Laserfiche WebLink
1. ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. <br />2. DOUGLAS FIR (DF) SHALL BE GRADED BY THE WESTERN WOOD PRODUCTS <br />ASSOCIATION GRADING RULES, AND ASTM D245. <br />3. REDWOOD SHALL BE GRADED BY THE CALIFORNIA REDWOOD ASSOCIATION, <br />REDWOOD INSPECTION SERVICE. <br />4. SILL PLATES SHALL BE PRESSURE-TREATED (PT) DOUGLAS FIR #1. REDWOOD <br />IS PERMITTED WITH SEOR APPROVAL. <br />5. TOP PLATES, SILL PLATES, STUDS SHALL BE....................................DF #1 <br />JOISTS, RAFTERS, PURLINS, BEAMS & POSTS SHALL BE ................DF #1 (U.N.O.) <br />LOAD BEARING STUDS SHALL BE.........................................................DF #1 <br />6. MOISTURE CONTENT OF SAWN LUMBER SHALL NOT EXCEED 18% WHEN <br />FRAMING STARTS OR SHEATHING IS APPLIED. ANY NONCOMPLIANT WORK <br />SHALL BE REJECTED AND REFRAMED WITH ACCEPTABLE LUMBER. <br />7. TIMBERS 4" NOMINAL IN THE LEAST DIMENSION SHALL NOT CONTAIN BOXED <br />HEART. <br />8. SILL PLATES SHALL BE PRESSURE-TREATED AND SHALL BE BOLTED TO <br />CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS AT 48" O.C. MAX, U.N.O. WITH A <br />BOLT BETWEEN 4" TO 12" FROM THE END OF EACH PIECE OF SILL (2 BOLTS MIN <br />EACH PIECE). PIECE OF SILL SHALL BE CONSIDERED ENDED WHERE PLATE IS <br />CUT OUT OVER ONE-THIRD OF CROSS-SECTION. <br />9. ANCHOR BOLTS FOR STRUCTURAL WALLS SHALL HAVE 12" EMBEDMENT <br />(U.N.O.) <br />MEASURED FROM TOP OF SLAB. <br />10. STUD BEARING WALLS AND PARTITIONS SHALL HAVE DOUBLE TOP PLATES <br />LAPPED AT WALL AND PARTITION INTERSECTIONS. JOINTS IN UPPER AND <br />LOWER MEMBERS OF DOUBLE TOP PLATES SHALL BE STAGGERED AT LEAST <br />4' - 0". <br />11. HOLES IN WOOD AND STEEL MEMBERS FOR BOLTS SHALL BE THE NOMINAL <br />BOLT DIAMETER PLUS 1/16". <br />12. ALL BOLTS IN WOOD SHALL BE ASTM A307 STANDARD BOLTS, U.N.O. BOLTS <br />AND SCREWS SHALL BE TIGHTENED AT TIME OF ERECTION AND RETIGHTENED <br />BEFORE CLOSING IN OR AT THE COMPLETION OF THE JOB. <br />13. HOLES IN WOOD FOR LAG SCREW SHANK SHALL BE BORED TO THE SAME <br />DIAMETER AND DEPTH AS THE SHANK, AND FOR THE THREADED PORTION <br />BORED WITH A BIT NOT LARGER THAN 40% TO 70% OF THE SHANK DIAMETER. <br />14. LAG SCREWS AND SCREWS SHALL BE SCREWED AND NOT DRIVEN INTO PLACE. <br />BOLT HOLES SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM 1/16" LARGER THAN <br />THE BOLT DIAMETER. HOLES SHALL BE ACCURATELY ALIGNED IN MAIN <br />MEMBERS AND SIDE PLATES. BOLTS SHALL NOT BE FORCIBLY DRIVEN. <br />15. METAL FRAMING CONNECTORS SHALL BE MANUFACTURED BY SIMPSON <br />STRONG TIE COMPANY (CURRENT CATALOG), OR "USP" WITH EQUIVALENT ICC <br />PUBLISHED VALUES AND SHALL BE INSTALLED PER SPECIFICATIONS, NO <br />EXCEPTIONS. <br />16. INSTALL WINDOWS AND DOORS IN STUD WALLS AFTER DEAD LOADS ARE <br />APPLIED, AND PROVIDE A 1/2" SHIM SPACE AT THE HEAD CONDITION. <br />17. STEEL WASHERS SHALL BE PROVIDED UNDER HEADS AND NUTS