Laserfiche WebLink
C <br />N <br />G <br />B <br />A <br />INCOMING 4 #6AWG, #10AWG E.G. <br />FEEDER CONDUCTORS IN 1" CONDUIT <br />CONNECT TO ALTERNATE <br />PHASE (TYPICAL) <br />TYPICAL CIRCUIT <br />BREAKER 1P, 20A, <br />120V, 10,000 KAIC <br />UON. <br />SURFACE METAL <br />RACEWAY ASSEMBLY <br />DUPLEX GROUNDING TYPE <br />RECEPTACLE RATED AT <br />125V, 20A, NEMA 5-20R (USE <br />GROUND FAULT <br />INTERRUPTER TYPE <br />WHERE INDICATED) <br />SURFACE MOUNTED <br />RACEWAY ENTRANCE <br />JUNCTION BOX <br />TOGGLE SWITCH FOR <br />UNDERSHELF <br />LIGHTING FIXTURES <br />MOUNTED IN METAL <br />RACEWAY <br />A, B OR C <br />N <br />G <br />UNDERSHELF <br />LIGHTING FIXTURE <br />EMT <br />EMT <br />UNDERCOUNTER <br />DUPLEX GROUNDING <br />TYPE RECEPTACLE <br />RATED AT 125V, 20A, <br />NEMA 5-20R <br />2P, 20A OR 30A CIRCUIT <br />BREAKER <br />2P, 3W GROUNDING <br />TYPE RECEPTACLE - <br />250V <br />NEMA 6-20R / 6-30R <br />EMT <br />G <br />EQUIPMENT GROUND <br />CONDUCTOR BONDED TO <br />EACH SURFACE METAL <br />RACEWAY SECTION, <br />INCLUDING FITTINGS. <br />USE #10 AWG <br />FOR ALL <br />SPECIALTY <br />RECEPTACLE <br />SURFACE METAL RACEWAY WIRING DETAILGROUND ROD DETAIL 1NTS3NTS <br />LIQUIDTIGHT <br />TO ALL OTHER <br />U.S. FIXTURES <br />CONTINUED TO <br />OTHER <br />FIXTURESNOTE: <br />CONNECT GROUNDING ELECTRODE <br />CONDUCTOR TO ALL AVAILABLE GROUNDING <br />ELECTRODES THAT ARE PRESENT AT EACH <br />BUILDING TO FORM GROUNDING ELECTRODE <br />SYSTEM CEC ARTICLE 250.50 <br />NOTES: <br />A. THE GROUND ROD OR PIPE MUST HAVE A RESISTANCE <br />TO EARTH OF 25 OHMS OR LESS, OR BE SUPPLEMENTED <br />BY AN ADDITIONAL ELECTRODE PER CEC 250.53(A)(2). <br />B.WHEN USING MULTIPLE ROD, THEY MUST SPACED AT <br />LEAST 6 FT. APART. <br />C. GROUND ROD ELECTRODES MUST MEET AND QUALIFY <br />AS A GROUNDING ELECTRODE ARE AS FOLLOWS: <br />- NOT LESS THAN 8 FT IN LENGTH <br />- ROD-TYPE GROUNDING ELECTRODES MUST CONSIST <br />OF THE <br /> FOLLOWING MATERIALS: <br />- STAINLESS OR COPPER OF ZINC COATED <br />- AT LEAST 15.87 MM (5/8") IN DIAMETER, UNLESS LISTED. <br />#4/0 GROUND WIRE TO <br />ELEVATOR SYSTEM <br />TRAFFIC RATED COVER <br />GROUND LEVEL <br />12" MIN <br />6" <br />MIN <br />GROUND CONNECTOR <br />(TYP.) <br />COPPER GROUND ROD <br />3/4" DIA x 10'-0" <br />6" <br />MIN <br />#6 AWG CU <br />CEC 250.66(A) <br />GROUNDING DETAIL 2NTS <br />CONNECT GROUNDING <br />ELECTRODE CONDUCTOR <br />WITHIN FIRST 5FT OF <br />WHERE METAL WATER <br />PIPING ENTERS BUILDING. <br />250.68 (C)(1) <br />METAL UNDERGROUND <br />WATER PIPE IF IN DIRECT <br />CONTACT WITH THE EARTH <br />FOR 10FT OR MORE CEC <br />250.52(A)(1) <br />MAIN SWITCHBOARD <br />GROUNDING BUS BAR <br />NOTE: <br />CONNECT GROUNDING ELECTRODE <br />CONDUCTOR TO ALL AVAILABLE GROUNDING <br />ELECTRODES THAT ARE PRESENT AT EACH <br />BUILDING TO FORM GROUNDING ELECTRODE <br />SYSTEM CEC ARTICLE 250.50 <br />(N) 3/4"C - 1#3/0 GEC <br />METAL FRAME OF THE <br />BUILDING <br />AS PER CEC 250.52(A)(2) <br />MAIN SERVICE EQUIPMENT <br />M <br />BONDING JUMPER AROUND METER <br />MAIN BONDING JUMPER <br />NEUTRAL BUS <br />GROUND ROD <br />EXOTHERMIC <br />WELD(TYPICAL) <br />#6 AWG CU <br />CEC 250.66(A) <br />NOTES: <br />A. THE GROUND ROD OR PIPE MUST HAVE A RESISTANCE TO <br />EARTH OF 25 OHMS OR LESS, OR BE SUPPLEMENTED BY AN <br />ADDITIONAL ELECTRODE PER CEC 250.53(A)(2). <br />B.WHEN USING MULTIPLE ROD, THEY MUST SPACED AT LEAST 6 <br />FT. APART. <br />C. GROUND ROD ELECTRODES MUST MEET AND QUALIFY AS A <br />GROUNDING ELECTRODE ARE AS FOLLOWS: <br />- NOT LESS THAN 8 FT IN LENGTH <br />- ROD-TYPE GROUNDING ELECTRODES MUST CONSIST OF <br />THE FOLLOWING MATERIALS: <br />- STAINLESS OR COPPER OF ZINC COATED <br />- AT LEAST 15.87 MM (5/8") IN DIAMETER, UNLESS LISTED. <br />NOTE: <br />1.MAXIMUM FOUR DUPLEX RECEPTACLES ON <br />ANY SINGLE 20A CIRCUIT BREAKER. <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />CAD <br />Author <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />ELECTRICAL <br />DETAILS <br />E-115 <br />2'-6" <br />REF STRUCT <br />POLE BASE DETAIL <br />NOTE <br />1.FOR TOTAL HEIGHT OF POLE FROM GROUND REFER TO PHOTOMETRIC PLAN. <br />HANDHOLE W/NON-FERROUS TAMPER <br />PROOF SCREWS <br />GALV. STEEL BASE PLATE BOLTS AND <br />WASHERS <br />1"X45° CHAMFER <br />PROVIDE 1/2 TIE SPACING ABOVE <br />GRADE <br />(4) 1"X36" GALV STEEL ANCHOR RODS <br />FINISH GRADE <br />CONDUIT & CONDUCTORS, SEE SITE <br />PLAN FOR POWER & SIZE <br />REINF. RODS, REFER TO STRUCTURAL <br />PLANS <br />CONCRETE BASE <br />REF STRUCT <br />EXOTHERMIC WELD <br />BASE COVER <br />POLE <br />NOTE 1 <br />20'-0" BARE #6 <br />CU. IN GROUND <br />UNDER BASE <br />4NTS <br />1430 E Edinger Ave <br />3/27/2025