Laserfiche WebLink
CONTRACTOR <br />SHEET DESCRIPTION: <br />LEVEL 01 FLOOR PLAN <br />DRAWN DATE 21.05.2024 <br />DRAWN BY CAMERON <br />REVIEWED BY SHELDON <br />REVISIONS <br />REV DESCRIPTION DATE <br />SHEET INDEX <br />UTILITY : SANTA ANA <br />PROJECT INFORMATION <br />AHJ : LOS ANGELES <br />ADDRESS : 6 HUTTON CENTRE <br />DRIVE, UNIT A, SANTA ANA, CA <br />92707 <br />NAME : WESTSIDE CONTRACTORS <br />APN : ---- <br />CHARGIE LLC <br />3947 Landmark St, <br />Culver City, CA 90232 <br />(310) 307-5166 <br />JOHNNY HUSTON <br />LIC: #1086808 <br />SYSTEM INFORMATION: <br />(8)EVO CHARGE <br />CHARGING STATIONS <br />SIGNATURE WITH SEAL <br />ENLARGED PLAN: <br />NOTE: THE HIGH FORWARD REACH SHALL <br />BE 48 INCHES (1219.2 MM) MAXIMUM AND <br />THE LOW FORWARD REACH SHALL BE 15 <br />INCHES (381 MM) MINIMUM ABOVE THE <br />FINISH FLOOR OR GROUND. THE <br />CONTRACTOR NEED TO PROVIDE DURING <br />THE INSTALLATION <br />REACH RANGES: <br />LEGEND: <br />MSP - EV <br />PULL <br />PNL - EV <br />N <br />G <br />(N) TRANSFORMER <br />(N)TRANSFORMER <br />G <br />M <br />CHARGIE <br />ELECTRIC VEHICLE <br />CHARGE STATION <br />HIGH POWER <br />POWER <br />CHARGING <br />POWER FAULT <br />CHARGING FAULT <br />CHARGIE <br />ELECTRIC VEHICLE <br />CHARGE STATION <br />HIGH POWER <br />POWER <br />CHARGING <br />POWER FAULT <br />CHARGING FAULT <br />- SAFETY BOLLARD <br />- CONDUIT <br />- PARKING SIGN <br />- MAIN SERVICE PANEL (EV) <br />- PULL SECTION <br />- EV PANEL <br />- EV TRANSFORMER <br />- DISCONNECT <br />- METER <br />- GAS METER <br />- EV CHARGING STALL <br />- EV SINGLE PORT <br /> WALL MOUNTED <br />- EV SINGLE PORT <br /> PEDESTAL MOUNTED <br />- 2 EV SINGLE PORT <br /> PEDESTAL MOUNTED <br />- ADA STALL <br />ELECTRIC <br />VEHICLE <br />CHARGING <br />STATION <br />PARKING ONLY <br />WHILE CHARGING <br />EV PANEL <br />SAFETY BOLLARD <br />SAFETY BOLLARD: <br />PARKING SIGN <br />SCALE: 3/16" = 1'-0" <br />LEVEL 1 <br /> CHARGER TOATAL CHARGERS <br />EV1 - EV4 4 CHARGERS <br />120121 122 123 124 125 126 127 128 129 130 131 202 203 204 205 206 207 1B <br />1D 1B <br />1D <br />208 <br />209 <br />210 <br />211 <br />212 <br />213 <br />214 <br />215 <br />216 <br />217 <br />218 <br />219 <br />220 <br />221 <br />222 <br />223 <br />224 <br />225 <br />226 <br />227 <br />228 <br />229 <br />230 <br />231 <br />232 <br />233 <br />234 <br />235 <br />236 <br />237 <br />238 <br />239 <br />240 <br />241 <br />242 <br />243 <br />244 <br />245 <br />246 <br />247 <br />248 <br />249 <br />250 <br />251 <br />252 <br />132 <br />133 <br />134 <br />135 <br />136 <br />137 <br />138 <br />139 <br />140 <br />141 <br />142 <br />143 <br />144 <br />145 <br />146 <br />147 <br />148 <br />149 <br />150 <br />151 <br />152 <br />153 <br />154 <br />155 <br />156 <br />157 <br />158 <br />159 <br />160 <br />161 <br />162 <br />201 <br />200 <br />199 <br />198 <br />197 <br />196 <br />195 <br />194 <br />253 <br />193 <br />192 <br />191 <br />190 <br />189 <br />188 <br />187 <br />186 <br />185 <br />184 <br />183 <br />182 <br />181 <br />180 <br />179 <br />178 <br />177 <br />176 <br />175 <br />174 <br />173 <br />172 <br />171 <br />170 <br />169 <br />164 163165 166 167 168 <br />119 <br />118 <br />117 <br />116 <br />115 <br />114 <br />113 <br />112 <br />111 <br />110 <br />109 <br />108 <br />107 <br />106 <br />105 <br />104 <br />103 <br />102 <br />101 <br />100 <br />99 <br />98 <br />97 <br />96 <br />95 <br />94 <br />93 <br />92 <br />91 <br />908988 8786878483828180 7978777675 <br />1B <br />71 # <br />1B <br />WALKWAY <br />ST <br />A <br />R <br />I <br />R <br />W <br />E <br />L <br />L <br />/ <br />1 <br />D <br />ST <br />A <br />R <br />I <br />R <br />W <br />E <br />L <br />L <br />/ <br />1 <br />C <br />ST <br />A <br />R <br />I <br />R <br />W <br />E <br />L <br />L <br />/ <br />1 <br />B <br />10'-3" <br />STAIRWAY <br /> <br /> <br /> <br />NOTE: WALL COLLARS ARE USED AS PHYSICAL BARRIERS <br />FOR PROTECTING WALL MOUNTED CHARGER'S AGAINST <br />ACCIDENTAL DAMAGE. <br />NOTE:THE ELECTRIC VEHICLE CHARGING STATIONS WILL <br />NOT BE USED AS COMMON CHARGING AREA'S AS PER <br />11B-228.3.2 <br />NOTE: THE ELECTRIC VEHICLE CHARGING STATIONS ARE <br />DESIGNATED FOR SPECIFIC TENANT US E ONLY. <br />NOTE: PLEASE VERIFY EV CHARGER LOCATIONS IN FIELD. <br />NOTE: THE WALL MOUNTED UNITS ARE POSITIVELY ATTACHED TO <br />THE STRUCTURE AS REQUIRED BY ASCE 7-16 13.1.4 <br />HUTTON CENTRE DR <br />(E) 600A MAIN SERVICE PANEL <br />120/208V, 3PH 4W <br />(E) "PANEL EV" 200A <br /> 120/208V, 3PH 4W <br />(E) BIKE ROOM AT GROUND <br />FLOOR <br />(N) EVO CHARGE, LEVEL 2 CHARGER <br />PARKING GARAGE: 8 CHARGER'S <br />PARKING GARAGE ENTRANCE <br />SCALE: NTS <br />SHEET NOTES: <br />1 ATTACH LABEL 01, 02, AND 03 TO <br />THE FRONT OF (E)PANEL "EV" <br />2 ATTACH LABEL 03 ADJACENT TO <br />BREAKER ASSOCIATED WITH (E)PANEL <br />"EV" <br />1 <br />2 <br />EV-03 <br />6 E Hutton Center Dr <br />#A12/9/2024