MOUNTING HEIGHT TABLE <br />DESCRIPTION HEIGHT (AFF)COMMENTS <br />GENERAL RECEPTACLES <br />UNFINISHED AREA RECEPTACLES <br />GENERAL RECEPTACLES <br />ABOVE COUNTER RECEPTACLES <br />OFFICE RACEWAY POWER/DATA <br />RECEPTACLES (CONCRETE CURBS) <br />EXTERIOR RECEPTACLES <br />GENERAL WALL SWITCHES <br />MOTOR STARTERS <br />MOTOR DISCONNECT SWITCHES <br />INTERIOR WALL MOUNTED LIGHTING <br />GENERAL TELEPHONE/DATA OUTLETS <br />TELEPHONE OUTLETS (WALL PHONE) <br />FIRE ALARM SOUNDERS/STROBES <br />FIRE ALARM PULL STATIONS <br />1'-6" <br />3'-8" <br />0'-6" <br />0'-6" <br />1'-0" <br />2'-0" <br />3'-8" <br />6'-0" <br />4'-6" <br />7'-6" <br />1'-6" <br />3'-8" <br />6'-8" <br />3'-8" <br />UNLESS INDICATED OTHERWISE ON DRAWINGS <br />ABOVE COUNTER TO CENTER <br />ABOVE DESK TO CENTER <br />ABOVE TOP OF CURB <br />MINIMUM ABOVE FINAL GRADE <br />TO TOP EXCEPT TOP HANDLE SHOULD NOT EXCEED 78" AFF <br />UNLESS INDICATED OTHERWISE ON DRAWINGS <br />UNLESS INDICATED OTHERWISE ON DRAWINGS <br />WITHIN THE SPACE OR 6" BELOW THE CEILING, WHICHEVER IS LOWER <br />NOTE: ALL MEASUREMENTS "TO CENTER" UNLESS OTHERWISE INDICATED. <br />A <br />ABS <br />AF <br />A.F.F. <br />AL. <br />ANSI <br />APPROX. <br />AT <br />ATC <br />ATS <br />AUX <br />AVG <br />AWG <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />AMP <br />ABSOLUTE <br />AMP FRAME <br />ABOVE FINISHED FLOOR <br />ALUMINUM <br />AMERICAN NATIONAL STANDARDS INSTITUTE <br />APPROXIMATE <br />AMP TRIP <br />AUTOMATIC TEMPERATURE CONTROL <br />AUTOMATIC TRANSFER SWITCH <br />AUXILIARY <br />AVERAGE <br />AMERICAN WIRE GAUGE <br />BAT. <br />BAT. CHG. <br />BAT. CHGR. <br />BFD <br />BOT. <br />BHP <br />BSV <br />BTU <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />BATTERY <br />BATTERY CHARGING <br />BATTERY CHARGER <br />BOILER FEED DISCHARGE <br />BOTTOM <br />BRAKE HORSEPOWER <br />BLEED SOLENOID <br />BRITISH THERMAL UNIT <br />C/B <br />CFM <br />CFH <br />C <br />CLS <br />CM <br />COMPR <br />CONC. <br />COND. <br />CONT. <br />CONTR. <br />CP <br />CPT <br />CR <br />CT <br />CU <br />CUB <br />CU FT <br />CU IN <br />CV <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />CIRCUIT BREAKER <br />CUBIC FEET PER MINUTE <br />CUBIC FEET PER HOUR <br />CENTER LINE <br />COMBINATION LINE STARTER <br />CIRCULAR MILS <br />COMPRESSOR <br />CONCRETE <br />CONDUIT <br />CONTACTOR <br />CONTRACTOR <br />CONTROL PANEL <br />CONTROL POWER TRANSFORMER <br />CONTROL RELAY <br />CURRENT TRANSFORMER <br />COPPER <br />CUBICLE <br />CUBIC FEET <br />CUBIC INCH <br />CONTROL VALVE <br />DP <br />DISC. SW. <br />DIA. <br />ID <br />OD <br />DISCH <br />DN <br />DSV <br />DWG. <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />DISTRIBUTION PANEL <br />DISCONNECT SWITCH <br />DIAMETER <br />DIAMETER, INSIDE <br />DIAMETER, OUTSIDE <br />DISCHARGE <br />DOWN <br />DRAIN SOLENOID VALVE <br />DRAWING <br />EC <br />EF <br />ELP <br />EMERG. <br />EMT <br />ENCL. <br />ENCAS. <br />ENT <br />EWC <br />EWH <br />EXIST. <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />ELECTRICAL CONTRACTOR <br />EXHAUST FAN <br />EMERGENCY LIGHTING PANEL <br />EMERGENCY <br />ELECTRICAL METALLIC TUBING <br />ENCLOSURE <br />ENCASEMENT <br />ENTERING <br />ELECTRIC WATER COOLER <br />ELECTRIC WALL HEATER <br />EXISTING <br />ABBREVIATIONS <br />F <br />FLA <br />FDS <br />FIXT. <br />FT <br />FPM <br />FPS <br />FS <br />FU <br />FUT. <br />FVNR <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />FAHRENHEIT <br />FULL LOAD AMPS <br />FUSIBLE DISCONNECT SWITCH <br />FIXTURE <br />FEET <br />FEET PER MINUTE <br />FEET PER SECOND <br />FLOAT SWITCH <br />FUSE <br />FUTURE <br />FULL VOLTAGE NON-REVERSING <br />GA. <br />GAL. <br />GALV. <br />GEN. <br />GFCI <br />GFPD <br />GND. <br />GP <br />GPM <br />GPH <br />GPD <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />GAGE OR GAUGE <br />GALLON <br />GALVANIZED <br />GENERATOR <br />GROUND FAULT CIRCUIT INTERRUPTING <br />GROUND FAULT PROTECTIVE DEVICE <br />GROUND <br />GLYCOL PUMP <br />GALLONS PER MINUTE <br />GALLONS PER HOUR <br />GALLONS PER DAY <br />H-O-A <br />HGSV <br />HLA <br />HLS <br />HP <br />H.R. <br />HR <br />HT. <br />HTG. <br />HTR. <br />H.V. <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />HAND-OFF-AUTOMATIC SWITCH <br />HOT GAS SOLENOID VALVE <br />HIGH LEVEL ALARM <br />HIGH LEVEL STOP <br />HORSEPOWER <br />HOSE REEL <br />HOUR <br />HEAT TRACE <br />HEATING <br />HEATER <br />HIGH VOLTAGE <br />INFO. <br />IMC <br />INSUL(D). <br />INV. <br />= <br />= <br />= <br />= <br />INFORMATION <br />INTERMEDIATE METAL CONDUIT <br />INSULATE(D), INSULATION <br />INV. <br />JB =JUNCTION BOX <br />KAIC <br />KW <br />KWH <br />KVA <br />KVAR <br />= <br />= <br />= <br />= <br />= <br />KILO-AMP INTERRUPTING CAPACITY <br />KILOWATT <br />KILOWATT HOUR <br />KILOVOLTAMPS <br />KILOVAR <br />LB <br />LF <br />LG <br />LL <br />LLA <br />LLC <br />LLS <br />LP <br />LPL <br />LPR <br />LT <br />LT. <br />LTG. <br />LSIG <br />LSV <br />LV. <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />ELBOW FITTING <br />LINEAR FEET <br />LENGTH <br />LIQUID LEVEL <br />LOW LEVEL ALARM <br />LIQUID LEVEL CONTROLLER <br />LOW LEVEL STOP <br />LIGHTING