Laserfiche WebLink
3' <br />- <br />6 <br />" <br />0'-0" <br />7'-0" <br />13'-5" <br />7'-0" <br />28 <br />' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />8' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />0' <br />- <br />6 <br />" <br />11 <br />' <br />- <br />9 <br />" <br />0' <br />- <br />8 <br />" <br />50 <br />' <br />- <br />4 <br />" <br />RTU <br />1 <br />OSA <br />6 <br />3 <br />9 <br />5 <br />5 <br />5 <br />5 <br />AI <br />R <br />F <br />L <br />O <br />W <br />. <br />MAU <br />1 <br />1 <br />RTU <br />2 <br />6 <br />OSA <br />4 <br />KEF <br />1 <br />7 8 <br />210 <br />' <br />- <br />0 <br />" <br />9'-61 <br />4" <br />KEF <br />2 <br />87 <br />10 <br />' <br />- <br />2 <br />14" <br />10 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />DC <br />TT <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />1 SCALE: 1/4" = 1'-0" <br />MECHANICAL ROOF PLAN <br />NORTH <br />NEW MAKE-UP AIR UNIT. REFER TO SHEET M0.2 FOR UNIT SPECIFICATIONS. PROVIDE WITH <br />PRE-FABRICATED MINIMUM 14" HIGH ROOF CURB. PROVIDE WITH 8" CLEARANCE TO ROOF <br />SURFACE. PROVIDED BY CAPTIVEAIRE, INSTALLED BY GC. <br />22"Ø TYPE I KITCHEN HOOD EXHAUST DUCT RISER F/B. <br />12"Ø TYPE I KITCHEN HOOD EXHAUST DUCT RISER F/B. <br />22"x22" MAKE-UP AIR DUCT RISER T/B. <br />6"Ø EXHAUST AIR DUCT RISER F/B. PROVIDE WITH ROOF CAP AND INSECT SCREEN. <br />NEW PACKAGED ROOFTOP UNIT. REFER TO SHEET M0.2 FOR UNIT SPECIFICATIONS AND CUT <br />SHEET FOR PROPER CLEARANCES. PROVIDE DUCT TRANSITIONS IN THE SUPPLY AND RETURN <br />AIR DUCT CONNECTIONS. DUCT DROPS SHALL BE FULL SIZE OF ROOFTOP UNIT DUCT <br />CONNECTION. <br />FAN DISCHARGE SHALL BE FORTY (40) INCHES ABOVE THE ROOF SURFACE AND SHALL HAVE A <br />MINIMUM OF TEN (10) FOOT CLEARANCE FROM ANY OUTSIDE AIR INTAKE, OTHERWISE PROVIDE <br />EXTENSION OF DISCHARGE, ENSURE 3 FT ABOVE AIR INTAKES. <br />PROVIDE ALL NEW GREASE EXHAUST FANS WITH PRE-FABRICATED SPRING VIBRATION <br />ISOLATOR. PROVIDED BY CAPTIVEAIRE, INSTALLED BY GC. <br />MECHANICAL EQUIPMENT SCREEN, EXPAND AS NEEDED FOR PROPER EQUIPMENT'S <br />CLEARANCES. COORDINATE WITH ARCHITECT. <br />PROPOSED METAL LADDER TO ROOF IN FIELD. SHOWN FOR REFERENCE ONLY. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />A.PROVIDE 1/2" MESH BIRD SCREEN ON ALL EXHAUST OUTLETS AND MAKE-UP AIR INLETS. <br />B.PROVIDE MINIMUM OF MERV-13 FILTERS ON ALL OUTSIDE AIR INTAKE TERMINALS. <br />C.MAINTAIN CLEARANCES TO ALL ROOFTOP EQUIPMENT PER MANUFACTURER'S <br />RECOMMENDATION AND AS PER CODE, FOLLOWING THE STRICTEST GUIDELINE. <br />D.VERIFY ACTUAL ROOF ACCESS LOCATION IN FIELD WITH ARCHITECT/LANDLORD. <br />E.VERIFY ACTUAL LOCATION OF MECHANICAL EQUIPMENT WITH