My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1430 E Edinger Ave-REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
1430 E Edinger Ave
>
1430 E Edinger Ave-REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:02:00 AM
Creation date
2/24/2026 5:00:43 AM
Metadata
Fields
Template:
Plan
Permit Number
20183198
20186203
30147418
30148982
40139225
40140476
101119781
101119782
Full Address
1430 E Edinger Ave
Street Number
1430
Street Direction
E
Street Name
Edinger
Street Suffix
Ave
Document Relationships
101119781 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
101119782 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
20183198 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
20186203 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
30147418 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
30148982 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
40139225 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
40140476 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
931
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FD <br />FD FD <br />H <br />3 <br />H <br />1 <br />H <br />2 <br />EF <br />3 <br />EF <br />1 <br />EF <br />2 <br />12"Ø NK B450-S <br />14"Ø NK B720-S <br />TYP-6 <br />6"Ø <br />6" <br />Ø <br />6" <br />Ø <br />6" <br />Ø <br />EF <br />4 <br />26"x12" SA <br />22 <br />" <br />x <br />1 <br />2 <br />" <br /> <br />R <br />A <br />10"Ø NK <br />320-SA <br />10"Ø NK <br />320-SA 10"Ø NK <br />300-SA <br />10"Ø NK <br />320-SA <br />10"Ø NK <br />320-SA <br />10"Ø NK <br />320-SA <br />10"Ø NK <br />400-SA <br />10"Ø <br />12 <br />" <br />x <br />1 <br />2 <br />" <br />16 <br />" <br />x <br />1 <br />2 <br />" <br />20 <br />" <br />x <br />1 <br />2 <br />" <br />22 <br />" <br />x <br />1 <br />2 <br />" <br />10"Ø <br />16"Ø RA <br />12"Ø NK B450-S <br />6"Ø NK <br />200-SA <br />8"Ø NK <br />150-SA <br />8"Ø NK A200-S <br />16"Ø NK C1000-R <br />TT <br />8"Ø NK A200-S <br />14"Ø <br />SD <br />31 <br />4 <br />4 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />9 <br />11 <br />10 <br />12 <br />12 <br />12 <br />12 <br />13 <br />13 <br />13 <br />13 <br />14"Ø NK <br />610-RC <br />32 <br />SD22"Ø 18"Ø <br />8"Ø NK <br />150-SA <br />8 <br />10 <br />" <br />Ø <br />16 <br />" <br />Ø <br />8"Ø 10"Ø <br />8"Ø <br />8"Ø 8"Ø <br />14 <br />" <br />Ø <br />12"Ø <br />12"Ø <br />14 <br />" <br />Ø <br />RTU-1 SUPPLY AND RETURN DUCT RISER/DROP FROM ROOF. PROVIDE ALL TRANSITIONS. <br />LOCATE RISER/DROP BETWEEN AVAILABLE JOIST SPACES. <br />RTU-2 SUPPLY AND RETURN DUCT RISER/DROP FROM ROOF. PROVIDE ALL TRANSITIONS. <br />LOCATE RISER/DROP BETWEEN AVAILABLE JOIST SPACES. <br />PROVIDE 1" ACOUSTIC LINER FOR AT LEAST 15 FEET OF DUCT FROM THE ROOFTOP UNIT. <br />TYPICAL FOR BOTH SUPPLY AND RETURN. <br />NEW TYPE I HOOD. REFER TO SHEET M0.01 AND M4.03 TO M4.15 FOR EQUIPMENT DETAILS AND <br />SPECIFICATIONS. HOOD SHALL BE SECURED IN PLACE TO RESIST THE LATERAL LOADS. <br />22"Ø TYPE I KITCHEN HOOD EXHAUST DUCT RISER T/A, CONNECTED TO KEF-1 LOCATED AT THE <br />ROOF DECK. PROVIDE WITH DOUBLE WALL DUCT TO BE INSTALLED PER MANUFACTURER'S <br />RECOMMENDATION. <br />12"Ø TYPE I KITCHEN HOOD EXHAUST DUCT RISER T/A, CONNECTED TO KEF-2 LOCATED AT THE <br />ROOF DECK. PROVIDE WITH DOUBLE WALL DUCT TO BE INSTALLED PER MANUFACTURER'S <br />RECOMMENDATION. <br />24"x24" MAKE-UP