Laserfiche WebLink
, <br />MLO <br />H5 <br />480/277VV <br />3PH 4W <br />400A <br />MSB (DISTRIBUTION <br />SECTION) <br />3000A <br />480V/277V <br />3P, 4W <br />65 KAIC <br />400A 400A 400A 100A <br />, <br />MLO <br />H6 <br />480/277V <br />3PH 4W <br />400A <br />, <br />MLO <br />H2 <br />480/277V <br />3PH 4W <br />400A <br />, <br />MLO <br />H7 <br />480/277V <br />3PH 4W <br />400A <br />100A <br />, <br />MLO <br />H1 <br />480/277V <br />3PH 4W <br />200A <br />EXISTING <br />FEEDER <br />ATS - H1 <br />225A, 3P <br />300A <br />SPIRAL OVEN <br />CONTROL PANEL <br />100A <br />, <br />MLO <br />H9 <br />480/277V <br />3PH 4W <br />125A <br />200A <br />, <br />MLO <br />H11 <br />480/277V <br />3PH 4W <br />200A <br />200A <br />, <br />MLO <br />H4 <br />480/277V <br />3PH 4W <br />200A <br />200A <br />, <br />MLO <br />H3 <br />480/277V <br />3PH 4W <br />200A <br />800A <br />, <br />MLO <br />H10 <br />480/277V <br />3PH 4W <br />800A <br />200A <br />E N <br />L <br />SPACE <br />CONVEYOR <br />CONTROL PANEL <br />45A <br />SPARE <br />EXISTING MSB <br />SECTION) <br />3000A, 480/277V <br />3P, 4W WITH <br />METERING AND <br />SWITCH <br />REMOVED <br />65 KAIC <br />NEW MSB <br />(INCOMING <br />SECTION) <br />3000A, 480V/277V <br />3P, 4W <br />65 KAIC <br />45 KVA <br />, <br />MLO <br />LB <br />208/120VV <br />3PH 4W <br />100A <br />75 KVA <br />, <br />MLO <br />LA <br />208/120VV <br />3PH 4W <br />200A <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />EXISTING <br />FEEDER <br />M <br />LSIG1200 AF <br />1200 AT <br />NEW UTILITY <br />REVENUE <br />METERING <br />NEW MAIN <br />SERVICE <br />DISCONNECT <br />1000 KVA480/277V SECONDARY <br />U <br />NEW INCOMING UNDERGROUND SERVICE <br />LATERAL BY UTILITY. <br />NEW SERVICE CONDUCTORS (4 SETS OF <br />CONCRETE ENCASED 4" CONDUITS) EACH <br />CONTAINING (4) 350 KCMIL. <br />NEW UTILITY OWNED OUTDOOR PAD <br />MOUNTED TRANSFORMER. <br />METERING & 1200A, 480/277V, 65 KAIC <br />INSULATED CASE CIRCUIT BREAKER IN <br />NEMA 3R ENCLOSURE. <br />NEW FEEDER (4 SETS OF 3" CONDUITS) EACH <br />CONTAINING (4) 350 KCMIL AND #3/0G. <br />OUTDOORS <br />INDOORS <br />LEGEND <br />HALFTONE LINEWORK AND TEXT INDICATES EXISTING. <br />FULLTONE LINEWORK INDICATES PROPOSED. <br />GND <br />N <br />NEUTRAL TO GROUND BONDING JUMPER. <br />, <br />MCB <br />L10 <br />208/120VV <br />3PH 4W <br />100A <br />X1045 KVA <br />1 1/4"C - 3#4AWG, #8G <br />1 1/4"C - 4#3, #8G <br />ELECTRICAL SERVICE #1 <br />(NOTE 1 TYPICAL) <br />NOTE 2 <br />E-400-1 <br />A <br />E-400-1 <br />D <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />E-002-1 <br />DLJ <br />SEL <br />11/05/2024 <br />PROPOSED <br />ONE-LINE DIAGRAM <br />- PHASE 1 <br />2350 Pullman WSS OCTA Aspire <br />Bakeries <br />2350 Pullman Street <br />Santa Ana, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />Pullman,LLC <br />NO SCALEE-002-1 <br />2 PROPOSED ONE-LINE DIAGRAM - PHASE 1 <br />NO.DATE DESCRIPTION <br />A 11/05/2024 BULLETIN #3 - PHASE 1 <br />B 01/07/2025 BULLETIN #5R1 - PHASE 1 <br />LOAD SUMMARY TABLE (KVA) <br />EXISTING PEAK LOAD <br />BUILDING EXPANSION <br />ELECTRIC VEHICLE STATIONS <br />ANTICIPATED PEAK LOAD <br />500 <br />109 <br />0 <br />614 <br />SITE LIGHTING 5 <br />A <br />B <br />NOTES: <br />1.REFER TO "DETAIL A - GROUNDING WIRING TYPICAL DETAIL" ON SHEET "E-400-1". <br />2. REFER TO "DETAIL D - XFMR AND PANEL TYPICAL GROUNDING DETAIL" ON SHEET E-400-1". <br />B <br />B <br />B <br />05- <br />REGISTERED PROFESSIONAL ENGINEER24467 <br />STEPHEN E LASLO <br />STATE OF CALIFORNIA <br />1/7/25 <br />2350 S Pullman St - <br />Phase I3/4/2025