My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
Text box
ID:
1
Creator:
Import Agent
Created:
2/24/2026 5:01 AM
Modified:
2/23/2026 12:54 PM
Text:
07/08/24
Rectangle
ID:
1
Creator:
Import Agent
Created:
2/24/2026 5:01 AM
Modified:
2/23/2026 12:54 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
HATCHED AREA NOT IN SCOPE <br />A01.3 <br />1 <br />1 <br />A21.0 <br />2 <br />A21.0 <br />A B <br />C <br />1 <br />2 <br />3 <br />4 <br />A01.5 <br />1 <br />1. DEMOLITION DRAWINGS PREPARED BY THE ARCHITECT ARE FOR A GENERAL DESCRIPTION OF <br />EXISTING BUILDING COMPONENTS, ASSEMBLIES AND MATERIALS TO BE REMOVED. DEMOLITION <br />CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND QUANTITIES. <br />2. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR PROVIDING NECESSARY PERMITS REQUIRED <br />BY FEDERAL, STATE AND LOCAL MUNICIPAL AGENCIES HAVING JURISDICTIONAL AUTHORITY <br />OVER ANY ASPECT OF THE DEMOLITION SCOPE. <br />3. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO DEMOLITION WORK. <br />4. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL <br />DEMOLISHED MATERIALS IN A MANNER COMPLIANT TO FEDERAL, STATE AND LOCAL MUNICIPAL <br />REQUIREMENTS AND GUIDELINES. <br />5. DEMOLITION CONTRACTOR SHALL COORDINATE ALL WORK SCHEDULES WITH OWNER. IN NO <br />CASE SHALL DEMOLITION WORK BE CONDUCTED DURING HOURS PROHIBITED BY LOCAL <br />MUNICIPALITY. <br />6. PLANS ARE BASED ON EXISTING RECORD DRAWINGS AND VISUAL OBSERVATION. <br />UNIDENTIFIED ITEMS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNERS <br />REPRESENTATIVE PRIOR TO REMOVAL. <br />7. CONTACT OWNER'S REPRESENTATIVE FOR LIST OF SALVAGEABLE ITEMS. <br />8. REMOVE EXISTING CEILING FINISHES (ACOUSTICAL TILE) AND SUBSTRATE (GYPSUM BOARD, <br />PLASTER) AND RELATED SUSPENSION SYSTEMS WHERE NOTED ON DRAWINGS IN ALL ROOMS <br />DESIGNATED TO RECEIVE NEW CEILING FINISHES (AND SUSPENSION SYSTEMS) PER INTERIOR <br />FINISH SCHEDULE. <br />9. REMOVE EXISTING WALL FINISHES (CERAMIC TILE, VINYL WALL COVERING, PLYWOOD, <br />GYPSUM BOARD SUBSTRATES, PLASTER, ETC.) IN ALL ROOMS DESIGNATED TO RECEIVE NEW <br />WALL FINISHES PER INTERIOR FINISH SCHEDULE. <br />10. REMOVE EXISTING FLOORING & BASE (CERAMIC TILE, CARPET, PADDING AND ACCESSORIES) <br />IN ALL ROOMS DESIGNATED TO RECEIVE NEW FLOORING AND BASE PER INTERIOR FINISH <br />PLANS. <br />11. REPAIR ALL SURFACES DESIGNATED TO RECEIVE NEW FLOOR, WALL, AND CEILING FINISHES <br />AS REQUIRED TO PROVIDE A SOUND AND FLUSH SUBSTRATE. <br />12. ALSO REFERENCE CIVIL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL <br />DEMOLITION DRAWINGS FOR ADDITIONAL COORDINATION OF ITEMS TO BE REMOVED OR <br />PROTECTED IN PLACE. <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />Issue Date <br />A01.2 <br />DEMOLITION - <br />OVERALL FLOOR <br />PLAN <br />#2022-40198 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />1/8" = 1'-0"1DEMOLITION OVERALL FLOOR PLAN DEMOLITION NOTES <br />DESCRIPTION DATE <br />N <br />7/08/24 <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.