Laserfiche WebLink
1 2 3 <br />F <br />G <br />H <br />J <br />N3 <br />N1 <br />N4 <br />N5N6 <br />N2 <br />NA NAANBNCNDNENF <br />K2-140 <br />D-102 <br />H1 <br />(EX.)-28 <br />D-102-EM <br />D-102 <br />H1 <br />(EX.)-28 <br />D-102 <br />H1 <br />(EX.)-28 <br />D-102-EM <br />D-102 <br />H1 <br />(EX.)-28 <br />NOTE 5 <br />NOTE 3 <br />X1 <br />NOTE 1A <br />NOTE 1C <br />NOTE 1C <br />NOTE 1D <br />NOTE 1D <br />EX <br />X1 <br />J4-19-EM <br />D-102-EM D-102 <br />J4-19-EMX1 <br />NOTE 1 <br />NOTE 2 <br />NOTE 1B <br />NOTE 3 <br />NOTE 3 <br />DOCK ADDITION <br />131 <br />TEMPORARY <br />TENT <br />133 <br />EXISTING <br />COOLER <br />102 <br />EXISTING <br />FREEZER <br />103 <br />EXISTING <br />ELECTRICAL <br />ROOM <br />101 <br />NOTE 4 <br />(TYP) <br />J4-19-EM <br />NOTE 5 <br />J4-19-EM <br />NOTE 3 <br />X1 <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />EL101-1 <br />DLJ <br />SEL <br />04/02/2024 <br />FLOOR PLAN <br />LIGHTING <br />2350 Pullman WSS OCTA Aspire <br />Bakeries <br />2350 Pullman Street <br />Santa Ana, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />Pullman,LLC <br />NOTES: <br />1. PROJECT CONSTRUCTION WILL INVOLVE BOTH THE INSTALLATION AND REMOVAL OF A TEMPORARY TENT DURING CONSTRUCTION. REFER <br />TO NOTES 1A, 1B, 1C, AND 1D BELOW. VERIFY TEMPORARY TENT REQUIREMENTS AND COORDINATE ALL ELECTRICAL WORK, ELECTRICAL <br />DEMOLITION, AND SCHEDULING INVOLVED. <br /> <br />1A. TEMPORARY TENT - EXPANDED AREA LIGHTING. FURNISH AND INSTALL (1) TYPE D-102 & (1) TYPE D-102-EM LIGHTING FIXTURES <br />APPROXIMATELY 15' AFF AT LOCATIONS INDICATED. EXTEND (1) LOCAL 20A NORMAL/EMERGENCY LIGHTING CIRCUIT OR PROVIDE NEW <br />NORMAL/EMERGENCY CIRCUIT FROM PANEL "H1" IN EXISTING ELECTRICAL ROOM TO NEW LIGHTING IN THIS AREA. SALVAGE LIGHTING <br />FIXTURES FOR FUTURE INSTALLATION WHEN TENT IS REMOVED AND DEMOLISH TEMPORARY BRANCH CIRCUITING. <br />1B. TEMPORARY TENT - TEMPORARIILY SUSPEND EXISTING DOCK AREA LIGHTING/CONTROL DURING INITIAL INSTALLATION OF TENT. REMOVE <br />EXISTING DOCK AREA LIGHTING/CONTROL AND ASSOCIATED BRANCH CIRCUITING WHEN TENT IS REMOVED. <br />1C. INSTALL TYPE X1 EXIT SIGN OVER INTERIOR SIDE OF EGRESS DOOR AS INDICATED. TEMPORARILY EXTEND LOCAL EMERGENCY LIGHTING <br />CIRCUIT. RELOCATE TO EGRESS DOOR WHEN TENT IS REMOVED. <br />1D. INSTALL TYPE J4-19-EM LIGHTING FIXTURE ON EXTERIOR SIDE OF EGRESS DOOR AT 10' AFF. TEMPORARILY EXTEND EXISTING EMERGENCY <br />LIGHTING CIRCUIT AND CONTROL. SALVAGE FIXTURE FOR FUTURE INSTALLION WHEN TENT IS REMOVED. <br />2. INSTALL TYPE K2-140 LIGHTING FIXTURE AT APPROXIMATELY 22' AFG. EXTEND EXISTING EXTERIOR LIGHTING CIRCUIT/CONTROL. REFER TO <br />NOTE 6 ON DRAWING ED050-1. <br />3. EXTEND LOCAL NORMAL/EMERGENCY LIGHTING CIRCUIT TO FIXTURE. <br />4. INSTALL TYPE D-102 AND D-102-EM LIGHTING FIXTURES. MOUNT BOTTOM OF FIXTURES AT 19' AFF. <br />5. INSTALL TYPE J4-19-EM LIGHTING FIXTURE ON EXTERIOR SIDE OF EGRESS DOOR MATCH EXISTING MOUNTING HEIGHTS OF EGRESS <br />LIGHTING. EXTEND LOCAL NORMAL/EMERGENCY LIGHTING CIRCUIT AND CONTROL. <br /> 1/8" = 1'-0"EL101-1 <br />1 FLOOR PLAN LIGHTING - PHASE 1 <br />NO.DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />REGISTERED PROFESSIONAL ENGINEER24467 <br />STEPHEN E LASLO <br />STATE OF CALIFORNIA <br />4/2/24 <br />2350 S Pullman St - <br />Phase I3/4/2025