Address
6 E Hutton Center Dr Unit# A
Street Number
6
Street Direction
E
Street Name
Hutton Center
Street Suffix
Dr
Unit Number
A
Document Relationships
101121211 - Permit
(Permit - Plan)
Path:
\Building\Permits\H\Hutton Center Dr\6 E Hutton Center Dr Unit# A
20184271 - Permit
(Permit - Plan)
Path:
\Building\Permits\H\Hutton Center Dr\6 E Hutton Center Dr Unit# A
Polygon
ID:
1
Creator:
Import Agent
Created:
2/24/2026 5:00 AM
Modified:
2/23/2026 1:39 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONTRACTOR <br />SHEET DESCRIPTION: <br />LEVEL 01 FLOOR PLAN <br />DRAWN DATE <br />DRAWN BY <br />REVIEWED BY <br />REVISIONS <br />REV DESCRIPTION DATE <br />SHEET INDEX <br />UTILITY : SANTA ANA <br />PROJECT INFORMATION <br />AHJ : LOS ANGELES <br />ADDRESS : 6 HUTTON CENTRE <br />DRIVE, UNIT A, SANTA ANA, CA <br />92707 <br />NAME : WESTSIDE CONTRACTORS <br />APN : ---- <br />CHARGIE LLC <br />3947 Landmark St, <br />Culver City, CA 90232 <br />(310) 307-5166 <br />JOHNNY HUSTON <br />LIC: #1086808 <br />SYSTEM INFORMATION: <br />(8)EVO CHARGE <br />CHARGING STATIONS <br />SIGNATURE WITH SEAL <br />ENLARGED PLAN: <br />NOTE: THE HIGH FORWARD REACH SHALL <br />BE 48 INCHES (1219.2 MM) MAXIMUM AND <br />THE LOW FORWARD REACH SHALL BE 15 <br />INCHES (381 MM) MINIMUM ABOVE THE <br />FINISH FLOOR OR GROUND. THE <br />CONTRACTOR NEED TO PROVIDE DURING <br />THE INSTALLATION <br />REACH RANGES: <br />SC 0"EV1 - EV4 4 CHARGERS <br />10'-3" <br />EV-03 <br />02.05.2025 <br />DOTSON <br />VG <br />SCALE: 1" = 10'-0" <br />STAIR <br />RES. <br />STAIR <br />R <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />C C C C C C C C C C C C C C C <br />NO <br />PARK M M <br />OFFICEELEC. <br />R <br />R <br />R <br />C <br />C <br />C <br />C <br />C <br />C <br />23'-0" <br />8' <br />- <br />0 <br />" <br />17'-0" <br />19'-0" <br />9' <br />- <br />0 <br />" <br />8'-0" <br />17 <br />' <br />- <br />0 <br />" <br />23 <br />' <br />- <br />0 <br />" <br />EV EV EV EV EV EV EV <br />EV <br /> <br />C <br />H <br />A <br />R <br />G <br />I <br />N <br />G <br />ON <br />L <br />Y <br />EV <br /> <br />C <br />H <br />A <br />R <br />G <br />I <br />N <br />G <br />ON <br />L <br />Y <br />NO <br /> <br />P <br />A <br />R <br />K <br />I <br />N <br />G <br />RES. <br />RES. <br />RES. <br />R <br />R <br />R <br />R <br />R <br />RES. <br />RES. <br />RES. <br />RES. <br />RES. <br />RES. <br />C <br />C <br />C <br />C <br />C <br />STORAGE <br />RES. <br />(E) CHARGEPOINT DUAL <br />PORT CHARGERS <br />ACCESSIBLE PATH <br />OF TRAVEL TO <br />FRONT ENTRANCES <br />AS PER 11B-812.5 <br />VAHE GULAGIAN <br />02/10/2025 <br />NOTE: THE WALL MOUNTED UNITS ARE POSITIVELY ATTACHED TO <br />THE STRUCTURE AS REQUIRED BY ASCE 7-16 13.1.4 <br />NOTE: WALL COLLARS ARE USED AS PHYSICAL BARRIERS <br />FOR PROTECTING WALL MOUNTED CHARGER'S AGAINST <br />ACCIDENTAL DAMAGE. <br />EV CHARGING ONLY MARKING <br />ISA MARKING - ACCESSIBLE <br />SPACE TO BE STRIPED <br />SINGLE CHARGIE EV STATION - <br />WALL MOUNTED WITH COLLAR <br />PROTECTION <br />SINGLE CHARGIE EV STATION - <br />COLUMN MOUNTED WITH <br />BOLLARD PROTECTION <br />EXISISTING CHARGEPOINT EV <br />STATION - DUAL PORT <br />(E) BIKE ROOM AT GROUND LEVEL <br />(E) 600A MAIN SERVICE PANEL 120/208V, 3PH, 4W <br />(E) PANEL "EV" 200A, 120/208V, 3PH, 4W <br />(N) EVOCHARGE LEVEL 2 CHARGER, <br />WALL MOUNTED WITH COLLAR <br />(N) EVOCHARGE LEVEL 2 CHARGER, <br />COLUMN MOUNTED WITH BOLLARD <br />9' <br />- <br />0 <br />" <br />9' <br />- <br />0 <br />" <br />RE <br />S <br />. <br />EV CHARGING <br />ONLY <br />EV CHARGING <br />ONLYNO PARKING <br />SHEET NOTES: <br />1 ATTACH LABEL 01, 02, AND 03 TO <br />THE FRONT OF (E)PANEL "EV" <br />2 ATTACH LABEL 03 ADJACENT TO <br />BREAKER ASSOCIATED WITH (E)PANEL <br />"EV" <br /> <br /> <br /> <br />DETAILED VIEW 1. <br />MARKINGS STATING "EV CHARGING ONLY" IN LETTERS <br />12 INCHES HIGH. CENTERED IN THE STALL, WITH TEXT <br />ON THE SPACE'S EDGE AS PER CBC 11B-812.9 <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY - 36" X 36" <br />"NO PARKING" PAINTED WITHIN THE ACCESS AISLE IN <br />WHITE LETTERS, 12 INCHES HIGH. VISIBLE FROM THE <br />ADJACENT VEHICULAR WAY <br />ACCESS AISLE MARKED IN BLUE PAINTED BORDERLINE <br />AROUND THEIR PERIMETER. HATCHING 36" ON CENTER <br />IN BLUE. <br />VAN ACCESSIBLE SPACE = 9'-0" WITH AN 8'-0" WIDE <br />ACCESS AISLE AS PER CBC 1109A.8.6. <br />SPACE MEASUREMENTS ARE TO BE MEASURED FROM <br />THE MIDPOINT OF THE LINES. ALL LINES ARE TO BE <br />STRIPED WITH A MINIMUM THICKNESS OF 4". <br />STANDARD ACCESSIBLE SPACE = 9'-0" <br />WITH AN 8'-0" WIDE ACCESS AISLE. <br />ENTRANCE <br />EXIT <br />EXIT <br />9'-0" <br />18'-0" <br />18'-0" <br />8'-0" <br />9'-0" <br />5'-0" <br />6 HUTTON CENTRE DR, SANTA ANA, CA, 92707 <br />STANDARD ACCESSIBLE PARKING <br />SIGNAGE TO BE USED: <br />VAN ACCESSIBLE PARKING <br />SIGNAGE TO BE USED: <br />ACCESSIBILITY SIGNAGE AND SURFACE MARKINGS REQUIRED ON <br />ACCESSIBLE EV SPACES AS PER CBC 1109A.8.8. THESE SIGNS WILL BE <br />SECURED TO THE WALL A MINIMUM OF 60 INCHES FROM THE PARKING <br />SURFACE TO THE BOTTOM EDGE OF THE SIGN. <br />ACCESSIBLE SPACE SIGNAGE WALL MOUNTED.
The URL can be used to link to this page
Your browser does not support the video tag.