PANEL <br />LOW PRESSURE LIQUID <br />LOW PRESSURE RECEIVER <br />LONG TIME <br />LIGHT <br />LIGHTING <br />LT, ST, INSTANTANEOUS, GROUND TRIP SETTINGS <br />LIQUID SOLENOID VALVE <br />LOW VOLTAGE <br />MAINT. <br />MATL. <br />MAX. <br />MCB <br />MCC <br />MCCB <br />MCM <br />MDP <br />MECH. <br />MEZZ. <br />MFR. <br />MFG. <br />MIN. <br />MLO <br />MOD <br />MS <br />MSB <br />MTR <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />MAINTENANCE <br />MATERIAL <br />MAXIMUM <br />MAIN CIRCUIT BREAKER <br />MOTOR CONTROL CENTER <br />MOLDED CASE CIRCUIT BREAKER <br />THOUSAND CIRCULAR MILS <br />MAIN DISTRIBUTION PANEL <br />MECHANICAL <br />MEZZANINE <br />MANUFACTURER <br />MANUFACTURING <br />MINIMUM <br />MAIN LUGS ONLY <br />MOTOR OPERATED DAMPER <br />MOTOR STARTER <br />MAIN SWITCH BOARD <br />MOTOR <br />NEC <br />NEMA <br />NPS <br />NPT <br />N.O. <br />N.C. <br />NTS <br />NO <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />NATIONAL ELECTRICAL CODE <br />NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION <br />NATIONAL PIPE- STRAIGHT <br />NATIONAL PIPE- TAPERED <br />NORMALLY OPEN <br />NORMALLY CLOSED <br />NOT TO SCALE <br />NUMBER <br />OA <br />O.C. <br />OZ <br />= <br />= <br />= <br />OIL AIR <br />ON CENTER <br />OUNCE <br />PB <br />PF <br />PH <br />P.L.C. <br />PNL. <br />PRESS <br />PROC. <br />PROG. <br />PP <br />PS <br />PSI <br />PSIG <br />PSV <br />PVC <br />PWR. <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />PULL BOX <br />POWER FACTOR <br />PHASE <br />PROGRAMMABLE LOGIC CONTROLLER <br />PANEL <br />PRESSURE <br />PROCESS <br />PROGRAM <br />POWER PANEL <br />PRESSURE SWITCH <br />POUNDS PER SQUARE INCH <br />PSI GAGE <br />PURGER SOLENOID VALVE <br />POLYVINYL CHLORIDE CONDUIT <br />POWER <br />QTY.=QUANTITY <br />RC <br />RCP <br />REV. <br />RGS <br />RH <br />RPM <br />RP <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />REFRIGERATION COMPRESSOR <br />REFRIGERATION CONTROL PANEL <br />REVIEW, REVISE, REVISION <br />RIGID GALVANIZED STEEL CONDUIT <br />RELATIVE HUMIDITY <br />REVOLUTIONS PER MINUTE <br />RECEPTACLE PANEL <br />SCH <br />SV <br />SW <br />STL <br />S.S. <br />S.P. <br />SSV <br />ST <br />SHT <br />SPD <br />SUBST. <br />SWGR. <br />SYS. <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />SCHEDULE <br />SOLENOID VALVE <br />SOCKETWELD <br />STEEL <br />STAINLESS STEEL <br />STATIC PRESSURE <br />SUCTION SOLENOID VALVE <br />SHUNT TRIP <br />SHORT TIME <br />SURGE PROTECTIVE DEVICE <br />SUBSTATION <br />SWITCHGEAR <br />SYSTEM <br />T <br />TEMP <br />TC <br />T.G. <br />THK <br />T.O.T. <br />TS <br />T-STAT <br />TYP. <br />TSCP <br />TSV <br />TSSW <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />THERMOSTAT <br />TEMPERATURE <br />THERMOCOUPLE <br />TOP OF GRATE <br />THICK(NESS) <br />TOP OF TRAPEZE <br />TEMPERATURE SENSOR <br />THERMOSTAT <br />TYPICAL <br />TWO SPEED CONSEQUENT POLE <br />TRANSFER SOLENOID VALVE <br />TWO SPEED SEPARATE WINDING <br />U.F. <br />UH <br />U.S.D.A. <br />U.N.O. <br /> <br />VEL <br />VSV <br />VERT <br />VISC <br />V <br />VOL <br />W <br />W/ <br />YD <br />XFMR <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br /> <br />= <br /> <br />= <br />UNDERFLOOR <br />UNIT HEATER <br />UNITED STATES DEPARTMENT OF AGRICULTURE <br />UNLESS NOTED OTHERWISE <br />VELOCITY <br />VENT SOLENOID VALVE <br />VERTICAL <br />VISCOSITY <br />VOLT <br />VOLUME <br /> <br />WATT <br />WITH <br />WYE-DELTA <br /> <br />TRANSFORMER <br />ELECTRICAL PLAN SYMBOLS <br />OS <br />$OS <br />$, $ , $ , $ , $ <br />$ , $ <br />3 <br />P D <br />4 WP LH <br />PC <br />IG <br />D, 2D/T, 4D <br />J <br />POWER FACTOR <br />METER <br />ONE-LINE DIAGRAM SYMBOLS <br />PF <br />A <br />V <br />KWH <br />G <br />AS <br />VS <br />T <br />T <br />H <br />M <br />MS <br />F <br />FACP <br />FA <br />FA <br />FS <br />DS <br />CR <br />S <br />D D <br />D H <br />DSH <br />H <br />S <br />AP <br />TS <br />FS <br />AM <br />PS <br />52 <br />TRANSFORMER <br />M <br />M <br />K <br />CONTROL SYMBOLS <br />SWITCH; <br />NORMALLY OPEN <br />H <br />N.O. <br />N.C. <br />INSTANT OPERATING <br />CONTACT, <br />NORMALLY OPEN <br />OL <br />G <br />SUPPR. <br />RES. <br />THERMOCOUPLE <br />+- <br />1. ALL WIRING METHODS, MATERIALS, ETC. SHALL COMPLY WITH AND BE INSTALLED IN ACCORDANCE WITH <br />THE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 3 BASED ON THE 2020 EDITION OF NFPA 70, NATIONAL <br />ELECTRIC CODE (NEC 2020 WITH AMENDMENTS), CALIFORNIA BUILDING ENERGY CODE COMPLIANCE (CBECC), <br />ELECTRIC UTILITY REQUIREMENTS AND ALL APPLICABLE STATE AND LOCAL CODES. PROVIDE ALL LABOR AND <br />MATERIALS FOR A COMPLETE AND OPERATIONAL INSTALLATION WHICH MEETS THE GENERAL INTENT OF THE <br />DRAWINGS, AND WHICH MEETS ALL APPLICABLE CODES. <br />2. COORDINATE LAYOUT AND INSTALLATION OF DISCONNECTS, CONTROL PANELS, CONDUIT, EQUIPMENT <br />SUPPORTING STRUCTURES, ETC. WITH EQUIPMENT SERVED AND ADJACENT SURFACES. MAINTAIN REQUIRED <br />WORKSPACE CLEARANCES, REQUIRED CLEARANCES FOR EQUIPMENT ACCESS DOORS AND PANELS, AND <br />MAINTENANCE ACCESS. THE ELECTRICAL INSTALLATION SHALL NOT IMPEDE ACCESS TO THE EQUIPMENT IT <br />SERVES, OR TO ANY OTHER EQUIPMENT OR AREAS