Laserfiche WebLink
001 <br />001 <br />037 <br />001 <br />001 <br />004 <br />001 <br />037 <br />035035035 <br />035 <br />037 <br />157 <br />002 <br />038 <br />V.I.F. <br />28' - 7" <br />V. <br />I <br />. <br />F <br />. <br />31 <br />' <br /> <br />- <br /> <br />1 <br />" <br />5" <br />V. <br />I <br />. <br />F <br />. <br />31 <br />' <br /> <br />- <br /> <br />0 <br />" <br />V.I.F. <br />60' - 5" <br />001 <br />024 <br />038 <br />V.I.F. <br />60' - 5" <br />039 <br />039 <br />037037 <br />002 <br />009 <br />009 <br />A B C <br />1 <br />2 <br />3 <br />4 <br />166 <br />009 <br />EXISTING METAL STUD WALL <br />EXISTING CONCRETE WALL <br />EXISTING WALL TO BE REMOVED <br />EXISTING STOREFRONT SYSTEM TO BE REMOVED <br />EXISTING DOOR/FRAME/HW TO BE REMOVED <br />SAWCUT AND REMOVE PORTION <br />OF (E) CONCRETE SLAB (INCLUDING CONCRETE <br />CURBS FOR WALLS TO BE DEMOLISHED) <br />EXISTING ITEM & EQUIPMENT <br />TO BE DEMOLISHED <br />SLAB DEMOLITION AT NEW RESTROOM LOCATION <br />IN SUPPORT OF MORTAR BED TILE INSTALLATION <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />Issue Date <br />A01.3 <br />DEMOLITION - <br />ENLARGED <br />PLANS <br />#2022-40198 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />001 EXISTING DOOR & FRAME TO BE REMOVED IN ITS <br />ENTIRETY <br />002 EXISTING WINDOW & FRAME TO BE REMOVED IN ITS <br />ENTIRETY, PREP FOR NEW STOREFRONT ENTRY <br />004 DEMOLISH EXISTING CASEWORK/CABINETRY AS <br />SHOWN <br />009 SAWCUT AND REMOVE HATCHED PORTION OF <br />EXISTING CONCRETE SLAB FOR POWER RUN TO <br />NEARBY FURNITURE, REPLACE SLAB IN KIND <br />FOLLOWING ELECTRICAL WORK, SEE E102 FOR <br />REQUIREMENTS AND ADDITIONAL INFORMATION (SLAB <br />TO BE REPLACED WITH NEW WORK) <br />024 EXISTING CONCRETE COLUMNS TO REMAIN (ALL <br />FRAMED WALLS SHALL BE REMOVED) <br />035 EXISTING WINDOW TO REMAIN & PROTECTED IN PLACE <br />037 EXISTING WALL TO BE DEMOLISHED <br />038 EXISTING WALL AND STRUCTURAL FRAMING TO BE <br />PROTECTED-IN-PLACE DURING CONSTRUCTION, TYP. <br />039 EXISTING GYP AND FINISHES TO BE DEMOLISHED, <br />PROTECT STRUCTURAL FRAMING FOR NEW WALL <br />157 REMOVE AND PRESERVE EXISTING MURAL TO BE AND <br />RELOCATED, SEE SHEET A11.3 FOR LOCATION <br />166 EXISTING WINDOW TO REMAIN, PROTECT IN PLACE <br />1/4" = 1'-0"1DEMOLITION ENLARGED FLOOR PLAN <br />KEYNOTES <br />DEMO PLAN LEGEND <br />DESCRIPTION DATE <br />N <br />7/08/24 <br />505 E Central Ave <br />#B11/6/2024