DISABLED ACCESSIBILITY NOTES
<br /> A. APPLICATION AND ADMINISTRATION - THIS IS N/A TO THIS PROJECT
<br />1. when alterations or additions are made to existing buildings or facilities, an accessible path of
<br /> travel to the specific area of alteration or addition shall be provided unless otherwise exempt.
<br /> §11b-202.4
<br />2. primary accessible path of travel shall include a primary entrance to the building or facility;
<br /> toilet and bathing facilities serving the area; drinking fountains serving the area; public
<br /> telephones serving the area, and signs. §11b-202.4
<br />3. the attached “summary of accessibility upgrades” form should be completed and submitted for
<br /> review, as not all elements are shown to comply with minimum accessibility code standards.
<br /> §11b-202.4 exception 8
<br />4. verify the project adjusted construction cost. if below the current valuation threshold
<br /> (as of jan. 2019: $166,157.00*) and not all elements are proposed to be improved to comply with
<br /> disabled access requirements, complete the attached
<br /> “summary of upgrades form” and detail path of travel improvements as required.
<br /> B. BUILDING BLOCKS
<br />1. confirm any elevation differences on the plans and provide detail(s) showing compliance with
<br /> section 11b-303 changes of level. §11b-303.1
<br />2. at the location(s) indicated on the plan, show and dimension the required turning space
<br /> (circle or t-shaped). §11b-304
<br />3. at the location(s) indicated on the plans, provide sections detailing minimum knee and toe
<br /> clearance. (at lavatories, sinks, dining and work surfaces…). §11b-306
<br />4. at the location(s) indicated on the plans, dimension the required clear floor or ground space.
<br /> §11b-305
<br />5. show on the site plan a guardrail or barrier that complies with the following. provide a
<br /> guardrail or other barrier with a leading edge located 27 inches maximum above the finish floor
<br /> or ground as the vertical clearance above the circulation path is reduced to less than 80 inches.
<br /> §11b-307.4
<br />6. provide dimensions to ensure the objects indicated on the plans do not protrude into the
<br /> accessible route clear width or more than 4 inches horizontally into the circulation path.
<br /> §11b-307.2
<br />7. add dimensions on the plans to ensure the objects indicated are within allowable reach ranges.
<br /> confirm front or side approach at unobstructed and/or obstructed conditions, as applicable.
<br /> §11b-308
<br />8. at required operable parts, indicate maximum force and specify operation type. §11b-309.4
<br /> C. ACCESSIBLE ROUTE OF TRAVEL
<br />1. show on the site plan accessible routes that comply with the following. at least one accessible
<br /> route shall be provided within the site from accessible parking spaces and accessible passenger
<br /> loading zones; public streets and sidewalks; and public transportation stops to the accessible
<br /> building or facility entrance they serve. where more than one route is provided, all routes must
<br /> be accessible. §11b-206.2.1
<br />2. show on the site plan at least one accessible route that complies with the following. at least
<br /> one accessible route shall connect accessible buildings, accessible facilities, accessible elements,
<br /> and accessible spaces that are on the same site. §11b-206.2.2
<br />3. show on the floor plans at least one accessible route that complies with the following. at
<br /> least one accessible route shall connect each story and mezzanine in multi-story buildings and
<br /> facilities. §11b-206.2.3 (see exceptions)
<br />4. show on the floor plans all accessibility requirements that comply with the following. although
<br /> the building is without an elevator, the upper/lower level(s) must still meet all accessibility
<br /> requirements.
