Laserfiche WebLink
PROJECT SITE <br />(1,848 SF) <br />TRASH <br />(E) MacArthur blvd. <br />Ma <br />c <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />. <br />Hutton Centre Dr. <br />PATH <br /> <br />O <br />F <br /> <br />T <br />R <br />A <br />V <br />E <br />L <br />A-001 <br />NOTE : <br />ISSUES & REVISIONS <br />CONSULTANT : <br />PROJECT : <br />REVISION DESCRIPTIONDATENO. <br />DESIGNED BY <br />DRAWN BY <br />CHECKED BY <br />APPROVED <br />TITLE <br />SCALE <br />PROJECT NO. <br />DRAWING NO. <br />SHEET NO. <br />DATE <br />EroomDesign Icn.EroomDesign Inc <br />1411 ALBANY ST <br />LOS ANGELES, CA 90015 <br />TELEPHONE 323-544-7688 <br />architecture interior & space design <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br /> <br />9 <br />4 <br />9 <br /> <br />G <br />R <br />I <br />L <br />L <br /> <br />A <br />N <br />D <br /> <br />P <br />O <br />T <br /> <br />L <br />O <br />U <br />N <br />G <br />E <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br /> <br />: <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />2 <br />H <br />U <br />T <br />T <br />O <br />N <br /> <br />C <br />E <br />N <br />T <br />R <br />E <br /> <br />D <br />R <br /> <br /># <br />2 <br />0 <br />4 <br />SITE PLAN1 <br />SCALE : NTS1A <br />SANTA ANA CA 92707 <br />2 HUTTON CENTRE DR. #204 <br />FIRE DEPT. NOTESGENERAL NOTES <br />949 GRILL AND POT LOUNGE <br /> 1. FIRE DEPARTMENT INSPECTIONS AREA REQUIRED. SCHEDULE ALL INSPECTIONS 2 DAYS IN ADVANCE. <br /> 2. A DETAILED LETTER CLEARLY IDENTIFYING ALL INTENDED USE(S) AND OPERATION(S) OF THE STRUCTURE(S) <br /> SHALL BE PROVIDED TO THE FIRE DEPARTMENT ALONG WITH THE SUBMITTALS FOR REVIEW. <br /> 3. WHEN THE PROJECT INVOLVES THE CONSTRUCTION OF A NEW STRUCTURE OR AN ADDITION TO AN EXISTING <br /> STRUCTURE, PLANS AND DOCUMENTS FOR FIRE DEPARTMENT ACCESS, FIRE HYDRANT LOCATIONS, WATER <br /> AVAILABILITY, AND FIRE LANE MARKINGS SHALL BE SUBMITTED TO THE FIRE DEPARTMENT PRIOR TO THE <br /> APPROVAL OF ARCHITECTURAL PLANS. CITY OF SANTA ANA FIRE DEPARTMENT APPROVED SITE PLAN <br /> SHALL BE SUBMITTED ALONG WITH THE ARCHITECTURAL PLAN SUBMITTAL(S). <br /> 4. THIS PLAN REVIEW OR APPROVAL ENCOMPASSES THE BUILDING T.I PLANS ONLY. FIRE SPRINKLER SYSTEM(S), <br /> ALARM SYSTEM(S),UNDERGROUND FIRE LINES OR ANY OTHER FIRE PROTECTION SYSTEM OR REQUIRED FIRE <br /> DEPARTMENT PERMIT(S), REQUIRES A SEPARATE PLAN SUBMITTAL AND ARE NOT ENCOMPASSED IN THIS PLAN <br /> REVIEW OR APPROVAL. <br /> 5. PROVIDE 6 INCH ADDRESS NUMERALS ON EACH SUITE(S) OR UNIT(S) FRONT AND REAR DOORS. NUMERALS <br /> SHALL BE A COLOR CONTRASTING TO THE BACKGROUND. <br /> 6. PLANS OF NEW OR MODIFICATIONS TO EXISTING FIRE PROTECTION, DETECTION, ALARM OR MONITORING <br /> SYSTEM(S) SHALL BE APPROVED BY THE CITY OF SANTA ANA FIRE DEPARTMENT PRIOR TO INSTALLATION <br /> OR MODIFICATION A SEPARATE PLAN SUBMITTAL IS REQUIRED FOR EACH