AIR DUCT RISER F/A. PROVIDE DUCT TRANSITION AND FLEXIBLE CONNECTION <br />CONNECTING TO MAU-1. PROVIDE AIR BALANCING DAMPER IN THE MAKE-UP AIR DUCT THAT IS <br />ACCESSIBLE FOR AIR BALANCE CONTRACTOR. <br />PROVIDE 1/2" DOOR UNDERCUT OR 12"x6" DOOR GRILLES. COORDINATE WITH ARCHITECT. <br />AIR CURTAIN BY OTHERS. COORDINATE WITH ARCHITECT. <br />RTU-1 THERMOSTAT. <br />RTU-2 THERMOSTAT. <br />NEW CEILING MOUNTED EXHAUST FAN. REFER TO SHEET M0.02 FOR UNIT SPECIFICATIONS. <br />6"Ø EXHAUST DUCT UP TO ROOF. <br />WATER HEATER. REFER TO PLUMBING PLANS FOR MORE DETAILS. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />A.ALL WORK SHALL BE IN ACCORDANCE WITH CITY CODES, STATE OF CALIFORNIA ENERGY <br />CONSERVATION STANDARDS AND ALL OTHER APPLICABLE CODES. <br />B.PROVIDE SEISMIC RESTRAINTS FOR ALL MECHANICAL EQUIPMENT AS PER SMACNA <br />GUIDELINES (LATEST EDITION). <br />C.ALL DUCTWORK AND PIPING SHALL BE SUPPORTED AND BRACED PER THE SMACNA <br />GUIDELINES FOR SEISMIC RESTRAINTS. <br />D.BALANCE ALL DIFFUSERS AND REGISTERS TO QUANTITIES SHOWN ON DRAWINGS, AND <br />SUBMIT A WRITTEN AIR BALANCE REPORT TO THE OWNER. <br />E.CONTRACTOR SHALL INSTALL REQUIRED HVAC COMPONENTS TO FIT ACTUAL JOB CONDITIONS <br />WITHOUT IMPAIRING THE CONCEPT OF THE DESIGN. <br />F.CONTRACTOR SHALL INCLUDE ANY DUCT TURNS OR ANY ADDITIONAL APPURTENANCES <br />NECESSARY FOR THE PROPER FUNCTION OF THE SYSTEM EVEN THOUGH ARE NOT SHOWN ON <br />THE DRAWINGS. <br />G.ALL SUPPLY & RETURN DUCT BRANCHES SHALL BE EQUIPPED WITH MANUAL DAMPER WETHER <br />INDICATED OR NOT. <br />H.DUCTWORK SHOWN ON DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO ADJUST <br />DIMENSIONS BASED ON ACTUAL FIELD CONDITIONS. <br />I.PROVIDE 1/2" DOOR UNDERCUT FOR ALL DOORS FOR ROOMS WITH NO RELIEF AIR PATH. <br />J.MECHANICAL HOOD SHALL COMPLY WITH 2022 CMC TABLE 508.10.1.3. <br />K.GREASE DUCT CONSTRUCTION AND FITTINGS SHALL BE IN COMPLIANCE WITH THE 2022 CMC <br />CHAPTER 5 SECTION 510. <br />L.CONTRACTOR SHALL PROVIDE AN ACCESS PANEL FOR DUCT CLEAN-OUT AND SHALL BE <br />ACCESSIBLE FOR SERVICE. <br />M.FIELD-INSTALLED GREASE DUCT CLEANOUTS SHALL BE PROVIDED AT EACH TURN AND AT <br />TWELVE (12) FEET INTERVALS PER SECTION 510.3.3.1 OF 2022 CMC. <br />N.HORIZONTAL GREASE DUCT SHALL HAVE A MINIMUM OF 1/4" SLOPE PER FOOT AND SHALL <br />HAVE DUCT CLEAN-OUT (CO) IN EVERY TWELVE (12) FEET AND EVERY DUCT TRANSITION. <br />O.PRIOR TO THE USE OF OR CONCEALMENT OF A GREASE DUCT SYSTEM, A LEAKAGE TEST <br />SHALL BE PERFORMED TO DETERMINE THAT WELDED JOINTS AND SEAMS ARE LIQUID TIGHT. <br />[2022 CMC 510.5.6] <br />P.WIRE SMOKE DETECTOR TO BUILDING FIRE ALARM CONTROL PANEL, IF EXISTING OR ELSE <br />FURNISH AND INSTALL A COMPATIBLE REMOTE AUDIBLE/VISUAL ALARM DEVICE. THE DUCT <br />SMOKE DETECTORS SHALL BE SUPERVISED BY SUCH SYSTEMS IN AN APPROVED MANNER, <br />AND INSTALLED IN ACCORDANCE WITH NFPA 72 AND THE CALIFORNIA BUILDING AND FIRE <br />CODE. <br />8 <br />9 <br />10 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />DC <br />TT <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />1 SCALE: 1/4" = 1'-0" <br />MECHANICAL FLOOR PLAN <br />NORTH <br />GENERAL NOTES: <br />KEY NOTES: <br />11 <br />12 <br />13 <br />14 <br />MECHANICAL <br />FLOOR PLAN <br />M-203 <br />1430 E Edinger Ave <br />3/27/2025
The URL can be used to link to this page
Your browser does not support the video tag.