Laserfiche WebLink
(N) 2"CW <br />G <br />G <br />EDINGER AVE. <br />GR <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br />. <br />GENERAL NOTES: <br />A.CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS BEFORE <br />START OF WORK INCLUDING BUT NOT LIMITED TO LOCATION, FLOW <br />DIRECTION, SIZE OF EXISTING UTILITIES. <br />B. CONTRACTOR TO COORDINATE WORK WITH OTHER TRADES. <br />C. WHERE CONDITIONS ARE SHOWN OR NOTED AS EXISTING, THEY <br />ARE BASED ON THE BEST INFORMATION AVAILABLE AT THE TIME <br />OF PREPARATION OF THESE DRAWINGS. NO WARRANTY IS IMPLIED <br />AS TO THE ACCURACY OF SAME HOWEVER, CONTRACTOR IS TO <br />FIELD VERIFY ALL CONDITIONS. SHOULD FIELD CONDITIONS DIFFER <br />FROM THOSE SHOWN HEREIN THEY SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT AND ENGINEER PRIOR TO <br />PROCEEDING WITH WORK. <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />CAD <br />Author <br />9-01-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 07/16/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />3 PC Corr.2 07/01/2025 <br />1 <br />PLUMBING SITE PLAN <br />SCALE: 1/8" = 1'-0" <br />NORTH <br />PLUMBING <br />SITE PLAN <br />P-102 <br />1 <br />2 <br />2 <br />KEY NOTES: <br />1 APPROX.LOCATION OF NEW WATER METER, <br />VERIFY WITH CIVIL PLAN <br />APPROX.LOCATION OF 2" RPZ ABOVE GROUND. <br />COORDINATE EXACT LOCATION WITH CIVIL PLAN <br />TO GAS UTILITY VERIFY WITH CIVIL PLANS <br />TO NEW WATER METER, VERIFY EXACT LOCATION <br />WITH CIVIL PLAN <br />NEW GAS METER <br />VERIFY EXACT LOCATION ON SITE <br />APPROX.LOCATION OF NEW 1000 <br />GALLONS GREASE INTERCEPTOR <br />BELOW GRADE. VERIFY AND <br />COORDINATE EXACT LOCATION AND <br />REQUIREMENT WITH CIVIL DRAWINGS <br />NEW SEWER LATERAL, FIELD VERIFY EXACT <br />LOCATION, COORDINATE WITH CIVIL DRAWING <br />4"W TO GREASE RECEPTOR <br />4" TO NEW SEWER LINE <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />9 <br />8 <br />7 <br />6 <br />5 <br />1 <br />4 <br />2 <br />3 <br />1430 E Edinger Ave <br />3/27/2025