My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1430 E Edinger Ave-REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
1430 E Edinger Ave
>
1430 E Edinger Ave-REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:02:00 AM
Creation date
2/24/2026 5:00:43 AM
Metadata
Fields
Template:
Plan
Permit Number
20183198
20186203
30147418
30148982
40139225
40140476
101119781
101119782
Full Address
1430 E Edinger Ave
Street Number
1430
Street Direction
E
Street Name
Edinger
Street Suffix
Ave
Document Relationships
101119781 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
101119782 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
20183198 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
20186203 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
30147418 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
30148982 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
40139225 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
40140476 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
931
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
K-25 <br />NEW MSB IN THE <br />ELECTRICAL ROOM <br />DRIVE-THRU <br />SERVICE <br />AREA <br />SODA/CO2 <br />48" HIGH PONY WALL <br />K-1 <br />K-2 & 4 <br />K-7&9 <br />K-13 <br />K-15&17K-21&23 <br />K-27 <br />K-3&5 <br />K-29 <br />K-8 K-6 <br />K-11 <br />F <br />K-31&33&35 <br />F <br />K-20,22,24 <br />K-28 <br />K-32 <br />K-37 <br />K-18 <br />K- 26K- 28 K- 30 <br />P <br />K <br />MSB <br />K-15 <br />3 <br />3 <br />2 <br />4 <br />4 <br />P-6 <br />6 <br />6 <br />6 <br />6 <br />P-8 <br />8 <br />P-8 <br />P-4 <br />4 <br />4 <br />L-25 <br />2523 <br />19 <br />17 <br />L-19 <br />15 <br />K-17 <br />K-12 <br />K-10 <br />12 <br />32 <br />32 <br />10 28 <br />1 <br />21 <br />L-21 L-23 <br />L-17 <br />17 <br />17 <br />L-29 <br />L-27 <br />29 <br />27 <br />L-31 <br />31 <br />K-38 <br />38 <br />28 <br />6 <br />6 <br />K-34 <br />34 <br />34 <br />K-36 <br />36 <br />K-38 <br />38 38 <br />K-40 <br />40 <br />6 <br />K-19 <br />K-16 <br />16 <br />40 <br />K-39 <br />K-41 <br />40 <br />FOOD PREP/DISH WASH <br />SECONDARY <br />ENTRANCE <br />DRY STORAGE <br />WAITING AREA <br />DINING TABLE <br />ELECTRICAL <br />EXIT <br />ORDER <br />PICK-UP <br />FREEZER <br />WALK-IN COOLER <br />COOKING LINE <br />MA <br />I <br />N <br /> <br />E <br />N <br />T <br />R <br />Y <br />STORAGE <br />CLOSET <br />SERVICE AREA <br />SINGLE-USER <br />ALL-GENDER <br />RESTROOM <br />SINGLE-USER <br />ALL-GENDER <br />RESTROOM <br />BACK OF HOUSE <br />DINING AREA <br />(TABLED SEATING) <br />2 <br />L <br />SJ <br />P-10 <br />S <br />J <br />K-12 <br />A.EACH RECEPTACLE WITHIN THE KITCHEN/FOOD PREPARATION AREAS <br />SHALL BE GFCI TYPE AS REQUIRED. <br />B.CONTRACTOR TO VERIFY AND COORDINATE EACH RECEPTACLE <br />(OUTLET AND PLUG) WITH THE EQUIPMENT SUBMITTAL/CUT SHEET, <br />KITCHEN EQUIPMENT SCHEDULE AND INSTALLATION MANUAL. <br />C.ALL EQUIPMENT AND DEVICES ARE NEW. PROVIDE ALL NECESSARY <br />ACCESSORIES. <br />D. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES <br />AND OFFSET 24" MINIMUM. <br />E.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE <br />PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED <br />FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF <br />THE WALL. <br />F.ALL WALL-MOUNTED DEVICE HEIGHTS SHALL BE VERIFIED WITH THE <br />ARCHITECT AND KITCHEN CONSULTANT PRIOR TO ROUGH-IN. <br />G.WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE <br />CONTRACTOR WILL NEED TO PROVIDE THE FOLLOWING ITEMS: <br />1.ALL BRANCH CIRCUITS SHALL BE IN EMT. <br />2.ALL BRANCH CIRCUITS SHALL BE ROUTED NEATLY AND IN <br />PARALLEL TO STRUCTURES OR DUCT WORK. <br />3.VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED <br />AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. <br />K.EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL <br />CONFORM TO NEC, OR CEC WHERE ADOPTED, ARTICLE 300.22(C) . <br />GENERAL NOTES: <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />CAD <br />Author <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />1 SCALE: 1/4" = 1'-0" <br />POWER FLOOR PLAN <br />NORTH <br />POWER PLAN <br />E-112 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />2 <br />2 <br />2 <br />2 <br />2 2 <br />2 <br />2 <br />2 <br />2 <br />7 <br />7 <br />8 <br />CONTRACTOR TO VERIFY AND COORDINATE EXACT LOCATION AND RECEPTACLE TYPE <br />WITH EQUIPMENT SUBMITTAL, IN THE FIELD AND WITH OWNER IN THE OFFICE AREA. <br />PROVIDE 60AS, 40AF, 3 POLE DISCONNECT SWITCH. PROVIDE 1"C - 3#8 + 1#10 GRD. VERIFY <br />AND COORDINATE EXACT LOCATION AND POWER REQUIREMENT WITH EQUIPMENT <br />SUBMITTAL AND INSTALLER. <br />PROVIDE CEILING MOUNTED OUTLET FOR SHOW WINDOW. VERIFY EXACT LOCATION IN THE <br />FIELD.(TYPICAL) <br />PROVIDE GFCI 208V RECEPTACLE. VERIFY AND COORDINATE EXACT LOCATION AND TYPE <br />WITH THE EQUIPMENT SUBMITTAL AND IN THE FIELD. <br />PROVIDE 1"C - 3#6 + 1#10 GRD FOR COFFEE MACHINE. VERIFY AND COORDINATE EXACT <br />LOCATION WITH OWNER/ARCHITECT/CONTRACTOR AND IN THE FIELD. <br />PROVIDE CONNECTION TO WALL MOUNTED MOTION SENSOR SWITCH. REFER TO SHEET <br />E-110 FOR LOCATION. REFER TO SHEET E-116 DETAIL #2 FOR COMPLETE INFORMATION. <br />CONTRACTOR TO VERIFY AND COORDINATE EXACT LOCATION WITH EQUIPMENT <br />SUBMITTAL, IN THE FIELD AND WITH OWNER. <br />PROVIDE POWER FOR ANSUL FIRE SUPRESSION AND INTEGRATE WITH FIRE ALARM <br />SYSTEM. VERIFY AND COORDINATE EXACT LOCATION WITH ARCHITECT, OWNER AND <br />KTICHEN DRAWING. <br />KEY NOTE <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />1 <br />7 <br />8 <br />1430 E Edinger Ave <br />3/27/2025
The URL can be used to link to this page
Your browser does not support the video tag.