My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />159 <br />New submittals shall be required for material substitutions. The Engineer shall review <br />and upon approval notify the Contractor by a memorandum. <br />All fittings shall be pressure rated and classified the same as adjoining pipe. The inside <br />diameter shall match inside diameter of adjoining pipe and shall be designed for pipe <br />bursting or pipe jacking applications. <br />Metal in saddles, clamps and appurtenances shall be 302 or 304 stainless steel following <br />ASTM A240. <br />Elastomeric materials, gaskets, clamps and connectors shall be oil resistant and <br />manufactured following ASTM F477. <br />The Contractor shall submit certification by the manufacturer of the pipe bursting system <br />to have successfully completed training in operating the bursting head, installing <br />proposed replacement pipe and operation and maintenance of all equipment to be used. <br />The Contractor shall submit certification by the manufacturer of the fusing equipment <br />having successfully completed training in handling replacement of pipe materials, butt- <br />fusion of pipe joints and saddle fusion of fittings for service laterals, and operation and <br />maintenance of all equipment to be used. The Certificate of Training includes at a <br />minimum: Installer’s name, date of issuance and process or product the person/s is/are <br />certified to install. These certifications of training and operation of pipe bursting system <br />shall be submitted prior to commencing pipe bursting work. <br />The curb and gutter shall be protected in place. If the Contractor damages curb, gutter, it <br />shall be removed and replaced to match existing in accordance with City of Santa Ana <br />Standard Plan No. 1101. This work shall also include removal and replacement of PCC <br />sidewalk, driveway panels and landscaping to facilitate construction of sewer laterals. <br />PCC sidewalk and driveway approach panels shall be replaced to match existing in <br />accordance with City of Santa Ana Standard Plan Nos. 1104 and 1112. Sidewalk <br />replacement shall be from score line to score line, unless the sidewalk panels exceed four <br />feet in length. At no time, shall a sidewalk panel floater be less than four feet from the <br />nearest score line. Landscaping shall be replaced in-kind. <br />6.16 CONSTRUCT 4” OR 6” POLYVINYL CHLORIDE (PVC) SEWER LATERALS AND <br />CLEANOUTS (OPEN TRENCH) <br />PVC sewer pipe shall be as manufactured by JM EAGLE or approved equivalent. <br />PVC gravity sewer pipe and fittings shall conform to ASTM D3034 for diameters from <br />4" - 15", and ASTM F679 for 18" - 24", with integral bell gasket joints. Rubber gaskets <br />shall be factory installed and conform to ASTM F477. <br />Pipe shall be made of PVC plastic having a cell classification of 12454B or 12364B as <br />defined in ASTM D1784 and shall have SDR of 26 and minimum pipe stiffness of 115 <br />psi according to ASTM Test D2412. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.