My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />55 <br />liquid asphalt formulation as required, such as to improve coating or adjust breaking <br />properties. The Contractor shall provide current test results and a Certificate of <br />Compliance for liquid asphalt at the time of mix design submittal and for each load <br />delivered to the jobsite. For bidding purposes, the emulsified recycling agent content <br />is assumed to be 2.4%. <br />Water <br />Water shall be added to facilitate the uniform mixing of the liquid asphalt and the <br />cold milled material. Water used for cold recycling shall be clean and free of foreign <br />substances and shall not cause an adverse effect on either the liquid asphalt or the <br />recycled pavement mixture. Water added by the milling machine shall be measured, <br />and the rate of added water can be between 0.5 and 5.0 percent of water added by <br />weight of the recycled pavement mixture per the approved mix design unless a <br />greater variation has been directed by the person designated by the Contractor to <br />make adjustments in the field. The quantity of residual recycling agent in the final <br />recycled pavement mixture shall not vary due to the addition of water. <br />Additives <br />No additives shall be allowed in the cold recycled pavement. <br />D. MIX DESIGN <br />At least 14 days prior to beginning the recycling operation, the Contractor shall <br />submit a CIREAM mix design to the Engineer. The mix design shall be prepared <br />under the supervision of and signed by an Engineer licensed by the State of <br />California. Prior to commencing the work, the Contractor shall obtain samples that <br />are representative of the material that will be produced during the milling operation. <br />Samples used in the mix design shall be obtained directly from the project site either <br />by coring or milling, as approved by the Engineer. These samples shall be used to <br />establish the design rate of expanded asphalt as a percent by mass of the recl aimed <br />asphalt pavement. The design rate of the expanded asphalt shall be a minimum of <br />1.0%. Based on the characteristics of the reclaimed asphalt pavement taken from the <br />project site, more than one mix design may be required. The mix design for the <br />recycled pavement mixture shall conform to the requirements in the Wirtgen Cold <br />Recycling Manual’s Appendix A2.3. <br />The CIREAM shall meet the following minimum physical requirements: <br />Property Minimum Requirement <br />Dry Tensile Strength 50 psi <br />Wet Tensile Strength 25 psi <br />Tensile Strength Ratio (TSR) 50% <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.