My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />154 <br /> <br />All labor and equipment necessary to conduct these tests shall be furnished by the <br />contractor. <br />The contractor shall submit all laser profile documents to the Engineer for review and <br />approval no later than (10) days after the test. <br />6.11 NEW MANHOLE STRUCTURES <br />Construction of new concrete manhole structures shall be done in accordance with City <br />of Santa Ana Standard No. 1201, details as shown on the plans, the applicable provisions <br />of Sections 201, 303, and 306 of the Standard Specifications and these Special <br />Provisions. This work shall also include the removal and/or modification of any <br />interfering portions of existing sewer pipes, drop inlets, PCC encasements, etc., necessary <br />to construct each manhole structure complete in place. <br />Concrete for manhole structures shall be Class 560-C-3250. All reinforcing steel used in <br />these structures shall be Grade 40 minimum. Fly ash additives and/or substitutes shall <br />not be permitted. <br />The following is hereby added to Subsection 201-4.1, of the Standard Specification: <br />Concrete curing compound shall be Type 2. <br />The following is hereby added to Subsection 303-1.1, of the Standard Specification: <br />Once any excavation for the construction of a manhole structure is commenced, <br />the Contractor must diligently pursue the completion of the structure, including <br />structure backfill, compaction, and restoration of surface improvements and <br />temporary paving. Open excavations shall be properly barricaded, backfilled or <br />covered with steel traffic plates to the satisfaction of the Engineer at the end of <br />each workday. <br />For new manholes on large sewer mains, or for manholes with extreme depths of cover, a <br />larger diameter manhole will be required. The design of these larger manholes shall be <br />reviewed with and approved by the Water Resources Division. The larger manhole cover <br />shall be in accordance with Standard Plan No. 1211 and these Special Provisions. <br />For larger manhole frames and covers, the Water Resources Division may require frames <br />and covers fabricated of fiber reinforced polymer (FRP). These larger FRP manhole <br />frame and cover sets shall be manufactured by GMI Composites, Inc., no equal. <br />The FRP frame and cover system shall meet the following requirements: contain 45 <br />percent to 70 percent fiber reinforcement; thermoset resin with UV inhibitors to prevent <br />photo degredation; minimum strength to weight ratio of 750:1; integrated gasket to <br />minimize traffic shock, abate noise and orders and prevent water entry into manhole; skid <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.