Laserfiche WebLink
Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />DARIAN <br />RADAC <br />NO. C-33451 <br />RENEWAL DATE <br />LICENSED <br />STA <br />OE <br />CETIHCRA <br />T <br />T <br />F <br />INR <br />I O <br />CALF <br />A2-28-2025 <br />Darian Radac <br />A-001 <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />Checker <br />Author <br />9-03-2024 <br />tom's2023 <br />Ge <br />n <br />e <br />r <br />a <br />l <br /> <br />N <br />o <br />t <br />e <br />s <br /> <br />& <br /> <br />S <br />p <br />e <br />c <br />i <br />f <br />i <br />c <br />a <br />t <br />i <br />o <br />n <br />s <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />1. THE INTENT OF THESE DOCUMENTS (I.E. SPECIFICATIONS, DRAWINGS, SCHEDULES) IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER <br />EXECUTION AND COMPLETION OF THE WORK BY THE CONTRACTOR. THESE DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY <br />ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL; PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE EXTENT <br />CONSISTENT WITH THESE DOCUMENTS AND REASONABLY INFERABLE FROM THEM AS BEING NECESSARY TO PRODUCE THE INTENDED <br />RESULTS. CONTRACTOR SHALL EXECUTE THE WORK IN AS EXPEDITIOUS A MANNER AS POSSIBLE. CONTRACTOR TO SUBMIT CONSTRUCTION <br />SCHEDULE AT START OF PROJECT AND PROVIDE MONTHLY UPDATES OF PROGRESS AND SCHEDULE. <br />APPROVAL OF A SUBSTITUTION BY THE ARCHITECT SHALL NOT BE CONSTRUED AS A CHECK FOR GENERAL CONFORMANCE WITH THE DESIGN <br />CONCEPT OF THE WORK AS EXPRESSED IN THE CONTRACT DOCUMENTS. THE OBLIGATION TO GUARANTEE DIMENSIONS AND QUANTITIES IS <br />SOLELY THAT OF CONTRACTOR. ALL DRAWINGS/SPECIFICATIONS ARE ADDITIVE AND COMPLEMENT EACH OTHER WITH RELATED INFORMATION <br />CONTRACTOR TO PROVIDE ALL TRADES/SUBCONTRACTORS ALL DRAWINGS AND SPECIFICATIONS AND VERIFY ANY DISCREPANCIES BEFORE <br />PROCEEDING WITH CONSTRUCTION. CONTACT ARCHITECT IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. <br />THE FOLLOWING NOTES PRE MINIMUM REQUIREMENTS IF A MORE STRINGENT SPECIFICATION OR CONDITION OCCURS ON THE CONSULTANT <br />SET OF DRAWINGS THE MORE STRINGENT OF THE TWO WILL APPLY. UPON WRITTEN APPROVAL BY THE ARCHITECT. <br />CONTRACTOR SHALL ADVISE ARCHITECT AND OWNER IN WRITING OF ANY RECOMMENDED CHANGES TO THE FOLLOWING NOTES AND <br />SPECIFICATIONS AND SHALL SUBMIT WRITTEN CONFIRMATION TO ARCHITECT OF ANY CHANGES AND RECEIVE ARCHITECT'S WRITTEN <br />APPROVAL PRIOR TO ORDERING OR INSTALLATION. THE ARCHITECT WILL IN NO WAY BE RESPONSIBLE FOR HOW THE WORK IS PERFORMED, <br />SAFE IN, ON, OR ABOUT THE JOB SITE, MANNER AND METHODS OF PERFORMANCE OR TIMELINESS IN THE PERFORMANCE OF THE WORK. <br />2. "CONTRACTOR" REFERS TO BOTH THE GENERAL CONTRACTOR, HIS AGENTS AND SUBCONTRACTORS. "ARCHITECT" REFERS TO THE <br />ARCHITECT OF RECORD OR HIS AGENT. CONSTRUCTION DOCUMENTS REFERS TO THESE GENERAL REQUIREMENT/NOTES, SPECIFICATIONS, <br />DRAWINGS, INFORMATION/INSTRUCTIONS PROVIDED/ AVAILABLE TO BIDDERS, BID FORMS AND SUPPLEMENTS, ADDENDA, CONTRACT <br />DOCUMENTS, CONTRACT FORMS, CONDITIONS OF THE CONTRACT, MODIFICATIONS, AND SUPPLEMENTAL INFORMATION AND WRITTEN <br />DIRECTIVES PROVIDED BY THE ARCHITECT AND DESIGN TEAM/CONSULTANTS. <br />3. CONTRACTOR/SUBCONTRACTORS SHALL FURNISH AND INSTALL ALL ITEMS NECESSARY TO COMPLETE THE WORK IN ACCORDANCE WITH <br />GOOD BUILDING PRACTICE AND INDUSTRY STANDARDS WHETHER SPECIFICALLY CALLED FOR OR NOT ON THE CONSTRUCTION DOCUMENTS. <br />COMPLY WITH ALL ENVIRONMENTAL CONTROL REGULATIONS IN EFFECT. MANUFACTURER RECOMMENDATIONS ON ANY PRODUCT USED ON OR <br />IN CONJUNCTION WITH THIS PROJECT SHALL BE STRICTLY FOLLOWED UNLESS THEY ARE IN CONTRADICTION WITH THE DRAWINGS AND <br />SPECIFICATIONS. IF THIS OCCURS NOTIFY ARCHITECT IN WRITING IMMEDIATELY. <br />THE 1987 EDITION OF THE AIA DOCUMENT A701 "INSTRUCTION TO BIDDERS" IS A PART OF THE CONSTRUCTION DOCUMENTS AND SHALL GOVERN <br />THE BIDDING PROCESS. THE 1987 EDITION OF THE AIA DOCUMENT A201 "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" IS A <br />PART OF THE CONSTRUCTION DOCUMENTS AND SHALL GOVERN THE WORK. <br />4. CONTRACTOR SHALL PROVIDE A JOBSITE FAX AND JOBSITE PHONE WHICH SHALL BE AVAILABLE FOR USE 24 HOURS EACH DAY. <br />5. ALL CONSTRUCTION AND DETAILS SHALL BE COMPLETED IN FULL COMPLIANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL CODES AND <br />REQUIREMENTS, INCLUDING CURRENT AMERICANS WITH DISABILITIES ACT (ADA), AND TITLE 24 ENERGY REQUIREMENTS. IT IS THE <br />CONTRACTOR'S ULTIMATE RESPONSIBILITY TO CONSTRUCT THE PROJECT AS PER THESE CODES. <br />6. PRIOR TO FINALIZING CONTRACT PRICES, CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NOTES AND <br />DRAWINGS TO INCLUDE ANY SUBCONTRACT REQUIREMENTS OR INFORMATION WHICH MAY NOT BE INDICATED ON SUBCONTRACTOR'S SHEETS <br />OR NOTES, BUT WHICH ARE INDICATED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. <br />7. CONTRACTOR SHALL VERIFY ALL WORKS, DIMENSIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO THE OWNER AND ARCHITECT <br />PRIOR TO COMMENCING WORK. DURING CONSTRUCTION, THE OWNER AND ARCHITECT ARE TO BE ADVISED REGARDING ANY DISCREPANCIES <br />IN MEASUREMENT, DIMENSION, LOCATION OR DETAILS PRIOR TO CONTRACTOR'S PROCEEDING WITH THAT PORTION OF THE WORK. <br />8. CONTRACTOR SHALL CONSULT REPRESENTATIVES OF LOCAL UTILITIES, INCLUDING GAS, WATER, POWER, SEWER, TELEPHONE AND TV <br />WHERE APPLICABLE CONCERNING LOCATIONS AND AVAILABILITY OF UTILITIES PRIOR TO COMMENCING WORK OR CONNECTING UTILITIES, AND <br />SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITY LINES. <br />9. CONTRACTOR SHALL VERIFY ON SITE THE LOCATIONS, DEPTH AND ELEVATIONS OF ALL EXISTING UTILITIES AND SERVICES BEFORE <br />PERFORMING ANY WORK. WORK SHALL INCLUDE ALL SITE WORK AND UTILITY HOOKUPS AS CONDITIONS REQUIRE. CONTRACTOR SHALL <br />RECORD LOCATIONS AND ELEVATIONS OF ALL EXISTING AND NEW UTILITY LINES, MAINS, AND METERS ON SITE PLAN SEPIA AND DELIVER TO <br />ARCHITECT ON COMPLETION OF CONSTRUCTION. <br />10. THESE CONSTRUCTION DOCUMENTS ARE BASED ON OBSERVATION AND DOCUMENTATION OF EXISTING CONDITIONS BY THE ARCHITECT, <br />SURVEYOR, AND/OR FROM DOCUMENTS PROVIDED BY THE