My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1430 E Edinger Ave-REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
1430 E Edinger Ave
>
1430 E Edinger Ave-REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:02:00 AM
Creation date
2/24/2026 5:00:43 AM
Metadata
Fields
Template:
Plan
Permit Number
20183198
20186203
30147418
30148982
40139225
40140476
101119781
101119782
Full Address
1430 E Edinger Ave
Street Number
1430
Street Direction
E
Street Name
Edinger
Street Suffix
Ave
Document Relationships
101119781 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
101119782 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
20183198 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
20186203 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
30147418 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
30148982 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
40139225 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
40140476 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
931
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A <br />A <br />SECTION A-A <br />UL# W-L-1074 <br />SYSTEM NO. <br />W-L-1074 <br />F RATINGS - 1HR <br />RECTORSEAL -METACAULK 950 OR EQUAL <br />INSTALLATION TO COMPLY WITH <br />MANUFACTURER'S INSTRUCTIONS <br />4 <br />5 <br />2 <br />1 <br />3 <br />TYP. FIRE PENETRATION GYPSUM WALL ASSEMBLY <br />REFERENCE NOTES: <br />WALL ASSEMBLY - THE FIRE RATED GYPSUM <br />WALBOARD/STUD WALL ASSEMBLY <br />STUDS - WALL FRAMING WOOD STUDS OR STEEL <br />CHANNEL STUDS. <br />WALLBOARD GYPSUM - ONE LAYER OF NOM 5 8 IN. <br />THICK GYPSUM WALLBOARD. <br />CONDUIT TO BE SUPPORTED ON BOTH SIDES OF <br />WALL ASSEMBLY. THE ANNULAR SPACE BETWEEN <br />THE THROUGH - PENETRANT AND THE PERIPHERY <br />OF THE OPENING SHALL BE MIN. 0 IN. TO MAX 14 IN. <br />THE FOLLOWING TYPES OF CONDUITS OR TUBING <br />MAY BE USED: CONDUIT-NOM 6 IN. DIAM (OR <br />SMALLER) STEEL ELECTRICAL METALLIC TUBING <br />OR STEEL CONDUIT. <br />FILL VOID OR CAVITY MATERIAL - CAULK - FILL <br />MATERIAL TO BE FORCED INTO THE ANNULUS TO <br />MAXIMUM EXTENT POSSIBLE. ADDITIONAL FILL <br />MATERIAL TO BE INSTALLED SUCH THAT A MIN. 12 IN. <br />CROWN IS FORMED AROUND THE PENETRATING <br />ITEM AND LAPPING 14 IN. BEYOND THE PERIPHERY <br />OF THE OPENING. <br />1 <br />2 <br />3 <br />4 <br />5 <br />NELSON FIRESTOP PRODUCTS - TYPE CMP <br />MORTAR OR EQUAL <br />INSTALLATION TO COMPLY WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />SECTION A-A <br />UL# C-AJ-8007 <br />SYSTEM NO. C-AJ-8007 <br />F RATINGS - 2 AND 3 HR <br />A <br />A <br />2 <br />2 22 <br />2 <br />245 <br />TYP. FIRE PENETRATION ASSEMBLY CONCRETEACCESSIBLE REACH LIMITS <br />FOR EXACT LOCATIONS <br />OF WIRING DEVICES, SEE <br />A-SERIES DRAWINGS <br />48" <br />MAX 46" <br />MAX <br />10" <br />MAX <br />24" <br />MAX <br />34" <br />MAX <br />30" <br />MAX <br />30" <br />MAX <br />15" <br />MIN <br />* <br />* <br />* <br />FLOOR & WALL ASSEMBLY - MIN. 314 IN. THICK <br />REINFORCED LIGHTWEIGHT ON NORMAL WEIGHT <br />(100-150 PCF) CONCRETE. WALL MAY ALSO