My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />114 <br />3. Electrical for Master Control Valve <br />a. Wires from the master control valve to the controller shall consist of one (1) <br />purple-coated and one (1) white-coated and color-striped same color as pilot <br />wire THWN/THNN type, U.L. approved, AWG number 14 solid strand <br />copper wire. <br />b. All wiring to be continuous without splices from the irrigation controller to <br />the master control valve. <br />c. All wiring shall be installed in conduit from the valve to the controller. <br />4. Control valve to be housed with the flow meter in a common rectangular valve <br />box with locking lid marked "F.M." "M.C.V.". <br />K. MOISTURE SENSORS <br />1. Installation of moisture sensors shall be the responsibility of the Contractor. All <br />sensor locations should be marked on record plans as well as in the field. At each <br />sensor, provide a 1-1/2 inch x 12-inch PVC pipe with a cap within 2 inches of <br />sensor, set flush with finish grade, for future location of unit. Correct sensor <br />placement and installation shall be verified before project is signed off. The <br />Engineer shall call material supplier before project is signed off to verify the <br />proper installation and operation of all moisture sensors <br />2. Location decision of the moisture sensors is provided by the material supplier. <br />The Contractor shall contact material supplier in determining sensor placement. <br />However, the Contractor must have the controller installed with field station wires <br />hooked up according to plan. There must be electricity to the controller, as well <br />as lateral lines installed and irrigating respected areas. The Contractor shall <br />contact material supplier 5 working days in advance when scheduling an <br />appointment for sensor flagging. <br />3. Material supplier field representative shall provide on-site evaluation of the <br />project area. Groups of similar areas are determined and flagged with the <br />Contractor as to where a moisture sensor should be installed. A demonstration on <br />how to install a moisture sensor is also given. By physically viewing coverage, <br />types of heads, soil types, exposure, and varying plant material, proper sensor <br />placement is assured. <br />4. Wiring: <br />a. Wires shall be direct burial from the remote control valve to the moisture <br />sensor. They shall consist of one (1) yellow-coated and one (1) white-coated and <br />color-striped same color as pilot wire U.F. type, U.L. approved, AWG number 14 <br />solid strand copper wire with minimum 4/64" PVC coating, 600 volt, 75oC. <br />b. Connections shall be water tight epoxy cast Scotch Pak-3470 or equal. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.