1. DETAILS OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS <br />THOSE SHOWN FOR SIMILAR CONDITIONS. REFER TO THE TYPICAL DETAIL <br />SHEETS FOR TYPICAL DETAILS OF CONSTRUCTION. TYPICAL DETAILS APPLY TO <br />ALL CONSTRUCTION UNLESS SPECIFICALLY NOTED OR SHOWN OTHERWISE. <br />WHERE CONDITIONS REQUIRE MODIFICATIONS OF A TYPICAL DETAIL, THE <br />CONTRACTOR SHALL SUBMIT MODIFIED DETAIL FOR APPROVAL BY THE <br />ENGINEER OF RECORD PRIOR TO FABRICATION AND INSTALLATION. DETAILS <br />OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS THOSE <br />SHOWN FOR SIMILAR CONSTRUCTION. <br /> <br />2. CONTRACTOR SHALL CONSIDER THE PROJECT SPECIFICATIONS A PART OF THE <br />CONTRACT DOCUMENTS. WHERE INFORMATION IS CONFLICTING, SPECIFIC <br />DETAILS SHALL GOVERN OVER TYPICAL DETAILS WHICH SHALL GOVERN OVER <br />THESE NOTES WHICH SHALL GOVERN OVER SPECIFICATIONS. <br />3. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST <br />ARCHITECTURAL DIMENSIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE <br />OMITTED OR NOT CLEAR, CONTACT THE ARCHITECT (ARCH) OR STRUCTURAL <br />ENGINEER OF RECORD (SEOR). ALL DIMENSIONS RELATED TO EXISTING <br />CONDITIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR. DIMENSIONS <br />ARE TO THE FACE OF STUDS, AND TO CENTERLINE OF COLUMNS UNO. <br />4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY THE SEOR <br />OF ANY CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND OTHER <br />DRAWINGS; OR EXISTING CONDITIONS NOT SHOWN OR DIFFERENT FROM <br />THOSE SHOWN ON DRAWINGS PRIOR TO COMMENCEMENT OF WORK. THE <br />CONTRACTOR IS NOT TO ORDER MATERIAL OR CONSTRUCT ANY PORTION OF <br />THE BUILDING THAT IS IN CONFLICT UNTIL THE CONFLICT IS RESOLVED WITH <br />THE AFFECTED PARTIES. <br />5. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE. UNLESS OTHERWISE SHOWN THEY DO NOT INDICATE METHOD OF <br />CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES <br />NECESSARY TO PROTECT THE CONSTRUCTION AND ALL ADJACENT <br />PROPERTIES DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT <br />ARE NOT LIMITED TO BRACING, SHORING OF LOADS DUE TO CONSTRUCTION <br />EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT OR <br />SEOR SHALL NOT INCLUDE OBSERVATION OF THE ABOVE ITEMS. <br />6. SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL <br />DRAWINGS MAY BE CONSIDERED WITH MATERIALS HAVING EQUIVALENT OR <br />GREATER CAPACITY AND PERFORMANCE. CURRENT EVALUATION REPORTS <br />AND PRODUCT INFORMATION SHALL BE PROVIDED TO THE STRUCTURAL <br />ENGINEER DEMONSTRATING THE REQUIRED CAPACITY AND PERFORMANCE OF <br />THE MATERIAL TO BE SUBSTITUTED. WRITTEN APPROVAL FROM THE SEOR <br />SHALL BE OBTAINED