My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Delhi Community Center Library Renovation 9/29/2023 <br />Santa Ana, California <br /> <br /> <br /> 01 30 00 - 7 Administrative Requirements <br />B. Contractor acknowledges and accepts responsibility for specialty design as part of <br />means and methods of construction, as well as coordination of parties involved to <br />achieve architectural design intent indicated in Contract Documents. <br />1. Design-build work includes sizing, sequencing, and detailing for construction by <br />professional licensed or registered engineer or design professional with special <br />expertise applicable to portion of Work involved. <br />2. Design-build work shall be constructed in compliance with building codes and <br />regulations in effect and shall be fit and proper for intended use. <br />3. Design-build work shall include drawings, specifications, and calculations <br />prepared, stamped, and signed by qualified professional licensed or registered <br />engineer licensed in the Project location as appropriate to design-build work. <br />a. Plans, specifications, and calculations shall be acceptable to Owner, <br />Owner’s Representative, and applicable authorities. <br />C. Where required by Owner Contractor shall submit copies of current insurance policies <br />covering errors and omissions of persons designing design-build work with <br />deductibles and limits per occurrence as mutually agreed by Owner and Contractor. <br />1. Provide endorsement to insurance providing for 30-day notice to Owner prior to <br />cancellation or material reduction in coverage. <br />2. Insurance shall be maintained for not less than applicable statute of limitations <br />for claims of latent defects, if such insurance is not written on an occurrence <br />basis during time design-build work is designed and constructed. <br />D. Review proposed layouts with Design Team and with various trades prior to <br />commencing work related to design-build work. <br />1.11 DEFERRED APPROVAL REQUIREMENTS <br />A. Installation of deferred approval items shall not be started until detailed plans, <br />specifications, and engineering calculations have been accepted and signed by <br />Architect or Engineer of Record responsible for Project design. <br />B. Deferred Approval Items shall be signed by California registered architect or <br />professional engineer delegated responsibility covering specific work shown requiring <br />approval by Division of the State Architect. <br />1. Deferred approval items for this Project include but may not be limited to <br />following: <br />a. Translucent Walls and Roofs – Section 08 45 00. <br />b. Telescopic Bleachers – Section 12 66 01. <br />c. Grandstands – Section 13 34 16. <br />d. Hydraulic Elevators – Section 14 24 00. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.