OWNER. THE ARCHITECT MAKES NO CLAIM TO THE ACCURACY OF SUCH <br />OBSERVATION. SHOULD THE CONTRACTOR ENCOUNTER FIELD CONDITIONS WHICH VARY FROM THESE CONSTRUCTION DOCUMENTS AND <br />WHICH EFFECT THE INTENT OF THESE DRAWINGS OR THE CONTRACT SUM, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY. CONTRACTOR <br />SHALL VISIT THE SITE AND VERIFY ALL CONDITIONS, DIMENSIONS AND ELEVATIONS AND REPORT ALL DISCREPANCIES TO THE ARCHITECT <br />BEFORE THE COMMENCEMENT OR WORK. IF THE CONTRACTOR FAILS TO REPORT ANY SUCH DISCREPANCIES TO THE ARCHITECT THE COST OF <br />ANY CORRECTIVE WORK WHICH RESULTS FROM THIS FAILURE SHALL BE PAID FOR BY THE CONTRACTOR AT NO COST TO THE OWNER AND/OR <br />ARCHITECT. <br />11. WRITTEN DIMENSIONS SHALL PREVAIL OVER SCALED DIMENSIONS ON DRAWINGS. IN NO EVENT IS A DIMENSION TO BE SCALED OFF THE <br />DRAWINGS WITHOUT PRIOR APPROVAL FROM ARCHITECT. <br />CONTRACTOR/SUBCONTRATORS SHALL BE HELD RESPONSIBLE FOR HIS/THEIR WORK. ALL DIMENSIONS SHALL BE FIELD VERIFY WHERE <br />POSSIBLE. ALL DIMENSIONS ARE TO FACE OF STUD/FACE OF CONCRETE WALL UNLESS OTHERWISE INDICATED. <br />12. DETAILS ARE INTENDED TO SHOW FINAL EFFECT OF PARTS OF CONSTRUCTION. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT <br />PARTICULAR JOB SITE DIMENSIONS OR CONDITIONS AND SHALL BE INCLUDED WITHIN THE SCOPE OF THE WORK AND CONSTRUCTION <br />CONTRACT. ANY MODIFICATIONS REQUIRED IN DETAILS ARE TO BE FIRST REVIEWED AND CONFIRMED WITH THE ARCHITECT PRIOR TO <br />CONSTRUCTION. <br />13. CONTRACTOR SHALL KEEP PREMISES SECURE, CLEAN, AND HAZARD FREE. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING HIS <br />EQUIPMENT, MATERIALS, AND WORK IN NEAT, CLEAN, ORDERLY, AND SAFE CONDITION AT ALL TIMES. <br />14. CONTRACTOR SHALL ERECT AND MAINTAIN TEMPORARY BARRICADES, WATERPROOFING, AND DUST-PROOF PARTITIONS AS NEEDED FOR <br />PROTECTION AGAINST ACCIDENT, AND SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF HIS WORK AND THE OWNER'S PROPERTY <br />FROM DAMAGE OR LOSS ARISING IN CONNECTION WITH CONSTRUCTION. <br />15. TRADES SHALL FURNISH ALL LABOR, EQUIPMENT, MATERIALS AND SERVICES REQUIRED TO PERFORM ALL WORK NECESSARY, INDICATED, <br />REASONABLE INFERRED, OR REQUIRED BY ANY CODE WITH JURISDICTION TO COMPLETE THEIR SCOPE OF WORK FOR A COMPLETED AND <br />PROPERLY JOB USING ONLY NEW MATERIALS U.O.N. IN ACCORDANCE WITH THE BEST ACCEPTED STANDARDS OF WORKMANSHIP. ALL F.B.O. <br />(FURNISHED BY OWNER) THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE BUILDING LINES, BUILDING AND SITE <br />ELEVATIONS, AND LEVELS. THE CONTRACTOR SHALL COMPARE CAREFULLY THE LINES, ELEVATIONS, AND LEVELS SHOW ON THE DRAWINGS <br />WITH EXISTING LEVELS, GRADES AND ELEVATIONS FOR THE LOCATION AND CONSTRUCTION OF THE WORK AND SHALL CALL THE ARCHITECT'S <br />ATTENTION TO ANY DISCREPANCIES FOR BORE PROCEEDING WITH THE WORK. <br />SHOP AND FIELD WORK SHALL BE PERFORMED BY MECHANICS, CRAFTSMEN, AND WORKERS SKILLED AND EXPERIENCED AND LICENSED IN THE <br />FABRICATION AND INSTALLATION OF THE WORK INVOLVED. ALL WORK ON THIS PROJECT SHALL BE PERFORMED IN ACCORDANCE WITH THE <br />BEST ACCEPTED PRACTICES AND STANDARDS OF THE VARIOUS TRADES INVOLVED AND IN ACCORDANCE WITH THE DRAWINGS, REVIEWED <br />SHOP DRAWINGS, STANDARDS. RECOMMENDATIONS ESTABLISHED BY APPLICABLE TRADE ASSOCIATIONS, AND THESE SPECIFICATIONS. THE <br />ARCHITECT RESERVES THE RIGHT TO REJECT ANY MATERIALS AND WORK QUALITY WHICH ARE NOT CONSIDERED TO BE UP TO THE HIGHEST <br />STANDARDS OF THE VARIOUS TRADES INVOLVED. SUCH INFERIOR MATERIAL OR WORK QUALITY SHALL BE REPAIRED OR REPLACED, AS <br />DIRECTED, AT NO ADDITIONAL COST TO THE OWNER. <br />16. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING IN GOOD CONDITION ANY PORTIONS OF THE SITE TO REMAIN AND SHALL REPLACE <br />OR REPAIR AT HIS EXPENSE ANY PORTIONS DAMAGED AS A RESULT OF THE WORK, CONSTRUCTION PROCESS OR EXPOSURE TO <br />WEATHER.PRIOR TO COMMENCING CONSTRUCTION, THE EXISTING SITE IS TO BE CLEARED OF ALL SURFACE AND SUBSURFACE CONCRETE AND <br />DEBRIS THAT INTERFERES WITH THE STRUCTURE OR SITE WORK. PRESERVE AND PROTECT EXISTING VEGETATION WHICH IS TO REMAIN AS <br />DIRECTED BY THE OWNER. DO NOT STACK ANY CONSTRUCTION MATERIALS WITHIN 10' OF EXISTING TREES. EXCAVATE AND ROUGH GRADE <br />SITE TO ACHIEVE ELEVATIONS SHOWN. SHORE ALL EXCAVATIONS AS NECESSARY TO PREVENT COLLAPSE OR EROSION. MAINTAIN SAFE <br />CONDITIONS DURING ENTIRE PERIOD THAT EXCAVATION IS OPEN, INCLUDING NON WORK HOURS. JOBSITE SAFETY IS SOLELY THE <br />CONTRACTOR'S RESPONSIBILITY. SHORING DESIGN / SHORING / DEMOLITION IS THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE <br />ENGINEERED IF REQUIRED. <br />17. CONTRACTOR SHALL PROVIDE AND MAINTAIN TEMPORARY TOILET FACILITIES ON THE JOB SITE. <br />18. CONTRACTOR SHALL REVIEW ALL ITEMS NOTED "VERIFY OR CONFIRM WITH OWNER OR ARCHITECT" WHICH MIGHT AFFECT COSTS PRIOR TO <br />FINALIZING CONSTRUCTION CONTRACT AND SUBCONTRACTS, AND SHALL CONFIRM FINAL DECISIONS REGARDING SELECTION, MATERIALS, <br />COLOR FINISH OR OTHER SPECIFICATIONS NOT YET DECIDED REGARDING THESE ITEMS. CONTRACTOR SHALL INCLUDE THE COST OF THESE <br />ITEMS WITHIN THE ORIGINAL CONTRACT PRICE. <br />19. UNLESS ITEMS ARE SPECIFICALLY ITEMIZED AS NOT INCLUDED IN CONTRACT (NIC), THEY WILL BE ASSUMED TO BE INCLUDED IN THE <br />ESTIMATE OR CONTRACT PRICE. <br />20. ANY ALLOWANCE ITEMS SHALL BE SPECIFICALLY IDENTIFIED AS ALLOWANCES AND INCLUDED IN THE ESTIMATE OR CONTRACT PRICE. <br />21. PRODUCTS SPECIFIED OR INDICATED ON DRAWINGS ARE PRODUCTS DESIRED BY OWNER AND ARCHITECT AND SHALL BE UTILIZED UNLESS <br />CONTRACTOR OBTAINS ARCHITECT'S AND OWNER'S ACCEPTANCE IN WRITING OF ANY SUBSTITUTIONS. <br />22. NO PRODUCT WILL BE CONSIDERED AFTER BID TIME, OTHER THAN THAT WHICH HAS BEEN SPECIFIED, WITHOUT ARCHITECT'S AND OWNER'S <br />APPROVAL. CONTRACTOR CAN REQUEST A SUBSTITUTION IN WRITTEN FORM NO LATER THAN THIRTY (30) DAYS AFTER START OF <br />CONSTRUCTION. THE LETTER SHALL GIVE THE REASONS AND JUSTIFICATIONS FOR THE REQUEST FOR SUBSTITUTION, INCLUDING ANY <br />ADJUSTMENTS TO COST. SUBSTITUTIONS ARE SUBJECT TO ARCHITECT'S REVIEW. CONTRACTOR SHALL WARRANT THAT SUBSTITUTIONS ARE <br />ACCEPTABLE BY GOVERNING AUTHORITIES. <br />23. THE GENERAL CONTRACTOR SHALL REIMBURSE ARCHITECT FOR LABOR AND OTHER COSTS INVOLVED IN PROVIDING, RESEARCH, <br />ADDITIONAL DRAWINGS, DETAILS, OR ENGINEERING TO REVIEW SUBSTITUTIONS OR TO ADJUST THE DESIGN OR CONSTRUCTION DOCUMENTS <br />DUE TO ERRORS, CHANGES, OR SUBSTITUTIONS MADE BY CONTRACTORS DURING CONSTRUCTION. SUCH REIMBURSEMENTS SHALL NOT BE <br />INCLUDED IN THE PROJECT CONSTRUCTION COST AND SHALL BE PAID BY THE CONTRACTOR WITHOUT REIMBURSEMENT FROM THE OWNER. <br />24. SUBSTITUTIONS REQUESTED ON BASIS OF DELIVERY DATES THAT MAY CAUSE PROJECT'S COMPLETION DATE TO BE DELAYED, DUE TO <br />CONTRACTOR'S TARDINESS IN NOT ORDERING THE SPECIFIED PRODUCT ON TIME, WILL NOT BE CONSIDERED. <br />25. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER OF ANY EXTRA COSTS ARISING FROM THE EXECUTION OF HIS CONTRACT OR <br />SUBCONTRACTS AND SHALL RECEIVE OWNER'S WRITTEN APPROVAL OF SAME PRIOR TO DOING THE WORK. <br />THE OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK. THE CONTRACT SUM <br />SHALL BE ADJUSTED ACCORDINGLY. CHANGES OR ALTERATIONS, ETC. SHALL BE REVIEWED BY THE ARCHITECT PRIOR TO THE START OF THIS <br />WORK. CHANGES NOT IN WRITING WILL NOT BE PAID/REIMBURSED. <br />26. CONTRACTOR SHALL BE RESPONSIBLE FOR SUPERVISING THAT ALL GENERAL AND SUBCONTRACT WORK IS BEING ACCOMPLISHED <br />ACCORDING TO THE MOST CURRENT CONSTRUCTION DOCUMENTS, INCLUDING REVISIONS. <br />27. THE CONTRACTOR SHALL CARRY IN FORCE ALL NEEDED INSURANCE, LICENSES, FEES, PERMITS, TAXES AS REQUIRED BY LAW FOR THE <br />DURATION OF THE PROJECT. THE CONTRACTOR SHALL MAINTAIN WORKMAN'S COMPENSATION, COMPREHENSIVE LIABILITY AND PERSONAL <br />INJURY TO PROTECT HIMSELF AND HOLD THE OWNER AND THE ARCHITECT HARMLESS FROM ANY AND ALL CLAIMS FOR DAMAGES, FOR <br />PERSONAL BODILY INJURY OR DEATH, OR PROPERTY DAMAGE, DURING THE COURSE OF THIS CONTRACT. THIRTY DAYS WRITTEN NOTICE OF <br />CANCELLATION SHALL BE PROVIDED TO THE OWNER ON EACH OF THE ABOVE POLICIES. (FIRE INSURANCE SHALL BE MAINTAINED BY THE <br />OWNER). $1,000,000 LIABILITY INSURANCE REQUIRED. ALL OF THE ABOVE POLICIES SHALL LIST CONTRACTOR IS PRIMARY TO ANY OTHER <br />INSURANCE CARRIED BY OWNER AND ARCHITECT. UNLESS OTHER ARRANGEMENTS ARE MADE, OWNER SHALL PROVIDE ADEQUATE PROPERTY <br />AND LIABILITY INSURANCE IN ADDITION TO CONTRACTOR'S INSURANCE TO COVER ALL NEW WORK. THIS INSURANCE SHALL INCLUDE THE <br />INTERESTS OF THE OWNER AND CONTRACTOR IN THE WORK, BUT SHALL NOT RELIEVE CONTRACTOR OF HIS RESPONSIBILITIES UNDER THE <br />CONTRACT OR AS ITEMIZED ABOVE. <br />28. CONTRACTOR SHALL NOT USE ANY POTENTIALLY HAZARDOUS MATERIALS OR PRODUCTS IN THE CONSTRUCTION, AND SHALL ADVISE <br />OWNER OF ANY POTENTIALLY HAZARDOUS MATERIALS OR PRODUCTS RECOMMENDED, SELECTED OR SPECIFIED PRIOR TO PURCHASING OR <br />INSTALLING. <br />29. CONTRACTOR SHALL PROVIDE PROPER VENTILATION, CLEARANCES AND FIRE PROTECTION FOR ALL NEW FIREPLACES, OVENS, HOT WATER <br />HEATERS, FURNACES, VENTS AND FLUES AS REQUIRED BY THE DRAWINGS, SPECIFICATIONS AND CODE. <br />30. CONTRACTOR IS TOTALLY RESPONSIBLE FOR DELIVERING A WATERPROOF/WATERTIGHT PROJECT. ALL DETAILS AND CONDITIONS ON <br />PLANS SHALL BE REVIEWED BY CONTRACTOR BEFORE CONSTRUCTION. ARCHITECT SHALL BE NOTIFIED OF ANY CONDITIONS THAT MAY <br />PRESENT A WATERPROOFING PROBLEM. <br />31. ALL DEMOLITION SHALL BE DONE SAFELY AND IN A MANNER APPROPRIATE TO ANTICIPATE CONSTRUCTION. ALL DEMOLITION SHALL BE <br />DONE IN A MANNER WHICH PROTECTS ADJOINING PROPERTY. DURING DEMOLITION NO MATERIALS SHALL BE STORED ON ANY FLOOR IN <br />EXCESS OF THE ALLOWABLE LIVE LOAD FOR THAT FLOOR. DURING DEMOLITION ALL DEBRIS SHALL BE SUFFICIENTLY WET AT THE TIME OF <br />HANDLING TO PREVENT DUST FROM ARISING. MATERIALS CLASSIFIED AS DEMOLITION SHALL BE REMOVED FROM THE SITE BY CONTRACTOR. <br />REMOVE ALL EXISTING OBSOLETE ELECTRICAL, SECURITY, TELEPHONE EQUIPMENT AND WIRING. PROVIDE SHORING SYSTEM DURING <br />DEMOLITION AND CONSTRUCTION AS REQUIRED TO PROTECT WORKMEN, MATERIALS, REMAINING BUILDINGS/IMPROVEMENTS, OTHER <br />PROPERTIES, AND THE PUBLIC. <br />32. CONTRACTOR SHALL PROVIDE FOR ALL NECESSARY PERMITS AND INSPECTIONS OTHER THAN PLAN CHECK AND BUILDING PERMIT FEES <br />WHICH ARE TO BE PROVIDED BY THE OWNER. SUBCONTRACTORS ARE TO PAY FOR SUBTRADE PERMITS IN THEIR CONTRACTS. <br />33. CONTRACTOR SHALL PROVIDE SUFFICIENT MEANS FOR PROTECTING EXISTING EXPOSED INTERIOR AND EXTERIOR FINISHES, NEW AND <br />EXISTING CONSTRUCTION AND MATERIALS FROM DAMAGE BY OTHER TRADES, WEATHER, OR VANDALS FOR THE COURSE OF THE PROJECT. <br />THE COST OF SAID PROTECTION SHALL BE INCLUDED IN THE BASE BID. SUBCONTRACTORS AND CONTRACTOR ARE TO ASSUME <br />RESPONSIBILITY UNTIL OWNER TAKES POSSESSION OF PROPERTY. CONTRACTOR SHALL PROVIDE ALL BARRICADES, FENCES, AND OTHER <br />ITEMS REQUIRED BY LOCAL ORDINANCES AND CODES. <br />34. PRODUCTS SHALL BE DELIVERED IN MANUFACTURER'S ORIGINAL CONTAINERS OR PACKAGING, WITH IDENTIFYING LABELS. <br />IN THE EVENT OF DAMAGE, IMMEDIATELY MAKE REPAIRS/REPLACEMENTS AS NECESSARY TO THE APPROVAL OF THE ARCHITECT <br />AND NO ADDITIONAL COST TO THE OWNER. STORE PRODUCTS IN ACCORDANCE TO THE MANUFACTURE'S INSTRUCTIONS, WITH <br />SEALS AND LABELS INTACT AND LEGIBLE. PROTECT PRODUCTS FROM DAMAGE BY THE ELEMENTS, CONDENSATION, <br />TEMPERATURE CHANGES, ETC. FABRICATED PRODUCTS SHALL BE STORED ABOVE THE GROUND. ARRANGE STORAGE TO <br />PROVIDE EASY ACCESS FOR INSPECTION. DO NOT OVERLOAD BUILDING OR ANY PART OF THE WORK UNDER CONSTRUCTION, OR <br />EXISTING STRUCTURES. CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE WORK AND PROPERTY DURING RAIN AT NO <br />ADDITIONAL COST TO THE OWNER. <br />35. DEPUTY INSPECTIONS ARE BY CODE THE RESPONSIBILITY OF THE OWNER. THE CONTRACTOR SHALL NOT EMPLOY DEPUTY <br />INSPECTORS. INCLUDING BUT NOT LIMITED TO: FIELD W ELDING / HIGH STRENGTH BOLTING / CONCRETE IN EXCESS OF 2,500 <br />P.S.I. / GRADE BEAMS / RETAINING WALLS. <br />36. CONTRACTOR SHALL PROVIDE THE OWNER WITH RECORD DRAWINGS INDICATING ALL ARCHITECTURAL, STRUCTURAL AND <br />DIMENSIONAL CHANGES AND INDICATING THE LOCATION AND SIZE OF ALL UNDERGROUND CHANGES AND THE LOCATIONS OF ALL <br />UNDERGROUND