PACKAGED GAS/ELECTRIC ROOFTOP UNIT SCHEDULE <br />MARK MFR. AND MODEL <br />NUMBER <br />NOM. <br />CAP. <br />(TONS) <br />LOC. <br />E.S.P. <br />(IN. <br />WG.) <br />EFFICIENCY <br />AIRFLOW <br />(CFM) <br />MIN. <br />O.A. <br />(CFM) <br />TOTAL <br />CLG <br />CAP. <br />(MBH) <br />TOTAL HTG. CAP.ELECTRICAL DATA POWER EXHAUST <br />DRAIN <br />SIZE (IN.) <br />NET. WT. <br />(LBS.)REMARKS <br />EER SEER AFUE INPUT <br />(MBH) <br />OUTPUT <br />(MBH)V./ PH./ HZ.MCA MOCP HP FLA LRA <br />TRANE YHC060F3 <br />OR APPROVED <br />EQUAL <br />5.00 ROOF 0.8 12.9 15.0 80%2000.0 780.0 61.0 80.0 64.0 208-230/3/60 30 45 0.33 2.2 3.9 1-3/4" NPT 755 1 - 8 <br />TRANE YHC036E3 <br />OR APPROVED <br />EQUAL <br />3.00 ROOF 0.8 12.7 15.0 80%1200.0 200.0 37.6 60.0 48.0 208-230/3/60 21 30 0.33 2.2 3.9 1-3/4" NPT 540 1 - 6, 8 <br />REMARKS: <br />1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. <br />2. PROVIDE WITH NEW T24 APPROVED PROGRAMMABLE THERMOSTAT. <br />3. PROVIDE WITH 2" THICK HIGH EFFICIENCY MERV-13 PLEATED PANEL FILTERS. <br />4. CONTRACTOR TO VERIFY IN FIELD THE SERVICEABILITY OF THE EXISTING ROOF CURB. REPLACE AS NECESSARY. <br />5. PROVIDE WITH PREMIUM EFFICIENCY MOTORS AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. <br />6. PROVIDE WITH POWER EXHAUST AND FACTORY INSTALLED FIXED DRY BULB TEMPERATURE ECONOMIZER WITH BAROMETRIC RELIEF. <br />7. PROVIDE WITH SMOKE DETECTORS AT THE SUPPLY SIDE TO CONNECT TO THE BUILDING FORE PROTECTION SYSTEM (IF APPLICABLE), AND SHUTDOWN AC WHEN ACTIVATED. IN CASE THERE IS NO EXISTING FIRE <br />PROTECTION SYSTEM, NO NEED TO PROVIDE CONNECTION WITH SMOKE DETECTOR. <br />8. REPLACE EXISTING PACKAGED GAS/ELECTRIC ROOFTOP UNIT. <br />800-R <br />10"Ø NK A <br />AIR DEVICE DATA TAG <br />DIFFUSER <br />MARK <br />AIR <br />QUANTITY <br />(CFM) <br />S=SUPPLY <br />R=RETURN <br />E=EXHAUST <br />NECK SIZE <br />EQUIPMENT TAG <br />EQUIPMENT TAG <br />NUMBER <br />NOTE TO ALL BIDDERS: <br />THE PROJECT IS NOT READY TO ISSUE (RTI). SOME ITEMS <br />ARE SUBJECT TO CHANGE TO PLANCHECK COMMENTS <br />AND CONTINUING COORDINATION. <br />GENERAL NOTES <br />FCU <br />4 <br />EXISTING DUCTWORK OR <br />EQUIPMENT TO BE REMOVED <br />ABBREV.SYMBOL DESCRIPTION <br />(D) <br />(E)EXISTING DUCTWORK OR <br />EQUIPMENT TO BE REMAIN <br />48x36 <br />(N)NEW DUCTWORK OR <br />EQUIPMENT. DUCT SIZE <br />NOTATION W/SIZE OF NEAREST <br />SIDE INDICATED FIRST <br />CD <br />SG <br />RG <br />EG <br />CEILING SUPPLY DIFFUSER <br />SUPPLY GRILLE <br />RETURN AIR GRILLE OR <br />REGISTER <br />EXHAUST GRILLE <br />MVD <br />BDD <br />FSD <br />MANUAL VOLUME DAMPER <br />BACKDRAFT DAMPER <br />FIRE SMOKE DAMPER <br />T TSTAT THERMOSTAT <br />POS POINT ON CONNECTION <br />SD SD SMOKE DETECTOR <br />ARCH <br />ABV <br />AFF <br />BEL <br />BOT <br />CD <br />CFM <br />FT <br />OBD <br />N.T.S <br />NK <br />TYP <br />UC <br />ARCHITECT <br />ABOVE <br />ABOVE FINISHED FLOOR <br />BELOW <br />BOTTOM <br />CONDENSATE DRAIN <br />CUBIC FEET PER MINUTE <br />FOOT / FEET <br />OPPOSED BLADE DAMPER <br />NOT TO SCALE <br />NECK <br />TYPICAL <br />DOOR UNDERCUT <br />SCHEDULES <br />1.ALL ENVIRONMENTAL EXHAUST DUCTS SHALL BE OF SHEET METAL, TERMINATED 3 FT. <br />AWAY FROM OPENINGS INTO THE BUILDING AND 3 FT. FROM PROPERTY LINE. <br />2.ALL CONDENSATE LINE SHALL BE ROUTED, SLOPED AND CONNECTED TO THE NEAREST <br />LAVATORY TAILPIECE OR APPROVED PLUMBING RECEPTOR. <br />3.CONTRACTOR SHALL IINSTALL REQUIRED HVAC COMPONENTS TO FIT ACTUAL JOB <br />CONDITIONS WITHOUT IMPAIRING THE DESIGN CONCEPT. <br />4.CONTRACTOR SHALL INCLUDE ANY DUCT TURNS OR ANY ADDITIONAL APPURTENANCES <br />NECESSARY FOR THE PROPER FUNCTION OF THE SYSTEM EVEN THOUGH THEY ARE NOT <br />SHOWN ON THE DRAWINGS. <br />5.ALL REFRIGERANT PIPING SHALL BE SIZED AND INSTALLED PER MANUFACTURER'S <br />RECOMMENDATIONS. <br />6.ALL AIR FILTERS SHALL BE MINIMUM MERV-13 FILTERS. FILTER SIZES SHALL MATCH THE <br />SIZES OF THE RETURN AIR GRILLES. <br />7.CONTRACTOR SHALL MAKE ALL NECESSARY OFFSETS AND TRANSITION IN ORDER TO <br />ACCOMMODATE DUCTWORK AND PIPING THAT CROSS WITH ONE ANOTHER INSIDE THE <br />SOFFIT AREA. <br />8.CONTRACTOR SHALL PROVIDE NECESSARY SUPPORT MEMBRANE AND ASSOCIATED <br />COMPONENTS IN ORDER TO MINIMIZE THE SPACE BETWEEN THE TOP OF FAN COIL UNIT <br />AND THE STRUCTURE ABOVE. <br />9.ALL DUCTWORK SHALL BE ROUTED AS TIGHT AS POSSIBLE TO THE STRUCTURE ABOVE. <br />10.ALL EQUIPMENT SUBJECT TO NOISE-PRODUCING VIBRATIONS SHALL BE MOUNTED ON <br />VIBRATION ISOLATORS WITH FLEXIBLE CONNECTIONS TO RELATING EQUIPMENT. ALL <br />EQUIPMENT SHALL BE LABELED IN ACCORDANCE WITH THE PLANS. <br />11.PROVIDE LABELS AT ALL THERMOSTATS INDICATING THE UNIT DESIGNATION <br />(COORDINATE WITH LABELING AT UNITS). CHECK THERMOSTATS LABEL AND REPLACE IF <br />NOT LEGIBLE. <br />12.CONTRACTOR SHALL ADJUST SUPPLY AIR GRILLES, REGISTERS AND DIFFUSERS TO <br />ACHIEVE PROPER AIR QUANTITIES AND THROW DISTRIBUTION OF AIR IN SPACE. <br />CONTROL DAMPERS SHALL BE WITH LOCKING QUADRANTS ON OUTSIDE AIR DUCTING. <br />13.DUCTWORK WITH EXTERNAL INSULATION SHALL HAVE LOCKING QUADRANTS WITH <br />ELEVATED DIAL REGULATOR SPRING END BEARING OR EQUAL. <br />14.CONTRACTOR SHALL INSTALL REQUIRED HVAC COMPONENTS TO FIT ACTUAL JOBSITE <br />CONDITIONS WITHOUT IMPAIRING THE CONCEPT OF THE DESIGN. <br />15.CONTRACTOR SHALL VERIFY IN THE FIELD THE LOCATION OF NEW UNITS AND <br />EQUIPMENT FOR ACCESSIBILITY PER MANUFATURER'S RECOMMENDATIONS AND <br />APPLICABLE CODES PRIOR TO PURCHASING AND INSTALLATION. <br />16.CONTRACTOR SHALL PROVIDE TRAVERSE READING AT ALL FAN SYSTEM SUPPLY, <br />RETURN AND EXHAUST DUCTS. VERIFY AIR AMOUNT AND CHECK FOR DUCT LEAKS. <br />LEAKS IN DUCTWORK SHALL NOT EXCEED SMACNA