OF THE BUILDING. <br />3. ONLY WHERE WIRE SIZES HAVE BEEN INCREASED FOR VOLTAGE DROP, AND ARE THUS TOO LARGE TO <br />TERMINATE OR CONNECT TO THE FED EQUIPMENT, WITHIN CODE ALLOWANCES THE CONTRACTOR MAY <br />UTILIZE SPLICE BOXES, COMPRESSION/PIGTAIL ADAPTERS, ETC. IN ORDER TO REDUCE THE WIRE SIZE <br />IMMEDIATELY PRIOR TO THE TERMINATION/EQUIPMENT. <br />4. CONTROL PANELS, J-BOXES AND OTHER EQUIPMENT SHALL BE PROVIDED WITH NEMA RATED <br />ENCLOSURES SUITABLE FOR THE AREA WHERE THEY ARE INSTALLED. REFERENCE DESIGN CRITERIA <br />DRAWING "ROOM NEMA CLASSIFICATION" WHICH INDICATES NEMA REQUIREMENTS FOR EACH AREA. WHERE <br />BOXES, CONTROL PANELS, ETC. ARE MOUNTED IN WASHDOWN AREAS, THE SAME SHALL BE PROVIDED WITH <br />SLOPED TOPS. PROVIDE WATERTIGHT, HOSEDOWN RESISTANT SEAL BETWEEN EQUIPMENT AND WALL. IN <br />COOLER AND FREEZER AREAS, AND ALL WASHDOWN AREAS, PROVIDE DEVICES, EQUIPMENT AND WIRING <br />METHODS SUITABLE FOR DAMP LOCATIONS. <br />5. PRIOR TO INSTALLING LIGHTING FIXTURES, ELECTRICAL PANELS, CONDUIT RUNS, DISCONNECTS, AND ALL <br />OTHER ELECTRICAL WORK, THE ELECTRICAL CONTRACTOR SHALL CHECK WITH ALL OTHER TRADES FOR <br />POTENTIAL INTERFERENCES, NOTIFYING THE ENGINEER OF ANY CONFLICTS. <br />6. PROVIDE 4" CONCRETE HOUSEKEEPING PADS FOR ALL FLOOR MOUNTED ELECTRICAL EQUIPMENT. <br />7. THIS LEGEND SHEET IS GENERAL IN NATURE. NOT ALL SYMBOLS AND/ OR DESIGNATIONS MAY APPEAR ON <br />DRAWINGS. <br />8. LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ALL MANUFACTURER'S <br />INSTRUCTIONS. REFER TO NEC ARTICLE 110.3(B). <br />9. SAFETY DISCONNECT SWITCHES WILL BE PROVIDED FOR ALL EQUIPMENT REQUIRING A DISCONNECT <br />MEANS PER THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. DISCONNECT SWITCHES WILL BE <br />PROVIDED WITH NEMA RATED ENCLOSURES FOR USE IN THE ENVIRONMENT WHERE THEY ARE INSTALLED. <br />ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL DISCONNECTS, UNLESS THEY ARE <br />PROVIDED BY THE MANUFACTURER OF THE EQUIPMENT WHICH THEY SERVE, OR UNLESS OTHERWISE NOTED. <br />10. ELECTRICAL CIRCUITS IDENTIFIED FOR ALL PROCESS EQUIPMENT AND APPLIANCES ARE BASED ON <br />INFORMATION RECEIVED. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY THE EXACT VOLTAGE AND LOAD <br />RATING OF ALL PROCESS EQUIPMENT AND APPLIANCES PRIOR TO INSTALLING ANY ELECTRICAL CIRCUITS. <br />11. IN COOLER AND FREEZER AREAS, AND ALL WASHDOWN AREAS, PROVIDE DEVICES, EQUIPMENT AND <br />WIRING METHODS SUITABLE FOR DAMP LOCATIONS. <br />12. ALL EQUIPMENT AND DEVICES SUCH AS ELECTRICAL PANELS, SWITCHBOARDS, MCCs, MOTORS, <br />DISCONNECT SWITCHES, CONTROLLERS, ETC. SHALL BE