Laserfiche WebLink
NOTE: <br />1. FOR PENETRATIONS BELOW FLOOR LINE, PVC OR STEEL <br /> SLEEVE EXTENDS TO BE FLUSH WITH FACE OF MASONRY, <br /> EACH SIDE. <br />2. PVC OR STEEL WALL SLEEVE SHALL BE PROVIDED BY <br /> MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR <br /> SHALL COORDINATE TOTAL NUMBER OF COLLARS REQUIRED, <br /> SIZE OF COLLARS, AND LOCATIONS WITH CONCRETE <br /> CONTRACTOR. <br />3. FIELD LAYOUT TO BE PROVIDED BY THE MECHANICAL <br /> CONTRACTOR <br />PVC OR STEEL WALL SLEEVE <br />URETHANE BASED <br />SEALANT (TYP.) <br />MASONRY OR <br />CONCRETE WALL <br />INSULATED METAL <br />PANEL <br />2 PART, 98% CLOSED CELL URETHANE <br />FOAM INSERTED BETWEEN FOAM <br />DAMS VIA MIXING NOZZLE PROVIDED <br />WITH CONDUIT SEAL KIT <br />CONDUIT BODY REQUIRED FOR <br />ALL TEMPERATURE DIFFERENCES <br />OF 10°F OR GREATER <br />LIGHT FIXTURE OR <br />JUNCTION BOX <br />4" FABLOK TO FASTEN LIGHT <br />OR JUNCTION BOX <br />PVC CONDUIT FOR THERMAL <br />ISOLATION <br />SEAL AROUND END OF <br />CONDUIT WITH URETHANE <br />BASED SEALANT <br />URETHANE BASED <br />SEALANT ON TOP, <br />BOTTOM, AND SIDES <br />INTERIOR / COLD SIDEEXTERIOR / WARM SIDE <br />NOTES: <br />1. FOAMING & SEALING TO PROVIDE VAPOR BARRIER CONTINUITY <br /> OF INSULATED WALL PANEL BY CONTRACTOR INSTALLING <br /> CONDUIT. <br />2. DRILL METAL SKIN OF PANEL TIGHT TO CONDUIT DIAMETER. <br />URETHANE BASED SEALANT <br />(TYP.) <br />FOAM DAM AS PROVIDED WITH <br />CONDUIT SEALING KIT PACKED <br />AROUND WIRES <br />WARM SIDECOLD SIDE <br />INSULATED METAL <br />WALL PANEL <br />CONDUIT INSULATION <br />1/2" (MIN.) FOAM-IN-PLACE <br />URETHANE OR DOW CORNING <br />#3-6548 SILICONE RTV <br />RESILIENT FOAM PENETRATION <br />SEALANT 1/2" FOAM-IN-PLACE <br />URETHANE (TYPICAL) <br />URETHANE BASED <br />SEALANT (TYP.) <br />NOTES: <br />1. PENETRATION AND CONDUIT INSULATION BY CONTRACTOR <br /> INSTALLING CONDUIT. <br />2. FOAMING AND SEALING TO PROVIDE VAPOR BARRIER <br /> CONTINUITY OF PANEL BY PANEL INSTALLER. <br />3. TRIM METAL SKIN OF PANEL TO 1" LARGER THAN CONDUIT <br />DIAMETER. <br />SEAL ENDS OF INSUL W/ VAPOR <br />BARRIER MASTIC REINFORCED <br />W/ OPEN MESH GLASS FABRIC <br />(TYPICAL) <br />30" <br />MIN <br />30" <br />MIN <br />3" <br />CONDUIT OUTLET BODY TO <br />MATCH CONDUIT TYPE <br />CONDUIT <br />FOAM DAM FORMED AROUND <br />WIRING AS PROVIDED WITH <br />CONDUIT SEAL KIT <br />2 PART, 98% CLOSED CELL <br />URETHANE FOAM INSERTED <br />BETWEEN FOAM DAMS VIA <br />MIXING NOZZLE PROVIDED WITH <br />CONDUIT SEAL KIT <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />I-002-1 <br />RBF <br />EJE <br />04/02/2024 <br />WALL <br />PENETRATION <br />DETAILS <br />2350 PULLMAN ASPIRE BAKERY <br />2350 PULLMAN STREET <br />SANTA ANA, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />PULLMAN,LLC <br />NO SCALEI-002-1 <br />A <br />NON INSULATED PIPE PENETRATION <br />THRU MASONRY / CONCRETE WALL <br />DETAIL <br />NO SCALEI-002-1 <br />B <br />CONDUIT THRU IMP DETAIL FOR <br />SURFACE MOUNTED EQUIPMENT <br />1 1/2" = 1'-0"I-002-1 <br />C <br />CONDUIT THRU NON-FIRE RATED IMP <br />WALL DETAIL <br />NO. DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />REGISTERED PROFESSIONAL ENGINEER67268RICHARD MAURICE THIBEAULT <br />STATE OF CALIFORNIACIVIL <br />4/2/24 <br />2350 S Pullman St - <br />Phase I3/4/2025