PRIOR TO THE SUBSTITUTION OF ANY MATERIAL <br />SPECIFIED ON THE STRUCTURAL DOCUMENTS. <br />7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT <br />SECTIONS OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE <br />OF CALIFORNIA, LATEST EDITION, AND ALL OSHA REQUIREMENTS AS THEY <br />APPLY TO THIS PROJECT. THE ARCHITECT, SEOR, AND THE OWNER DO NOT <br />ACCEPT ANY RESPONSIBILITY FOR THE CONTRACTOR'S FAILURE TO COMPLY <br />WITH THESE REQUIREMENTS. <br /> <br />8. ALL WORK IS NEW (N) UNLESS INDICATED AS EXISTING (E). <br />9. CONSTRUCTION MATERIALS SHALL BE DISTRIBUTED WHEN PLACED ON THE <br />STRUCTURE SUCH THAT LOADS DO NOT EXCEED DESIGN LIVE LOADS OR <br />RESULT IN AN UNBALANCED CONDITION. <br />10. REFER TO THE PROJECT SPECIFICATIONS FOR SHOP DRAWING <br />REQUIREMENTS AND SUBMITTALS. <br />GENERAL NOTES: <br />1. CODES: <br />ALL WORK SHALL BE IN CONFORMANCE WITH THE CALIFORNIA <br />BUILDING CODE (CBC) 2022 EDITION, INCLUDING ALL AMENDMENTS. <br /> ALL STANDARDS USED SHALL BE THE LATEST VERSION APPROVED <br />BY THE CODE ENFORCEMENT AGENCY ON THE DATE OF THE PERMIT <br />ISSUANCE UNLESS SPECIFICALLY NOTED OTHERWISE. <br />2. DESIGN LIVE LOAD <br /> <br />3. WIND DESIGN INFORMATION <br />4. SEISMIC DESIGN INFORMATION <br />STRUCTURAL DESIGN CRITERIA: <br />RISK CATEGORY = III Kd =0.85 Kzt = 1.0 <br />BASIC WIND SPEED V = 102 MPH (3 SEC GUST) EXPOSURE = C <br />INTERNAL PRESSURE COEFF. = +/- 0.18 <br />I = 1.25 RISK CATEGORY = III SITE CLASS = D (DEFAULT) <br />SS = 1.275 S1 = 0.457 SDS = 1.020 SD1 = 0.516 <br />SEISMIC DESIGN CATEGORY = D <br />LOAD <br />ROOF 20 PSF <br />TYPICAL ABBREVIATIONS <br />A.B.ANCHOR BOLT <br />INT INTERIOR <br />ABV ABOVE <br />ADDT'L ADDITIONAL <br />KLF KIPS PER LINEAR FOOT <br />ADJ ADJACENT <br />KSL KIPS PER SQUARE FOOT <br />A.F.F.ABOVE FINISH FLOOR <br />KSI KIPS PER SQUARE INCH <br />ALT ALTERNATE <br />L ANGLE <br />ARCH ARCHITECT(URAL)LFRS LATERAL FORCE <br />BLDG BUILDING <br />RESISTING SYSTEM <br />BLK'G BLOCKING <br />LLH LONG LEG HORIZONTAL <br />BLW BELOW <br />LLV LONG LEG VERTICAL <br />BM BEAM LP LOW POINT <br />BN BOUNDARY NAILING LWC LIGHTWEIGHT CONCRETE <br />B.O.BOTTOM OF MAX MAXIMUM <br />BOT BOTTOM M.B.MACHINE BOLT <br />BRG BEARING MECH MECHANICAL <br />B.S.BOTH SIDES MFR MANUFACTURER <br />BTWN BETWEEN MIN MINIMUM <br />C CAMBER OR MTL METAL <br />C.I.P.CAST IN PLACE <br />(N)NEW <br />CJ CONTROL/ NS NEAR SIDE OR NON-SHRINK <br />CONSTRUCTION JOINT NTS NOT TO SCALE <br />CL CENTERLINE NWC NORMAL WEIGHT CONCRETE <br />CLR CLEAR <br />O.C.ON CENTERCMUCONCRETE MASONRY UNIT <br />O.F.OUTSIDE FACECOLCOLUMN <br />OH OPPOSITE HANDCONCCONCRETE <br />OPM <br />OSHPD PRE APPROVAL OFCONN