INSTALLATIONS NOT COVERED IN ORIGINAL DRAWINGS, CHANGE ORDERS, SUPPLEMENTAL DRAWINGS OR IN <br />SHOP DRAWINGS. THE CONTRACTOR SHALL SUBMIT COMPLETED RECORD DRAWINGS TO THE ARCHITECT FOR HIS REVIEW. <br />SUCH REVIEW SHALL NOT RELIEVE CONTRACTOR OF HIS RESPONSIBILITIES FOR THE ACCURACY OR COMPLETENESS OF THE <br />INFORMATION RECORDED. <br />37. ALL WATERPROOFING SUBCONTRACTORS MUST BE FACTORY CERTIFIED/APPROVED APPLICATORS. <br />38. ALL WATERPROOFING SUBCONTRACTORS MUST PROVIDE WARRANTY IN WRITING FOR NO LESS THAN 10 YEARS. <br />39. ALL WATERPROOFING PERFORMED ON THE PROJECT MUST BE INSPECTED BY FACTORY AUTHORIZED <br />REPRESENTATIVE/EMPLOYEE PRIOR TO BEING BACKFILLED OR COVERED. PROOF AND CERTIFICATION OF SUCH INSPECTION <br />MUST BE PROVIDED TO THE GENERAL CONTRACTOR. <br />B. SHOP DRAWINGS/ SAMPLES SEE DETAIL 7 SERIES FOR SHOP DRAWINGS REQUIREMENTS INCL S.E. PLANS <br />C. SITEWORK, DEMOLITION, FOUNDATIONS, ETC. <br />1. PRIOR TO FORMING AND POURING CONCRETE, CONTRACTOR SHALL STAKE OUT ALL FOUNDATIONS AND PERIMETER WALL <br />LINES AS SHOWN ON PLANS FOR ARCHITECT'S REVIEW, CONFIRM EXISTING AND NEW STRUCTURE AND PROPERTY LINE <br />LOCATIONS AND ELEVATIONS, AND VERIFY PROPER SETBACKS AND CLEARANCES REQUIRED BY LOCAL CODES. <br />2. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5' OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND, <br />OR OBTAIN NECESSARY PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY PRIOR TO ISSUANCE OF A <br />BUILDING OR GRADING PERMIT. (HSC 17922.5, EFF. 3/6/76). FOLLOW ALL OSHA RULES AND GUIDELINES CALL DIGALERT. <br />3. CONTRACTOR SHALL NOTIFY ARCHITECT AND OWNER OF ANY UNSTABLE OR QUESTIONABLE SOIL OR GEOLOGICAL <br />CONDITIONS ENCOUNTERED DURING EXCAVATION. <br />4. WHERE A SOILS AND/OR GEOLOGY REPORT AND/OR GRADING PRE-INSPECTION REPORT HAS BEEN MADE, THEY SHALL BE <br />CONSIDERED A PART OF THE CONSTRUCTION DOCUMENTS, AND CONTRACTOR SHALL FOLLOW ANY RECOMMENDATIONS <br />CONTAINED THEREIN. <br />5. CONTRACTOR SHALL PROVIDE BASEMENT AND CRAWL SPACE ACCESS AND VENTILATION TO ALL SUBFLOOR AREAS IN <br />ACCORDANCE WITH LOCAL CODES AND CONFIRM FOUNDATION VENT LOCATIONS WITH ARCHITECT PRIOR TO POURING <br />FOUNDATIONS. <br />6. WHERE INTERIOR CRAWL SPACE OR ROOM, PIT OR BASEMENT FLOOR SLABS ARE BELOW EXTERIOR FINISH GRADE, <br />CONTRACTOR SHALL PROVIDE DRAINAGE AT FOOTING PERIMETER AND W.R GRACE BITUTHENE SYSTEM 4000 LARR #243864 OR <br />EQUAL WATERPROOFING OF ALL EXTERIOR SURFACES OF FOUNDATION RETAINING WALLS. DRAINAGE SHALL CONSIST OF 4" <br />DIAMETER PVC PERFORATED PIPE SET BELOW FLOOR LINE, SLOPED TO DRAIN, AND CONNECTED UNDERGROUND TO APPROVED <br />STORM DRAINAGE SYSTEM OR STREET. PIPE SHALL BE SURROUNDED WITH 2 FEET OF 3/4" WASHED GRAVEL AND TOPPED WITH <br />A FILTRATION FABRIC. DIRECTION OF HOLES IN PIPE SHOULD FACE DOWNWARD. PROTECT WALL WATERPROOFING WITH 1/2" <br />RIGID MINERAL FIBER INSULATION BOARD AND BACKFILL WITH SAND AND GRAVEL OR AN APPROVED SUBSTITUTE SUCH AS <br />MIRADRAIN. <br />7. ALL CONCRETE FLOOR SLABS SHALL BE POURED OVER 2" OF SAND OVER A CONTINUOUS 10 MIL WATERPROOF MEMBRANE <br />(SEE SOILS REPORT) OVER 4" CRUSHED ROCK ON NATURAL OR COMPACTED SOIL. FOR SLABS SET BELOW EXTERIOR GRADES, <br />THE CRUSHED ROCK BED SHALL BE DRAINED TO STORM DRAIN SYSTEM OR RELIEVED AT PERIMETER WITH A PERFORATED PIPE <br />CONNECTED TO APPROVED STORM DRAIN SYSTEM OR STREET TO PREVENT SUBFLOOR SATURATION. <br />8. ANY LANDSCAPE OR PLANTER RETAINING WALLS AGAINST EARTH WHICH ARE SPECIFIED WITHOUT PERIMETER DRAIN SHALL <br />BE PROVIDED WITH ADEQUATE WEEP HOLES SURROUNDED ON THE BACKSIDE BY A MINIMUM 6" OF GRAVEL BACKFILL AT BASE <br />OF WALL, THE BACK OF THE WEEP HOLES SHALL BE COVERED WITH FILTER FABRIC. ALL ENCLOSED PLANTERS SHALL BE <br />WATERPROOFED ON THE INSIDE AND SUPPLIED WITH BOTTOM DRAINS CONNECTED TO STORM DRAIN SYSTEM. <br />9. ALL CONCRETE SLABS TO BE REMOVED SHALL FIRST BE NEATLY SAWCUT WITH NO OVERCUTTING. <br />10. PATCHING OF CONCRETE SLABS SHALL BE PERFORMED SO AS TO LEAVE THE PATCH SURFACE LEVEL WITH AND MATCHING <br />THE EXISTING ADJACENT SLAB. <br />11. CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE OF ALL FINISHED GRADE SURFACES, SIDEWALKS AND PATIOS AWAY <br />FROM STRUCTURES AND VERIFY THAT ALL AREAS AFFECTED BY CONSTRUCTION ARE PROPERLY DRAINED, WITH NO PONDING. <br />12. CONTRACTOR SHALL REMOVE ALL EXCAVATED OR EXCESS SOIL, DEBRIS AND MATERIALS NOT REQUIRED BY CONSTRUCTION. <br />CONFIRM ANY ITEMS TO REMAIN, OR TO BE SALVAGED WITH ARCHITECT AND OWNER PRIOR TO START OF CONSTRUCTION. <br />D. FRAMING, ETC.. - REFER TO STRUCTURAL ENGINEER PLANS, SPECS PROVIDED ARE A GENERAL GUIDE <br />1. CONTRACTOR SHALL REMOVE AND REPLACE ALL TERMITE DAMAGED OR INFESTED WOOD IN ALL PORTIONS OF EXISTING <br />STRUCTURE TO REMAIN. VERIFY WITH OWNER AND ARCHITECT IF QUESTIONABLE. <br />2. IN ADDITION TO ANY STRUCTURAL GRADE REQUIREMENTS, ALL EXPOSED WOOD BEAMS AND POSTS SHALL BE SELECTED FOR <br />BEST APPEARANCE GRADE, WITH A MINIMUM OF KNOTS, CRACKS AND CHECKS. <br />3. CONTRACTOR SHALL PROVIDE ACCESS TO ALL ATTIC AREAS AND PLUMBING AS REQUIRED BY CODE AND SHALL CONFIRM <br />ACCESS LOCATIONS WITH ARCHITECT PRIOR TO FRAMING. <br />4. CONTRACTOR SHALL PROVIDE SCREENED THROUGH-WALL VENTILATION TO ENCLOSED GARAGE AREAS IF REQUIRED BY CODE <br />AND SHALL CONFIRM VENT LOCATIONS WITH ARCHITECT PRIOR TO FRAMING. <br />5. CONTRACTOR SHALL COORDINATE FRAMING WITH PROPOSED LOCATIONS OF ELECTRICAL, MECHANICAL AND PLUMBING WORK <br />SO AS TO AVOID CHANGES IN FRAMING WHICH MIGHT CONFLICT WITH PROPOSED EQUIPMENT, FIXTURE OR DIFFUSER <br />LOCATIONS. <br />6. PROVIDE FRAMED OPENINGS FOR MEDICINE CABINETS DURING ROUGH FRAMING, CONFIRMING SIZE, LOCATION AND HEIGHTS <br />OF OPENINGS WITH ARCHITECT PRIOR TO CONSTRUCTION. <br />7. PROVIDE SOLID BLOCKING AT ALL CURBS, CANT STRIPS, LIGHTS, TRIM, GYPSUM BOARD AND PLASTER ACCESSORIES, SHEET <br />METAL FLASHING, RAILINGS AND ANY OTHER ITEM/MATERIAL/ACCESSORY ATTACHED TO THE WALLS/FRAMING/STRUCTURE. <br />8. ALL EXPOSED WOOD BEAMS, DECKING OR OTHER MEMBER INSTALLED PRIOR TO ENCLOSING THE BUILDING ENVELOPE AND <br />COMPLETING ROOFING MEMBRANE SHALL BE PROTECTED DURING CONSTRUCTION AGAINST