Laserfiche WebLink
Delhi Community Center Library Renovation 9/29/2023 <br />Santa Ana, California <br /> <br /> 01 45 80 - 7 Testing Laboratory Services <br /> <br /> (4) Bond and Shear Tests - 1403A.5.6 <br /> <br /> (b) Inspection of Veneer <br /> <br /> (1) Veneer Inspection - 1405A <br /> <br /> 7. Roof Covering (Chapter 15) <br /> <br /> (a) Materials <br /> <br /> (1) Roof Tile tests - 1507.7.1 <br /> <br /> B. Perform tests and inspections for the following in conformance with the <br />California Building Code (CBC), Title 24, Part 2 of the California Code of <br />Regulations (CCR). <br /> <br /> 1. Foundations - Chapters 18 and 33: <br /> <br /> a. Earth Fill Compaction - ASTM D1556, ASTM D 1557 <br /> <br /> 2. Concrete and Lightweight Concrete - Chapter 19: <br /> <br /> a. Portland Cement Tests - 1903.1 <br /> <br /> b. Concrete Aggregates - 1903.3 <br /> <br /> c. Reinforcing Bars - 1903.5 <br /> <br /> 3. Concrete Quality - Chapter 19: <br /> <br /> a. Proportions of Concrete - 1905.2 <br /> <br /> b. Strength Tests of Concrete - 1905.3 <br /> <br />NOTE: Strength tests are not required for equipment pads, pipe and conduit cover and minor <br />non-structural concrete. <br /> <br /> 4. Steel - Chapter 22: <br /> <br /> a. Structural Steel - 2203.2 <br /> <br /> b. Field Welding - 2205.10 <br /> <br /> c. High Strength Bolts - 2205.11 <br /> <br /> d. Shop Welding - 2205.10 <br /> <br /> C. Perform additional test required by individual Specification Sections. <br /> <br /> 1.10 SCHEDULE OF INSPECTIONS AND TESTS BY CONTRACTOR <br />505 E Central Ave <br />#B11/6/2024