<br />5. show on the floor/site plan accessible means of vertical access and dimensions that comply with
<br /> the following. in new construction of buildings where elevators are required by 11b-206.2.3
<br /> multi-story buildings and facilities, and which exceed 10,000 square feet on any floor, an
<br /> accessible means of vertical access via ramp, elevator or lift shall be provided within 200 feet
<br /> of travel of each stair and each escalator. §11b-206.2.3.2
<br />6. show on the floor/site plan accessible means of vertical access and dimensions that comply with
<br /> the following. in existing buildings that exceed 10,000 square feet on any floor and in which
<br /> elevators are required by 11b-206.2.3 multistory buildings and facilities, whenever a newly
<br /> constructed means of vertical access is provided via stairs or an escalator, an accessible means
<br /> of vertical access via ramp, elevator or lift shall be provided within 200 feet of travel of
<br /> each new stair or escalator. §11b-206.2.3.2
<br />7. show on the floor/site plans at least one accessible route that complies with the following. at
<br /> least one accessible route shall connect accessible building or facility entrances with all
<br /> accessible spaces and elements within the building or facility, including mezzanines, which are
<br /> otherwise connected by a circulation path. §11b-206.2.4 (see exceptions 1 through 7)
<br />8. show on the floor/site plan accessible routes and circulation paths that comply with the
<br /> following. accessible routes shall coincide with or be located in the same area as general
<br /> circulation paths. where circulation paths are interior, required accessible routes shall also be
<br /> interior. an accessible route shall not pass through kitchens, storage rooms, restrooms, closets
<br /> or other spaces used for similar purposes, except as permitted by chapter 10. §11b-206.3
<br />employee workstations
<br />9. detail accessible route to employee workstation and specify compliance with division 4. spaces
<br /> and elements within employee workstations shall only be required to comply with sections
<br /> 11b-207.1, 11b-215.3, 11b-302, 11b-303, and 11b-404.2.3. common use circulation paths within employee
<br /> workstations shall comply with section 11b-206.2.8. §11b-203.9
<br />10. indicate on the floor plans the use of each space. specifically call out common areas and
<br /> employee work stations.
<br />11. provide accessible details to comply with the following. the area indicated is a common area and
<br /> is not considered an employee workstation, therefore disabled access compliance details are
<br /> required. §11b-203.9 detectable warnings and detectable directional texture
<br />entrances
<br />13. show and specify the required primary building entry. §11b-206.4
<br />14. for the new building proposed, detail compliance at all entrances and exterior ground-floor
<br /> exits to buildings and facilities shall comply with 11b-404 doors, doorways, and gates.
<br /> §11b-206.4.1
<br />15. show and specify primary entry door and door(s) along path of travel, including door size(s),
<br /> hardware, landings, thresholds, kickplates, pressure, etc…§11b-206.5 technical requirements for
<br /> accessible routes
<br />technical requirements for accessible routes
<br />16. on the site plan, show and define the required accessible path of travel: 48 in minimum width
<br /> walkway, 5% maximum slope in the direction of travel, 2% maximum cross-slope. §11b-403.3 &
<br /> §11b-403.5
<br />17. delineate all walking surfaces and dimension the required widths (36”/44”/48”/60”). §11b-403.5
<br />doors, doorways, and gates
<br />18.specify all door and gate widths, heights, hardware, thresholds, kick plates, etc… §11b-404
<br />19.show and dimension all required landings/maneuvering clearances. §11b-402.2.4
<br />20.revolving doors, revolving gates, and turnstiles shall not be part of an accessible route.
<br /> §11b-404.2.1
<br />21.at least one of the active leaves of doorways with two leaves shall comply with 11b-404.2.3
<br /> clear width and 11b-404.2.4 maneuvering clearances. §11b-404.2.2
<br />22.door openings shall provide a clear width of 32 inches minimum. openings more than 24 inches
<br /> deep shall provide a clear opening of 36 inches minimum. specify all door widths on the plans
<br /> and/or at door schedule. §11b-404.2.3
<br />23.at doorways less than 36 inches wide without doors or gates, sliding doors, or folding doors
<br /> dimension required maneuvering clearances complying with table 11b-404.2.4.2. §11b-404.2.4.2
<br />24.dimension the minimum 18 inch interior and 24 inch exterior strike side clearance on the latch
<br /> side of all doors with adjacent obstruction. §11b-404.2.4.3
<br />25.provide threshold details for doors, indicating ½ inch maximum height. §11b-404.2.5.
