Laserfiche WebLink
CONTRACTOR <br />SHEET DESCRIPTION: <br />PANEL SCHEDULE <br />DRAWN DATE 21.05.2024 <br />DRAWN BY CAMERON <br />REVIEWED BY SHELDON <br />REVISIONS <br />REV DESCRIPTION DATE <br />SHEET INDEX <br />UTILITY : SANTA ANA <br />PROJECT INFORMATION <br />AHJ : LOS ANGELES <br />ADDRESS : 6 HUTTON CENTRE <br />DRIVE, UNIT A, SANTA ANA, CA <br />92707 <br />NAME : WESTSIDE CONTRACTORS <br />APN : ---- <br />SYSTEM INFORMATION: <br />(8)EVO CHARGE <br />CHARGING STATIONS <br />SIGNATURE WITH SEAL <br />TOTAL FEEDER AMPS: 23.71A <br />EV CHARGING LOAD PART OF AUTOMATIC LOAD MANAGEMENT SYSTEM <br />MAXLOAD OF LOAD MAXIMUM SYSTEM IS 23.71A PER NEC 625.41-625.43 <br />NOTE: AS PER 210.4(B) ALL EV(S) BREAKER/2 POLE WILL DISCONNECT <br />SIMULTANEOUSLY. <br />210.0(B): DISCONNECTING MEANS ON MULTI-BRANCH CIRCUITS: EACH <br />MULTIWIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS THAT <br />WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT <br />THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES. <br />EV CHARGING LOAD PART OF AUTOMATIC LOAD MANAGEMENT SYSTEM. MAX LOAD OF LOAD <br />MANAGEMENT SYSTEM IS 23.71A PER NEC 625.42 <br />CHARGIE LOAD MANAGEMENT IS CERTIFIED ENERGY MANAGEMENT EQUIPMENT. <br />CHARGIE LLC <br />3947 Landmark St, <br />Culver City, CA 90232 <br />(310) 307-5166 <br />JOHNNY HUSTON <br />LIC: #1086808 <br />(E) PANEL EV: 200A-120/208V-THREE PHASE-4W <br />CIRCUIT NAME POLES OCPD <br />RATING <br />EV <br />CHARGER'S <br />CONNECTED <br />LOAD A B C C B A CONNECTED <br />LOAD <br />EV <br />CHARGER'S POLES OCPD <br />RATING NAME CIRCUIT <br />1 LEVEL 2 EV CHARGER 1,2 2 40A 2 6,656 <br />3,328 3,328 <br />6,656 2 2 40A LEVEL 2 EV CHARGER 5,6 2 <br />3 3,328 3,328 4 <br />5 LEVEL 2 EV CHARGER 3,4 2 40A 2 6,656 <br />3,328 3,328 <br />6,656 2 2 40A LEVEL 2 EV CHARGER 7,8 6 <br />7 3,328 3,328 8 <br />9 GATEWAY 1 20A 180 180 10 <br />(LOAD MANAGED) CONNECTED LOAD (VA) 6,656 3,508 3,328 3,328 3,328 6,656 <br />DEMAND LOAD (VA) 8,320 4,340 4,160 4,160 4,160 8,320 <br />TOTAL CONNECTED (VA)26,804 <br />TOTAL DEMAND (VA) :33,460 <br />TOTAL DEMAND (A)92.88 <br />NOTE: CHARGER SETTING WILL BE SET AT 32A PER 40A <br />BRANCH CIRCUIT. <br />NOTE: WALL COLLARS ARE USED AS PHYSICAL BARRIERS <br />FOR PROTECTING WALL MOUNTED CHARGER'S AGAINST <br />ACCIDENTAL DAMAGE. <br />NOTE: THE WALL MOUNTED UNITS ARE POSITIVELY ATTACHED TO <br />THE STRUCTURE AS REQUIRED BY ASCE 7-16 13.1.4 <br />NOTE: THE ELECTRIC VEHICLE CHARGING STATIONS ARE <br />DESIGNATED FOR SPECIFIC TENANT US E ONLY. <br />NOTE:THE ELECTRIC VEHICLE CHARGING STATIONS WILL <br />NOT BE USED AS COMMON CHARGING AREA'S AS PER <br />11B-228.3.2 <br />EV CHARGING LOAD PART OF AUTOMATIC LOAD MANAGEMENT SYSTEM. MAX <br />LOAD OF LOAD MANAGEMENT SYSTEM IS 92.88A PER NEC 625.42 <br />LOAD MANAGEMENT IS CERTIFIED BY CHARGIE ENERGY MANAGEMENT <br />EQUIPMENT. <br />TOTAL FEEDER AMPS: 92.88A <br />EV CHARGING LOAD PART OF AUTOMATIC LOAD MANAGEMENT SYSTEM <br />MAXLOAD OF LOAD MAXIMUM SYSTEM IS 92.88A PER NEC 625.41-625.43 <br />EV-04 <br />6 E Hutton Center Dr <br />#A12/9/2024