Laserfiche WebLink
(E) AC-14 <br />(E) AC-13 <br />HP-1 <br />160 CFM OA <br />585 CFM <br />OA <br />2 <br />1 <br />3 <br />4 <br />R 10' - 0" <br />5 <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />Consulting Engineer <br />www.alphamep.net <br />1/4" = 1'-0" <br />Issue Date <br />M201 <br />ROOF PLAN - <br />MECHANICAL <br />23-020-01 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />G E N E R A L N O T E S: <br />C O D E D N O T E S: <br />N02'4'8' <br />Scale: <br />1/4" = 1'-0"1ROOF PLAN - MECHANICAL <br />A. REFER SHEET M000 FOR GENERAL NOTES. <br />B.COORDINATE INSTALLATION OF NEW DUCT W/ STRUCTURE. <br />C.CONTRACTOR TO INSTALL ALL WORK IN STRICT COMPLIANCE WITH LOCAL CODES AND <br />ORDINANCES. <br />D.MECHANICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND EQUIPMENT <br />SUBMITTAL PRIOR TO INSTALLING OR FABRICATING ANY DUCTWORK. <br />E.ALL EXHAUST DUCT TERMINATIONS SHALL BE MAINTAINED 10 FEET AWAY FROM ANY <br />FRESH AIR INTAKES AND 3 FEET AWAY FROM ANY OPENING INTO THE BUILDING. <br />F.MECHANICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO RELOCATE <br />ANY PIPES, CONDUITS, DEVICES, OR THE STRUCTURES THAT CONFLICT WITH PROVIDING <br />A LARGER DUCT OPENING. <br />G.CONTRACTOR TO REMOVE INSULATION ON EXPOSED DUCTWORK IN OPEN CEILING AND <br />PAINT. <br />H.CONTRACTOR TO PROTECT EXISTING EQUIPMENT'S ASSOCIATED DUCTWORK, PIPING <br />AND VALVES DURING THE CONSTRUCTION. <br />1. FULL SIZE EXISTING SUPPLY AIR AND RETURN AIR DUCT DROPS DOWN TO FLOOR <br />BELOW FROM EXSITING ROOF MOUNTED AIR CONDITIONER UNIT (E) AC-13. <br />2.FULL SIZE EXISTING SUPPLY AIR AND RETURN AIR DUCT DROPS DOWN TO FLOOR <br />BELOW FROM EXSITING ROOF MOUNTED AIR CONDITIONER UNIT (E) AC-14. <br />3.6"Ø EXHAUST AIR DUCT UP TO ROOF FROM FLOOR BELOW AND TERMINATE ON THE <br />ROOF WITH WEATHER PROTECTIVE CAP, REFER SHEET M101 FOR EXACT DUCT UP <br />LOCATION. <br />4.CONTRACTOR TO ADJUST ECONOMIZER CONTROL POSITON TO RE BALACE OUTSIDE AIR <br />FLOW AS PER MENTIONED IN NEW WORK PLAN. <br />5.PROVIDE STEEL PLATFORM FOR CONDENSING UNIT ANCHORED TO ROOF STRUCTURE. <br />DESCRIPTION DATE <br />505 E Central Ave <br />#B11/6/2024