PATH OF TRAVEL <br />PATH OF TRAVEL (P.O.T) AS INDICATED MEETS THE FOLLOWING <br />REQUIREMENTS: <br />1. IS A BARRIER-FREE ACCESSIBLE ROUTE WITHOUT ANY ABRUPT LEVEL <br />CHANGES EXCEEDING 1/2" BEVELED AT A SLOPE NOT STEEPER THAN 1:2 <br />EXCEPT THAT LEVEL CHANGES ARE 1/4" MAX VERTICAL & IS AT LEAST 48" <br />WIDE. <br />2. SURFACE SHALL BE STABLE, FIRM AND SLIP RESISTANT. <br />3. CROSS-SLOPE SHALL NOT BE STEEPER THAN 1:48 AND RUNNING SLOPE <br />SHALL NOT BE STEEPER THAN 1:20 UNLESS OTHERWISE INDICATED (SEC <br />11B-403.3) <br />4. P.O.T. SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO <br />80" MINIMUM (SECTION 11B-307.4) AND PROTRUDING OBJECTS GREATER <br />THAN 4" <br />PROJECTION FROM WALL SURFACE BETWEEN 27" AND 80" ABOVE FINISH <br />FLOOR <br />OR GROUND (SECTION 11B-307.2) <br />5.PROVIDE FLUSH TRANSITIONS AT ANY ADJOINING JOINTS BETWEEN <br />DIFFERENT WALK SURFACES IN P.O.T. <br />LIMITS OF WORK FOR THIS PROJECT <br />DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE <br />STATEMENT: <br />THE P.O.T. IDENTIFIED IN THESE CONSTRUCTION DOCUMENTS IN <br />COMPLIANT WITH THE CURRENT APPLICABLE CALIFORNIA BUILDING <br />CODE ACCESSIBILITY PROVISIONS FOR PATH OF TRAVEL <br />REQUIREMENTS FOR ALTERATIONS, ADDITIONS AND STRUCTURAL <br />REPAIRS. AS PART OF THE DESIGN OF THIS PROJECT, THE POT WAS <br />EXAMINED AND ANY ELEMENTS, COMPONENTS OR PORTIONS OF THE <br />P.O.T. THAT WERE DETERMINED TO BE NONCOMPLIANT 1) HAVE BEEN <br />IDENTIFIED AND 2) THE CORRECTIVE WORK NECESSARY TO BRING THEM <br />INTO COMPLIANCE HAS BEEN INCLUDED WITHIN THE SCOPE OF THIS <br />PROJECT'S WORK THROUGH DETAILS, DRAWINGS AND SPECIFICATIONS <br />INCORPORATED INTO THESE CONSTRUCTION DOCUMENTS. ANY <br />NONCOMPLIANT ELEMENTS, COMPONENTS OR PORTIONS OF THE POT <br />THAT WILL NOT BE CORRECTED BY THIS PROJECT BASED UPON THE <br />VALUATION THRESHOLD OR A FINDING OF UNREASONABLE HARDSHIP <br />ARE SO INDICATED IN THESE CONSTRUCTION DOCUMENTS. <br />DURING CONSTRUCTION, IF P.O.T. ITEMS WITHIN THE SCOPE OF THE <br />PROJECT REPRESENTED AS CODE COMPLIANT ARE FOUND TO BE <br />NONCONFORMING BEYOND REASONABLE CONSTRUCTION TOLERANCES, <br />THEY SHALL BE BROUGHT INTO COMPLIANCE WITH THE CBC AS PART OF <br />THIS PROJECT BY MEANS OF A CONSTRUCTION CHANGE DOCUMENT. <br />PROPERTY LINE <br />DELHI COMMUNITY CENTER <br />SCOPE OF T.I. <br />SURFACE LEVEL <br />PARKING <br />NOT IN SCOPE <br />SURFACE LEVEL <br />PARKING <br />NOT IN SCOPE <br />E CENTRAL AVENUEE CENTRAL AVENUE <br />PROPERTY LINE <br />PROPERTY LINE <br />PROPERTY LINE <br />OPEN LANDSCAPE <br />PL <br />PL <br />PL PL <br />PL <br />SURFACE LEVEL <br />PARKING <br />NOT IN SCOPE <br />LIMITS OF WORK <br />S1 <br />S2 <br />S3 <br />S4 S4 <br />S4 <br />4' <br /> <br />- <br /> <br />6 <br />" <br />9' <br /> <br />- <br /> <br />6 <br />" <br />S1 <br />S2 ACCESSIBLE PARKING PER CBC , AREA TO BE RE-STRIPED <br />S3 EXISTING FULLY ACCESSIBLE PRIMARY ENTRANCE TO REMAIN <br />SEE L4.101 FOR LANDSCAPE CONSTRUCTION PLAN <br />S4 ACCESSIBLE PARKING TO BE RE-STRIPED. RELOCATE (E) SIGNAGE PER <br />NEW LAYOUT. REFER TO A11.1 FOR ADDITIONAL INFORMATION <br />S5 REMOVE EXISTING LANDSCAPING/IRRIGATION AS NEEDED FOR <br />INSTALLATION OF NEW CONCRETE SIDEWALK. <br />S6 SALVAGE EXISTING BENCHES <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />Issue Date <br />A01.1 <br />OVERALL SITE <br />PLAN <br />#2022-40198 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />SITE PLAN LEGEND3/64" = 1'-0"1SITE DEMOLITION PLAN <br />DESCRIPTION DATE <br />N <br />SITE PLAN KEYNOTES <br />505 E Central Ave <br />#B11/6/2024