MOISTURE, STAINING AND OTHER <br />DAMAGE BY PROTECTING WITH WEATHERPROOF PLASTIC WRAPPERS AND ADDITIONAL PROTECTIVE MEASURES AS MAY BE <br />REQUIRED. <br />9. ALL ROOF BEAMS AND SUPPORTING POSTS SHALL BE ANCHORED TO PROVIDE RESISTANCE AGAINST UPLIFT. POSTS SHALL BE <br />ANCHORED TO THE FOOTINGS OR UNDER-FLOOR CONSTRUCTION. ALL ANCHORAGE SHALL BE NOT LESS THAN 1/2" BOLTS OR <br />1/2" LAG SCREWS. <br />10. CONTRACTOR AND FRAMING SUBCONTRACTOR TO USE ALL CONSTRUCTION DOCUMENTS (INCLUDING BUT NOT LIMITED TO <br />ARCHITECTURAL, STRUCTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS) TO FRAME PROJECT. <br />11. ALL HEAD-OUTS ARE THE RESPONSIBILITY OF THE CONTRACTOR INCL DROP CEILINGS FOR MECH DUCTWORK DESIGN-BLD. <br />12. CONTRACTOR SHALL COORDINATE RECESSED LIGHTS AND SUPPLY/RETURN AIR VENTS WITH ROUGH FRAMING. SEE <br />ELECTRICAL AND MECHANICAL DRAWINGS. BRING ALL CONFLICTS TO ARCHITECT'S ATTENTION BEFORE FRAMING IS IN PLACE. <br />13. REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATION OF OPENINGS AND/OR SUPPORTS FOR <br />THEIR RESPECTIVE ITEMS. REFER TO ARCHITECTURAL DRAWINGS FOR SIZES OF ALL OPENINGS. NOTIFY ARCHITECT PRIOR TO <br />CONSTRUCTION OF ANY INTERFERENCE OR INCOMPATIBILITY. <br />14. FRAMING LUMBER SHALL BE DOUGLASS FIR # 2 OR BETTER AND GRADE MARKED A PER WCLB SPECIFICATION UNLESS <br />OTHERWISE SPECIFIED IN DRAWINGS. 15%MAXIMUM MOISTURE CONTENT FOR ANY LUMBER ON SITE <br />15. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 7% FOR ALL MEMBERS FOLLOW 2002 CBC SERIES REQUIREMENTS. <br />CONTRACTOR SHALL ANTICIPATE NORMAL SHRINKAGE OF WOOD FRAMING AND PREVENT DAMAGE TO FINISHES, PLUMBING, ETC. <br />16. PROVIDE WASHERS UNDER HEADS AND NUTS OF BOLTS AND LAG SCREWS BEARING ON WOOD. <br />17. BOLT HOLES TO BE NOMINAL DIAMETER OF BOLTS PLUS 1/16" UNLESS OTHERWISE NOTED. SEE S.E. PLANS. <br />18. SPACE STUDS AT 16" ON CENTER UNLESS OTHERWISE NOTED. STUDS SHALL BE INSTALLED FULL LENGTH WITH NO SPLICES <br />PERMITTED. STUDS SHALL BE CUT ACCURATELY TO LENGTH TO REST ACCURATELY AND TO BEAR ON SILL. SEE FLOOR PLAN <br />NOTES FOR STUD SIZES. <br />19. AT ALL CORNERS PROVIDE NOT LESS THAN 3 STUDS, LOCATED SO AS TO PROVIDE SURFACES FOR ATTACHMENT OF ALL <br />INTERIOR AND EXTERIOR FACINGS. <br />20. FOR FRAMING AROUND DOOR OPENINGS INSTALL TWO STUDS AT EACH JAMB CONTINUOUS FROM FLOOR TO STRUCTURE. <br />TIE STUDS ADJACENT TO FRAMES SECURELY TO JAMB ANCHORS IN FRAMES. STIFFEN JACK STUDS OVER OPENINGS WITH <br />BRIDGING LOCATED APPROXIMATELY 6" ABOVE FRAME AND EXTENDING APPROXIMATELY 36" BEYOND JAMB ON EACH SIDE. <br />21. BRIDGING SHALL BE PLACED IN STUD WEB OPENINGS AND SECURELY TIED IN PLACE. <br />22. WOOD MEMBERS IN CONTACT WITH CONCRETE/MASONRY SHALL BE PRESSURE TREATED LUMBER. <br />23. ALL NAILS SHALL BE COMMON, UNLESS NOTED OTHERWISE, USING GALVANIZED AT EXTERIOR LOCATIONS. <br />24. ALL PLYWOOD SHALL BE MANUFACTURED UNDER PROVISIONS OF A.P.A. PRP-108, AND U.S. PRODUCT STANDARD PS I-83. ALL <br />PLYWOOD SHALL BE GROUP NO. 1 UNLESS NOTED OTHERWISE. SEE STRUCTURAL SPECS. FOR PLYWOOD. <br />25. PROVIDE 1X6 DIAGONAL LET-IN BRACES AT EACH WALL AND AT 20' MAX INTERVALS WITH 2-8D NAILS PER STUD. NOT <br />REQUIRED WHERE PLYWOOD SHEATHING IS USED. <br />26. ROUGH FRAMING HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. <br />27. STUDDING: MINIMUM STUD WALL SIZE 2"X6" @ 16" O/C UNLESS OTHERWISE NOTED. SEE FLOOR PLANS FOR SIZES <br />28. FIRESTOPPING: FIREBLOCK WALLS AND FUR WALLS SO THAT NO SPACE EXCEEDS 10' IN HEIGHT OR LENGTH BOTH <br />VERTICALLY AND HORIZONTALLY. FIREBLOCK AT DOOR POCKETS. PROVIDE FIREBLOCKS AT DROPPED CEILINGS, SOFFITS, AND <br />CEILING COVES/COFFERS. PROVIDE FIRE BLOCKS BETWEEN STAIR STRINGERS AT TOP AND BOTTOM OF STAIR FLIGHT. PROVIDE <br />CONTINUOUS FIREBLOCKS AT STAGGERED STUD WALLS. PROVIDE APPROVED FIRESTOPPING AROUND PENETRATIONS AT FIRE <br />BLOCKS FOR PIPES, VENTS, DUCTS, FIREPLACES, FLUES, ETC.. PROVIDE FIRE BLOCK AT ATTIC SPACES AND CHIMNEY CHASES <br />FOR PREFABRICATED CHIMNEYS. <br />29. FIREBLOCK SHALL BE CONTINUOUS AT STAGGERED STUD WALLS. SEE STRUCTURAL PLANS & 2022 CBC & 2022 CFC <br />30. DRAFT STOPS: PROVIDE DRAFT STOPS BELOW AND ABOVE ALL FLOOR-CEILING ASSEMBLIES AT EACH 1,000 S.F. MAX., <br />EQUALLY DIVIDED OR PER LOCAL CODE. <br />31. ALL WOOD TOP PLATES SHALL BE DOUBLED AND LAP SPLICED AT 4'-0" MIN. UNLESS NOTED OTHERWISE. REFER TO <br />STRUCTURAL PLAMS. <br />32. ALL CARPENTRY SHALL PRODUCE JOINTS TRUE, TIGHT AND WELL NAILED PER S.E.. ON ALL FRAMING MEMBERS TO RECEIVE <br />A FINISH, ALIGN FRAMING TO VARY NOT MORE THAN 1/8" IN EACH 8'-0". SHIMMING IS NOT ACCEPTABLE. <br />33. ALL WALLS SHALL BE BOLTED TO FOUNDATION AS PER STRUCTURAL DRAWINGS AND SPECIFICATIONS AND PER CODE. <br />MINIMUM SILL PLATE 3"X4" (PRESSURE TREATED IF IN CONTACT WITH CONCRETE). <br />34. FLOOR JOISTS SHALL BE DOUBLED UNDER PARTITIONS RUNNING PARALLEL TO THE JOISTS. PROVIDE SOLID BLOCKING <br />UNDER ALL PERPENDICULAR PARTITIONS. <br />35. HOLES BORED IN FRAMING MEMBERS SHALL BE APPROVED BY STRUCTURAL ENGINEER IN WRITTING BY CONTRACTOR. <br />36. WHERE PLYWOOD SHEATHING IS SPECIFIED, PROVIDE 1/8" GAP BETWEEN PANEL EDGES. VERIFY WITH STRUCTURAL <br />ENGINEER. FRAMING MEMBERS WITH WANE SHALL NOT BE USED IN SHEAR WALL FRAMING, OR SUPPORTING PLYWOOD, GYPSUM <br />BOARD, OR ARCHITECTURAL SPECIALTIES/FINISHES. ON OTHER WALLS WANE SHALL NOT EXCEED 5% ON AGGREGATE OF <br />FRAMING MEMBERS IN A WALL OR CEILING.OF BEARING THROUGH TO FOUNDATION. <br />38. GLUE-LAM TIMBER - REFER TO STRUCTURAL ENGINEER PLANS AND TRUSS ENGINEERING COMPANY <br />ROOF, ROOF FLASHING & DRAINAGE <br />1. ALL ROOFS TO BE MIN. CLASS A, 15 YEAR BONDABLE, MEETING CODE REQUIREMENTS. PROVIDE THE OWNER WITH CUT SHEET <br />& SPECIFICATIONS FOR ROOFING SEE DRAWINGS. <br />ENERGY/ INSULATION; CALIFORNIA STATE DESIGN STANDARDS <br />1. ALL NEW AND EXISTING EXTERIOR WALL THAT ARE OPENED DURING THE COURSE OF CONSTRUCTION SHALL BE INSULATED <br />WITH BLANKET TYPE MINERAL OR GLASS FIBER INSULATION CONFORMING TO 2022 CBC & 2022 CMC REFER TO T-24 FOR <br />REQUIREMENTS. <br />2. INSULATION THICKNESS AND THERMAL RESISTANCE SHALL CONFORM TO TITLE 24 REGULATIONS FOR CLIMATE ZONE OF JOB <br />SITE. CONFIRM INSULATION TYPE AND THICKNESS WITH OWNER AND ARCHITECT PRIOR TO FINALIZING GENERAL <br />CONSTRUCTION CONTRACT. <br />DOOR, WINDOWS <br />1. ALL DOORS AND WINDOWS DESIGN AND MANUFACTURER TO BE APPROVED BY CLIENT. INSTALL, TEST AND WATERPROOF PER <br />MANUFACTURER RECOMMENDATIONS. <br />2. PRIOR TO INSTALLATION, ALL PAINTED WOOD DOOR AND WINDOW FRAMES SHALL BE PRIMED WITH AN APPROVED PRIMER <br />COMPATIBLE WITH FINISH PAINT SPECIFICATIONS, INCLUDING BACK SIDES OF FRAMES, FRAME BUCKS AND END GRAIN CUTS. <br />STAINED WOOD FRAMES SHALL BE BACK-PRIMED SO AS NOT TO SHOW IN FINISH. <br />3. GLASS DOORS, ADJACENT GLASS PANELS WITHIN 24" OF DOORS, AND ALL GLAZED OPENINGS WITHIN 18" OF THE ADJACENT <br />FLOOR OR LANDING SHALL BE OF GLASS APPROVED FOR IMPACT HAZARD. <br />SECURITY NOTES <br />PROVIDE CLIENT & ARCHITECT WITH SHOP DRAWINGS FOR REVIEW. ALL OPERABLE WINDOWS SHALL BE PROVIDED WITH <br />SUBSTANTIAL LOCKING DEVICES. <br />FINISHES, CABINETRY, RAILING, ETC. <br />1. WELDING AT GUARDRAILS (IF REQUIRED) SHALL BE DONE BY WELDERS CERTIFIED BY THE LOCAL BUILDING DEPARTMENT. <br />2 EXTERIOR AND INTERIOR WALL INSULATION SHALL BE INCOMBUSTIBLE. CONTRACTOR SHALL PROVIDE ACCESS PANELS AS <br />REQUIRED BY THE PLUMBING, HVAC, AND OTHER INSTALLATIONS, AND AS REQUIRED BY 2022 CBC CODE. <br />3 PROVIDE SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT AS REQUIRED BY 2022 CBC CODE <br />DRYWALL/INTERIOR PLASTER: <br />UNLESS NOTED OTHERWISE, ALL PLASTER AND DRYWALL MATERIALS AND INSTALLATION SHALL BE TYPE "X" & ACCORDING TO <br />CURRENT U.S. GYPSUM HANDBOOK SPECIFICATIONS AND APPLICABLE CODE REQUIREMENTS. USE WATERPROOF DRYWALL IN <br />ALL BATHROOMS, KITCHENS, JANITOR'S CLOSETS AND WET AREAS. <br />CERAMIC TILE/ STONE: <br />ALL CERAMIC, MARBLE, GRANITE, SLATE OR OTHER TILE W ORK SHALL BE ACCORDING TO CURRENT STANDARDS AND <br />SPECIFICATIONS OF THE TILE COUNCIL OF AMERICA AND CERAMIC TILE INSTITUTE. COORDINATE WITH INTERIOR DESIGNER. <br />PAINTING: <br />1. CONTRACTOR SHALL INCLUDE WITHIN THE SCOPE OF HIS WORK PREPARATION , PRIMING AND FINISHING PAINTING OF <br />EXTERIOR WALLS AFFECTED BY ADDITIONS AND REMODELING AND INTERIOR WALLS AND CEILINGS, INCLUDING DOORS, SASH <br />AND TRIM WORK. CONFIRM ANY EXPOSED BEAMS, DECKING, CABINETS OR WOOD TO BE STAINED AND/OR CLEAR-SEALED PRIOR <br />TO ORDERING. SEE EXTERIOR ELEVATIONS FOR COLORS. COORDINATE WITH INTERIOR DESIGNER FOR ALL INTERIOR FINISHES & <br />PAINTING. <br />UTILITIES, PLUMBING, DRAINAGE, ETC.: <br />1. GENERAL CONTRACTOR SHALL CONFIRM ARRANGEMENTS FOR ANY TEMPORARY POWER AND TELEPHONE SERVICE WITH <br />OWNER. <br />2. EXCEPT AS PROVIDED BY ARCHITECT IN THE CONSTRUCTION DOCUMENTS, CONTRACTOR SHALL DESIGN, PREPARE <br />NECESSARY PLANS, HAVE PLANS CHECKED AND OBTAIN BUILDING PERMITS FOR ALL PLUMBING SYSTEMS AND EQUIPMENT. <br />3. CONTRACTOR SHALL REROUTE ANY EXISTING UTILITY LINES, CONDUITS OR EQUIPMENT IN CONFLICT WITH NEW <br />CONSTRUCTION. COORDINATE WITH CLIENT. <br />MECHANICAL, SHEET METAL: <br />1. ALL SHEET METAL WORK SHALL BE IN ACCORDANCE WITH LOCAL STANDARDS, 2022 CMC AND LOCAL BUILDING CODES. <br />2. CONTRACTOR SHALL PROVIDE AIR CONDITIONING, GAS-FIRED FURNACES AND/OR FORCED AIR HEATING SYSTEM AS INDICATED <br />ON PLANS. EQUIPMENT, DUCTS, AND REGISTERS SHALL BE SIZED AND INSTALLED TO PROVIDE ADEQUATE AIR TEMPERATURE, <br />VOLUME, DISTRIBUTION AND CIRCULATION AT MINIMUM NOISE LEVELS. SYSTEM EQUIPMENT AND LAYOUT SHALL BE CONFIRMED <br />WITH OWNER. FOLLOW ALL 2022 CMC & 2022 CPC & 2022 CEC <br />3. EXCEPT AS PROVIDED BY ARCHITECT OR MEP CONSULTANT IN THE CONSTRUCTION DOCUMENTS, CONTRACTOR SHALL <br />DESIGN, PREPARE NECESSARY PLANS, PROVIDE SIZING OF ALL HVAC EQUIPMENT AND CALCULATIONS, HAVE PLANS CHECKED <br />AND OBTAIN BUILDING PERMITS FOR THE HVAC SYSTEM. <br />ELECTRICAL NOTES: <br />SEE T-24 ENERGY SECTION FOR ADDITIONAL INFORMATION REGARDING THERMOSTATS, INSULATION, ETC. <br />1. CONTRACTOR SHALL OBTAIN A SIGNED PLAN FROM THE POWER COMPANY WHICH APPROVES SIZES, LOCATIONS, AND <br />SPECIFIC CLEARANCES OF MAIN SERVICE AND PANEL, ANY TRANSFORMERS, U.G. LINES, NEW POLES, OVERHEAD LINES, AND ANY <br />OTHER RELATED ELECTRICAL INFORMATION OVER WHICH THE POWER COMPANY HAS AUTHORITY. <br />2. EXCEPT AS PROVIDED BY ARCHITECT IN THE CONSTRUCTION DOCUMENTS, CONTRACTOR SHALL DESIGN, PREPARE <br />NECESSARY PLANS, SCHEDULES, AND CALCULATIONS, HAVE PLANS CHECKED AND OBTAIN BUILDING PERMITS FOR ALL <br />ELECTRICAL SYSTEMS AND EQUIPMENT. <br />ENERGY/INSULATION NOTES: <br />ALL OPENINGS SHALL COMPLY WITH STATE CODE TITLE 24 ENERGY STANDARDS. <br />FIXED WINDOWS SHALL BE SEALED TO LIMIT AIR LEAKAGE. ALL EXTERIOR DOORS AND WINDOWS SHALL LIMIT AIR LEAKAGE <br />AROUND PERIMETER WHEN IN A CLOSED POSITION. INSULATION IN ALL NEW WALLS TO BE PER T24, IN NEW ROOFS TO BE R30 <br />BATT INSULATION, AND R19 BATT INSULATION IN NEW FLOORS. <br />SOUND CONTROL: PROVIDE MAT SPECS FOR ARCH & CLIENT REVIEW. <br />1. FILL JOIST/STUD SPACE WITH MINERAL FIBER INSULATION OF A MINIMUM R VALUE OF 13. <br />GENERAL CODE ENFORCEMENT NOTES <br />1. STRUCTURAL OBSERVATION SHALL BE REQUIRED BY THE STRUCTURAL ENGINEER OF RECORD FOR STRUCTURAL <br />CONFORMANCE TO THE APPROVED PLANS. A SPECIAL INSPECTION IS REQUIRED FOR THE TYPES OF WORK SPECIFIED BELOW. <br />REFER TO STRUCTURAL ENGINEER PLANS FOR ADDITIONAL ITEMS. <br />-CONCRETE, WELDING, H.S. BOLT, PILING, DRILLED PIERS, AND CAISSONS, REINFORCED STEEL + WWF <br />-PLYWOOD DIAFRAMS INCLUDING CHORDS, COLLECTORS, HOLDOWNS <br />TERMITE PROTECTION: FOLOR ALL LOCAL BUILDING STANDARDS INL 2022 CBC SERIES. <br />IN GEOGRAPHICAL AREAS WHERE HAZARD OF TERMITE DAMAGE IS KNOWN TO BE VERY HEAVY, WOOD FLOOR FRAMING SHALL <br />BE OF NATURALLY DURABLE SPECIES (TERMITE RESISTANT) OR PRESERVATIVE TREATED IN ACCORDANCE WITH AWPA U1 FOR <br />THE SPECIES, PRODUCT PRESERVATIVE AND END USE OR PROVIDED WITH APPROVED METHODS OF TERMITE PROTECTION. <br />SITE PROTECTION: CONTRACTOR TO PROVIDE PROTECTION TARP OVER RESIDENCE WHEN THERE IS ANY CHANCE OF RAIN, TO <br />PROTECT SURFACES. NEW FLOORS TO BE COVERED AND PROTECTED DURING CONSTRUCTION. <br />CONTRACTOR IS RESPONSIBLE FOR REPLACING DAMAGED EXISTING ITEMS OR SURFACES AT