Laserfiche WebLink
TEEN AREA <br />4 <br />GENERAL <br />STACKS <br />3 <br />OFFICE <br />1 <br />2PA - 5 <br />2PA - 10 <br />AC-1 <br />1 <br />WIFI <br />2PA - 7 <br />2PA - 1 <br />2PA - 6 <br />4 <br />RESTROOM <br />2 <br />CHILDRENS AREA <br />5 <br />EXISTING <br />HALLWAY <br />6 <br />2PA - 4 <br />2PA - 12 <br />2PA - 13 <br />2PA - 3 <br />3 <br />3 <br />TV TV <br />EF-1 <br />5 <br />OVERHEAD CONTROLLER <br />6 <br />2PA - 18,20 <br />OVERHEAD <br />DOOR <br />COFFEE MAKER <br />MICROWAVE <br />(E) <br />4 <br />(E) <br />4 <br />(E) <br />2 2 <br />COPIER <br />COPIER <br />DATA RACK <br />2PA - 17 <br />10 <br />WIFI ~12' AFG <br />WIFI ~12' AFG <br />8 <br />8 <br />WP <br />WP <br />3 <br />SAWCUT & <br />PATCH <br />2PA - 21 <br />SAWCUT & <br />PATCH <br />9 <br />WIFI <br />1D <br />3D <br />4D <br />1D <br />3D 3D <br />2D <br />2D <br />2D <br />3D <br />PANEL 2PA <br />1D <br />1D <br />+78" <br />2D <br />3D <br />3D <br />DOOR RELEASE BUTTON <br />11 <br />SAWCUT & <br />PATCH <br />1212 <br />13 <br />2PA - 14 <br />TP <br />TP <br />TP <br />TP <br />TP <br />TP <br />TP <br />TP <br />TPTP <br />TP TP <br />TP <br />TP TP TP <br />TP <br />TP <br />3D <br />3D <br />AC <br />AC <br />AC <br />2PA - 2 <br />15 <br />14 <br />2PA - 8 <br />15 <br />14 <br />2PA - 25 <br />N02'4'8' <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />Consulting Engineer <br />www.alphamep.net <br />1/4" = 1'-0" <br />Issue Date <br />E102 <br />FLOOR PLAN - <br />POWER <br />23-020-01 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />G E N E R A L N O T E S: <br />A. SEE SHEET E000 FOR SYMBOL LIST, ELECTRICAL, POWER AND LIGHTING NOTES, AND <br />ADDITIONAL INFORMATION. <br />B. ALL THE NEW CIRCUITS SHALL BE CONNECTED TO PANEL 2PA UNLESS NOTED <br />OTHERWISE. <br />C. NEW RECEPTACLES AND DATA ROUGH-INS SHALL RECESSED UNLESS NOTED <br />OTHERWISE. COORDINATE WITH GC TO CUT, PATCH AND PAINT. DEVICES ON EXPOSED <br />BLOCK WALLS MAY USE LOW PROFILE, DUAL CHANNEL SURFACE RACEWAY PAINTED TO <br />MATCH THE WALL SURFACE. <br />D. MC CABLE AND FLEXIBLE CONDUIT MAY NOT BE USED WHERE IT WILL BE EXPOSED, AND <br />SHALL ONLY BE USED FOR THE FINAL 3' CONNECTION TO A NEW DEVICE. <br />E. ALL DATA OUTLETS SHALL BE TESTED AND LABELED, SEE DETAILS FOR MINIMUM <br />LABELING REQUIREMENTS AND CONFIRM EXACT REQUIREMENTS WITH OWNER. <br />F. DATA CABLING SHALL BE IN CONDUIT WHERE EXPOSED. CONCEALED CABLING MAYBE <br />OPEN CABLE BUT PROPERLY SUPPORTED WITH D-RINGS AND/OR J-HOOKS EVERY 5’(AT <br />A MIN.). <br />G. DATA CABLES SHALL BE CAT6, PLENUM RATED, 23 AWG, COMMSCOPE SYSTIMAX, UTP, <br />WITH BISECTOR. <br />H. CONDUIT FITTINGS FOR DATA CABLING SHALL BE COMPRESSION TYPE (NOT SCREW <br />TYPE). <br />I. SAW CUTS SHALL BE PERPENDICULAR AND PARALLEL TO WALLS. <br />C O D E D N O T E S: <br />Scale: <br />1/4" = 1'-0"1FLOOR PLAN - POWER <br />1. EXTEND CIRCUIT SERVING THE OUTDOOR UNIT TO INDOOR UNIT. REFER TO <br />MANUFACTURE DOCUMENT FOR ADDITIONAL DETAILS. ELECTRICAL WIRING TO FOLLOW <br />THE SAME PATH AS REFRIGERANT PIPING. <br />2. INSTALL RECEPTACLE ON CASE WORK. ROUTE (2) 1" CONDUIT(ONE FOR POWER AND <br />ONE DATA) FROM CASEWORK TO THE NEAREST WALL THRU FLOOR. CONTRACTOR <br />SHALL