My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />99 <br />Signal Interconnect Cable (SIC) shall be AWG#22 and conform to IMSA <br />Specification 40-2, REA Specification PE-39 and the following: <br />SIC shall not be spliced unless shown otherwise on the plan. The number of pairs to <br />be provided shall be as shown on the plans. The ends of unused SIC conductors shall <br />be folded back and taped securely to the cable <br />Where splicing is required, the Contractor is responsible for supplying the splice <br />closures and all accessories including bond connectors and proper end plates to <br />provide splices as recommended by the manufacturer. <br />Manufacturer recommended lubricant shall be applied to the cable to reduce friction <br />between the cable and the duct. Mechanical aids and pulling cable or ropes shall be <br />used as required. <br />Personnel shall be stationed at each cabinet, splice vault and/or pull box through <br />which the cable is to be pulled to observe and lubricate the cable. <br />At least ten feet of slack shall be provided at each pull box. The shield shall be <br />grounded at each trunk splice and at every terminus point. <br />The cable shall be securely fastened in-place within pull boxes, vaults, and/or <br />cabinets. <br />The cable shall not be stressed beyond the Manufacturer's minimum bending radius at <br />any time. <br />All exposed cable ends shall be protected from moisture ingress. <br />Following installation of the cable in the duct, all duct entrances at pull boxes, vaults <br />and cabinets shall be sealed with duct sealing compound to prevent the ingress of <br />moisture, foreign materials, and rodents. <br />Cable markers shall be used to identify the cable and pair-count. <br />The Contractor is responsible for all testing and documentation required to establish <br />approval and acceptance of the production, installation and operation of fabrication <br />materials and installation hardware. The following identifies the specific quality <br />control requirements for this specification. <br />Cables shall be tested at the factory to ensure the cable complies with the <br />specifications. <br />Reels of cable shall be tested for insulation breakdown and continuity prior to <br />installation in ducts. <br />As a post-installation check, the Contractor shall measure the continuity and <br />insulation breakdown of the cable pairs in each length of cable after installation, prior <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.