<br />26.specify door hardware type(s) for all doors and gates and provide elevation indicating
<br /> hardware height between 34 inches minimum and 44 inches maximum above the finish floor or
<br />ground.§11b-404.2.7
<br />27.swinging door and gate surfaces within 10 inches of the finish floor or ground measured
<br /> vertically shall have a smooth surface on the push side extending the full width of the door
<br /> or gate. parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch
<br /> of the same plane as the other and be free of sharp or abrasive edges. cavities created by
<br /> added kick plates shall be capped. show and dimension required kickplate(s). §11b-404.2.10
<br />28.where sliding doors are in the fully open position, confirm operating hardware shall be exposed
<br /> and usable from both sides. §11b-404.2.7
<br /> D. GENERAL SITE AND BUILDING ELEMENTS
<br />parking spaces
<br />1. where parking spaces are provided, accessible parking spaces shall be provided in number and kind
<br /> required per section 11b-208 parking spaces. show and detail all required disabled access stalls,
<br /> including dimensions, markings, signage, clear height, etc… §11b-208
<br />2. provide ( ) accessible parking spaces as required by table 11b-208.2. §11b-208.2 (see exceptions)
<br />3. provide accessible spaces for each parking facility (parking lots and parking structures).
<br /> the number of parking spaces required to be accessible is to be calculated separately for each
<br /> parking facility; the required number is not based on the total number of parking spaces provided
<br /> in all of the parking facilities provided on site. §11b-208.2
<br />4. ten percent of patient and visitor parking spaces provided to serve hospital outpatient facilities,
<br /> and free-standing buildings providing outpatient clinical services of a hospital, shall comply with
<br /> section 11b-502 parking spaces. §11b-208.2.1
<br />5. twenty percent of patient and visitor parking spaces provided to serve rehabilitation facilities
<br /> specializing in treating conditions that affect mobility and outpatient physical therapy facilities
<br /> shall comply with section 11b-502 parking spaces. §11b-208.2.2
<br />6. one in every six or fraction of six parking spaces required by section 11b-208.2 minimum number,
<br /> but not less than one, shall be served by an access aisle 96 inches wide minimum placed on the
<br /> side opposite the driver…s side when the vehicle is going forward into the parking space and shall
<br /> be designated “van accessible”. all such spaces may be grouped on one level of a parking
<br /> structure. §11b-208.2.4 & §11b-502
<br />7. accessible parking spaces complying with section 11b-502 parking spaces serving a particular
<br /> building or facility shall be located on the shortest accessible route of travel from adjacent
<br /> parking to an accessible entrance (as near as practical to an accessible entrance). §11b-208.3.1
<br />8. in buildings with multiple accessible entrances with adjacent parking, accessible parking spaces
<br /> complying with section 11b-502 parking spaces shall be dispersed and located closest to the
<br /> accessible entrances. §11b-208.3.1
<br />9. in parking facilities that do not serve a particular building or facility, accessible parking
<br /> spaces complying with section 11b-502 parking spaces shall be located on the shortest accessible
<br /> route of travel to an accessible pedestrian entrance of the parking facility. §11b-208.3.1
<br />10. dimension minimum 18-foot long car and van accessible parking space(s) and access aisle(s).
<br /> §11b-502.2, figures 11b-502.2 & 11b-502.3
<br />11. dimension minimum 9-foot width at accessible car parking space. §11b-502.2, figures 11b-502.2
<br /> & 11b-502.3
<br />12. dimension minimum 12-foot wide accessible van parking space with minimum 5-foot wide access aisle.