SAW CUT AND PATCH FLOOR TO ROUTE CONDUITS BELOW SLAB (COORDINATE <br />WITH GC). COORDINATE EXACT OUTLET LOCATIONS WITH OWNER AND GC PRIOR TO <br />ROUGH-IN. <br />3. EC SHALL ROUTE FLEX CONDUIT IN ADJACENT STOREFRONT MULLIONS FOR NEW <br />OUTLETS SHOWN, COORDINATE SPECIFICS WITH THE GC. <br />4. EXISTING RECEPTACLE TO REMAIN. ELECTRICAL CONTRACTOR TO REPLACE THE <br />DEVICE AND FACE PLATE AND REWIRE THE DEVICE AS SHOWN USING EXISTING <br />CONDUITS. <br />5. EXHAUST FAN SHALL BE CONTROLLED THRU SAME LIGHTING CONTROL CIRCUIT / <br />OCCUPANCY SENSOR SERVING THE ROOM. <br />6. PROVIDE ONE (1) 1" CONDUIT FROM OVERHEAD DOOR CONTROLLER TO JUNCTION BOX <br />SERVING OVERHEAD DOOR. EXACT LOCATION OF CONTROLLER TO BE COORDINATED <br />WITH OWNER/ARCHITECT PRIOR TO INSTALLATION. REFER TO EQUIPMENT <br />MANUFACTURER CUTSHEET FOR ADDITIONAL DETAIL. E.C. SHALL INCLUDE ALL <br />RACEWAY NEEDED FOR POWER AND CONTROL INCLUDING DOOR SENSORS. 1/4" <br />STAINLESS STEEL FLEX SHALL BE USED FOR FINAL CONNECTIONS TO DOOR SENSORS. <br />7. PROVIDE QUAD OUTLET IN THE BACK OF TELECOM RACK. COORDINATE EXACT <br />LOCATION PRIOR TO ROUGH IN. <br />8. PROVIDE ROUGH IN FOR WIFI ACCESS POINT. INCLUDE 2-GANG, NEMA 3R BACK BOX AND <br />1" CONDUIT TO THAT DATA RACK. GET MOUNTING DETAILS FROM OWNER PRIOR TO <br />ROUGH-IN. <br />9. FLOOR OUTLET, PROVIDE IN FLUSH MOUNTED FLOOR BOX WITH IN-USE COVER. COVER <br />PLATE FINISH BY ARCHITECT. SAW CUT AND PATCH FLOOR (COORDINATE WITH GC). <br />10. PROVIDE WALL MOUNTED DATA RACK, COORDINATE EXACT MOUNTING HEIGHT WITH <br />OWNER AND GC SO THE PROPER BLOCKING CAN BE PROVIDED. THE RACK SHALL BE <br />TRIPP-LITE SRW12US33G (OR EQUAL), WITH A MIN. OF 12 RU’S, HINGED, LOCKABLE, AND <br />32”MOUNTING DEPTH. <br />11. INSTALL JUNCTION ON CASE WORK. ALL THE SAW CUTTING TO BE COORDINATED WITH <br />FURNITURE PLAN. ROUTE (1) 3/4" CONDUIT FROM CASEWORK TO THE NEAREST WALL <br />THRU FLOOR. CONTRACTOR SHALL SAW CUT AND PATCH FLOOR TO ROUTE CONDUITS <br />BELOW SLAB (COORDINATE WITH GC). INSTALL SWITCH TO DISENGAGE THE RESTROOM <br />DOOR IN THE JUNCTION BOX. EXACT LOCATION OF SWITCH TO BE FIELD VERIFIED WITH <br />ARCHITECT/OWNER PRIOR TO INSTALLATION. <br />12. RUN THE (1) ONE 3/4" CONDUIT IN THE CEILING ABOVE AND DROP DOWN NEAR THE <br />DOOR. EXACT ROUTING PATH TO BE DECIDED ON FIELD BY ELECTRICAL CONTRACTOR. <br />13. JUNCTION BOX FOR MAGNETIC DOOR HOLD. EXTEND CONDUIT FROM CEILING TO <br />JUNCTION BOX. PROVIDE 120V CONNECTION FROM THE CIRCUIT SERVING THE REST <br />ROOM, USING 2#12 AND 1#12 GROUND IN 3/4" CONDUIT. <br />14. CONTRACTOR SHALL SAW CUT AND PATCH FLOOR TO EXTEND POWER AND DATA TO <br />THE SECURITY GATE. COORDINATE EXACT REQUIREMENTS WITH SECURITY GATE <br />SUPPLIER AND INSTALL REQUIREMENTS PRIOR TO SAW CUTTING. <br />15. EXTEND POWER AND DATA RACEWAY AND CABLE IN THE WALL CAVITY AS SHOWN. <br />CONNECT POWER TO THE CIRCUIT INDICATED. DATA CABLE SHALL BE EXTENDED TO <br />THE DATA RACK AND TERMINATED IN THE PATCH PANEL. AT THE GATE END OF THE <br />CABLE, THE CONTRACTOR SHALL PROVIDE THE APPROPRIATE CONNECTOR TO PLUG <br />INTO THE SECURITY GATE. <br />DESCRIPTION DATE <br />Consulting Engineer <br />www.alphamep.net <br />7/08/24 <br />505 E Central Ave <br />#B11/6/2024