STANDARDS. CONTRACTOR TO <br />PROVIDE ALL NECESSARY CORRECTIVE ACTION. CONTRACTOR SHALL CHANGE FAN <br />RPM TO MEET FIELD PRESSURE CONDITIONS INCLUDING CHANGING OF SHEAVES AS <br />REQUIRED. <br />17.CONTRACTOR SHALL SET AIR EQUIPMENT, DAMPERS, STATIC FITTINGS, FAN RPM FOR <br />DELIVERING AIR QUANTITIES AT ACTUAL FIELD CONDITIONS ACCORDING TO DESIGN. <br />18.LISTED SMOKE DAMPERS AND FIRE DAMPERS ARE REQUIRED TO BE INSTALLED AT ALL <br />DUCT PENETRATIONS THROUGH AREA SEPARATION, OCCUPANCY SEPARATION WALLS, <br />FIRE RATED CEILING, AND FIRE RATED SHAFTS PER CMC 2019. DAMPERS SHALL BE LIKED <br />TO FIRE ALARM SYSTEM WITH DEDICATED ELECTRICAL POWER. <br />19.PROVIDE ACOUSTICAL LINING ON EVERY MAIN DUCT 10' AWAY FROM THE AC UNIT. <br />20.DUCT SYSTEM SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6% OF THE <br />NOMINAL AIR HANDLER AIRFLOW RATE AS CONFIRMED THROUGH FIELD VERIFICATION <br />AND DIAGNOSTIC TESTING. <br />21.OUTDOOR AIR RATES SHALL BE BALANCED WITHIN 10% OF THE DESIGN OUTSIDE AIR <br />RATE. <br />22.CONTRACTOR SHALL PROVIDE AIR BALANCING DAMPERS AT BRANCH TAKE-OFFS <br />WETHER STATED IN THE PLANS OR NOT. <br />23.ALL MECHANICAL VENTILATION AND SPACE CONDITIONING SYSTEMS SHALL BE <br />INSTALLED WITH DUCTWORK, DAMPERS, AND CONTROLS TO ALLOW OUTSIDE AIR RATES <br />TO BE OPERATED AT THE LARGER OF (1) THE MINIMUM LEVELS SPECIFIED IN SECTION <br />120.1(b) OR (2) THE RATE REQUIRED FOR MAKE UP OF EXHAUST SYSTEMS THAT ARE <br />REQUIRED FOR AN EXEMPT OR COVERED PROCESS FOR CONTROL OF ODORS, OR FOR <br />THE REMOVAL OF CONTAMINANTS WITH IN THE SPACE. ALL VARIABLE AIR VOLUME <br />SPACE-CONDITIONING SYSTEMS SHALL INCLUDE CONTROLS THAT MAINTAIN MEASURED <br />OUTSIDE AIR VENTILATION RATES WITHIN 10 PERCENT OF THE REQUIRED OUTSIDE AIR <br />VENTILATION RATE AT BOTH FULL AND REDUCED SUPPLY AIRFLOW CONDITIONS. <br />SEC.120.1(e) <br />RTU <br />1 <br />RTU <br />2 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />DC <br />TT <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />KITCHEN EXHAUST FAN SCHEDULE <br />MARK MFR & MODEL NUMBER LOCATION SERVICE CFM E.S.P. (IN. <br />WG.) <br />DISCH. <br />FPM FAN RPM SONES <br />ELECTRICAL DATA NET. <br />WT. <br />(LBS.) <br />QTY.REMARKS <br />V./ PH./ HZ.HP BHP FLA <br />CAPTIVEAIRE USBI24DD-RM <br />OR APPROVED EQUAL ROOF H-1, H-2 5,600 2.5 2122 1254 32.11 208/3/60 7.5 4.61 21.1 859 1 1 - 7 <br />CAPTIVEAIRE USBI13DD-RM <br />OR APPROVED EQUAL ROOF H-3 1,000 1.25 875 1425 11.0 208/1/60 1 0.3 6.9 215 1 1 - 7 <br />REMARKS: <br />1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. <br />2. PROVIDE WITH PREMIUM EFFICIENCY MOTORS AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. <br />3. PROVIDE WITH HOOD ON/OFF TOGGLE SWITCH. INTERLOCK WITH THE CONTROL PANEL. <br />4. FAN TO RUN CONTINUOUSLY DURING OPERATING HOURS. <br />5. KITCHEN EXHAUST FAN AND ACCESSORIES