My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />189 <br />Concrete shall be high early strength concrete, treated in accordance with section <br />201-1 to obtain (7) day compressive strength in (3) days. <br />The concrete shall be immediately protected upon its installation and no vehicular traffic <br />will be permitted thereon for the next (3) days. <br />7.15 WATER SERVICE <br />All work shall conform to City of Santa Ana Standard Plans and meet all AWWA <br />Specifications. <br />All ductile or cast iron pipe, fittings, valves, and appurtenances buried underground shall <br />be encased or wrapped with 10-mil linear low-density (LLD) polyethylene film. Any <br />existing or connecting pipe and appurtenances that are exposed as a result of this pipe <br />installation shall also be wrapped with polyethylene sheeting. <br />Service laterals shall be installed in a perpendicular direction to the centerline of the <br />water main. <br />Removal and replacement of sidewalk, driveway approach as necessary to facilitate water <br />service meter installation, shall be included as part of this work. All work shall conform <br />to City of Santa Ana Standard Nos. 1104, 1112, 1401, and 1402. <br />Sidewalk replacement shall be from score line to score line, unless the sidewalk panels <br />exceed four feet in length. At no time, shall a sidewalk panel floater be less than four feet <br />from the nearest score line. <br />The City shall furnish and install the water meter after all other work is complete. <br />Note: Angle meter stops are not acceptable. The connection to the meter coupling shall <br />be a curb stop with locking wing nut as noted on the Standard Plans. <br />For all water service relocations and installations, Contractor shall notify residents a <br />minimum of 48-hours prior to any interruption in service. Every effort shall be made to <br />minimize the inconvenience to the customer. Contractor shall coordinate these activities <br />with the City of Santa Ana Water Resources Division a minimum of four (5) working <br />days prior to beginning work on services. When necessary, such work shall be performed <br />after-hours or on weekends as directed by the Engineer. In no case shall any property be <br />without service for more than four (4) hours. In special circumstances, emergencies, or <br />when directed by the Engineer, Contractor shall provide temporary service lines to <br />prevent any interruption in service. All piping and associated equipment used in <br />temporary service connections shall be flushed and disinfected. All hoses shall be NSF <br />approved. <br />All fittings and appurtenances for water service and fire lines shall conform to AWWA <br />Standard C800 “Underground Service Line Valves and Fittings” and the California <br />Health and Safety Code 116875. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.