ARCHITECT/LANDLORD. <br />PROVIDE 42" GUARDRAILS FOR EQUIPMENT THAT IS WITHIN TEN (10) FEET OF ROOF'S EDGE. <br />F.ENVIRONMENTAL AIR DUCT EXHAUST SHALL TERMINATE NOT LESS THAN THREE (3) FEET <br />FROM A PROPERTY LINE, THREE (3) FEET FROM OPENINGS INTO THE BUILDING, AND TEN (10) <br />FEET FROM MECHANICAL INTAKE TERMINALS. TERMINATE WITH ROOF CAP. <br />G.ALL OUTSIDE AIR INTAKE TERMINALS SHALL TERMINATE NOT LESS THAN 10' IN DISTANCE FROM <br />AN APPLIANCE VENT OUTLET, A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM, OR THE <br />DISCHARGE OUTLET OF AN EXHAUST FAN, UNLESS THE OUTLET IS 3' ABOVE THE OUTSIDE-AIR <br />INLET. <br />H.ALL EXHAUST TERMINALS TO TERMINATE WITHIN TEN (10) FEET OF A MECHANICAL AIR INTAKE <br />SHALL BE AT LEAST THREE (3) FEET ABOVE THE INTAKE TERMINAL. <br />I.VERIFY EQUIPMENT LOCATIONS IN FIELD. MAKE ADJUSTMENTS ON NEW EQUIPMENT IF <br />NECESSARY. <br />J.ALL WORK SHALL BE IN ACCORDANCE WITH CITY CODES, STATE OF CALIFORNIA ENERGY <br />CONSERVATION STANDARDS AND ALL OTHER APPLICABLE CODES. <br />K.PROVIDE SEISMIC RESTRAINTS FOR ALL MECHANICAL EQUIPMENT AS PER SMACNA <br />GUIDELINES (LATEST EDITION). <br />L.ALL DUCTWORK AND PIPING SHALL BE SUPPORTED AND BRACED PER THE SMACNA <br />GUIDELINES FOR SEISMIC RESTRAINTS. <br />M.CONTRACTOR SHALL INSTALL REQUIRED HVAC COMPONENTS TO FIT ACTUAL JOB CONDITIONS <br />WITHOUT IMPAIRING THE CONCEPT OF THE DESIGN. <br />N.CONTRACTOR SHALL INCLUDE ANY DUCT TURNS OR ANY ADDITIONAL APPURTENANCES <br />NECESSARY FOR THE PROPER FUNCTION OF THE SYSTEM EVEN THOUGH IT IS NOT SHOWN ON <br />THE DRAWINGS. <br />O.DUCTWORK AND PIPING SHOWN ON DRAWINGS ARE DIAGRAMMATIC. <br />P.CONTRACTOR TO ENSURE MANUFACTURER CLEARANCES ARE MET. <br />Q.PROVIDE 3/4" TYPE M COPPER CONDENSATE DRAIN LINE TO ALL RTU UNITS, REFER TO <br />PLUMBING PLANS FOR ROUTING AND TERMINATION. <br />R.GREASE DUCT CONSTRUCTION AND FITTINGS SHALL BE IN COMPLIANCE WITH THE 2022 CMC <br />CHAPTER 5 SECTION 510. <br />S.GREASE DUCT DISCHARGE MUST BE A MINIMUM OF 10 FEET OF CLEARANCE FROM OUTLET TO <br />ADJACENT BUILDINGS, PROPERTY LINES AND AIR INTAKES. WHERE SPACE LIMITATIONS <br />PREVENT A 10 FOOT HORIZONTAL SEPARATION FROM AIR INTAKES DUCT MAY BE ELEVATED <br />TO 3 FEET ABOVE AIR INTAKES WITHIN 10 FEET. [2022 CMC 510.9.1(3)] <br />T.BUILDINGS OF MORE THAN 15 FEET IN HEIGHT SHALL HAVE AN INSIDE MEANS OF ACCESS TO <br />THE ROOF MOUNTED EQUIPMENT. [2022 CMC SEC. 304.3.1, 304.3.1.1] <br />U.CONTRACTOR SHALL PROVIDE AN ACCESS PANEL FOR DUCT CLEAN-OUT AND SHALL BE <br />ACCESSIBLE FOR SERVICE. <br />8 <br />9 <br />GENERAL NOTES: <br />KEY NOTES: <br />10 <br />MECHANICAL <br />ROOF PLAN <br />M-204 <br />1 <br />1 <br />1 <br />1430 E Edinger Ave <br />3/27/2025