BE <br />CONSTRUCTED ON ANY UL CLASSIFIED CONCRETE <br />BLOCKS. MAX OF OPENING IS 300 SQ IN WITH MAX <br />DIMENSION OF 30 IN. <br />THROUGH PENETRANTS - A MAX OF FIVE CONDUITS <br />SPACE BETWEEN CONDUITS OR TUBING SHALL BE <br />MIN 3 4 IN. TO MAX 112 IN. THE SPACE BETWEEN <br />CONDUITS OR TUBING AND PERIPHERY OF OPENING <br />SHALL BE MIN 3 4 IN. TO MAX 13 4"IN. CONDUITS, <br />CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED <br />ON BOTH SIDES FOR FLOOR OR WALL ASSEMBLY. <br />CONDUIT-NOM 4 IN. DIA. (OR SMALLER) ELECTRICAL <br />METALLIC TUBING OR NOM 6 IN. (OR SMALLER) <br />RIGID STEEL CONDUIT. <br />FORMS-(NOT SHOWN) <br />FORMS TO BE RIGID SHEET MATERIAL, CUT IT FIT <br />THE CONDUCTOR OF THE PENETRATING ITEM AND <br />FASTENED TO THE UNDERSIDE OF FLOOR OR BOTH <br />SIDES OF WALL. FORMS TO BE REMOVED AFTER <br />FILL MATERIAL HAS CURED. <br />FILL VOID OR CAVITY MATERIAL WRAP MATERIAL - <br />SINGLE LAYER OF A CERAMIC FIBER INSULATION <br />COVERED ON BOTH SURFACES WITH A FOIL FACING. <br />THE WRAP MATERIAL SHALL EXTEND A MIN. OF 6 IN. <br />BEYOND BOTH SURFACES OF THE ASSEMBLY AND <br />SHALL BE SECURED TOGETHER WITH MIN. NO.12 <br />AWG STEEL WIRE FILL VOID OR CAVITY MATERIAL <br />MORTAR. <br />FILL MATERIAL APPLIED WITHIN THE ANNULUS, <br />FLUSH WITH TOP SURFACE OF FLOOR OR WITH <br />BOTH SURFACES OF WALL. <br />1 <br />2 <br />3 <br />4 <br />5 <br />CONDUIT <br />MOUNTING STRAP <br />GREEN HEX HEAD <br />GROUND SCREW <br />CONNECTION <br />N <br />Ø <br />N <br />Ø <br />EG <br />EG <br />EG <br />INTERSTITIAL SPACE PANEL MOUNTING DETAIL <br />GROUND ROD STRUCTURAL STEEL CONNECTION RECEPTACLE WIRING DETAIL <br />SECURELY ANCHOR CHANNEL TO <br />CONCRETE FLOOR SLAB (TYP) <br />ALUMINUM <br />CHANNEL SUPPORT <br />TYPICAL LAB <br />ELECTRICAL PANEL <br />FASTENED TO <br />CHANNEL. <br />INTERSTITIAL LEVEL <br />STEEL FLOOR DECK. <br />STRUCTURAL <br />FLOOR SLAB. <br />CHANNEL TO BE <br />SECURELY <br />FASTENED TO <br />FLOOR DECK (TYP). <br />OUTLET <br />BOX <br />ISOLATED <br />GROUND <br />ISOLATED GROUND <br />RECEPTACLE <br />IG BUS <br />EG BUS <br />NORMAL "COMMON" <br />BUILDING GROUND (EG) <br />GREEN HEX HEAD <br />GROUND SCREW <br />CONNECTION <br />MOUNTING STRAP <br />BONDING <br />JUMPER <br />OUTLET <br />BOX <br />CONVENTIONAL <br />RECEPTACLE <br />CADWELD CONNECTION TO <br />BUILDING STEEL <br />STRUCTURAL STEEL <br />CABLE <br />GROUND ROD CONNECTION <br />19mm X 3050mm (3/4" X 10'-0") LONG <br />COPPERCLAD GROUND ROD <br />BUILDING SYSTEM <br />EXTERIOR GROUND <br />LOOP <br />REFERENCE NOTES: <br />2NTS <br />1NTS3NTS5NTS <br />4NTS6NTS <br />ELECTRICAL LIGHT SWITCH <br />OR RECEPTACLE LOCATION. <br />INSTALL PER ADA STANDARD <br />MAXIMUM SIDE REACH <br />OVER OBSTRUCTION <br />HIGH AND LOW <br />SIDE REACH LIMITS <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />CAD <br />Author <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />ELECTRICAL <br />DETAILS <br />E-114 <br />1430 E Edinger Ave <br />3/27/2025
The URL can be used to link to this page
Your browser does not support the video tag.