NO ADDITIONAL COST TO OWNER. <br />FOOTINGS & BASEMENTS: CONTRACTOR IS TO VERIFY EXISTENCE OF HIGH LEVELS OF SULFUR OR ALKALINITY IN SOIL. IF SUCH <br />CONDITIONS EXIST, USE TYPE V CONCRETE IN ALL APPLICATIONS WHERE CONCRETE IS ON TOP OF , NEXT TO, OR SURROUNDED <br />BY SOIL. <br />ALL FOOTINGS, STEM-WALLS, AND RETAINING WALLS TO RECEIVE WATERPROOFING. FOOTINGS AND RETAINING WALL TO BE <br />WATERPROOFING WITH ROLL-ON BITUTHENE. STEM WALLS TO BE WATERPROOFED WITH PROCOR TO TOP OF STEM WALL. <br />BASEMENT WALL TO BE WATERPROOFED WITH BITHUENE W.R. GRACE 3000 WITH HYDRO DUCT 2 OR APPROVED EQUAL. <br />FOOTINGS AT BASEMENTS TO BE COMPLETELY WATERPROOFED INCLUDING UNDER-FOOTING AREA. <br />CONCRETE SHALL BE FINISHED IN A MANNER SUITABLE TO RECEIVE WATERPROOFING; STRICTLY FOLLOW RECOMMENDATIONS <br />OF MEMBRANE MANUFACTURER FOR SURFACE PREPARATION AND USE OF PRODUCTS. <br />FOR PROJECTS WITH A SUBMERGED BASEMENT, NEAR OCEAN CONDITIONS, OR UNDER A LAGGING SITUATION, TREMCO <br />PARASEAL SW IS TO BE USED, CONSISTING OF A LAYER OF SOCCOSHIELD/EPRO SHIELD AND TWO LAYERS OF PARASEAL SALT <br />WATER MEMBRANES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR SHALL COORDINATE WITH <br />WATERPROOFING CONSULTANT, SUBMIT SHOP DRAWINGS & SUBMITTALS TO ARCHITECT. <br />CONCRETE UNDER SLAB WATERPROOFING <br />REFER TO STRUCTURAL ENGINEER, SOILS REPORT PLANS FOR WATERPROOFING. CONTRACTOR SHALL COORDINATE WITH <br />WATERPROOFING CONSULTANT, SUBMIT SHOP DRAWINGS & SUBMITTALS TO ARCHITECT. <br />SHEET METAL: IF CONTRACTOR PLANS TO SUBSTITUTE NOTIFY ARCHITECT. FOLLOW ALL 2022 CBC SERIES & LOCAL STANDARDS. <br />PROVIDE MAT SPECS, SHOP DRAWINGS & INSTALLATION INSTRUCTIONS FOR ARCH & CLIENT REVIEW. <br />SHEET METAL/FLASHING SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING ITEMS: <br />WINDOW/DOOR SILL PANS WITH HEMMED EDGES AT ALL EXT. WINDOWS/DOOR - SOLDER ALL CORNERS/INTERSECTIONS. <br />WINDOW/DOOR HEAD 16 OZ. ETCHED COPPER FLASHING WITH 8" RETURNS AT SIDES. DOOR PANS 16 OZ. LEAD COATED COPPER <br />CORNER, FULLY SOLDERED WITH 8" RETURNS. <br />DRIP SCREED 20 OZ. LEAD COATED COPPER, HEMMED EDGE. <br />ROOF FLASHING 20 OZ. COPPER. <br />COPPER STEP FLASHING WHERE APPLICABLE. <br />VALLEY FLASHING 20 OZ. COPPER. <br />Z BAR 20 OZ. COPPER, 3" MIN. NAILING FLANGE. <br />FAN VENT BATH 20 OZ. COPPER. <br />ROOF EDGE 20 OZ. COPPER, HEMMED EDGE, WITH CONTINUOUS CLEAT (IF APPLICABLE). <br />ROOF TRANSITION 20 OZ. COPPER. EXTEND 12" MIN. ON EACH ROOF. <br />GUTTERS/DOWNSPOUTS 20 OZ. COPPER GUTTER 5" HALF ROUND WITH 3" 16 OZ. COPPER DOWNSPOUT. FINISH TO DUPLICATE <br />BLACKENED COPPER. <br />MANUFACTURER'S RECOMMENDATIONS AND BUILDINGS CODE. <br />FIREPLACE SADDLES 20 OZ. COPPER. <br />WEEP SCREED VINYL, 3" MINIMUM NAILING FLANGE. <br />CHIMNEY CAP 16 OZ. COPPER <br />ROOF DRAIN FLASHING 30" SQUARE MIN. 4 LB. LEAD SET IN ROOF CEMENT. PRIME TOP SURFACE BEFORE STRIPPING. <br />ROOF VENTS ½ ROUNDS, 16 OZ. COPPER EXPANSION JOINT 16 OZ. COPPER. INTERLOCKING SLIDING FLASHING. <br />UNDERFLOOR ACCESS DOOR 20 OZ. COPPER WITH 6" FLANGE PAINTED TO MATCH STUCCO PLASTER CONTROL JOINT BY "KEENE <br />CO." PLASTER EXP. JOINT BY BY "KEENE CO.", ¼" WIDE. <br />DRYWALL EDGE TRIM SET058-000 BY SUPERIOR METAL TRIM. <br />PLASTER CONTROL JOINT BY KEENE CO.1. <br />PLASTER CASING BEAD BY "KEENE CO.", ¼" WIDE. <br />SOFT METAL FLASHING CONFORMING TO NRCA RECOMMENDATIONS. <br />DISSIMILAR MATERIAL SHALL NOT BE PUT IN CONTACT. <br />INSTALL ONE LAYER OF BUILDING PAPER BETWEEN SHEET METAL AND SUBSTRATE. <br />SILL PANS: TO BE METAL AS SPECIFIED, WITH SOLDERED CORNERS, AND INSTALLED OVER VYCOR ICE AND WATER SHIELD. TO BE <br />USED AT ALL WINDOW AND DOORSILLS UNLESS NOTED OTHERWISE. <br />NO PENETRATIONS AT HORIZONTAL SURFACE OF PAN, MINIMIZE ANY PENETRATIONS REQUIRED THROUGH VERTICAL SURFACE OF <br />PAN, AND APPLY SEALANT. <br />SILL PAN SHIM: TO BE CONTINUOUS ABOVE ROUGH SILL TO PROVIDE A SOLID SUBSTRATE FOR SILL PAN TO SLOPE TO EXTERIOR. <br />DRIP HEAD FLASHING: PROVIDE DRIP HEAD FLASHING AT ALL WINDOW HEADS. <br />VYCOR ICE AND WATER SHIELD: MANUFACTURED BY W.R. GRACE CO. OTHER PRODUCTS BY GRACE OR OTHERS WILL NOT BE <br />ACCEPTED AS SUBSTITUTES UNLESS NOTED OTHERWISE. <br />VYCOR INSTALLATION: FOLLOW ALL MANUFACTURERS' RECOMMENDATIONS, INCLUDING USE OF PROPRIETARY PRIMER. <br />LAPPING OF VYCOR, SILL PANS, BUILDING PAPER, ETC. UPPER SURFACE IS TO LAP OVER LOWER SURFACE TO PROMOTE DRAINAGE <br />ON OUTERMOST LAYER OF PROTECTIVE MEMBRANES/FLASHING. <br />WEATHERSTRIPPING: ALL WINDOWS AND DOORS ARE TO HAVE FULL WEATHERSTRIPPING. <br />GENERAL: CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT ALL FLASHING PAPER, VYCOR, AND OTHER PRODUCTS ARE <br />PROPERLY INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND BUILDINGS CODE INCL. TESTINGS FOR WATER. PROVIDE <br />MAT SPECS FOR ARCH & CLIENT REVIEW. <br />GRACE FLASHING ICBO#3997. GRACE "ICE AND WATER SHIELD" BY W.R. GRACE CO. ALL INSET OPENINGS TO BE WRAPPED AT HEAD, <br />JAMB+SILL - CREATE SILL PAN. PROVIDE 2 LAYERS OF MATERIAL AT CUTS, LAP SIDE FLASHING OVER SILLS FLASHING UNDER ALL <br />EXTERIOR STONE VENEER W/ 3" OVERLAP @ CEMENT PLASTER SYSTEM. PROVIDE MAT SPECS FOR ARCH & CLIENT REVIEW. <br />SHOWER WATERPROOFING MATERIAL: PER CONTRACTOR. PROVIDE WARRANTY TO CLIENT PROVIDE MAT SPECS FOR ARCH & <br />CLIENT REVIEW. <br />GUTTERS AND DOWN SPOUTS. 