My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TEEN AREA <br />4 <br />GENERAL <br />STACKS <br />3 <br />OFFICE <br />1 <br />(E) PNL 1P <br />(E) PNL 2P <br />(E) PNL 3P <br />(E) PNL 4P <br />(E) PNL 1L <br />(E) PNL 2L <br />RESTROOM <br />2 <br />CHILDRENS AREA <br />5 <br />EXISTING <br />HALLWAY <br />6 <br />E102 <br />1 <br />ELEC. ROOM <br />PNL 2L-31 <br />1 3 <br />7 <br />4 <br />5 <br />PANEL 2PA <br />2 <br />6 <br />8 <br />HARD <br />CEILING <br />HARD <br />CEILING <br />HARD <br />CEILING <br />T-BAR <br />CEILING <br />T-BAR <br />CEILING <br />T-BAR <br />CEILING <br />HARD <br />CEILING <br />(ACCESS PANELS IN <br />THIS CEILING <br />ARE NOT ALLOWED) <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />Consulting Engineer <br />www.alphamep.net <br />1/8" = 1'-0" <br />Issue Date <br />E101 <br />FLOOR PLAN - <br />ELECTRICAL <br />23-020-01 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />Scale: <br />1/8" = 1'-0"1FLOOR PLAN - ELECTRICAL <br />G E N E R A L N O T E S: <br />A. SEE SHEET E000 FOR SYMBOL LIST, ELECTRICAL, POWER AND LIGHTING NOTES, AND <br />ADDITIONAL INFORMATION. <br />B. THIS PLAN OVERALL PLAN SHOWS LOCATIONS OF EXISTING PANELS, AND NEW <br />RECEPTACLES. REFER TO SHEET 102 FOR ADDITIONAL INFORMATION. <br />C. NEW SERVICE PROVIDER CABLES AND EQUIPMENT ARE BEING INSTALLED BY THE <br />SERVICE PROVIDER AND COORDINATED BY THE OWNER (NOT SHOWN). <br />D. ROUTING OF NEW LOW VOLTAGE CONDUIT IS SCHEMATIC IN NATURE. THE <br />CONTRACTOR SHALL COORDINATE THE ACTUAL ROUTING IN THE FIELD, ENSURING NO <br />MORE THAN (2) 90 DEGREE TURNS WITHOUT A JUNCTION BOX. PROVIDE ACCESS <br />PANELS IN CEILING (MAINTAIN CEILING RATING) AS REQUIRED. <br />E. CONDUIT FOR NEW PANEL 2PA SHALL FOLLOW THE SAME PATH AS THE NEW LOW <br />VOLTAGE CONDUIT. THE CONTRACTOR SHALL FIELD COORDINATE ACTUAL ROUTING. <br />THE CONDUIT SHALL HAVE A PERMANENT LABEL EVERY 25' INDICATING IT IS SERVING <br />PANEL 2PA. <br />C O D E D N O T E S: <br />1. PROVIDE DEDICATED CIRCUIT TO A NEW QUAD OUTLET ON EXITING BACKBOARD. <br />CONTRACTOR SHALL PROVIDE A NEW 20A-1P BREAKER IN EXISTING PANEL,EXTEND (2)# <br />12 COPPER AND (1) #12 GROUND IN 3/4”CONDUIT. COORDINATE EXACT PLACEMENT OF <br />OUTLET WITH THE OWNER PRIOR TO ROUGH-IN. <br />2. PROVIDE TELECOM GROUND BAR ADJACENT TO NEW SERVICE PROVIDER EQUIPMENT <br />ON EXISTING BACKBOARD. SEE DETAILS SHEET FOR MORE INFORMATION. <br />3. (2) CAT6 CABLES SHALL EXTEND FROM THE NEW SERVICE PROVIDER EQUIPMENT TO <br />NEW RACK. PENETRATION THRU ELECTRICAL ROOM WALL SHALL BE FIRE CAULKED TO <br />MAINTAIN THE FIRE RATING OF THE ELECTRICAL ROOM. <br />4. EXTEND (2) CAT6 CABLES IN CEILING SPACE, SUPPORT INDEPENDENTLY FROM <br />STRUCTURE WITH D-RINGS AND/OR J-HOOKS. CABLES SHALL BE MOUNTED WITH <br />HOOK/LOOP STRAPS SEPARATE FROM OTHER CABLES AT A MINIMUM OF EVERY 5’AND <br />LABELED (PER OWNER’S INSTRUCTION) EVERY 20’. THE CONTRACTOR MAY REUSE <br />EXISTING CABLES SUPPORTS PROVIDED THE ARE DEDICATED TO DATA CABLING, DON'T <br />EXCEED 40% FILL, PROVIDE PROPER SUPPORTS, AND ARE INDEPENDENTLY <br />SUPPORTED FROM STRUCTURE (NOT FROM OTHER SYSTEMS). THE ROUTING IS <br />SCHEMATIC, CONTRACTOR SHALL COORDINATE EXACT ROUTING IN THE FIELD. THE <br />CABLE SHALL BE TERMINATED AND TESTED, LANDING IN A NEW DATA OUTLET ON BOTH <br />ENDS.ELECTRICAL CONTRACTOR SHALL PATCH AND REPAIR ANY DAMAGE CAUSED TO <br />EXISTING WALL AND CEILING DURING THE INSTALLATION AT HIS OWN COST. REPAIRING <br />SHALL BE DONE TO MATCH THE EXISTING CONDITION. <br />5. DROP NEW CABLES INTO A NEW FACEPLATE IN THE BACK OF THE NEW DATA RACK. <br />6. DROP A 4" (MINIMUM) CONDUIT IN WALL TO A J-BOX RECESSED IN WALL BEHIND THE <br />DATA RACK FOR NEW DATA CABLES. <br />7. EXISTING UNDERGROUND 4" CONDUITS SHOWN FOR REFERENCE ONLY. <br />8. PENETRATION THRU WALL SHALL BE FIRE CAULKED TO MAINTAIN THE FIRE RATING. <br />N04'8'16' <br />DESCRIPTION DATE <br />Consulting Engineer <br />www.alphamep.net <br />7/08/24 <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.