<br /> van parking spaces shall be permitted to be minimum 9 feet wide where access aisle is 8-foot wide
<br /> minimum. §11b-502.2, figures 11b-502.2 & 11b-502.3
<br />13. car and van stall access aisle shall be 5 foot wide minimum and shall adjoin an accessible
<br /> route. two parking spaces shall be permitted to share a common access aisle. §11b-502.3, figures
<br /> 11b-502.2 & 11b-502.3
<br />14. access aisles shall be marked with a blue painted borderline around their perimeter.
<br /> the area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches
<br /> on center in a color contrasting with that of the aisle surface, preferably blue or white.
<br /> the words "no parking" shall be painted on the surface within each access aisle in white
<br /> letters a minimum of 12 inches in height and located to be visible from the adjacent vehicular
<br /> way. access aisle markings may extend beyond the minimum required length. §11b-502.3.3, figure
<br /> 11b-502.3.3
<br />15. access aisles shall not overlap the vehicular way. access aisles shall be permitted to be placed
<br /> on either side of the parking space except for van parking spaces which shall have access aisles
<br /> located on the passenger side of the parking spaces. §11b-502.3.4
<br />16. clearly show minimum vertical clearance of 8 feet 2 inches at accessible parking spaces and
<br /> along at least one vehicle access route to such spaces from site entrances and exits. §11b-502.5
<br />17. parking space identification signs shall include the international symbol of accessibility
<br /> complying with section 11b-703.7.2.1 international symbol of accessibility. §11b-502.6, figure
<br /> 11b-703.7.2.1
<br />18. signs identifying van parking spaces shall contain additional language or an additional sign with
<br /> the designation “van accessible.” signs shall be 60 inches minimum above the finish floor or
<br /> ground surface measured to the bottom of the sign. §11b-502.6
<br />19. parking identification signs shall be reflectorized with a minimum area of 70 square inches.
<br /> §11b-502.6.1
<br />20. additional language or an additional sign below the international symbol of accessibility shall
<br /> state “minimum fine $250.” §11b-502.6.2
<br />21. a parking space identification sign shall be visible from each parking space. signs shall be
<br /> permanently posted either immediately adjacent to the parking space or within the projected
<br /> parking space width at the head end of the parking space. signs may also be permanently posted
<br /> on a wall at the interior end of the parking space. §11b-502.6.3
<br />22. each accessible car and van space shall have surface identification complying with either of
<br /> the following schemes: §11b-502.6.4
<br /> a. the parking space shall be marked with an international symbol of accessibility complying with
<br /> section 11b-703.7.2.1 international symbol of accessibility in white on a blue background a
<br /> minimum 36 inches wide by 36 inches high. the centerline of the international symbol of
<br /> accessibility shall be a maximum of 6 inches from the centerline of the parking space, its sides
<br /> parallel to the length of the parking space and its lower corner at, or lower side aligned
<br /> with, the end of the parking space length. §11b-502.6.4.1
<br /> b. the parking space shall be outlined in blue or painted blue and shall be marked with an
<br /> international symbol of accessibility complying with section 11b-703.7.2.1 international symbol
<br /> of accessibility a minimum 36 inches wide by 36 inches high in white or a suitable contrasting
<br /> color. the centerline of the international symbol of accessibility shall be a maximum of
<br /> 6 inches from the centerline of the parking space, its sides parallel to the length of the
<br /> parking space and its lower corner at, or lower side aligned with, the end of the parking
<br /> space. §11b-502.6.4.2
<br />23. an additional sign shall be posted either; 1) in a conspicuous place at each entrance to an
<br /> off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible
<br /> from each parking space. §11b-502.8
<br /> a. the additional sign shall not be less than 17 inches wide by 22 inches high. §11b-502.8.1
<br /> b. the additional sign shall clearly state in letters with a minimum height of 1 inch the
<br /> following: §11b-502.8.2
<br /> "unauthorized vehicles parked in designated accessible spaces not displaying
<br /> distinguishing placards or special license plates issued for persons with disabilities
<br /> will be towed away at the owner…s expense. towed vehicles may
<br /> be reclaimed at: ____________________ or by telephoning______________________."
