My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />101 <br />Attention is directed to "Fiber Optic Testing," elsewhere in these special <br />provisions. <br />The Contractor shall furnish a Manufacturer's certification that the fiber optic <br />cable materials proposed for use on this project will meet all applicable special <br />provisions. <br />The material shall not be installed in the field prior to the Engineer's approval. <br />2. Installation <br />Installation procedures shall conform to the procedures specified by the <br />Manufacturer of the specific cable being installed. <br />Prior to installing the optical fiber cable, the Contractor shall test the cable on the <br />shipping reel. The Contractor shall submit the manufacturer's recommended <br />procedures for pulling the fiber optic cable to the Engineer for review and <br />approval at least 20 working days prior to installing cables. Mechanical aids may <br />be used to assist cable installation. A tension measuring device or break away <br />swivel shall be placed between the end of the cable grip and the pull rope, to <br />ensure that the tension does not exceed 80 percent of recommended tension or <br />2225 N, whichever is less. The cable grips for installing fiber optic cable shall <br />have a ball bearing swivel to prevent the cable from twisting during installation. <br />The fiber optic cable shall be installed using a cable pulling lubricant <br />recommended by the fiber optic cable and/ the innerduct manufacturer and a non- <br />abrasive pull tape conforming to the provisions described under "Conduit" <br />elsewhere in these special provisions. Contractor’s personnel shall be stationed at <br />each splice vault and pull box through which the cable is to be pulled to lubricate <br />and prevent kinking or other damage. <br />During cable installation, the bend radius shall be maintained at a minimum of 20 <br />times the outside diameter of the cable. <br />Splices shall only be allowed at cable transitions, such as, changes in the size of <br />cables or at entry points for drop-cables. Splice closures shall be required at <br />every junction point and at every device being serviced by the fiber optic cable as <br />indicated on the fiber optic conductor schedules. At each splice closure, all <br />useable fibers in the cable shall be continuously spliced as indicated on the plans. <br />The end-to-end attenuation of the completed cable plant shall not exceed 8 dB <br />from the termination point of the fiber to the City of Santa Ana Traffic <br />Management Center. A minimum of 15 feet of slack shall be maintained on <br />either side of any splice enclosure. <br />Following installation of the cable in duct, all duct entrances in cabinets, pull <br />boxes and vaults shall be sealed with duct sealing compound to prevent the <br />ingress of moisture, foreign materials and rodents. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.