CONNECTION <br />PDF POWDER DRIVEN FASTENER <br />CONT CONTINUOUS <br />PJ PANEL JOIST <br />CP COMPLETE PENETRATION <br />PL PLATE <br />CSK COUNTERSINK <br />PLC(S) PLACE(S) <br />CTR(D) CENTER(ED) <br />PLF POUND PER LINEAR FOOT <br />DB BAR OR BOLT DIAMETER <br />PLYWD PLYWOOD <br />DBL DOUBLE <br />PREFAB PREFABRICATED <br />DC DEMAND CRITICAL <br />PSF POUND PER SQUARE FOOT <br />DEMO DEMOLITION <br />PSI POUND PER SQUARE INCH <br />DET DETAIL <br />PT PRESSURE TREATED OR <br />DIA DIAMETER <br />POST TENSION <br />DIAG DIAGONAL <br />QTY QUNATITY <br />DIM DIMENSION <br />RAD, R RADIUS <br />DO DITTO <br />REF REFERENCE <br />DWG DRAWING <br />REINF REINFORCING <br />(E) EXISITNG <br />REQ'D REQUIRED <br />EA EACH <br />SB SILL BOLT <br />E.F. EACH FACE <br />SC SAW CUT OR SLIP CRITICAL <br />EJ EXPANSION JOIST <br />SCHED SCHEDULE <br />EMBED EMBEDMENT <br />SEOR STRUCTURAL ENGINEER <br />ELEC ELECTRICAL <br />ON RECORD <br />ELEV ELEVATION <br />SHT'G SHEATHING <br />EN EDGE NAILING <br />SIM SIMILAR <br />E.O.EDGE OF <br />SLRS SEISMIC LOAD <br />EOR ENGINEER OF RECORD <br />RESISTING SYSTEM <br />EQ EQUAL <br />SMS SHEET METAL SCREW <br />EQUIP EQUIPMENT <br />SN SILL NAIL <br />E.S.EACH SIDE/ EDGE SCREW <br />S.O.G.SLAB ON GRADE <br />E.W.EACH WAY <br />SQ SQUARE <br />EXP EXPANSION <br />SS STAINLESS STEEL <br />EXT EXTERIOR <br />STD STANDARD <br />FIN FINISH <br />STAGG.STAGGERED <br />FLR FLOOR <br />SITFF STIFFENER <br />FN FIELD NAILING <br />STL STEEL <br />FND FOUNDATION <br />STRUCT STRUCTURAL <br />F.O. FACE OF <br />T&B TOP AND BOTTOM <br />FS FAR SIDE OR FIELD SCREW <br />THK THICK <br />FRM'G FRAMING <br />T.O. TOP OF <br />FT FOOT OR FEET <br />T.O.M.TOP OF MASONRY <br />FTG FOOTING <br />T.O.S.TOP OF STEEL <br />G GIRDER <br />TYP TYPICAL <br />GA GAUGE <br />U.N.O. UNLESS NOTED OTHERWISE <br />GALV GALVANIZED <br />VERT VERTICAL <br />H.A.B. HEADED ANCHOR BOLT <br />W/WITH <br />HD HOLDOWN <br />W/O WITHOUT <br />HDR HEADER <br />WF WIDE FLANGE/WALL FOOTING <br />HGR HANGER <br />WLD WELDED <br />HK HOOK <br />WO WHERE OCCURS <br />HORIZ HORIZONTAL <br />WP WORK POINT <br />HP HIGH POINT <br />WT WEIGHT <br />HS HIGH STRENGTH <br />WWF WELDED WIRE FABRIC <br />HSS HOLLOW STRUCTURAL <br />SECTION <br />REFERENCE ELEVATION OR <br />HT HEIGHT <br />WORK POINT <br />IN INCH <br />PENE PENETRATION <br />OPN'G OPENING <br />MANUFACTURER’S <br />CERTIFICATION <br />A.T.R. ALL THREADED ROD <br />LBS POUND <br />WWM WELDED WIRE MESH <br />GB GRADE BEAM <br />LONG. LONGITUDINAL <br />SF SPREAD FOOTING <br />TRANS. TRANSVERSE <br />LLBB LONG LEG BACK TO BACK <br />JST JOIST <br />PERF PERFORATED <br />NOM. NOMINAL <br />OD OUTSIDE DIAMETER <br />RJ ROOF JOIST <br />FJ FLOOR JOIST <br />C-CHANNEL <br />DIST DISTANCE <br />W.S.WELDED STUD <br />FN HT FINISH HEIGHT <br />⌀DIAMETER <br />FINISH SURFACE <br />R.O. ROUGH OPENING <br />S.A.D.SEE ARCHITECUTRAL DRAWINGS <br />FOUNDATION NOTES (NO SOILS REPORT): <br />1. NO SOILS REPORT AVAILABLE; THEREFORE, MINIMUM PRESUMPTIVE LOAD- <br />BEARING VALUES FOR CLASS OF MATERIALS 5 (CLAY, SANY CLAY, SILTY CLAY, <br />CLAYEY SILT, SILT AND SANDY SILT) ARE USED PER 2022 CBC. <br />2. ALLOWABLE VERTICAL BEARING PRESSURE = 1500 PSF <br />ALLOWABLE LATERAL BEARING PRESSURE = 100 PSF PER FT OF DEPTH <br />3. THE CONTRACTOR SHALL CONFORM TO ALL RECOMMENDATIONS AND <br />CONDITIONS INDICATED IN THE 2022 CBC. <br />4. WHERE THE BUILDING OFFICIAL HAS REASON TO DOUBT THE CLASSIFICATION, <br />STRENGTH OR COMPRESSIBILITY OF THE SOIL OR WHERE A LOAD-BEARING <br />VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BULIDNG <br />OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A GEOTECHNICAL <br />INVESTIGATION BE CONDUCTED. <br />5. PRESUMPTIVE LOAD-BEARING VALUES SHALL APPLY TO MATERIALS WITH <br />SIMILAR PHYSICAL CHARACTERISTICS AND DISPOSITIONS. <br />MUD, ORGANIC SILT, ORGANIC CLAYS, PEAT OR UNPREPARED FILL SHALL NOT <br />BE ASSUMED TO HAVE A PRESUMPTIVE LOAD-BEARING CAPACITY UNLESS <br />DATA TO SUBSTANIATE THE USE OF SUCH A VALUE ARE SUBMITTED. <br />- EXCEPTION: A PRESUMPTIVE LOAD-BEARING CAPACITY SHALL BE <br />PERMITTED TO BE USED WHERE THE BUILDING OFFICIAL DEEMS THE <br />LOAD-BEARING CAPACITY OF MUD, ORGANIC SILT OR UNPREPARED FILL IS <br />ADEQUATE FOR THE SUPPORT OF LIGHTWEIGHT OR TEMPORARY <br />STRUCTURES. <br />6. THE BOTTOM OF FOUNDATION SHALL BE CLEARED AND COMPACTED TO <br />90 PERCENT OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT <br />DETERMINED IN ACCORDANCE WITH ASTM D1557. <br />7. SPREAD FOOTINGS ARE CENTERED UNDER WALLS AND COLUMNS, UNO. <br />8. FOOTING ELEVATIONS ARE NOTED ON THE PLANS AND DETAILS AND SHALL BE <br />USED FOR BIDDING. IN ANY CASE, FOOTINGS SHALL BEAR ON FIRM <br />UNDISTURBED SOIL OR ENGINEERED FILL, IN ACCORDANCE WITH <br />THE 2022 CBC AND DETAILS SHOWN. <br />9. CONTRACTOR SHALL PROTECT ALL UTILITY LINES, ETC. ENCOUNTERED <br />DURING EXCAVATION AND BACKFILLING. <br />10. ALL EXCAVATION SHALL COMPLY WITH APPLICABLE OSHA REQUIREMENTS. <br />11. PRIOR TO REINFORCEMET FOR FOUNDATIONS BEING PLACED, THE <br />CONTRACTOR SHALL SUBMIT A REPORT INDICATES THE ITEMS 5, 6, 7, 8, 9 AND <br />10 ARE VERIFIED. <br />THE REPORT SHALL ALSO STATE THAT: <br />A. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE <br /> APPROVED CONSTRUCTION DOCUMENTS. <br />B. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND <br /> COMPACTED. <br />C. THE FOUNDATION EXCAVATIONS COMPLY WITH THE INTENT OF THE <br /> APPROVED CONSTRUCTION DOCUMENTS. <br />1. REINFORCING GRADES FOR CONCRETE OR MASONRY: <br /> <br />2. MAINTAIN MINIMUM CONCRETE COVER FROM FACE OF CONCRETE TO EDGE OF <br />ALL REINFORCEMENT AS FOLLOWS (U.N.O.): <br />(SEE PLAN/ SECTION FOR CONCRETE W/ FIRE RATING.) <br /> <br />PROVIDE THE LARGEST COVER REQUIRED FOR ALL APPLICABLE CONDITIONS. <br />WHERE #3 STIRRUPS OR TIES ARE USED, ENSURE THAT THE COVER FOR <br />LONGITUDINAL BARS IS ADEQUATE. <br />3. REINFORCEMENT SHALL BE PLACED IN ACCORDANCE WITH THE CONCRETE <br />REINFORCING STEEL INSTITUTE (CRSI) "MANUAL OF STANDARD PRACTICE". <br />EACH REINFORCING BAR SHALL BE WIRED TO A CROSS BAR AT A MAXIMUM <br />SPACING OF 24" O.C. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT <br />REINFORCING IN POSITIONS SHOWN ON THE PLANS. <br />4. SPLICES IN CONTINUOUS REINFORCEMENT AS USED IN W ALLS, FOOTINGS, <br />SLABS, ETC., SHALL HAVE A CLASS "B" LAP (1' - 6" MIN) AND THE SPLICES IN <br />ADJACENT BARS SHALL BE NOT LESS THAN 5' - 0" APART. VERTICAL WALL BARS <br />SHALL BE SPLICED AT OR NEAR FLOOR LINES. BARS MAY BE WIRED <br />TOGETHER AT SPLICES OR LAPS EXCEPT FOR TOP REINFORCING OF BEAMS <br />AND SLABS OR WHERE SPECIFICALLY DETAILED TO BE SEPARATED. WELDED <br />WIRE FABRIC SHALL BE LAPPED 12" MINIMUM. <br />5. ALL DOWELS, ANCHOR BOLTS AND OTHER HARDWARE TO BE SET IN <br />CONCRETE SHALL BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO <br />WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED <br />ITEMS SHALL BE PERFORMED DURING PLACEMENT OF CONCRETE. <br />6. BEND REINFORCING BARS COLD. <br />7. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST. <br />8. DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME <br />GRADE, SIZE AND SPACING AS THE MAIN REINFORCING U.N.O. <br /> <br />9. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN <br />THE FINAL IN PLACE INSPECTION IS MADE. <br />10. CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC <br />COATED WHEN RESTING ON EXPOSED SURFACES. <br />REINFORCING STEEL NOTES: <br />ALL BARS EXCEPT THOSE TO BE WELDED <br />TIES AND STIRRUPS <br />WELDED WIRE FABRIC <br />ALL BARS TO BE WELDED <br />ALL BARS IN THE CONCRETE SHEARWALL <br />INDICATED ON WALL ELEVATION INCLUDING <br />SUPPORTING WALL FOOTING LONGITUDINAL <br />BARS (WF), AND ALL GRADE BEAMS (GB) <br />ASTM A615, GRADE 60 <br />ASTM A615, GRADE 60 <br />ASTM A1064 <br />ASTM A706, GRADE 60 <br />A706, GRADE 60 <br />CONDITION <br />CONCRETE POURED AGAINST EARTH <br />CONCRETE POURED IN FORMS AND <br />EXPOSED TO WEATHER OR EARTH <br />-#6 BARS AND LARGER <br />-#5 BARS AND