<br /> blank spaces shall be filled in with appropriate information as a permanent part of the sign.
<br />24. signs intended for use by pedestrians within parking facilities, including directional or
<br /> informational signs indicating parking sections or levels, shall comply with the requirements of
<br /> section 11b-216. §11b-216.5.2 relationship to accessible routes
<br />relationship to accessible routes
<br />25. parking spaces and access aisles shall be designed so that persons using them are not required
<br /> to travel behind parking spaces other than to pass behind the parking space in which they
<br /> parked. §11b-502.7.1
<br />26. a curb or wheel stop shall be provided if required to prevent encroachment of vehicles over the
<br /> required clear width of adjacent accessible routes. §11b-502.7.2 passenger drop-off & loading
<br /> zones and bus stops
<br />E.PLUMBING FIXTURES AND FACILITIES
<br />toilet and bathing room clearances
<br />13. where toilet facilities and bathing facilities are provided, they shall comply with 11b-213 toilet
<br /> facilities and bathing facilities. where toilet facilities and bathing facilities are provided in
<br /> facilities permitted by 11b-206.2.3 multi-story buildings and facilities exceptions 1 and 2 not to
<br /> connect stories by an accessible route, toilet facilities and bathing facilities shall be provided
<br /> on a story connected by an accessible route to an accessible entrance. §11b-213.1
<br />14. where separate toilet facilities are provided for the exclusive use of separate user groups, the
<br /> toilet facilities serving each user group shall comply with 11b-213 toilet facilities and bathing
<br /> facilities. §11b-213.1.1
<br />15. where toilet rooms are provided, each toilet room shall comply with 11b-603 toilet and bathing
<br /> rooms. where bathing rooms are provided, each bathing room shall comply with 11b-603 toilet and
<br /> bathing rooms. §11b-213.2 (see exception)
<br />16. unisex toilet rooms shall contain not more than one lavatory, and not more than two water
<br /> closets without urinals or one water closet and one urinal. unisex bathing rooms shall contain
<br /> one shower or one shower and one bathtub, one lavatory, and one water closet. doors to unisex
<br /> toilet rooms and unisex bathing rooms shall have privacy latches. §11b-213.2.1
<br />17. door shall not swing into the clear floor space or clearance required for any fixture. other
<br /> than the door to the accessible water closet compartment, a door in any position may encroach
<br /> into the turning space by 12 inches maximum. §11b-603.2.3
<br />18. at single user toilet or bathing rooms, doors shall be permitted to swing into the clear floor
<br /> space or clearance required for any fixture only if a 30 inch by 48-inch minimum clear floor
<br /> space is provided within the room beyond the arc of the door swing. §11b-603.2.3 (see exception)
<br />19. mirrors located above the lavatories or countertops shall be installed within the bottom edge
<br /> of the reflecting surface 40 inches maximum above the finish floor or ground. mirrors not
<br /> located above the lavatories or countertops shall be installed with the bottom edge of the
<br /> reflecting surface 35 inches maximum above the finish floor or ground. §11b-603.3
<br />20. coat hooks shall be located within one of the reach ranges specified in section 11b-308. shelves
<br /> shall be located 40inches minimum and 48 inches maximum above the finish floor. medicine
<br /> cabinets shall be located with a usable shelf no higher than 44 inches maximum above the finish
<br /> floor. §11b-603.4
<br />21. where towel or sanitary napkin dispensers, waste receptacles, or other accessories are provided
<br /> in toilet facilities, at least one of each type shall be located on an accessible route. all
<br /> operable parts, including coin slots, shall be 40 inches maximum above the finish floor. baby
<br /> changing stations are not required to comply with section 11b-603.5. §11b-603.5
<br />22. provide bathtub details, confirming compliance with section 11b-607, including the requirements
<br /> for clearances, grab bars, seats, controls, shower spray unit, and water and bathtub
<br /> enclosures. §11b-608
<br />23. provide details confirming disabled access compliance at shower compartments, including the
<br /> requirements for clearances, grab bars, seats, controls, shower spray unit and water,
<br /> thresholds, shower enclosures, shower floor or ground surface and soap dish. §11b-608
<br /> water closets and toilet compartments
<br />water closets and toilet compartments
<br />24. where toilet compartments are provided, at least 5 percent but no fewer than one toilet
<br /> compartment shall comply with section 11b-604.8.1. in addition to the compartments required to
<br /> comply with 11b-604.8.1, where six or more toilet compartments are provided, or where the
<br /> combination of urinals and water closets totals six or more fixtures, toilet compartments
<br /> complying with section 11b-604.8.2 shall be provided in the same quantity as the toilet
<br /> compartments required to comply with section 11b-604.8.1. §11b-213.3.1
<br />25. where water closets are provided, at least 5 percent but no fewer than one shall comply with
<br /> section 11b-604. §11b-213.3.2
<br />26. the clear width for accessible routes to accessible toilet compartments shall be 44 inches
<br /> except for door-opening widths and door swings. §11b-403.5.1 exception 5.
