My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
Text box
ID:
1
Creator:
Import Agent
Created:
2/24/2026 5:01 AM
Modified:
2/23/2026 12:54 PM
Text:
http://www.preformed.com/
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />100 <br />to connection. The Contractor shall measure these parameters on a minimum of two <br />pairs selected by the Engineer. The same pairs shall not be measured on consecutive <br />lengths. <br />The Contractor shall record the reel number from which the cable came, the <br />identification of the pairs measured, and the results of continuity and insulation tests. <br />The Contractor shall carry out system integration testing to ensure that the twisted- <br />pair cables perform as specified when used in operation with equipment installed <br />under the contract. <br />Where splicing is required inside the pull box or splice vault, the Contractor is <br />responsible for supplying the splice kits and all accessories including bond connectors <br />and proper end plates to provide splices as recommended by the manufacturer. <br />Unless noted otherwise, splice kit shall be COYOTE Series manufactured by <br />Performed Line Products, www.preformed.com. All splicing shall be done by the <br />Contractor, the City will supply necessary wiring information or splicing diagram. <br /> <br />Individual wire splicing shall be done using weather resistant connector (AMP <br />Picabond Connector. <br />B. FIBER OPTIC CABLE <br />This work consists of installation of Single Mode Fiber Optic Cable per plan. <br />This work shall be in accordance with the Plans, Section 87-19, “Fiber Optic Cable <br />Systems,” of the Caltrans Standard Plans & Specifications and these Special <br />Provisions. <br />Each fiber optic cable for this project shall be Corning Cable Systems, ALTOS Lite <br />Gel-Free Cables, Single-Jacket/Single-Armor type, loose tube and contain single <br />mode (SM) dual-window (1310 nm and 1550 nm) fibers as shown on the Plans and <br />shall conform to these special provisions. <br />The drop cables shall be connectorized with SC connectors in the cabinets. This shall <br />require additional aramid strength members in the cable or the use of furcation tubing <br />at the terminus. <br />1. Quality Assurance Provisions <br />Documentation of factory test results shall be provided to the Engineer for <br />approval prior to shipping. <br />The attenuation of 100 percent of the fibers shall be tested by the Manufacturer <br />and certified as satisfying the requirements of this specification. A copy of the <br />test results for each fiber in the cable shall be provided with each reel of cable. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.