ELEMENT OF PROTECTION PRIOR TO <br /> THE COMMENCEMENT OF ANY WORK, AS THIS PROJECT WAS CONDITIONED, ONLY MALL APPROVED <br /> CONTRACTORS SHALL BE PERMITTED TO ADD TO OR MODIFY THESE SYSTEMS. <br /> 7. IF ADDITIONS OF WALLS AND/ OR OTHER TENANT IMPROVEMENTS OBSTRUCT OR EFFECT COVERAGE OR <br /> PERFORMANCE OF THE FIRE SPRINKLER SYSTEM IS NECESSARY, FIRE SPRINKLER TENANT IMPROVEMENT <br /> PLANS SHALL BE SUBMITTED TO THE CITY OF SANTA ANA FIRE DEPARTMENT FOR APPROVAL PRIOR TO <br /> INSTALLATION OR ALTERATION(S). <br /> 8. ASSEMBLY OCCUPANCIES SHALL POST A, "MAXIMUM OCCUPANT LOAD OF PERSONS", SIGN NEAR THE MAIN EXIT <br /> FROM EACH ROOM. SPRINKLER SYSTEM IS NECESSARY, FIRE SPRINKLER TENANT IMPROVEMENT. <br /> 9. SIGNAGE ABOVE MAIN EXIT DOORS WITH ONE-INCH LETTER IS TO READ, "THIS DOOR TO REMAIN UNLOCKED <br /> WHEN OCCUPIED." <br />10. ALL EXIT DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR <br /> EFFORT. ALL "A" OCCUPANCY CLASSIFICATIONS SHALL BE PROVIDED WITH PANIC HARDWARE FOR THE EXIT <br /> DOORS. <br />11. PROVIDE FIRE-RATED HARDWARE IN ALL RATED ASSEMBLES. <br />12. LOCATION(S) AND CLASSIFICATION(S) OF FIRE EXTINGUISHERS SHALL BE IN ACCORDANCE WITH THE <br /> CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 19 AND THE CALIFORNIA FIRE CODE STANDARD 10-1 AND <br /> PLACEMENT IS SUBJECT TO THE FIRE INSPECTION PRIOR TO FIRE CLEARANCE FOR THE CERTIFICATE OF <br /> OCCUPANCY TO BE ISSUED BY THE BUILDING DEPARTMENT. <br />13. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE OR COMPRESSED <br /> GASES, OR ANY OTHER HAZARDOUS MATERIALS SHALL COMPLY WITH CALIFORNIA FIRE CODE REGULATIONS. <br /> THE STORAGE AND USE OF HAZARDOUS MATERIALS SHALL BE APPROVED BY THE CITY OF SANTA ANA FIRE <br /> DEPARTMENT PRIOR TO ANY MATERIAL BEING STORED, OR USED ON SITE, A SEPARATE PLAN SUBMITTAL IS <br /> REQUIRED PRIOR TO THE STORAGE AND USE OF HAZARDOUS MATERIALS. <br />14. ALL BUILDING(S) SHALL BE APPROVED FOR HIGH-PILED STORAGE (MATERIAL IN CLOSELY PACKED PILES OR <br /> ON PALLETS, OR IN RACKS WHERE THE TOP OF STORAGE IS EXCEEDS 12" HEIGHT, 6' FOR GROUP A PLASTICS <br /> AND CERTAIN OTHER HAZARDOUS COMMODITIES) OR AEROSOLS PRODUCTS. HIGH-PILED AND AEROSOL STOCK <br /> SHALL BE APPROVED BY THE CITY OF SANTA ANA FIRE DEPT. PRIOR TO MATERIAL BEING STORED ON SITE. <br /> A SEPARATE PLAN SUBMITTAL IS REQUIRED FOR ARTICLES 81 AND 88. <br />15. AN AUTOMATIC EXTINGUISHING SYSTEM(S) SHALL BE PROVIDED TO PROJECT COMMERCIAL-TYPE FOOD HEATING <br /> AND PROCESSING EQUIPMENT THAT PRODUCES GREASE LADEN VAPORS. A SEPARATE PLAN SUBMITTAL IS <br /> REQUIRED FOR INSTALLATION OF THE SYSTEM AND SHALL BE IN ACCORDANCE WITH CFC, ART.10, NPPA 17A, <br /> AND 96. <br />16. ALL GAS AND ELECTRICAL POWER UNDER COOKING HOOD(S) SHALL SHUT DOWN UPON ACTUATION OF THE <br /> HOOD FIRE SUPPRESSION SYSTEM. <br />17. ALL HVAC UNIT OR SYSTEM (REGARDLESS OF CFM, AS REQUIRED BY THE MALL SMOKE CONTROL