<br />27. the water closet shall be positioned with a wall or partition to the rear and to one side. the
<br /> centerline of the water closet shall be 17 inches minimum to 18 inches maximum from the side
<br /> wall or partition, except that the water closet shall be 17 inches minimum and 19 inches maximum
<br /> from the side wall or partition in the ambulatory accessible toilet compartment specified in
<br /> section 11b-604.8.2 ambulatory accessible compartments. water closets shall be arranged for
<br /> a left-hand or right-hand approach. §11b-604.2
<br />28. clearance around a water closet shall be 60 inches minimum measured perpendicular from the
<br /> sidewall and 56 inches minimum measured perpendicular from the rear wall. a minimum 60 inches
<br /> wide and 48 inches deep maneuvering space shall be provided in front of the water closet.
<br /> §11b-604.3.1
<br />29. the seat height of a water closet above the finish floor shall be 17 inches minimum and 19inches
<br /> maximum measured to the top of the seat. seats shall not be sprung the return to a lifted
<br /> position. seats shall be 2 inches high maximum and a 3-inch high seat shall be permitted only in
<br /> alterations where the existing fixture is less than 15 inches high. §11b-604.4
<br />30. the sidewall grab bars shall be 42 inches long minimum, located 12 inches maximum from the rear
<br /> wall and extending 54 inches minimum from the rear wall with the front end positioned 24 inches
<br /> minimum in front of the water closet. §11b-604.5.1
<br />31. the rear grab bar shall be 36 inches long minimum and extend from the centerline of the water
<br /> closet 12 inches minimum on one side and 24 inches minimum on the other side. §11b-604.5.2
<br /> (see exception)
<br />32. flush controls shall be hand operated or automatic. hand operated flush controls shall comply
<br /> with section 11b-309.4 operation except they shall be located 44 inches maximum above the floor.
<br /> flush controls shall be located on the open side of the water closet except in ambulatory
<br /> accessible compartments complying with section 11b-604.8.2 ambulatory accessible compartments.