6" HALF-ROUND SINGLE BEAD GUTTER - G.I W/ S.S. SUPPORTS @ 36 O.C. 3" DIAMETER <br />DOWNSPOUT - G.I. GUTTERS TO BE APPROVED BY CLIENT & ARCH AS ALTERNATE PROVIDE MAT SPECS FOR ARCH & CLIENT <br />REVIEW. <br />EXTERIOR PLASTER. MATERIAL INTEGRAL COLOR, SMOOTH STEEL-TROWEL STUCCO FINISH. SMOOTH FINISH CEMENT PLASTER <br />SYSTEM PER EXTERIOR ELEVATIONS: 3 COAT, 7/8" MIN. CEMENT PLASTER OVER EXPANDED METAL LATH. SEE EXTERIOR <br />ELEVATIONS SHEETS FOR FINISH. VERIFY ALL COLORS AND WITH CLIENT. PROVIDE WARRANTY TO CLIENT. PROVIDE MAT SPECS <br />FOR ARCH & CLIENT REVIEW. <br />GYP. BOARD. STANDARD SMOOTH 5/8" TYPE "X" FIRE RATED GYP. BD. SCREW ATTACHMENTS GYPSUM WALL BOARD SYSTEM SHALL <br />CONFORM TO THE APPROVED LOCAL BUILDING CODE. FINISH SHALL BE AS DEFINED BY THE GYPSUM ASSOCIATION. <br />INSTALL GYPSUM BOARD OVER RESILIENT CHANNELS AT ALL CEILINGS WITH LIVING SPACE ABOVE. <br />CORNER BEAD: SHARP 90 DEGREES CORNERS THROUGHOUT. W/ ROLLED EDGE TO RESEMBLE A PLASTER CORNER. <br />EXTERIOR PAINTING. PRIME ALL SIDES OF FINISH WOOD. PRIME ENDS OF ALL CUT MATERIALS. COORDINATE WITH CLIENT ALL <br />PAINTING. PROVIDE WARRANTY TO CLIENT PROVIDE MAT SPECS FOR ARCH & CLIENT REVIEW. <br />CONCRETE EXTERIOR: <br />MOISTURE BARRIER: EXTERIOR SLABS SHALL BE POURED OVER ONE 2"-LAYER OF COMPACTED SAND, OVER 10 MIL. VISQUEEN, <br />OVER ONE 2"-LAYER OF COMPACTED SAND. SEE STRUCTURAL FOR CONCRETE SLAB SPECIFICATIONS. PROVIDE MAT SPECS FOR <br />ARCH & CLIENT REVIEW. <br />CONCRETE BLOCK: SEE STRUCTURAL FOR CONCRETE SLAB SPECIFICATIONS. <br />RAILINGS AND HANDRAILS: <br />RAILINGS MUST BE INSTALLED AND WATERPROOFED PRIOR TO STUCCO SCRATCH COAT OR OTHER WALL COVERINGS SUCH AS <br />WOOD SIDING, . SEE RAIL SPECIFICATIONS ON DRAWINGS FOR DETAILS. SUBMIT SPECS / CUT SHEETS TO ARCHITECT. <br />PLYWOOD: ALL PLYWOOD SHALL BE PER STRUCTURAL DRAWINGS & SPECS. <br />CABINETRY: CONTRACTOR SHALL COORDINATE WITH CLIENT & INTERIOR DESIGNER FOR ALL CABINETRY. PROVIDE MAT SPECS <br />INCLUDING INTERIOR DRAWINGS, SPECS AND COLOR SAMPLES FOR ARCH & CLIENT REVIEW. <br />ROOF UNDERLAYMENT: CONTRACTOR SHALL SET UP A MEETING ON-SITE FOR ROOFING SUB-CONSULTANT & WATERPROOFING <br />CONTRACTOR INCL MANUFACTURER TO VERIFY ALL EXISTING ON-SITE ROOF CONDITIONS; ROOF CANTS, METAL FLASHINGS AND <br />WATERPROOFING CONDITIONS. NOTIFY ARCHITECT & CLIENT OF MEETING. PROVIDE MAT SPECS FOR ARCH & CLIENT REVIEW. <br />GENERAL ROOFING SPECS (PENDING MEETING & DETERMINATION ON-SITE): INSTALLATION SHALL COMPLY WITH CODE <br />REQUIREMENTS, AND WITH ALL STANDARDS, RECOMMENDATIONS AND REQUIREMENTS OF N.R.C.A. ALL ROOFING INSTALLATIONS <br />SHALL INCLUDE UNDERLAYMENT. ROLL MEMBRANE DOWN AT VERTICAL SURFACES AT EDGES OF ROOF A MIN. OF 3" <br />CONTRACTOR SHALL SET UP A MEETING ON-SITE FOR DECKS/BALCONIES SUB-CONSULTANT & WATERPROOFING CONTRACTOR <br />TO VERIFY EXISTING ON-SITE DECKS, SLABS AND PLANTERS CONDITIONS; METAL FLASHINGS AND WATERPROOFING <br />CONDITIONS. NOTIFY ARCHITECT & CLIENT OF MEETING. PROVIDE MAT SPECS FOR ARCH & CLIENT REVIEW. <br />GENERAL DECK SPECS (PENDING MEETING & DETERMINATION ON-SITE): PROVIDE MAT SPECS FOR ARCH & CLIENT REVIEW. <br />DECK WATERPROOFING: DEX-O-TEX ENDURO-KOTE AND ENDURO-FLEX KOTE DECK & ROOF COVERING SYSTEM RESEARCH <br />REPORT RR 24842 - OR - ELASTO-DECK B.T. BY PACIFIC POYMERS (714)-898-0025 PROVIDE MANUFACTURER RECOMMENDED <br />PENETRATION FLASHING AND VENTING. PROVIDE L METAL FLASHING AT PERIMETER AND WALL/VERTICAL SURFACE TRANSITION. <br />EXTERIOR FINISH UNDERLAYMENT: PROVIDE ARCHITECT WITH SPECS AND MANUAL FOR WATERPROOFING FOR REVIEW <br />CONTRACTOR SHALL FOLLOW ALL LOCAL BUILDING CODES & ALL LOCAL STANDARDS INCLUDING THE 2022 CBC "SERIES". <br />IF THERE IS A DISCREPANCY BETWEEN GENERAL NOTES / PLANS / INFORMATION AS SHOWN ON PLANS AND THE LOCAL <br />BUILDING CODES & STANDARDS INCL. 2022 CBC, THE MOST STRINGENT (LOCAL BUILDING CODES & STANDARDS AND 2022 <br />CBC REGULATIONS) SHALL APPLY. THE CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES, ALL <br />CONSTRUCTION SHALL FOLLOW INSPECTIONS AS REGULATED BY THE LOCAL GOVERNING INSPECTIONS AND <br />REGULATIONS. <br />"CONTRACTOR SHALL HIRE, COORDINATE AND CONSULT WITH ROOFING & FLASHING SUB/MANUFACTURER, DOOR & <br />WINDOW MANUF, WATER PROOFING CONSULTANT & SHALL PROVIDE BUILDING ENVELOPE BUILDING PAPER ON ALL <br />INSTALLATIONS. NOTE: WATERPROOFING TECHNIQUES & SYSTEMS TO BE INSTALLED SHALL BE PER WATERPROOFING <br />CONSULTANT & MATERIAL MANUFACTURER SPECIFICATIONS. CONTRACTOR SHALL SET ON-SITE MEETINGS WITH "THE <br />CONTRACTOR SUBS/MANUFACTURERS INCLUDING CLIENT & ARCHITECT" TO GO OVER THE INSTALLATIONS AND <br />PROCEDURES AS SPECIFIED BY MANUFACTURERS OF ALL SYSTEMS TO BE USED IN CONSTRUCTION. CONTRACTOR SHALL <br />PROVIDE WARRANTY TO CLIENT OF SYSTEMS. SUBMIT ALL SHOP DRAWINGS AND MAT SPECS FOR CLIENT & ARCH REVIEW. <br />NO EXCEPTIONS. IF CONTRACTOR REQUESTS SUBSTITUTIONS THEY MUST BE SUBMITTED TO CLIENT & ARCHITECT REVIEW <br />& APPROVAL IN WRITTING PRIOR TO ORDERING AND INSTALLATION." IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY <br />FOR ACCURACY OF SHOP DRAWINGS. <br />NOTE: SUBMITTALS REVIEWED BY ARCHITECT ARE ONLY GENERAL & FOR CONFORMITY WITH DESIGN CONCEPT OF THE <br />PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. CORRECTIONS <br />AND/OR COMMENTS MADE AS PART OF THIS SUBMITTAL REVIEW DO NOT RELIEVE CONTRACTOR OF RESPONSIBILITY FROM <br />CONFORMANCE WITH THE CONTRACT DOCUMENTS, APPLICABLE CODES, AND LAWS - ALL OF WHICH HAVE PRIORITY OVER <br />THIS SUBMITTAL. THE DESIGN PROFESSIONAL DOES NOT WARRANT OR REPRESENT THAT THE INFORMATION WITHIN THE <br />SUBMITTAL IS EITHER ACCURATE OR COMPLETE. SOLE RESPONSIBILITY FOR CORRECT DESIGN, DETAILS, AND <br />DIMENSIONS SHALL REMAIN WITH THE PARTY PROVIDING THE SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR ALL <br />DIMENSIONS, QUANTITIES, AND PERFORMANCE REQUIREMENTS TO BE CONFIRMED AND CORRELATED AT THE JOB SITE; <br />FOR ALL INFORMATION THAT PERTAINS SOLELY TO THE FABRICATION PROCESSES OR TO TECHNIQUES OF <br />CONSTRUCTION; FOR ALL COORDINATION OF THE WORK OF ALL TRADES; FOR ASSURING CONSISTENCY WITH THE <br />CONTRACT DOCUMENTS; AND FOR PERFORMING THE WORK IN A SAFE AND SATISFACTORY MANNER. <br />CONTRACTOR SHALL COORDINATE WITH CLIENT'S OWNERS REPRESENTATIVE ALL OTHER KITCHEN OR RESTAURANT <br />EQUIPMENTS INCLUDING OTHER SPEACIAL CONSULTANTS & SUBS AS NEEDED TO COMPLETE THE CLIENTS "WORK" <br />SUBMIT ALL SHOP DRAWINGS AND SPECIFICATIONS FOR ARCHITECT INCLUDING OTHER DESIGN PROFESSIONALS & CLIENT <br />REVIEW. <br />NOTE: THE ABOVE INFORMATION "SPECS AND GENERAL NOTES" ARE PROVIDED AS A GUIDE FOR CONTRACTOR'S REVIEW <br />& INFORMATION. CONTRACTOR SHALL NOTIFY THE CLIENT & CLIENT'S REPRESENTATIVE INCLUDING THE ARCHITECT IF <br />ANY OF THE ABOVE INFORMATION OR INFORMATION IN THE SET OF CONSTRUCTION DOCUMENTS / PLANS CONTAINS ANY <br />INACURACIES OR IF ANY INFORMATION DOES NOT APPLY TO THE PROJECT. <br />No. Description Date <br />1430 E Edinger Ave <br />3/27/2025