RATIONAL <br /> ANALYSIS REPORT SHALL HAVE AUTOMATIC SMOKE DUCT-DETECTORS INSTALLED AND CONNECTED TO THE <br /> BUILDING FIRE ALARM SYSTEM. <br />18. PROVIDE VELOCITY CALCULATIONS FOR EACH DUCT DETECTOR LOCATION INSTALLED. THE CALCULATION IS <br /> TO INCLUDE THE DUCT SIZE AT POINT OF INSTALLATION, CFM OF THE AIR-HANDLER, AND VELOCITY FOR ALL <br /> MODES OF OPERATION INCLUDING ECONOMIZER MODE. <br />19. PROVIDE REMOTE LED ANNUNCIATOR(S) AND REMOTE TEST STATION FOR EACH DUCT DETECTOR LOCATED <br /> ABOVE THE CEILING AND BELOW THE ROOF. <br />20. THE MAXIMUM WIDTH OF STOREFRONT OPENING SHALL NOT EXCEED 12'. IN ADDITION THE MAXIMUM OPENING, <br /> A TRASOM/SOFT IS REQUIRED AT THE STOREFRONT OPENING HAVING A MINIMUM 18" DEPTH FOR THE LENGTH <br /> OF THE TRANSOM/SOFT AS REQUIRED BY THE MALL SMOKE CONTROL RATIONAL ANALYSIS REPORT. <br />21. SPOT-TYPE FIRE ALARM SYSTEM SMOKE DETECTOR(S) SHALL BE INSTALLED AT EACH TENANT SPACE OPENING <br /> (ENTRANCE AND/OR DISPLAY) TO THE MALL AREA(S) AS REQUIRED BY THE MALL SMOKE CONTROL RATIONAL <br /> ANALYSIS REPORT. <br />22. BUILDING/ TENANT ACCESS REQUIRES KEYS TO EACH TENANT SPACE BE PLACED INTO THE BUILDING MASTER <br /> KNOX BOX LOCATED INSIDE OF THE FIRE CONTROL ROOM. CONTACT THE CITY OF SANTA ANA FIRE <br /> PREVENTION BUREAU FOR PLACEMENT OF KEYS INTO THE BOX. <br />23. PROVIDE SIGNAGE ON ELECTRICAL EQUIPMENT "NO STORAGE WITHIN 36" BY ORDER OF THE FIRE MARSHALL" <br />24. PROVIDE BLACK/YELLOW HATCH STRIPES ON FLOOR 36" IN FRONT OF ELECTRICAL EQUIPMENT AND STENCIL <br /> "NO STORAGE" MINIMUM OF 4" LETTERS ON THE FLOOR INSIDE THE HATCHED STRIPES. <br />25. PROVIDE FIRE EXTINGUISHERS; CONTACT CCFD FOR SIZE, TYPE AND LOCATION. <br />26. FIRE ALARM/SMOKE CONTROL SYSTEM SHALL BE INSTALLED PER THE 2022 CALIFORNIA BUILDING CODE <br /> CHAPTER 4, 402.14 AND 404.4 AND AS APPROVED BY THE CITY OF SANTA ANA FIRE DEPARTMENT. <br />27. PROVIDE MALL APPROVE NUMBERS ON UPPER LEFT SIDE OF WINDOW FOR THE SUITE. <br />28. REMOVE ALL HASPS AND OTHER LOCKING DEVICES FROM REAR DOORS. DOOR EXITING HARDWARE SHALL <br /> COMPLY WITH 2022 CALIFORNIA BUILDING CODE, CHAPTER 4 AND CHAPTER 10. <br />29. INCLUDE NOTES IN REGARDS TO TOP OF ACTUAL STORAGE, COMMODITY CLASSIFICATION AND CLEARANCE TO <br /> FIRE SPRINKLERS PER NFPA 13. <br />30. INCLUDE NOTES THAT THE FIRE SPRINKLER SYSTEM SHALL BE MODIFIED TO ADJUST FOR INTERIOR <br /> IMPROVEMENTS. <br />31. EXTERIOR REAR DOOR SHALL BE MARKED WITH BUSINESS NAME AND SUITE NUMBER. <br />32. FINAL INSPECTION REQUIRED BY CITY OF SANTA ANA FIRE DEPARTMENT PRIOR TO OCCUPANCY. <br />33. BUSINESS OWNER SHALL BE NOTIFIED THAT REAR EXIT THAT OPENS TO THE SERVICE CORRIDOR/EMERGENCY <br /> SECONDARY EXIT SHALL BE KEPT FREE OF COMBUSTIBLE MATERIALS AND OTHER STORAGE AT ALL TIMES. <br />1. THESE DRAWINGS AND SPECIFICATIONS COPIES THEREOF ARE INSTRUMENTS OF SERVICE OF USE <br /> BY THE OWNER AND AUTHORIZED REPRESENTATIVES ON THE DESIGNATED PROPERTY ONLY. <br />2. ALL DIMENSIONS AND CONDITIONS SHALL BE CHECKED AND VERIFIED ON THE JOB SITE BY EACH <br /> SUBCONTRACTOR BEFORE THAT SUBCONTRACTOR BEGINS WORK. ANY ERRORS, OMISSIONS, OR <br /> DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNERS AND CONSTRUCTION <br /> MANAGER BEFORE CONSTRUCTION BEGINS. <br />3. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE. N OTE THAT DIMENSIONS ARE TO CENTER <br /> LINE, UNLESS OBVIOUSLY SHOWN, OR MARKED FACE OF CONCRETE (FOC) OR FACE OF STUD <br /> (FOS) OR FACE OF MASONARY (FOM), OR FACE OF FINISH (FOF). <br />4. TYPICAL DETAILS SHALL APPLY WHERE NO SPECIFIC DETAILS OR SECTION ARE GIVEN. <br />5. PROVIDE PEDESTRIAN AND PROPERTY PROTECTION BARRICADES AND/OR CANOPIES AS REQUIRED <br /> BY LOCAL AUTHORITIES, OR AS NECESSARY FOR PEDESTRIAN SAFETY. <br />6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTINUOUS CLEAN UP OF THE SITE, AND OF <br /> ALL DEBRIS, WETHER CREATED BY THIS WORK, OR BY THE FAILURE OF HIS SUB-CONTRACTORS <br /> TO CLEAN UP AFTER THEIR WORK. <br />7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SUPERVISE ALL CUTTING AND <br /> PATCHING OF FINISHED WORK ALREADY INSTALLED, IF MADE NECESSARY BY ERRORS, CHANGES <br /> OR OTHER REASONS. ALL REPLACEMENT WORK SHALL MATCH ADDITIONAL SURFACE. <br />8. CONTRACTOR SHALL PROVIDE GALVANIC INSULATION BETWEEN DISSIMILAR METALS. <br />9. PROVIDE AREA FOR COMBUSTIBLE RUBBISH STORAGE. <br />10. ALL SURVEY DATA IS BASED ON AN ORIGINAL SURVEY BY CITY OF SANTA ANA. <br />11. THERE SHALL BE NO EXPOSED PIPE CONDUITS, DUCTS, VENTS, ETC. IN DESIGNATED FINISH <br /> SPACES, UNLESS NOTED AS EXPOSED CONSTRUCTION. <br />12. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT ALL FIRE RATED SPACES, TO THE <br /> REQUIREMENTS OF THE APPLICABLE CODES AND STANDARDS. PROVIDE FIRE DAMPERS AND <br /> ACCESS PANELS FOR DUCTS AND A.C. FIXTURE WHEN PASSING THROUGH THESE SPACES. <br />13. PROVIDE APPROPRIATE FIRE ENCLOSURE BEHIND RECESSED LIGHT FIXTURE, WHERE REQUIRED. <br />14. PROVIDE FIRE EXTINGUISHER AS REQUIRED BY FIRE DEPT. FIELD INSPECTOR. <br />15. EXIT DOOR SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING MORE THAN 50 <br /> PERSONS. <br />16. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY <br /> SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF APPROVED TYPE. <br />17. EXIT LIGHTING AND SIGNS SHALL BE 6" X 3/4" MIN. ON A CONTRASTING BACKGROUND. <br />18. EXIT PATH LIGHTING SHALL BE PROVIDED GIVING A VALUE OF ONE FOOT CANDLE AT FLOOR <br /> LEVEL. <br />19. AISLE SHALL BE 44" MIN. CLEAR WIDTH TO A PUBLIC WAY. <br />20. NO SHARP OR ABRASIVE SURFACE UNDER LAVATORIES. GRAB BARS, FASTENERS AND MOUNTING <br /> DEVICES SHALL BE DESIGNED FOR 250 LBS. PER LINEAR FT. LOAD. <br />21. PROVIDE LEVER TYPE HARDWARE TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO <br /> GRASP THE OPENING HARDWARE. <br />22. EVERY