SHALL BE FURNISHED THRU CAPTIVEAIRE AND SHALL BE INSTALLED BY MECHANICAL CONTRACTOR. <br />6. PROVIDE WITH PREMIUM EFFICIENCY MOTORS AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. <br />7. REFER TO MECHANICAL HOOD DETAILS SHEET M-212 TO M-224. <br />MAKE-UP AIR UNIT SCHEDULE <br />MARK MFR & MODEL NUMBER LOC.SERVICE <br />FAN EVAP. COOLER ELECTRICAL DATA <br />SONES <br /> NET. <br />WT. <br />(LBS.) <br />QTY.REMARKS <br />CFM <br />E.S.P. <br />(IN. <br />WG.) <br />HP BHP RPM EAT <br />DB (̊F) <br />EAT <br />WB <br />(̊F) <br />LAT <br />DB (̊F) <br />LAT <br />WB <br />(̊F) <br />V./ PH./ HZ.FLA MCA MOCP <br />CAPTIVEAIRE A2-20D OR <br />APPROVED EQUAL ROOF KITCHEN <br />EXHAUST 5940 0.50 10 5.72 1444 90.0 69.0 74.0 69.0 208/3/60 14.5 33.8 60 24.1 970 1 1 - 9 <br />REMARKS: <br />1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. <br />2. INTERLOCK TO OPERATE WHEN KEF-1 AND KEF-2 IS ACTIVATED. <br />3. PROVIDE CIRCULATING PUMP, 3/4" MAKE UP WATER CONNECTION, 2/4" RAIN LINE. <br />4. PROVIDE EVAPORATOR COOLING WITH COOLING SENSOR AND HI-PRO POLYESER COATING FOR OUTSIDE EQUIPMENT INSTALLATION. <br />5. PROVIDE WITH NEOPRENE BLOWER VIBRATION ISOLATION, ROOF CURB AND RAIL. <br />6. PROVIDE WITH PREMIUM EFFICIENCY MOTORS AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. <br />7. PROVIDE WITH TOGGLE ON/OFF SWITCH. INTERLOCK TO CONTROL PANEL. <br />8. PROVIDE WITH SMOKE DETECTORS AT THE SUPPLY SIDE TO CONNECT TO THE BUILDING FORE PROTECTION SYSTEM (IF APPLICABLE), AND SHUTDOWN AC WHEN ACTIVATED. <br />9. REFER TO MECHANICAL HOOD DETAILS SHEET M-212 TO M-224. <br />KEF <br />1 <br />KEF <br />2 <br />MAU <br />1 <br />KITCHEN EXHAUST HOOD SCHEDULE <br />MARK MFR & MODEL NUMBER SERVICE EXHAUST CFM VELOCITY <br />(FPM) <br />EXHAUST DUCT <br />SIZE <br />EXHAUST S.P. <br />(IN. WG.) <br />DIMENSIONS <br />REMARKS <br />LENGTH WIDTH HEIGHT <br />CAPTIVEAIRE 5424-ND-2 OR <br />APPROVED EQUAL AS SHOWN 3,575 2,023 18" DIA.-1.328 13'-0"54"24"1 - 2 <br />CAPTIVEAIRE 5424-ND-2 OR <br />APPROVED EQUAL AS SHOWN 2,025 1,146 18" DIA.-0.504 9'-0"54"24"1 - 2 <br />CAPTIVEAIRE 5424-ND-2 OR <br />APPROVED EQUAL AS SHOWN 1,000 1,273 12" DIA.-0.498 4'-6"54"24"1 - 2 <br />REMARKS: <br />1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. <br />2. REFER TO MECHANICAL HOOD DETAILS SHEET M-212 TO M-224. <br />H <br />1 <br />H <br />2 <br />H <br />3 <br />AIR BALANCE SCHEDULE <br />MARK OUTSIDE AIR (CFM)EXHAUST AIR (CFM)DIFFERENCE (CFM) <br />RTU-1 780 +780 <br />RTU-2 200 +200 <br />EF-1 50 -50 <br />EF-2 100 -100 <br />EF-3 50 -50 <br />EF-4 50 -50 <br />KEF-1 5600 -5600 <br />KEF-2 1000 -1000 <br />MAU-1 5940 +5310 <br />TOTAL 6920 6850 +70 <br />GENERAL NOTES <br />SYMBOLS & <br />SCHEDULE <br />M-201 <br />LEGEND AND ABBREVIATIONS <br />IDENTIFICATION SYMBOLS 1 <br />1 <br />1 <br />1430 E Edinger Ave <br />3/27/2025