<br /> §11b-604.6
<br />33. toilet paper dispensers shall comply with section 11b-309.4 operation and shall be 7 inches
<br /> minimum and 9 inches maximum in front of the water closet measured to the centerline of the
<br /> dispenser. the outlet of the dispenser shall be below the grab bar, 19 inches minimum above the
<br /> finish floor and shall not be located behind the grab bars. dispensers shall not be of a type
<br /> that control delivery or that does not allow continuous paper flow. §11b-604.7
<br />34. wheelchair accessible toilet compartments shall meet the requirements of sections 11b-604.8.1
<br /> wheelchair accessible compartments and 11b-604.8.3 coat hooks and shelves. compartments
<br /> containing more than one plumbing fixture shall comply with section 11b-603 toilet and bathing
<br /> rooms. ambulatory accessible compartments shall comply with sections 11b-604.8.2 ambulatory
<br /> accessible compartments and 11b-604.8.3 coat hooks and shelves. §11b-604.8
<br />35. in a wheelchair accessible compartment with an in-swing door, a minimum 60 inches wide by 36
<br /> inches deep maneuvering space shall be provided in front of the clearance required in section
<br /> 11b-604.8.1.1 wheelchair accessible compartment size. §11b-604.8.1.1.1, figures 11b-604.8.1.1.2(b)
<br /> and 11b-604.8.1.1.3(b)
<br />36. in a wheelchair accessible compartment with a door located in the side wall or partition, either
<br /> in-swinging or out swinging, a minimum 60 inches wide and 60 inches deep maneuvering space shall
<br /> be provided in front of the water closet. §11b-604.8.1.1.2, figure 11b-604.8.1.1.2
<br />37. in a wheel chair accessible compartment with end-opening door located in the front wall or
<br /> partition (facing water closet), either in-swinging or out-swinging, a minimum 60 inches wide and
<br /> 48 inches deep maneuvering space shall be provided in front of the water closet. §11b-604.8.1.1.3,
<br /> figure 11b-604.8.1.1.3
<br />38.toilet compartment doors, including door hardware, shall comply with section 11b-404 doors,
<br /> doorways, and gates except that if the approach is from the push side of the compartment door,
<br /> clearance between the door side of the compartment and any obstruction shall be 48 inches
<br /> minimum measured perpendicular to the compartment door in its closed position. door shall be
<br /> located in front partition or in the side wall or partition farthest from the water closet.
<br /> §11b-604.8.1.2
<br />39.where toilet compartment doors are located in the front partition, the door opening shall be
<br /> 4 inches maximum from the sidewall or partition farthest from the water closet. where located
<br /> in the sidewall or partition, the door opening shall be 4 inches maximum from the front partition
<br /> and the door shall be self-closing. §11b-604.8.1.2
<br />40.a door pull complying with section 11b-404.2.7 door and gate hardware shall be placed on both
<br /> sides of the door near the latch. door shall not swing into the clear floor space or clearance
<br /> required for any fixture. doors may swing into that portion of the maneuvering space which does
<br /> not overlap the clearance required at a water closet. §11b-604.8.1.2 (see exception)
<br />41.at least one side partition shall provide a toe clearance of 9 inches minimum above the finish
<br /> floor and 6 inches deep minimum beyond the compartment-side face of the partition, exclusive of
<br /> partition support members. partition components at toe clearances shall be smooth without
<br /> sharp edges or abrasive surfaces. compartments for children…s use shall provide a toe clearance
<br /> of 12 inches minimum above the finish floor. §11b-604.8.1.4
<br />42.ambulatory accessible compartments shall have a width of 35 inches minimum and 37 inches
<br /> maximum. §11b-604.8.2.1
<br />43.water closets and toilet compartments for children…s use shall comply with section 11b-604.9
<br /> water closets and toilet compartments for children…s use and follow suggested dimensions on
<br /> table 11b-604.9. §11b-604.9
<br />44.where urinals are provided, at least 10 percent but no fewer than one shall comply with section
<br /> 11b-605. §11b-213.3.3.
<br />45.urinals shall be the stall-type or the wall-hung type with the rim 17 inches maximum above the
<br /> finish floor or ground. urinals shall be 13½ inches deep minimum measured from the outer face
<br /> of the urinal rim to the back of the fixture. §11b-605.2
<br />46.flush controls shall be hand operated or automatic. hand operated flush controls shall comply
<br /> with section 11b-309 operable parts except that the flush control shall be mounted at a max.
<br /> height of 44 inches above the finish floor. §11b-605.4
<br />47.where lavatories are provided, at least 10 percent but no fewer than one shall comply with
<br /> section 11b-606 and shall not be located in a toilet compartment. §11b-213.3.4, §11b-606.1.