REQUIRED EXIT DOORWAY SHALL NOT BE LESS THAN 3' WIDE BY NOT LESS THAN 6'-8" <br /> HIGH CAPABLE OF OPENING 90° AND MOUNTED SO THAT THE CLEAR WIDTH OF THE EXIT WAY <br /> IS A MINIMUM 32." <br />23. THE FLOOR ADJACENT TO A DOORWAY SHALL BE LEVEL AND CLEAR FOR A MINIMUM DEPTH OF <br /> 60" IN THE DIRECTION THE DOORWAY SWINGS AND 44" IF SWINGING AWAY. THE FLOOR SHALL <br /> EXTEND BEYOND THE STRIKE EDGE 24" FOR EXTERIOR DOORS AND 18" FOR INTERIOR DOORS. <br />24. STORAGE IS PROHIBITED IN EXIT PASSAGEWAY WHICH ARE ALSO USED FOR SERVICE TO THE <br /> TENANTS. SUCH EXIT PASSAGEWAYS SHALL BE POSTED WITH CONSPICUOUS SIGNS STATING SO. <br />25. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH THE CALIFORNIA CONSTRUCTION <br /> SAFETY ORDERS. <br />26. CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND ELECTRICAL EQUIPMENT AS TO <br /> WEIGHT AND LOCATIONS WITH STRUCTURAL SUPPORTS. IN THE EVENT THAT THE PURCHASED <br /> EQUIPMENT DEVIATES ARE DIFFERENT IN WEIGHT AND LOCATION FROM THOSE INDICATED ON <br /> THE PLANS, THE STRUCTURAL ENGINEER MUST BE NOTIFIED. <br />27. ALL TOILET ROOMS WITHOUT REQUIRED OPERABLE WINDOWS SHALL BE MECHANICALLY <br /> VENTILATED TO PROVIDE 5 MINUTE MINIMUM AIR CHANGE. FAN SHALL BE CONSIDERED AS <br /> PART OF WORK. <br />28. IN THE EVENT THERE ARE DISCREPANCIES, AMBIGUITIES OR OMISSIONS FROM THE <br /> SPECIFICATIONS OR DRAWINGS, OR SHOULD THERE BE DOUBT AS TO THEIR MEANING OR INTENT, <br /> THE DESIGNER SHALL BE NOTIFIED, IN ORDER TO PROVIDE A WRITTEN CLARIFICATION. <br />29. WHERE FACTORY PRIME ITEMS OCCUR, SUCH AS GRILLS, DIFFUSERS, METAL TRIM AND <br /> ACCESSORIES, ETC., PAINT TO MATCH THE ADJACENT SURFACE AS DIRECTED BY THE DESIGNER. <br /> REFER TO SPECIFICATIONS FOR ALL OTHER ITEMS NOT INCLUDED ON THE FINISH SCHEDULES. <br />30. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN APPROVAL BY THE LOCAL <br /> BUILDING INSPECTOR FOR ALL CONCEALED WORK BEFORE CLOSING UP. <br />31. PROVIDE 2 X SOLID BACKING FOR ALL CABINETS, TOWEL BARS, ETC. <br />32. PROVIDE OUTSIDE GAS SHUT-OFF VALVE, CONSPICUOUSLY MARKED. <br />33. PROVIDE WATERPROOF MEMBRANE OVER ALL EXTERIOR BUILDING WALLS BELOW GRADE. <br /> CARRY WATERPROOF MEMBRANE 4" ABOVE FINISH GRADE WHERE APPLICABLE. <br />34.TOW INCHES MINIMUM SAND IS TO BE PLACED OVER VAPOR BARRIER (6 MIL. MINIMUM), <br /> WHERE APPLICABLE. <br />35. PROVIDE FIRE DAMPER AT ALL DUCT OPENINGS. <br />36. INTERIOR WALL AND CEILING FINISH SHALL HAVE AT LEAST FLAME SPREAD RATING OF CLASS <br /> _____ AND SMOKE DENSITY OF _____. <br />37. FLOORS SHALL HAVE SURFACE THAT IS SLIP RESISTANT. <br />38. INTERIOR AND EXTERIOR THRESHOLDS SHOULD BE A MAX. 1/2" ABOVE THE ADJACENT FLOOR. <br />39. INSULATE HOT WATER AND DRAIN PIPE. <br />40. FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND NOT REQUIRE GRASPING, <br /> PINCHING OR TWISTING. <br />41. LOCATE ALL MANUALLY OPERATED SWITCHES AND CONTROLS BETWEEN 36" AND 38." <br />42. LOCATE CONVENIENCE OUTLETS A MINIMUM 12" FROM THE FLOOR. <br />43. DOOR OPENINGS INTO REQUIRED 1 HR. FIRE RESISTIVE CORRIDORS SHALL BE PROTECTED WITH <br /> A SMOKE OR DRAFT STOP FIRE ASSEMBLY HAVING A 20 MINUTE RATING, AND IS SELF CLOSING. <br />44. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME-PROOFED IN AN APPROVED <br /> MANNER. <br />PROJECT DATA <br />PROJECT DESCRIPTION:FIRE DAMAGED IN THE KITCHEN STOVE AREA <br />- REPLACE HOOD DUCT <br />- REPLACE EXHAUST FAN <br />- REPLACE KITCHEN HOOD <br />- REPAIR A MINOR DAMAGED ROOF <br />- REPAIR FIRE DAMAGED ELECTRICAL AND PLUMBING <br />PROJECT LOCATION : 2 HUTTON CENTRE DR. #204 <br /> SANTA ANA, CA 92707 <br />EXISTING USE : RESTAURANT <br />ZONING: SD <br />PROJECT AREA : 1,848 SF <br />OCCUPANT LOAD: 34 <br />DINING AREA:470 SF / 15 = 31.33 <br />KITCHEN AREA: 679 SF / 200 = 3.4 <br />STORAGE:61 SF / 300 = 1 <br />OFFICE 29 SF = 1 <br />2 RESTROOMS:62 SF = 2 <br />PARKING SPACES : NO CHANGE PARKING SPACES <br />NO. OF STORIES : 1-STORY <br />SPRINKLERS : FULLY SPRINKLERED - SPRINKLER SYSTEM SHALL BE <br /> SUPERVISED AUTOMATIC SYSTEM (NFPA 13). <br />EXIT : <br />REQUIRED: 1 EXIT <br />PROVIDED: 2 EXITS <br />SHEET INDEX APPLICABLE CODESAPPLICABLE CODES <br />2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE, Part 1, <br />2022 CALIFORNIA BUILDING CODE (C.B.C.), Title 24 C.C.R. <br />(2012 INTERNATIONAL BUILDING CODE WITH CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ELECTRICAL CODE (C.E.C.), Part 3, Title 24 C.C.R. <br />(2011 NATIONAL ELECTRICAL CODE WITH CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA MECHANICAL CODE (C.M.C.), Part 4, Title 24 C.C.R. <br />(2012 UNIFORM MECHANICAL CODE WITH CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA PLUMBING CODE (C.P.C.), Part 5, Title 24 C.C.R. <br />(2012 UNIFORM PLUMBING CODE WITH CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA FIRE CODE (C.F.C.), Part 9, Title 24 C.C.R. <br />2022 CALIFORNIA ENERGY CODE, Part 6, Title 24 <br />(2012 INTERNATIONAL FIRE CODE WITH CALIFORNIA AMENDMENTS) <br />VICINITY MAP <br />north <br />PROJECT DATA, <br />SITE PLAN <br />MAR. 2025 <br />A-001 TITLE, GENERAL NOTES <br />A-002 ADA NOTE <br />A-003 EXISTING FLOOR PLAN <br />A-004 EXISTING REFLECTED <br />CEILING PLAN <br />A-005 EQUIPMENT PLAN / SCHEDULE <br />A-006 DETAIL - 1 <br />M-1.0 HVAC GENERAL NOTES <br />AND LEGEND <br />M-1.1 HVAC EQUIPMENT SCHEDULES <br />& DETAILS <br />M-1.2 HOOD PACKAGE <br />M-1.3 HOOD PACKAGE <br />M-1.4 HOOD PACKAGE <br />M-1.5 HOOD PACKAGE <br />M-1.6 HOOD PACKAGE <br />M-1.7 HOOD PACKAGE <br />M-1.8 HOOD PACKAGE <br />M-1.9 HOOD PACKAGE <br />M-1.10 HOOD PACKAGE <br />M-2.0 HVAC CEILING PLAN <br />M-3.0 HVAC ROOF PLAN <br />T-24.0 TITLE 24 FORMS <br />S-1.0 GENERAL NOTES <br />& DETAILS <br />S-2.1 ROOF FRAMING PLAN <br />(HOOD) <br />S-2.2 ROOF FRAMING PLAN <br />(ROOF EQUIPMENT)