OF ALL BOLTS <br />AND LAG SCREWS WHICH BEAR ON WOOD. STANDARD CUT WASHERS MAY BE <br />USED IN ALL CASES EXCEPT SILL PLATES AND WOOD LEDGERS AGAINST <br />CONCRETE OR MASONRY. NOTE, WASHERS UNDER CARRIAGE BOLT HEADS <br />SHALL BE LARGE ENOUGH TO ALLOW FOR SQUARE SHOULDERS. <br />18. ONLY LOAD BEARING AND/OR SHEAR WALLS ARE SHOWN <br />SEE ARCHITECTURAL DRAWINGS FOR ALL OTHER PARTITIONS. <br />19. ELEVATIONS SHOWN ON PLANS ARE FROM FINISHED FIRST FLOOR, DATUM <br />ELEVATION = 0' - 0". <br />20. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS ARE 2x6 STUDS <br />@ 16" O.C. TYPICAL, U.N.O. <br />21. ALL EXTERIOR STUD WALLS SHALL BE COMPLETELY SHEATHED WITH 15/32" <br />APA RATED SHEATHING, EXPOSURE-1 (32/16). <br />22. INTERIOR STRUCTURAL SHEATHED WALLS ARE SHOWN ON PLANS AND SHALL <br />HAVE 15/32" APA RATED SHEATHING EXPOSURE-1, (32/16),TYPICAL U.N.O. <br />23. ALL STRUCTURAL WALL SHEATHING IS SPLICED ON 2" NOMINAL BLOCKING AT <br />HORIZONTAL JOINTS, U.N.O. <br />24. STRUCTURAL FLOOR AND ROOF SHEATHING SHALL BE AS ON PLAN AND SHALL <br />BE APA RATED SHEATHING (32/16). <br />NOTE: 1/8" GAP SHALL BE PROVIDED BETWEEN ADJACENT PANELS. PANELS <br />WITH GRADE STAMP INDICATION "SIZED FOR SPACING" MAY BE USED TO <br />FACILITATE THIS REQUIREMENT. SEE PLANS FOR REQUIRED BOUNDARY AND <br />EDGE NAILING NOT LISTED BELOW. FLOOR SHEATHING SHALL BE GLUED AND <br />NAILED PER PLAN. <br />( * - SHEATHING @ EXTERIOR DECKS SHALL BE EXTERIOR RATED PLYWOOD.) <br />BN = BOUNDARY NAILING <br />EN = EDGE NAILING <br />FN = FIELD NAILING <br />25. SEE PLANS FOR LOCATION OF NOMINAL 2X FLAT BLOCKING AT ROOF <br />SHEATHING PANEL JOINTS. SEE THIS SHEET FOR PLY CLIP REQUIREMENTS AT <br />UNBLOCKED ROOF PANEL JOINTS. T&G SHEATHING IS NOT REQUIRED WHERE <br />JOINTS ARE BLOCKED. <br />26. (S) INDICATES METAL FRAMING CONNECTORS MANUFACTURED BY SIMPSON <br />STRONG TIE COMPANY (CURRENT CATALOG) OR "USP" WITH EQUIVALENT ICC <br />PUBLISHED VALUES AND SHALL BE INSTALLED PER SPECIFICATIONS, NO <br />EXCEPTIONS. <br />27. FASTENERS, INCLUDING NAILS, NUTS AND WASHERS, IN CONTACT WITH <br />PRESERVATIVE - TREATED WOOD SHALL BE OF HOT-DIPPED ZINC COATED <br />GALVANIZED STEEL OR STAINLESS STEEL. <br />ROUGH CARPENTRY/ WOOD NOTES:POST INSTALLED ANCHORS NOTES: <br />1. POST-INSTALLED ANCHORS SHALL BE INSTALLED BY QUALIFIED PERSONNEL <br />PER THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII). <br />2. THE TYPE, DIAMETER, AND EMBEDMENT SHALL BE AS NOTED ON THE <br />DRAWINGS (OR EQUAL). ALL POST-INSTALLED ANCHORS SHALL HAVE A <br />CURRENT CODE REPORT (ICC ESR, IAPMO ER, LARR, ETC.) <br />3. INSTALLATION OF ALL ANCHORS SHALL BE IN ACCORDANCE WITH THE <br />APPLICABLE CODE REPORT AND THE MPII. <br />4. HOLE FOR ANCHORS SHALL SIZED ACCORDING TO THE ANCHOR TYPE AND <br />DIAMETER PER THE MPII/CODE REPORT. HOLE SHALL BE DRILLED USING A <br />ROTARY HAMMER OR OTHER ACCEPTABLE METHOD DESCRIBED IN THE <br />MPII/CODE REPORT. <br />5. WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN <br />EXISTING NON-PRESTRESSED REINFORCED CONCRETE, LOCATE EXISTING <br />REINFORCEMENT BY NON-DESTRUCTIVE MEANS AND DO NOT CUT OR <br />DAMAGING THE EXISTING REINFORCING BARS. WHEN INSTALLING THEM INTO <br />EXISTING PRESTRESSED CONCRETE (PRE- OR POST- TENSIONED) LOCATE THE <br />PRESTRESSED TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO <br />INSTALLATION. EXERCISE EXTREME CARE AND CAUTION TO AVOID CUTTING <br />OR DAMAGING THE TENDONS DURING INSTALLATION. MAINTAIN A MINIMUM <br />CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED- <br />IN ANCHOR AND/OR PIN. <br />6. ALL MISSDRILLED/DEFFECTIVE HOLES SHALL BE ABANDONED AND SOLID <br />GROUTED. <br />7. PROVIDE SPECIAL INSPECTIONS AS LISTED IN THE CODE REPORT AND AS <br />REQUIRED BY CBC CHAPTER 17 AND ACI 318 SECTION 17.8.2. <br />1. FOR ALL ITEMS ON THE CONSTRUCTION DOCUMENTS NOT NOTED WITH A <br />SPECIFIC PRODUCT TYPE OR MANUFACTURER, THE CONTRACTOR SHALL <br />PROVIDE THE PRODUCT SPECIFIED IN THE TABLE BELOW. <br />2. THE FOLLOWING PRODUCTS SHALL BE INSTALLED PER THE REQUIREMENTS OF <br />THE REFERENCED PRODUCT APPROVALS BELOW, U.N.O. <br />3. AT CONTRACTOR'S OPTION, PRODUCTS MAY BE SUBSTITUTED FOR LIKE <br />PRODUCTS PER THE SCHEDULE BELOW IF APPROVED BY SEOR. <br />PRODUCT APPROVALS: <br />ITEM APPROVED PRODUCTS ICC# <br />EXPANSION <br />ANCHOR TO <br />CONCRETE <br />HILTI KWIK BOLT -TZ-2 ESR-4266 <br />ESR-2502 <br />ESR-3037SIMPSON STRONG-BOLT-2 <br />DEWALT POWER STUD+ SD2 <br />IAPMO ER <br />EXPANSION <br />ANCHOR TO <br />MASONRY <br />HILTI KWIK BOLT 3 ESR-1385 <br />ESR-2966 <br />SIMPSON STRONG-BOLT 2 <br />DEWALT POWER STUD+ SD1 <br />ER-0240 <br />SCREW <br />ANCHOR TO <br />CONCRETE <br />SIMPSON TITEN HD SCREW ANCHOR ESR-2713 <br />ESR-3889 <br />ESR-3027HILTI KH-EZ <br />DEWALT SCREW-BOLT+ <br />SCREW <br />ANCHOR TO <br />MASONRY <br />SIMPSON TITEN HD SCREW ANCHOR ESR-1056 <br />ESR-4042 <br />ESR-3056HILTI KH-EZ <br />DEWALT SCREW-BOLT+ <br />EPOXY <br />ANCHOR TO <br />CONCRETE <br />HILTI HIT-HY 200 <br />ESR-3298 <br />ESR-2508SIMPSON SET-XP <br />DEWALT PURE 110+ <br />EPOXY <br />ANCHOR TO <br />MASONRY <br />HILTI HIT-HY 200 ESR-3963 <br />ESR-3200 <br />-SIMPSON SET-XP <br />DEWALT AC100+ GOLD <br />ER-0265 <br />SHOTPIN <br />HILTI LOW-VELOCTIY X-U <br />UNIVERSAL POWER-DRIVEN <br />ESR-2269 <br />ESR-1799 <br />ESR-2138SIMPSON POWER-DRIVEN <br />RAMSET POWER-DRIVEN <br />SHEET <br />METAL <br />SCREW <br />HILTI KWIK-PRO SDS ESR-2196 <br />ESR-2907 <br />ESR-3332DRIL-FLEX SDS <br />NELSON BAR ANCHORS/STUDWELD STUD <br />/ANCHORS <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />ESR-3187 <br />ESR-1408PRO-TWIST SELF-DRILL SCREW - <br />1. CONCRETE SHALL BE MIXED, PLACED AND CURED IN ACCORDANCE WITH ACI <br />318, 2019 EDITION, AND PROJECT SPECIFICATIONS. <br />2. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN <br />WALLS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. IN SUCH CASES, <br />HOPPERS AND VERTICAL CHUTES OR TRUNKS SHALL BE USED. CHUTES OR <br />TRUNKS SHALL BE OF VARIABLE LENGTHS SO THAT FREE UNCONFINED FALL <br />OF CONCRETE SHALL NOT EXCEED SIX FEET. A SUFFICIENT NUMBER OF <br />CHUTES OR TRUNKS SHALL BE USED TO ENSURE THE CONCRETE IS KEPT <br />LEVEL AT ALL TIMES. <br />3. CONSTRUCTION JOINTS SHALL BE CLEANED AND ROUGHENED BY REMOVING <br />THE ENTIRE SURFACE TO EXPOSE CLEAN AGGREGATE SOLIDLY EMBEDDED IN <br />THE MORTAR MATRIX. SLUSH WITH A COAT OF NEAT CEMENT BEFORE <br />PLACING CONCRETE. SEE PLANS AND DETAILS FOR LOCATION AND TYPE OF <br />CONSTRUCTION JOINT. LOCATIONS OF ADDITIONAL CONSTRUCTION JOINTS <br />NOT SHOWN ON THESE PLANS SHALL BE SUBMITTED FOR APPROVAL BY THE <br />EOR PRIOR TO PLACING ANY CONCRETE. <br />4. STRUCTURAL CONCRETE SHALL MEET THE FOLLOWING DESIGN CRITERIA: <br /> <br /> <br />a. MAXIMUM DRY WEIGHT OF LIGHTWEIGHT CONCRETE SHALL BE <br /> 110 PCF . <br />b. SLUMP MEASURED PRIOR TO SUPERPLASTICIZER, WHERE OCCURS. <br />5. CONCRETE MIX DESIGN AND TESTING SHALL MEET THE REQUIREMENTS OF <br />THE BUILDING CODE, AND SPECIFICATIONS. ALL CONCRETE MIXES SHALL BE <br />DESIGNED BY A RECOGNIZED TESTING LAB STAMPED AND SEALED BY A <br />LICENSED CALIFORNIA CIVIL ENGINEER AND SUBMITTED TO THE SEOR FOR <br />REVIEW PRIOR TO CONCRETE PLACEMENT. STRUCTURAL CONCRETE MIXES <br />SHALL CONSIST OF 5 SACK MINIMUM U.N.O. <br />6. AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33 <br />(HARDROCK). AGGREGATES IN LIGHT WEIGHT CONCRETE SHALL CONFORM <br />TO ASTM C-330. <br />7. COMPRESSIVE STRENGTH TEST REPORTS SHALL BE SUBMITTED TO THE <br />BUILDING DEPARTMENT AND THE SEOR. <br />8. PORTLAND CEMENT SHALL BE AS NOTED ABOVE FOR ALL CONCRETE <br />CONFORMING TO ASTM C150, LOW ALKALI. MILL TESTS WITH CERTIFICATES <br />OF COMPLIANCE SHALL BE SUBMITTED. <br />9. FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS N OR F <br />MAY BE USED AS A PARTIAL SUBSTITUTION FOR PORTLAND CEMENT UP TO A <br />MAXIMUM OF 15% TOTAL CEMENTITIOUS MATERIALS BY WEIGHT IF THE MIX <br />DESIGN IS PROPORTIONED PER ACI 318, SECTION 26.4.3. <br />10. CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94. <br />11. LEAN CONCRETE, WHERE SPECIFICALLY INDICATED, SHALL CONTAIN 2 SACKS <br />OF CEMENT PER CUBIC YARD OF CONCRETE. <br />12. DRYPACK OR NONSHRINK GROUT SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2 TIMES THE SUPPORTING CONCRETE <br />STRENGTH, AND SHALL BE OF FIVE STAR GROUT, SIKA GROUT 212, OR <br />APPROVED EQUAL WITH VALID CODE REPORT (LARR,ICC,ESR,IAPMO ER). <br />FOR THICK GROUT LAYERS FOLLOW MANUFACTURER'S GUIDELINES TO <br />ATTAIN THE REQUIRED STRENGTH, WHICH MAY INCLUDE THE ADDITION OF <br />PEA GRAVEL. <br />13. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER <br />USED IN MIX SHALL BE CLEAN AND POTABLE. <br />14. PRIOR TO ERECTING ANY ELEMENTS THAT LOAD THE FOUNDATION, <br />CONCRETE MUST REACH AN UNCONFINED COMPRESSION STRENGTH OF 2000 <br />PSI MINIMUM AS DETERMINED BY TESTING OR PREVIOUSLY DOCUMENTED <br />DATA FOR THE MIX DESIGN USED UNDER SIMILAR CONDITIONS, AND MUST BE <br />ALLOWED TO CURE FOR A MINIMUM OF 3 DAYS. <br />15. FOR INTERIOR SLABS-ON-GRADE AND ALL OTHER SLABS RECEIVING ADHERED <br />FLOORING FINISHES (I.E., GLUED, ETC.), THE MAXIMUM W/C RATIO SHALL NOT <br />EXCEED 0.45. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECIEVE <br />FINISHES SHALL BE COMPATIBLE WITH TILE AND ADHESIVES OR GROUTS IN <br />ACCORDANCE WITH MANUFACTURER'S DATA AND BE APPROVED BEFORE <br />USE. <br />16. MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST <br />CONDITION FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT UNLESS <br />OTHERWISE ACCEPTED BY SEOR. <br />17. SEE ARCHITECTURAL DRAWINGS FOR WALL OPENINGS, W ALL OFFSETS, <br />CHAMFERS, KERFS, DRIPS AND FOR EXTENT OF DEPRESSIONS, RAMPS, ETC. <br />PROVIDE SLEEVES FOR ALL PIPES THROUGH CONCRETE WALLS AND <br />FOOTINGS WHERE SHOWN ON THESE DRAWINGS. CORING IS NOT PERMITTED <br />WITHOUT PRIOR APPROVAL BY THE SEOR. <br />18. SEE ARCHITECT'S PLANS FOR LOCATIONS OF SLAB SLOPES, DEPRESSIONS, <br />CURBS, DRAINS, NON-STRUCTURAL PARTITIONS AND OTHER EMBEDDED <br />ITEMS NOT SHOWN ON THE STRUCTURAL PLANS. <br />19. EXPOSED CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE <br />FORMED WITH 3/4" CHAMFER, U.N.O. <br />20. CONSTRUCTION JOINTS (CJ) AND SAWCUT (SC) JOINTS IN SLABS SHALL <br />OCCUR WHERE LOCATED ON PLANS AND DETAILS. CJ'S SHALL HAVE FORMED <br />POUR STOPS. CONSTRUCTION JOINTS IN WALLS AND FOOTINGS NEED NOT <br />OCCUR AT THE SAME LOCATION, U.N.O. <br />STRUCTURAL CONCRETE NOTES: <br />LOCATION <br />MIN 28-DAY <br />COMP <br />STRENGTH <br />FOUNDATIONS <br />STEM WALLS, PILASTER 4000 PSI NWC 1 1/2" 0.45 4" II / V <br />CONC <br />TYPEa <br />MAX <br />AGGR. <br />SIZE <br />MAX <br />W/C <br />RATIO <br />MAX <br />SLUMPb <br />CEMENT <br />TYPE <br />4000 PSI NWC 1" 0.45 4" II / V <br />4000 PSI NWC 1" 0.50 6" II / V <br />SLAB ON GRADE <br />ALL OTHER STRUCTURAL <br />CONCRETE NO NOTED.. <br />E N G I N E E R S I N CV C A <br />2151 Michelson Dr. #240 <br />Irvine, CA 92612 <br />Tel. 949.679.0870 <br />Fax. 949.679.9370 <br />Project No.: J804 <br />C I V I LQuality <br />Service <br />Commitment <br />S T R U C T U R A L DBEMBE SBE <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />DATE ISSUED: <br />PROJECT NO: <br />12" = 1'-0" <br />Issue Date <br />S-0.2 <br />GENERAL NOTES <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />CI <br />T <br />Y <br />, <br /> <br />S <br />T <br />A <br />T <br />E <br /> <br />Z <br />I <br />P <br /> <br />C <br />O <br />D <br />E <br />DESCRIPTION DATE <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />505 E Central Ave <br />#B11/6/2024