My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />92 <br />Written warranty must be provided by manufacturer for full replacement of the module <br />due to any failure for a minimum period of fifteen (15) years. <br />The LED signal module manufacturer shall provide a detailed written warranty issued by <br />the factory of module origin with the following minimum provisions: <br />- Modules shall, at the manufacturer’s option, be repaired or replaced if the module fails <br />to function as intended due to workmanship or material defects within the first 15 years <br />from the date of delivery. <br />- Modules shall, at the manufacturer’s option, be repaired or replaced if the module <br />exhibit luminous intensities less than the minimum specified values within the first 15 <br />years of the date of delivery. <br />4.23 VEHICLE DETECTORS <br />Detectors and detector lead-in cable shall conform to the provisions in Section 86- <br />1.02F(2)(c)(iii), "Inductive Loop Conductors" Section 86-1.02W, “Loop Detector Sealants,” <br />Section 87-1.03V, “Detectors,” Section 87-1.03W, “Sealants,” of Caltrans Standard <br />Specifications and these Special Provisions. <br />Loop wire shall be Type 2. Loop detector lead-in cable shall be Type B. <br />Loop sealant can be Asphaltic Emulsion Sealant or Hot-Melt Rubberized Asphalt <br />Sealant. <br />Unless shown otherwise on the plans, all new inductive loop detectors shall be round, 6' <br />(1.8 m) diameter, per CSP plan ES-5B, Type E. <br />All loop connection shall be in series only. <br />Bicycle Loop Detectors in Vehicle lane shall be per CSP Type D Circular. Bicycle Loop <br />Detectors in Bicycle lane shall be per CSP Type Q. <br />All new or modified loop curb terminations shall be Type A as shown in CSP ES-5D. <br />Curb termination conduit shall be 2” (53mm). <br />If any inductive loop detector wires or loop detector lead-in cables are to be left un- <br />terminated in a pull box for more than a 24 -hour period, the ends shall be securely taped <br />and sealed with an electrical insulating coating. <br />4.24 PEDESTRIAN PUSH BUTTON ASSEMBLIES <br />Pedestrian push button assemblies shall conform to Section 86-1.02U and 87-1.03U, <br />“Push Button Assemblies,” of the Caltrans Standard Specifications and these special <br />provisions. <br />Unless shown otherwise on the plans, Pedestrian Push Button shall be Type B <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.