<br />48. for lavatories and sinks, a clear floor space complying with section 11b-305 clear floor or
<br /> ground surfaces, positioned for a forward approach, and knee and toe clearance complying with
<br /> section 11b-306 knee and toe clearance shall be provided. §11b-606.2
<br />49. lavatories and sinks shall be installed with the front of the higher of the rim or counter
<br /> surface 34 inches maximum above the finish floor or ground. §11b-606.3 signs related to toilets
<br /> and bathing facilities
<br />signs related to toilets and bathing facilities
<br />50. entrances leading to toilet rooms and bathing rooms complying with 11b-603 toilet and bathing
<br /> rooms shall be identified by a geometric symbol complying with 11b-703.7.2.6 toilet and bathing
<br /> room geometric symbols.
<br />51. where existing toilet rooms or bathing rooms do not comply with 11b-603 toilet and bathing
<br /> rooms, directional signs indicating the location of the nearest compliant toilet room or bathing
<br /> room within the facility shall be provided.
<br />52. signs shall comply with 11b-703.5 visual characters and shall include the international symbol
<br /> of accessibility complying with 11b-703.7.2.1 isa.
<br />53. where existing toilet rooms or bathing rooms do not comply with 11b-603 toilet and bathing
<br /> rooms, the toilet rooms or bathing rooms complying with 11b-603 toilet and bathing rooms shall
<br /> be identified by the international symbol of accessibility complying with 11b-703.7.2.1 isa.
<br />54. where clustered single user toilet rooms or bathing facilities are permitted to use exceptions
<br /> to 11b-213.2 toilet and bathing rooms, toilet rooms or bathing facilities complying with 11b-603
<br /> toilet and bathing rooms shall be identified by the international symbol of accessibility
<br /> complying with 11b-703.7.2.1 isa unless all toilet rooms and bathing facilities comply with 11b-603
<br /> toilet and bathing rooms.
<br />55. existing buildings that have been remodeled to provide specific toilet rooms or bathing rooms for
<br /> public use that comply with these building standards shall have the location of and the
<br /> directions to these rooms posted in or near the building lobby or entrance on a sign complying
<br /> with 11b-703.5 visual characters, including the international symbol of accessibility complying
<br /> with 11b-703.7.2.1 isa. §11b-216.8 washing machine and clothes dryers
<br />A-002
<br />NOTE :
<br />ISSUES & REVISIONS
<br />CONSULTANT :
<br />PROJECT :
<br />REVISION DESCRIPTIONDATENO.
<br />DESIGNED BY
<br />DRAWN BY
<br />CHECKED BY
<br />APPROVED
<br />TITLE
<br />SCALE
<br />PROJECT NO.
<br />DRAWING NO.
<br />SHEET NO.
<br />DATE
<br />EroomDesign Icn.EroomDesign Inc
<br />1411 ALBANY ST
<br />LOS ANGELES, CA 90015
<br />TELEPHONE 323-544-7688
<br />architecture interior & space design
<br />PR
<br />O
<br />J
<br />E
<br />C
<br />T
<br />:
<br />
<br />9
<br />4
<br />9
<br />
<br />G
<br />R
<br />I
<br />L
<br />L
<br />
<br />A
<br />N
<br />D
<br />
<br />P
<br />O
<br />T
<br />
<br />L
<br />O
<br />U
<br />N
<br />G
<br />E
<br />PR
<br />O
<br />J
<br />E
<br />C
<br />T
<br />
<br />A
<br />D
<br />D
<br />R
<br />E
<br />S
<br />S
<br />
<br />:
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />7
<br />2
<br />H
<br />U
<br />T
<br />T
<br />O
<br />N
<br />
<br />C
<br />E
<br />N
<br />T
<br />R
<br />E
<br />
<br />D
<br />R
<br />
<br />#
<br />2
<br />0
<br />4
<br />HANDICAP NOTE
<br />MAR. 2025
|