400 Sunrise Ave., Suite 270
<br />Roseville, CA 95661
<br />916.755.3571 / MiTek-US.com
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org)
<br />BCSI Building Component Safety Information
<br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
<br />and available from the Structural Building Component Association (www.sbcscomponents.com)
<br />0.2512
<br />0.25
<br />12
<br />=3x4
<br />=5x6
<br />=3x10
<br />=4x12
<br />=3x4
<br />=3x4
<br />=3x4
<br />=6x16
<br />=4x5
<br />=6x8
<br />11
<br />10
<br />17
<br />18
<br />9
<br />19 8 20
<br />7
<br />12
<br />13
<br />1 2 14 3
<br />4 15 5 16 6
<br />0-5-8
<br />-0-5-8
<br />3-0-8
<br />3-0-8
<br />6-1-7
<br />9-2-0
<br />6-5-0
<br />15-7-0
<br />0-3-12
<br />0-3-12
<br />0-1-0
<br />3-4-4
<br />0-7-8
<br />15-7-0
<br />2-11-8
<br />3-3-4
<br />5-9-8
<br />14-11-8
<br />5-9-11
<br />9-2-0
<br />2-10
<br />-0
<br />1-2-2
<br />2-0-12
<br />0-3-9
<br />1-7-2
<br />0-9-4
<br />1-2-14
<br />1-2-14
<br />1-7-2
<br />2-10
<br />-0
<br />Scale = 1:36.9
<br />Plate Offsets (X, Y):[6:0-5-4,0-3-4], [7:Edge,0-3-9]
<br />Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
<br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.65 Vert(LL)-0.13 7-8 >999 360 MT20 220/195
<br />TCDL 14.0 Lumber DOL 1.25 BC 0.59 Vert(CT)-0.19 7-8 >765 240
<br />BCLL 0.0 *Rep Stress Incr NO WB 0.55 Horz(CT)0.01 13 n/a n/a
<br />BCDL 7.0 Code IBC2021/TPI2014 Matrix-MSH Wind(LL)0.01 8 >999 240 Weight: 81 lb FT = 20%
<br />LUMBER
<br />TOP CHORD 2x4 DF No.2 G
<br />BOT CHORD 2x4 DF No.2 G
<br />WEBS 2x4 DF No.2 G or 2x4 DF Std G or 2x4 DF
<br />Stud G *Except* 9-4:2x8 DF No.2 G
<br />OTHERS 2x8 DF No.2 G
<br />BRACING
<br />TOP CHORD Structural wood sheathing directly applied or
<br />6-0-0 oc purlins, except end verticals, and
<br />2-0-0 oc purlins (6-0-0 max.): 3-9, 4-6.
<br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
<br />bracing, Except:
<br />6-0-0 oc bracing: 9-10.
<br />REACTIONS (size)1=0-5-8, 9=0-5-8, 13=0-5-8
<br />Max Horiz 1=-52 (LC 10)
<br />Max Uplift 1=-13 (LC 40), 9=-30 (LC 8),
<br />13=-21 (LC 9)
<br />Max Grav 1=433 (LC 29), 9=760 (LC 44),
<br />13=583 (LC 46)
<br />FORCES (lb) - Maximum Compression/Maximum
<br />Tension
<br />TOP CHORD 2-10=0/438, 1-2=-75/68, 2-3=-80/282,
<br />3-9=-503/163, 3-4=-266/99, 4-5=-67/80,
<br />5-6=-747/240, 7-12=0/420, 6-12=0/420
<br />BOT CHORD 10-11=0/0, 9-10=-38/198, 8-9=-249/747,
<br />7-8=-62/205
<br />WEBS 2-9=-354/93, 5-8=-213/166, 6-8=-205/692,
<br />5-9=-846/267, 6-13=-612/175
<br />NOTES
<br />1)Unbalanced roof live loads have been considered for
<br />this design.
<br />2)Wind: ASCE 7-16; Vult=96mph (3-second gust)
<br />Vasd=76mph; TCDL=8.4psf; BCDL=4.2psf; h=25ft; Cat.
<br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone
<br />and C-C Corner (3) 0-2-12 to 15-3-4 zone; cantilever left
<br />and right exposed ; end vertical left and right
<br />exposed;C-C for members and forces & MWFRS for
<br />reactions shown; Lumber DOL=1.60 plate grip
<br />DOL=1.60
<br />3)Provide adequate drainage to prevent water ponding.
<br />4)This truss has been designed for a 10.0 psf bottom
<br />chord live load nonconcurrent with any other live loads.
<br />5)* This truss has been designed for a live load of 20.0psf
<br />on the bottom chord in all areas where a rectangle
<br />3-06-00 tall by 2-00-00 wide will fit between the bottom
<br />chord and any other members.
<br />6)A plate rating reduction of 20% has been applied for the
<br />green lumber members.
<br />7)Bearings are assumed to be: Joint 1 DF No.2 crushing
<br />capacity of 625 psi, Joint 9 DF No.2 crushing capacity of
<br />625 psi, Joint 13 DF No.2 crushing capacity of 625 psi.
<br />8)Bearing at joint(s) 13 considers parallel to grain value
<br />using ANSI/TPI 1 angle to grain formula. Building
<br />designer should verify capacity of bearing surface.
<br />9)Provide mechanical connection (by others) of truss to
<br />bearing plate capable of withstanding 13 lb uplift at joint
<br />1, 30 lb uplift at joint 9 and 21 lb uplift at joint 13.
<br />10)Beveled plate or shim required to provide full bearing
<br />surface with truss chord at joint(s) 1.
<br />11)This truss has been designed for a moving concentrated
<br />load of 300.0lb live and 80.0lb dead located at all mid
<br />panels and at all panel points along the Top Chord and
<br />Bottom Chord, nonconcurrent with any other live loads.
<br />12)Graphical purlin representation does not depict the size
<br />or the orientation of the purlin along the top and/or
<br />bottom chord.
<br />13)This truss is designed for a creep factor of 2.01, which is
<br />used to calculate the Vert(CT) deflection per ANSI/TPI 1.
<br />The building designer shall verify that this parameter fits
<br />with the intended use of this component.
<br />LOAD CASE(S) Standard
<br />1)Dead + Roof Live (balanced): Lumber Increase=1.25,
<br />Plate Increase=1.25
<br />Uniform Loads (lb/ft)
<br />Vert: 1-2=-68, 2-3=-68, 4-6=-68, 11-18=-30,
<br />7-18=-14
<br />Job Truss Truss Type Qty Ply M39558- TOMS JR SANTA ANA
<br />R80031759AC02Half Hip 1 1M39885- TOMS JR Job Reference (optional)
<br />Builders FirstSource (Perris, CA), Perris, CA - 92570,Run: 8.63 S Nov 1 2023 Print: 8.630 S Nov 1 2023 MiTek Industries, Inc. Wed Dec 27 09:55:39 Page: 1
<br />ID:hZe4JtrhQjWOw6dR8slnksyEn92-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f
<br />December 27,2023
<br />1430 E Edinger Ave
<br />3/27/2025
|