TAGGED PER OWNER'S NAMING <br />CONVENTIONS/SPECIFICATIONS AND NEC REQUIREMENTS. <br />13. NO ALUMINUM WIRING IS PERMITTED. <br />14. PORTIONS OF THE BUILDING DESIGN ARE BY PERFORMANCE SPECIFICATION. FOR SYSTEMS BASED ON <br />PERFORMANCE SPECIFICATION, THE ENGINEER OF RECORD SHALL COORDINATE WITH ALL ELECTRICAL <br />SYSTEMS, INCLUDING LIGHTING FIXTURES. THIS INCLUDES SYSTEMS SUCH AS THE FIRE SPRINKLER LAYOUT <br />BY THE FIRE PROTECTION ENGINEER/CONTRACTOR. <br /> <br />15. PROVIDE 20% SPARE PHYSICAL SPACE IN ALL MAIN SWITCHBOARDS AND ELECTRICAL PANELS; 10% SPARE <br />BREAKERS, 10% SPARE SPACES. PROVIDE 1 SET SPARE FUSES FOR EACH FUSED DISCONNECT. <br /> <br />16. PANELBOARD AND SWITCHBOARD BASIS OF DESIGN MANUFACTURER IS SCHNEIDER ELECTRIC. <br />17. WHERE ALTERNATE MANUFACTURERS ARE PROPOSED, SUBMIT FOR APPROVAL. CONTRACTOR IS <br />RESPONSIBLE FOR ENSURING THAT ALL ALTERNATE EQUIPMENT MEETS CODE REQUIREMENTS AS WELL AS <br />THE DESIGN INTENT OF THE DRAWINGS (CLEAR WORKING SPACE, ETC.). CONTRACTOR IS RESPONSIBLE FOR <br />ALL COSTS ASSOCIATED WITH USING ALTERNATE MATERIALS. <br />GENERAL NOTES: <br />DISCONNECT SWITCH SCHEDULE <br />KEY AMP-POLE TYPE NEMA HP RATED FUSE <br />A 30A-3P HD 1 YES <br />B <br />C <br />D <br />E <br />F <br />G <br />H <br />J <br />K <br />L <br />M <br />N <br />R <br />N/A <br />P <br />30A-3P HD 4X YES N/A <br />30A-3P HD 3R YES N/A <br />30A-3P HD YES <br />60A-3P HD 12 YES N/A <br />200A-3P HD 3R YES N/A <br />60A-3P HD 4X YES N/A <br />30A-1P GD 3R YES <br />60A-3P HD 3R YES N/A <br />30A-3P HD 1 YES <br />30A-1P GD 12 YES N/A <br />PROVIDED BY MECHANICAL CONTRACTOR/ EQUIPMENT VENDOR <br />30A-1P HD 4X YES N/A <br />60A-1P HD 4X YES N/A <br />DISCONNECT NOTES: <br />HD 3R YES N/A <br />12 <br />RK1 <br />6 AMPS <br />RK1 <br />8 AMPS <br />1. THE NUMBER '1' OR '2' SUFFIX ADDED TO A DISCONNECT SWITCH <br />LETTER REPRESENTS A 120 OR 208 VOLT LOAD. <br />100A-3P <br />7,9,11 <br />MCCEXAMPLE <br />LP 2 <br />4 <br />PANEL OR MCC NUMBER <br />CIRCUIT NUMBER <br />MCC- MOTOR CONTROL CENTER <br /> <br />MSB- MAIN SWITCHBOARD <br /> <br />LP- 480/277 VOLT PANEL <br /> <br />PP- 480/277 VOLT PANEL <br /> <br />RP- 208/120 VOLT PANEL <br /> <br />DP- DISTRIBUTION PANEL <br /> <br />E_ - EMERGENCY PANELS <br /> <br />U- UPS FED PANELS <br />CIRCUIT DESIGNATION SCHEME <br />-- <br />-1 - <br />S HD 4X YES N/A100A-3P <br />T HD 4X YES N/A200A-3P <br />V GD 3R YES N/A30A-2P <br />N/A <br />W <br />W HD 4X YES N/A400A-3P <br />X HD 4X YES N/A60A-3P <br />D <br />CONDUIT RUN <br />HOME RUN TO SOURCE INDICATED <br />CEILING MOUNTED OCCUPANCY SENSOR <br />OCCUPANCY SENSOR WALL SWITCH <br />LINEAR LED FIXTURES - MOUNT AS SHOWN <br />SINGLE, 3-WAY, 4-WAY, WEATHERPROOF, LIGHTED HANDLE <br />SWITCH WITH PILOT LIGHT, DIMMER SWITCH <br />TRUCK DOCK, RAIL DOCK FIXTURES <br />LED LIGHTING FIXTURE - WALL MOUNTED, POLE MOUNTED <br />SPOT, FLOOD <br />EXIT SIGN <br />EMERGENCY BATTERY PACK WITH TWO HEADS <br />PHOTOCELL <br />SINGLE, DUPLEX, QUADRUPLEX RECEPTACLES (GFCI=GROUND FAULT CIRCUIT <br />INTERRUPTER, WP=WEATHER RESISTANT WHILE IN USE WITH WEATHER <br />RESISTANT (WR) RECEPTACLE, U= INTEGRATED USB CHARGE PORT), <br />ISOLATED GROUND RECEPTACLE <br />HEAVY DUTY 250V RECEPTACLE <br />HEAVY DUTY 480V RECEPTACLE <br />FLOOR BOX <br />TELEPHONE <br />PHONE /DATA RJ-45 JACKS: <br />D- (1) PHONE AND (1) DATA JACK <br />2D/T- (1) PHONE AND (2) DATA JACKS <br />4D- (4) DATA JACKS <br />JUNCTION BOX <br />WIRELESS ACCESS POINT <br />PUSH BUTTON <br />FLUSH MOUNTED PANEL <br />SURFACE MOUNTED PANEL <br />TRANSFORMER <br />THERMOSTAT <br />DOOR GASKET HEATER <br />MAGNETIC MOTOR STARTER <br />VFD OR MAGNETIC MOTOR STARTER WITH DISCONNECT <br />CONTACTOR <br />MOTOR DISCONNECT SWITCH <br />MOTOR <br />SINGLE PHASE MANUAL MOTOR STARTER <br />FIRE ALARM STATION <br />FIRE ALARM CONTROL PANEL <br />AUTOMATIC FIRE ALARM DEVICE <br />HORN/ STROBE STATION <br />SMOKE DETECTOR <br />DUCT DETECTOR PROVIDED BY DIVISION 28, INSTALLED BY <br />DIVISION 23, WIRED BY DIVISION 28 <br />HEAT DETECTION <br />COMBINATION SMOKE/ HEAT DETECTION <br />CARD READER <br />SECURITY STATION <br />SECURITY CENTRAL STATION <br />HORN <br />STROBE STATION <br />FIRE AIR COMPRESSOR PRESSURE SWITCH <br />SPRINKLER TAMPER SWITCH <br />SPRINKLER SYSTEM FLOW SWITCH <br />SPRINKLER SYSTEM PRESSURE SWITCH <br />ADDRESSABLE INTERFACE MODULE <br />SPEAKER <br />DATA DROP FROM CEILING <br />GROUND ROD <br />GROUND ROD WITH GROUND TEST WELL <br />AMMETER <br />VOLTMETER <br />KILOWATTHOUR <br />METER <br />AMMETER <br />SWITCH <br />VOLTMETER <br />SWITCH <br />GENERATOR <br />CONNECTORS <br />MOTOR <br />HEATER <br />SWITCH <br />GROUND <br />FUSE <br />CABLE LUGS <br />FUSIBLE SWITCH <br />COMBINATION <br />MOTOR STARTER <br />CIRCUIT BREAKER <br />COMBINATION <br />MOTOR STARTER <br />DRAWOUT MCCB <br />DRAWOUT POWER <br />CIRCUIT BREAKER <br />(LOW VOLTAGE) <br />HIGH VOLTAGE <br />CIRCUIT BREAKER <br />MOLDED CASE <br />CIRCUIT BREAKER <br />FUSIBLE SWITCH <br />HIGH VOLTAGE <br />INTERRUPTER <br />SWITCH <br />GROUND SENSOR <br />POTHEAD <br />CT <br />PT <br />LIGHTNING <br />ARRESTOR <br />MECHANICAL <br />INTERLOCK <br />KEY INTERLOCK <br />SECTIONALIZED BUS <br />SWITCH; <br />NORMALLY CLOSED <br />LIMIT SWITCH <br />PRESSURE <br />SWITCH <br />LIQUID LEVEL <br />SWITCH <br />TEMPERATURE <br />ACTUATED SWITCH <br />FLOW SWITCH <br />HUMIDISTAT <br />SWITCH <br />LIMIT SWITCH <br />HELD CLOSED <br />LIMIT SWITCH <br />HELD OPEN <br /> <br />SINGLE CIRCUIT <br />PUSH BUTTON <br />DOUBLE CIRCUIT <br />PUSH BUTTON <br />MUSHROOM HEAD <br />PUSH BUTTON <br />WOBBLE STICK <br />PUSH BUTTON <br />TWO SINGLE <br />CIRCUIT <br />PUSH BUTTONS <br />ONE DOUBLE <br />CIRCUIT <br />PUSH BUTTONS <br />INSTANT OPERATING <br />CONTACT, <br />NORMALLY CLOSED <br />TIMED CONTACT <br />N.O./ T.C. ENG. <br />TIMED CONTACT <br />N.C./ T.O. ENG. <br />TIMED CONTACT <br />N.O./ T.O. DE-ENG. <br />TIMED CONTACT <br />N.C./ T.C. DE-ENG. <br />THERMAL OVERLOAD <br />RELAYS <br />RELAY COIL <br />SOLENOID COIL <br />PILOT LIGHT <br />(LETTER IND. COLOR) <br />HEATING ELEMENT <br />CIRCUIT BREAKER <br />SUPPRESSOR <br />RESISTOR <br />BELL <br />BUZZER <br />HORN <br />BATTERY <br />DUAL VOLTAGE <br />TRANSFORMER <br />SINGLE VOLTAGE <br />TRANSFORMER <br />TERMINAL IN <br />REFRIGERATION <br />CONTROL PANEL <br />TERMINAL IN PROGRAMMABLE <br />CONTROLLER (INPUT) <br />TERMINAL IN PROGRAMMABLE <br />CONTROLLER (OUTPUT) <br />TERMINAL IN PACKAGE <br />CONTROL CABINET <br />TERMINAL IN MOTOR <br />CONTROL CENTER <br />TERMINAL IN DEFROST <br />CONTROL PANEL <br />WIRES CONNECTED <br />WIRES NOT CONNECTED <br />PANEL WIRING <br />MECHANICAL INTERLOCK <br />FIELD WIRING <br />ROUND LED FIXTURE - MOUNT AS SHOWN <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />E-001-1 <br />ARL <br />SEL <br />04/02/2024 <br />ELECTRICAL COVER <br />SHEET <br />2350 Pullman WSS OCTA Aspire <br />Bakeries <br />2350 Pullman Street <br />Santa Ana, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />Pullman,LLC <br />SHEET INDEX - ELECTRICAL - PHASE 1 <br />SHEET <br />NUMBER SHEET NAME <br />E-001-1 ELECTRICAL COVER SHEET <br />E-002-1 PROPOSED ONE-LINE DIAGRAM - PHASE 1 <br />ED050-1 FLOOR PLAN ELECTRICAL DEMOLITION <br />ES100-1 ELECTRICAL SITE PLAN - PHASE 1 <br />EL101-1 FLOOR PLAN LIGHTING <br />EP102-1 FLOOR PLAN POWER <br />ER100-1 OVERALL ROOF PLAN ELECTRICAL <br />E-400-1 ELECTRICAL DETAILS <br />E-401-1 ELECTRICAL DETAILS <br />E-601-1 ELECTRICAL PANEL SCHEDULES <br />E-602-1 ELECTRICAL SCHEDULES CERTIFICATE OF COMPLIANCE <br />NO.DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />B 01/07/2025 BULLETIN #5R1 - PHASE 1 <br />B <br />05- <br />REGISTERED PROFESSIONAL ENGINEER24467 <br />STEPHEN E LASLO <br />STATE OF CALIFORNIA <br />1/7/25 <br />2350 S Pullman St - <br />Phase I3/4/2025