SMALLER <br />INTERIOR COLUMNS AND BEAMS <br />INTERIOR WALL FACES AND RAISED SLABS <br />STRUCTURAL SLABS ON GRADE <br />-FROM BOTTOM OF SLAB <br />-FROM TOP OF SLAB <br />OTHER CONCRETE NOT EXPOSED TO WEATHER OR <br />EARTH FOR #11 BARS AND SMALLER <br />COVER <br />3" <br />2" <br />1 1/2" <br />1" <br />1" <br />2" <br />1 1/2" <br />1 1/2" <br />1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL <br />CONFORM TO THE SPECIFICATIONS AND STANDARD OF THE AMERICAN <br />INSTITUTE OF STEEL CONSTRUCTION (AISC), AS CONTAINED IN THE 15TH <br />EDITION OF "AISC MANUAL OF STEEL CONSTRUCTION". <br /> <br />2. ALL STRUCTURAL STEEL SHALL BE ERECTED PLUMB AND TRUE TO LINE. <br />TEMPORARY BRACING SHALL BE INSTALLED AND SHALL BE LEFT IN PLACE <br />UNTIL OTHER MEANS IS PROVIDED TO ADEQUATELY BRACE THE STRUCTURE. <br />3. PROVIDE THE FOLLOWING MATERIALS FOR STRUCTURAL STEEL U.N.O.: <br /> <br /> <br />4. 1/8" THICK PLATES AND THICKER SHALL BE GAS CUT OR SAW CUT <br />EXCEPT AS OTHERWISE NOTED, ALL BOLTS SHALL BE HIGH STRENGTH BOLTS. <br />EXCEPT OTHERWISE NOTED, ALL BOLT HOLES SHALL BE STANDARD HOLES. <br />5. ALL CONNECTIONS NOT SHOWN SHALL CONFORM TO THE "AISC MANUAL OF <br />STEEL CONSTRUCTION" AND SHALL BE SUBMITTED ON SHOP DRAWINGS FOR <br />REVIEW BY SEOR PRIOR TO FABRICATION. <br />6. ALL WELDED HEADED STUDS, THREADED STUDS, AND DEFORMED BARS SHALL <br />BE NELSON, OR EQUIVALENT, AND WELDED (IN ACCORDANCE WITH <br />MANUFACTURER'S RECOMMENDATIONS BY CERTIFIED WELDERS) SO AS TO <br />FULLY DEVELOP THE TENSILE CAPACITY OF THE CONNECTOR. <br />7. BOLTS WITH UPSET THREADS ARE NOT ALLOWED. USE THE APPROPRIATE NUT <br />AND WASHER TYPE FOR THE SPECIFIED BOLT. <br />8. ALL STEEL FABRICATION SHALL BE PERFORMED BY A AISC OR CITY OF LOS <br />ANGELES CERIFIED FABRICATOR. <br />9. ALL STRUCTURAL STEEL AND MISCELLANEOUS STEEL PERMANENTLY EXPOSED <br />TO THE ELEMENTS SHALL BE HOT DIP GALVANIZED AFTER FABRICATION <br />UNLESS A WEATHER PROOF COATING IS SPECIFIED BY THE ARCHITECT U.N.O. <br />STAINLESS AND WEATHERING STEELS ARE EXCEPTED WHERE SPECIFIED. <br />10. SEE ARCHITECTURAL DRAWINGS FOR NAILER HOLES, WELDED STUDS OR <br />OTHER ITEMS NOT SHOWN IN THESE DRAWINGS. WHERE STEEL IS EMBEDDED <br />IN CONCRETE OR MASONRY, PROVIDE HOLES AS REQUIRED FOR PASSAGE OF <br />CONTINUOUS REINFORCING BARS WHERE INDICATED ON DRAW INGS. DO NOT <br />CUT HOLES IN STRUCTURAL STEEL WITHOUT PRIOR APPROVAL OF SEOR. <br />11. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL COMPLY <br />WITH AISC CODE OF STANDARD PRACTICE, SECTION 10. <br />12. PLACE NON-SHRINK OR DRYPACK GROUT UNDER ALL BASE PLATES AND <br />ALLOW TO CURE BEFORE APPLYING LOADS. <br />13. ALL OPEN HSS ENDS SHALL BE CAPPED. MIN 1/4" STEEL CAP. PROVIDE SQUARE <br />WELD ALL AROUND, CAP PLATE TO HSS. <br />14. FOR STRUCTURAL STEEL, IN ADDITION TO THE REQUIREMENTS OF <br />SPECIFICATION SECTION A3.1c, HOT ROLLED SHAPES WITH FLANGES 1 1/2" <br />THICK AND THICKER SHALL HAVE MINIMUM CHARPY V-NOTCH TOUGHNESS OF <br />20 FT-LB AT 70°F. PLATES 2" THICK AND THICKER SHALL HAVE A MINIMUM <br />CHARPY V-NOTCH TOUGHNESS OF 20FT-LB AT 70°F. <br />STRUCTURAL STEEL NOTES: <br />STRUCTURAL STEEL GRADES: <br />ALL WIDE FLANGE SECTIONS <br />SQUARE OR RECTANGULAR HOLLOW <br />STRUCTURAL SECTIONS (HSS) <br />ROUND HOLLOW STRUCTURAL SECTION <br />(HSS) <br />PIPES <br />PLATES, ANGLES, CHANNELS & TEES <br />ALL PLATES PART OF SLRS <br />MACHINE BOLTS (MB) <br />HIGH STRENGTH BOLTS (HSB) <br />WELDED HEADED STUDS <br />THREADED RODS FOR ANCHOR BOLTS <br />ASTM A992 <br />ASTM A500, GRADE C <br />(FY= 50 KSI) <br />ASTM A500,GRADE C <br />(FY= 46KSI) <br />ASTM A53 TYPE E OR S, <br />GRADE B (FY=35 KSI) <br />ASTM A36 <br />ASTM A572, GRADE 50 <br />ASTM A307 <br />ASTM F3125 GRADE A325 <br />GRADE A490 <br />ASTM A29 <br />ASTM F1554, GRADE 36 <br />A. <br />B. <br />C. <br />C. <br />E. <br />F. <br />G. <br />H. <br />I. <br />J. <br />1. SEE STRUCTURAL STEEL NOTES THIS SHEET FOR ADDITIONAL <br />INFORMATION. <br />2. ALL HIGH-STRENGTH BOLTS SHALL CONFORM TO ASTM F-3125 Gr. A-325 <br />OR Gr. A-490, NUTS SHALL CONFORM TO ASTM A-563 AND WASHERS SHALL <br />CONFORM TO ASTM F-436. <br />3. HIGH STRENGTH BOLTS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />CURRENT EDITION OF THE "AISC SPECIFICATION FOR STRUCTURAL JOINTS <br />USING HIGH-STRENGTH BOLTS". SLIP CRITICAL BOLTS (SC) SHALL BE <br />USED FOR ALL "SEISMIC LOAD RESISTING SYSTEM" (SLRS) MEMBER STEEL- <br />TO-STEEL CONNECTIONS. <br />4. PAINT SHALL NOT BE PERMITTED ON CONTACT SURFACES UNLESS NOTED <br />OTHERWISE. CONTACT SURFACES OF BOLTED PARTS SHALL BE <br />DESCALED AND FREE OF DIRT, OIL, BURRS, PITS, AND OTHER DEFECTS <br />WHICH PREVENT SOLID SEATING OF PARTS. <br />5. FAYING SURFACE SHALL BE "CLASS A" FOR SLIP CRITICAL BOLTS (SC). <br />6. SLIP-CRITICAL JOINT ASSEMBLIES SHALL BE FULLY PRE-TENSIONED BY <br />TURN-OF-NUT TIGHTENING, CALIBRATED WRENCH TIGHTENING, <br />INSTALLATION OF ALTERNATE DESIGN BOLTS OR BY DIRECT TENSION <br />INDICATOR TIGHTENING. <br />HIGH-STRENGTH BOLT NOTES: <br />1. WELDING PROCEDURES, ELECTRODES AND WELDER QUALIFICATIONS SHALL <br />CONFORM TO THE "CODE FOR WELDING IN BUILDING CONSTRUCTION", <br />AMERICAN WELDING SOCIETY (AWS), D1.1, D1.8 AND THE AISC <br />"SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF <br />STRUCTURAL STEEL FOR BUILDINGS". <br />2. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AWS STANDARD <br />QUALIFICATION TESTS, AND SHALL BE CERTIFIED FOR THE WORK THEY ARE <br />PERFORMING. <br />3. PROJECT WELDING SHALL BE PERFORMED ONLY IN ACCORDANCE WITH <br />WELDING PROCEDURE SPECIFICATIONS (WPS) SUBMITTED BY THE <br />CONTRACTOR AND REVIEWED BY THE SEOR AND PROJECT WELDING <br />INSPECTOR. THE WPS SHALL BE IN ACCORDANCE WITH AWS D1.1-D1.4 & D1.8 <br />CURRENT EDITION. <br />4. ALL WELDS WITHIN MEMBERS DESIGNATED AS PART OF THE SEISMIC LOAD <br />RESISTING SYSTEM (SLRS) SHALL CONFORM TO THE DETAILING, MATERIALS, <br />WORKMANSHIP, TESTING, AND INSPECTION REQUIREMENTS PER AWS D1.8 <br />AND MUST HAVE A MIN. CVN TOUGHNESS OF 20 FT-LB @ 0°F PER AISC 341 <br />A3.4B. <br />5. WHERE WELDS ARE DESIGNATED AS DEMAND CRITICAL, THEY SHALL BE MADE <br />WITH A FILLER METAL CAPABLE OF PROVIDING A MINIMUM CHARPY V-NOTCH <br />(CVN) TOUGHNESS OF 20 FT-LB AT 0°F AND 40 FT-LB AT 70°F. SEE AISC 341-16 <br />SECTION A3.4B FOR ADDITIONAL REQUIREMENTS. <br />6. WELDING OF STRUCTURAL STEEL SHALL BE PERFORMED PER AWS D1.1 & D1.8 <br />USING E70XX ELECTRODES UNLESS OTHERWISED NOTED. <br />7. WELDING OF REINFORCING BARS SHALL BE PERFORMED PER AWS D1.4 USING <br />E80XX ELECTRODES. <br />8. WELDING OF METAL DECK AND LIGHT GAGE STEEL SHALL BE IN ACCORDANCE <br />WITH AWS D1.3. <br />9. ALL GROOVE OR BUTT WELDS SHALL BE COMPLETE PENETRATION WELDS. <br />ALL EXPOSED BUTT WELDS SHALL BE GROUND SMOOTH. <br />10. ALL EXPOSED WELDS ON ARCHITECTURALLY EXPOSED STRUCTURAL STEEL <br />(AESS) SHALL COMPLY WITH AISC CODE OF STANDARD PRACTICE, SECTION 10. <br />11. FIELD WELDS HAVE BEEN INDICATED WHERE THEY ARE EXPECTED TO OCCUR. <br />THE CONTRACTOR SHALL DETERMINE THE ACTUAL FIELD WELDING <br />NECESSARY TO COMPLETE THE PROJECT AND INCLUDE ALL ASSOCIATED <br />COSTS WITHIN THE BASE BID. <br />12. ALL WELDS (SHOP AND FIELD) REQUIRE SPECIAL INSPECTION. <br />13. ALL FULL PENETRATION WELDS SHALL BE ULTRA-SONIC TESTED PER AWS D1.1 <br />& AISC 341 J6.2. <br />WELDING NOTES: <br />E N G I N E E R S I N CV C A <br />2151 Michelson Dr. #240 <br />Irvine, CA 92612 <br />Tel. 949.679.0870 <br />Fax. 949.679.9370 <br />Project No.: J804 <br />C I V I LQuality <br />Service <br />Commitment <br />S T R U C T U R A L DBEMBE SBE <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />DATE ISSUED: <br />PROJECT NO: <br />12" = 1'-0" <br />Issue Date <br />S-0.1 <br />GENERAL NOTES <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />CI <br />T <br />Y <br />, <br /> <br />S <br />T <br />A <br />T <br />E <br /> <br />Z <br />I <br />P <br /> <br />C <br />O <br />D <br />E <br />DESCRIPTION DATE <br />7/08/24 <br />505 E Central Ave <br />#B11/6/2024